Tender Value
₹48.7 L
EMD Value
₹97,340
Closing Date
15 Jul 2026, 6:00 pm
GARRISON ENGINEER
GARRISON ENGINEER (AF) AIR FORCE STATION TAMBARAM, CHENNAI - 600 046
SPL REPAIRS REPLACEMENT OF BER PACKAGE AC PLANT AT AFS TAMBARAM
2026_MES_774419_1
GE(AF)/TBM/8907/E8
Open Tender
Civil Works
180 days
AIR FORCE STATION TAMBARAM
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF TAMBARAM
₹97,340
Yes
24 Jun 2026
24 Jun 2026
17 Jul 2026
24 Jun 2026
15 Jul 2026
8 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Design, Supply, installation, testing & commissioning 34 HP outdoor unit with cooling of Variable Refrigerant Flow (VRF) system with multi indoor unit with outdoor units including individual controller for cooling type operation. Outdoor units equipped with highly efficient twin rotary compressors with inverter type compressor, special acryl precoated heat exchanger, low noise condenser fan, auto check function for connection error, having interconnected control wiring between indoor unit, outdoor unit & control panel and refrigerant piping housed in compact housing duly powder coated complete as required for trouble free operation, refrigerant should be R-410a complete all as specified and directed by Engineer-in-Charge.
01 No (Overall 34HP - Capacity & Numbers of the unit may Vary)
Note for Out door unit:
(i) Highly efficient Inverter Compressors: The unique design of the inverter compressor ensures that the refrigerant is directly injected in to the compressor chamber. The suction gas enters directly into the scroll, there is no super heat gain due to compressor motor assembly, this results in efficiency enhancement by upto 3%.
(ii) VRF units are fitted with 100% inverter compressors. The unique logic of the system is that it optimally loads compressors in such a way that maximum efficiencies are achieved under any load condition.
(iii) High COP and IPLV (Integrated Part Load Value).
(iv) 100% capacity at 43 degree centigrade.
(v) Non-stop operation even at 56 degree centigrade.
(vi) Wide Operating Range: The system can operate from 10 degree centigrade to 56 degree centigrade in the cooling mode.
(vii) Superior Accumulator Design: The VRF system is designed with the largest twin Accumulator in its class. This new design allows the system to perform seamlessly in low-load condition even below 30% without tripping.
viii) Weather Proof Outdoor Unit Design: Outdoor unit is specifically designed to handle extreme climatic conditions, corrosion and polluted atmosphere.
* Powder coated GI sheet metal cabinets.
* All hardware of anti-rust quality.
* Conformal coating on PCBs to protect from dust and humidity.
* Hydrophilic blue fin for better corrosion resistance.
* Weather-proof enclosures for critical components. | 1 | Each job | 1 | ₹1 |
| 1.01 | * Demand Control Mode or Economy Mode the capacity of the ODUs of the VRF can be set at 25%, 50% & 75% depending on the need.
(ix) The system designed to operate across a wide voltage range from 320 volts to 460 volts resulting in high uptime even in erratic power conditions.
* Emergency Backup Operation, the compressor backup in outdoor units that have two compressors, the VRF system can function or maintenance down time of one compressor. Supply, installation, testing & commissioning indoor cassette unit of the following capacities, 4 way equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, outdoor cabinet, drain pan and drain pump, cordless remote, cabling, vibration isolation, earthing, necessary supports etc as per specifications complete all as specified and directed.
1.7 TR Cassette Unit - 03 Nos
2.3 TR Cassette Unit - 02 Nos
2.8 TR Cassette Unit- 03 Nos
4.0 TR Cassette Unit - 02 Nos | - | - | - | - |
| 1.03 | Supply and Installation of Refnet joints (Refrigerant branch kit) for taking branches between various indoors as per VRF scheme drawings. The refnet joint set consists of both liquid and gas line branch kits complete all as specified and directed by Engineer-in-Charge.
Indoor - 10 Nos
Outdoor - 01 Nos | - | - | - | - |
| 1.04 | VRF Central Controller - Supply, Installation, testing and commissioning of BMS compatible Network Interface and Central Remote Controller for monitoring and Controlling the VRF equipments in third party BMS as required basis. | - | - | - | - |
| 1.05 | VRF LOW SIDE WORKS
Installation , Testing, Commissioning and Handing over the VRF outdoor units -46.0 HP TOP DISCHARGE VRF ODU - 01 No
Installation , Testing, Commissioning and Handing over of the following VRF Indoor Units : Cassette Unit.- 10 Nos | - | - | - | - |
| 1.06 | REFRIGERANT PIPING : Supply, Installation and Testing of Refrigerant piping, fittings and Y Branch with suitable thick tubular nitrile rubber insulation finished with laminated glass cloth.Suction line thickness - 19 mm and Liquid Line Thickness - 13 mm. All the tools and tackles required to install the refrigerant piping will have to be arranged by the vendor only without dependency on the client.Complete piping workmanship to be carried out as per recommended practice with the pipe sizes 1/4" to 1 5/8" of length -200RM ( Aprox) | - | - | - | - |
| 1.07 | Nitrogen Pressure Testing at site complete all as specified and directed by Engineer-in-Charge. | - | - | - | - |
| 1.08 | Supply and installation of communication cable carried out with 2 core x 1.5 sqmm shielded cable including PVC conduit, between indoor unit to outdoor unit complete all as specified and directed by Engineer-in-Charge. - 450RM (Approx) | - | - | - | - |
| 1.09 | VRF pipe protection finish for the exposed pipes (Suction & Liquid) : supply and application of one coat of Weatherprotekt coating, fixing 10 mil woven glass cloth, again one coat of Weatherprotekt coating and when finally dry complete with final coat of Weatherprotekt Coating complete all as specified and directed by Engineer-in-Charge. - 200RM (Approx). | - | - | - | - |
| 1.1 | VRF pipe protection finish for the exposed pipes (Suction & Liquid) : supply and application of one coat of Weatherprotekt coating, fixing 10 mil woven glass cloth, again one coat of Weatherprotekt coating and when finally dry complete with final coat of Weatherprotekt Coating complete all as specified and directed by Engineer-in-Charge. - 180RM (Approx). | - | - | - | - |