| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.3 LAdmitted-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | ₹22.3 L | L1 | Admitted-Finance |
| 2 | L2₹27.6 LAdmitted-Finance | ₹27.6 L | L2 | Admitted-Finance |
| 3 | L3₹29.0 LAdmitted-Finance RZ 50D GALI NO 13 VASHISHT PARK PANKHA ROAD NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | ₹29.0 L | L3 | Admitted-Finance |
| 4 | L4₹42.7 LAdmitted-Finance 137 D6 ARAVALI HEIGHTS DPL DWARIKADISH ROAD DHARUHERA REWARI HARYANA 123106 | REWARI | HARYANA | 123106 | ₹42.7 L | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S Anand Enterprises L1 | Shrikanth Solutions L4 | A B K Enterprises L2 | M/S PARKASH ENTERPRISES L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Material and labour for checking loose connections, sparks,earth leakage etc by disconnecting and taking down the swiches /switch boards/LEDs/Fans/DBs /fixtures etc and making good by clearing the fault, making proper insulation and testinng and restoring the supply etc all as directed.
Note-i) Replacement of any part such as switches, sockets, tube lights,DBs , MCBs shall be measured and paid seperately under relevent items. | 800 | Each Job | 5 ₹4,000 | 5 ₹4,000 | 10 ₹8,000 | 1 ₹800 |
| 2.00 | Taking down carefully point wiring removing from site of work and making good to the disturbed surfaces of walls/floors etc all as specified and directed. | 770 | Per Point | 2 ₹1,540 | 10 ₹7,700 | 2 ₹1,540 | 1 ₹770 |
| 3.00 | Taking down carefully MCB Distribution board SPN/TPN off sizes & any capacity by unscrewing from DB box, all as directed. | 78 | Each | 2 ₹156 | 10 ₹780 | 2 ₹156 | 1 ₹78 |
| 4.00 | M&L Point wiring for One light/fan point controlled by one switch with PVC insulated fire retardant low smoke (FRLS) multi stranded copper conductor cable of 1.5 sqmm in and including PVC concealed rigid conduit (ISI mark) and pressed steel terminal boxes (for mounting switches / sockets /regulators / ceiling roses etc) made out of MS sheet not less than 1.6 mm and 6cm depth including painting with one coat of red oxide primer on internal and external surface covered with 3mm thick laminated plastic sheet ISI marked including 1.5 sqmm PVC insulated fire retardant low smoke (FRLS) multi stranded copper conductor cable as earth continuity wire connected to common earth and each terminal box/fitting all as specified and directed .
Note :- (i)The wiring shall be provided in standard colour code
(ii) The quoted rate is deemed to include for cutting/chasing for concealing the conduit and making good the surface to match the existing surfaces.
(iii) In case of ceiling portion where concealed conduiting is not possible, the surface conduit shall be provided ad directed.
(iv) The earth wire shall be connected to common earth and each terminal boxes and fitting all as directed. | 150 | Per Point | 150 ₹22,500 | 300 ₹45,000 | 240 ₹36,000 | 270 ₹40,500 |
| 5.00 | All as per description of serial item No. 4.00 here in before but for One 3-pin socket outlet 5 Amp on independent board. | 100 | Per point | 180 ₹18,000 | 300 ₹30,000 | 240 ₹24,000 | 270 ₹27,000 |
| 6.00 | All as per description of serial item No. 4.00 here in before but one 3 pin socket outlet 5 Amp on same board | 100 | Per point | 50 ₹5,000 | 300 ₹30,000 | 70 ₹7,000 | 100 ₹10,000 |
| 7.00 | All as per description of serial item No. 4.00 here in before but for One 5-pin socket outlet 5/6 & 15/16 Amp on independent board. with 2.5 sqmm FRLS multistranded copper cable including 2.5 sqmm FRLS multistranded copper cable as earth continuity wire connected to common earth and each terminal box/fitting complete all as specified and directed. | 100 | Per Point | 200 ₹20,000 | 550 ₹55,000 | 300 ₹30,000 | 300 ₹30,000 |
| 8.00 | All as per description of serial item No. 4.00 here in before but for One industrial power socket 20 Amp on independent board with 4 sqmm FRLS multistranded copper cable including 4 sqmm FRLS multistranded copper cable as earth continuity wire in existing conduit connected to common earth and each terminal box/fitting complete all as specified and directed. | 100 | Per Point | 220 ₹22,000 | 600 ₹60,000 | 300 ₹30,000 | 360 ₹36,000 |
| 9.00 | All as per description of serial item No. 4.00 here in before but in existing PVC Conduit. | 80 | Per point | 100 ₹8,000 | 650 ₹52,000 | 300 ₹24,000 | 270 ₹21,600 |
| 10.00 | All as per description of serial item No. 4.00 here in before but for One 3-pin socket outlet 5 Amp on independent board in existing PVC Conduit. | 80 | Per point | 200 ₹16,000 | 650 ₹52,000 | 300 ₹24,000 | 270 ₹21,600 |
Updated dates
Tender Value
₹49.8 L
EMD Value
₹1 L
Closing Date
25 Mar 2026, 6:00 pmClosed
GE (AF) GURGAON
GE (AF) GURGAON
REPAIR AND MAINT OF GEYSER CEILING FAN EXHAUST FAN DESERT COOLER SPLIT/WINDOW AC REFRIGERATOR DEEP FREEZER WATER COOLER ELECTRIC METER AND INTERNAL ELECTRIFICATION INCL MISC ITEMS AND REPAIR AND MAINT OF EXTERNAL WATER SUPPLY DISTRIBUTION SYSTEM REPL
2026_MES_754243_1
GE/GUR-/NIT-154/2025-26
Open Tender
Civil Works
240 days
GE (AF) GURGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) GURGAON
₹1 L
1 Apr 2026
25 Feb 2026
27 Mar 2026
25 Feb 2026
25 Mar 2026
11 Mar 2026
Material and labour for checking loose connections, sparks,earth leakage etc by disconnecting and taking down the swiches /switch boards/LEDs/Fans/DBs /fixtures etc and making good by clearing the fault, making proper insulation and testinng and restoring the supply etc all as directed. Note-i) Replacement of any part such as switches, sockets, tube lights,DBs , MCBs shall be measured and paid seperately under relevent items.
Taking down carefully point wiring removing from site of work and making good to the disturbed surfaces of walls/floors etc all as specified and directed.
Taking down carefully MCB Distribution board SPN/TPN off sizes & any capacity by unscrewing from DB box, all as directed.
All as per description of serial item No. 4.00 here in before but for One 3-pin socket outlet 5 Amp on independent board.
All as per description of serial item No. 4.00 here in before but one 3 pin socket outlet 5 Amp on same board
All as per description of serial item No. 4.00 here in before but for One 5-pin socket outlet 5/6 & 15/16 Amp on independent board. with 2.5 sqmm FRLS multistranded copper cable including 2.5 sqmm FRLS multistranded copper cable as earth continuity wire connected to common earth and each terminal box/fitting complete all as specified and directed.
All as per description of serial item No. 4.00 here in before but for One industrial power socket 20 Amp on independent board with 4 sqmm FRLS multistranded copper cable including 4 sqmm FRLS multistranded copper cable as earth continuity wire in existing conduit connected to common earth and each terminal box/fitting complete all as specified and directed.
All as per description of serial item No. 4.00 here in before but in existing PVC Conduit.
All as per description of serial item No. 4.00 here in before but for One 3-pin socket outlet 5 Amp on independent board in existing PVC Conduit.
All as per description of serial item No. 4.00 here in before but one 3 pin socket outlet 5 Amp on same board in existing PVC Conduit.
Taking out carefully the existing burnt sub main wiring of size 4 Sqm / 6 Sqmm PVC insulated multi stranded aluminum conductor cable along-with earth continuity conductor from the PVC / rigid steel, concealed/surface conduit complete all as specified and directed.
Supply and laying sub main wiring complete with 03 runs (Phase, Neutral & Earthing colour code) of single core 6 sqmm fire retardant low smoke (FRLS) PVC insulated copper conductor cable multistranded and sheathed LT 1100 V grade drawn through and including concealed non metallic PVC conduit 20mm dia ISI marked and accessories surface fixed on wall /floor etc all as specified. Note:- 03 runs of cable and one run of PVC conduit shall be considered as one unit for measurement purposes.
Supply and laying sub main wiring complete with 03 runs (Phase, Neutral & Earthing colour code) of single core 4 sqmm fire retardant low smoke (FRLS) PVC insulated copper conductor cable multistranded and sheathed LT 1100 V grade drawn through and including concealed non metallic PVC conduit 25mm dia ISI marked and accessories surface fixed on wall /floor etc all as specified. Note:- 03 runs of 01 metre cable and 01 run of PVC conduit shall be considered as one unit for measurement purposes.
Supply and laying sub main wiring complete with 05 runs ( 3 nos for three phase, Neutral & Earthing colour code) of single core 4 sqmm fire retardant low smoke (FRLS) PVC insulated copper conductor cable multistranded and sheathed LT 1100 V grade drawn through and including steel metalic conduit 25mm dia ISI marked and accessories surface fixed on wall /floor etc all as specified. Note:- 05 runs of cable 01 metre 01 run of PVC conduit shall be considered as one unit for measurement purposes.
Supply and laying sub main wiring complete with 05 runs ( 3 nos for three phase, Neutral & Earthing colour code) of single core 6 sqmm fire retardant low smoke (FRLS) PVC insulated copper conductor cable multistranded and sheathed LT 1100 V grade drawn through and including steel metalic conduit 25mm dia ISI marked and accessories surface fixed on wall /floor etc all as specified. Note:- 05 runs of cable 01 metre 01 run of PVC conduit shall be considered as one unit for measurement purposes.
Supply and fix as in repair Switch piano flush type single pole one way 5/6 amp complete all as specified and directed..
Supply and fix as in repair Switch piano flush button single pole one way 15/16 amp complete all as specified and directed.
Supply and fix as in repair socket piano flush type 5/6 amp complete all as specified and directed..
Supply and fix as in repair Socket out let 2 in 1, 3 pin, 5/6 and 15/16 amp multipurpose, flush type complete all as specified and directed.
S&F in repair switch piano type, 5 Amp, single pole two way, 230 Volts, flush type complete all as specified and as directed by Engr- in -charge.
supply and fixing Bell push, flush type, 5 amp 230V AC 50 Hz for complete all as specified and directed by Engr-In-Charge.
supply and fixing Buzzer, Ding Dong AC. 230 volts, single pole complete all as specified and directed by Engr-In-Charge.
Supply and fix as in repair Ceiling rose surface Bakelite 65 x 50 mm three terminals complete all as specified and directed.
supply and fix as in repairs MCB DB single pole and neutral 240 volt SPN 04 way with 200 Amps rated bus bar double door type complete all as specified and directed.Make-IndoAsian/ Legrand/ ABB
All as per description of serial item No. 25.00 here in before but 8 way Make-IndoAsian/ Legrand/ ABB
All as per description of serial item No. 25.00 here in before but 12 way Make-IndoAsian/ Legrand/ ABB
Supply and fix as in repairs MCB SPN 10-32 Amps 240Volts, Breaking capacity 10 KA 'C' curve complete all as specified and directed. Make- IndoAsian/ Legrand/ ABB
Supply and fix as in repairs ELCB SPN 40 Amps 240Volts, complete all as specified and directed.Make- IndoAsian/ Legrand/ ABB
Supply and fix as in repairs MCB SP 6-32 Amps 240Volts, Breaking capacity 10 KA 'C' curve complete all as specified and directed.Make- IndoAsian/ Legrand/ ABB
Supply and fix as in repairs MCB TPN 63 Amps 415 Volts, Breaking capacity 10 KA 'C' curve complete all as specified and directed. Make- IndoAsian/ Legrand/ ABB
Supply and fixing as in repairs TPN DB double door, IP 45 protection with powder coated enclosure 4 way insulated bus bar complete all as specified and directed. Make : IndoAsian/ Legrand/ ABB
Supply and fixing as in repairs vertical TPN DB double door, IP 45 protection with powder coated enclosure 4 way insulated busbar assembly including MCCB 4 pole, 415 V, 125A, 16 kA - 01 No complete all as specified and directed. Make : IndoAsian(Optipro) / Legrand/ ABB
Supply and fix LED batten with extruded aluminium body and PC diffuser complete with inbuilt driver 1x20 watt including electrical connection, Cat Ref CCS-100-20-65HL2-DP-NWH of Make: Crompton Greaves or equivalent in Make-Havells/Phillips/Wipro.
All as per description of here in before but 10 watt Make-CROMPTON Model CSS-103-1065-SL-DP-NWH Havells/Phillips/Wipro
Suply and fixing in repair Lamp holder angular PVC polycrbonate type with back plate suitable for PVC casing capping/conduit fitting complete.
S&F as in repairs modular switch 10 Amp one way switch one module complete all as specified and directed.
S&F as in repairs modular multi socket 10 Amp 2/3 pin two module complete all as specified and directed.
S&F as in repairs modular switch 25 Amp one way switch one module complete all as specified and directed.
S&F as in repairs modular socket 25 Amp 2/3 pin two module complete all as specified and directed.
S&F as in repairs modular metal box with frame & cover and plate suitable for one module complete all as specified and directed.
S&F as in repairs modular metal box with frame & cover and plate suitable for two module complete all as specified and directed.
S&F as in repairs modular metal box with frame & cover and plate suitable for three module complete all as specified and directed.
S&F as in repairs modular metal box with frame & cover and plate suitable for four module complete all as specified and directed.
S&F as in repairs modular metal box with frame & cover and plate suitable for six module complete all as specified and directed.
Supply and fixing in repair metal flush box 1/2 module complete all as specified and directed.
Supply and fixing in repair metal flush box 3 module complete all as specified and directed.
Supply and fixing in repair metal flush box 4 module complete all as specified and directed.
Supply and fixing in repair metal flush box 6 module complete all as specified and directed.
S&F domestic surface mounting gang box for fixing of socket outlet and switches of size 100mmx100mmx50 mm deep complete all as specified and directed.
S&F domestic surface mounting gang box for fixing of socket outlet and switches of size 100mmx100mmx50 mm deep complete all as specified and directed.
S&F domestic surface mounting gang box for fixing of socket outlet and switches of size 100mmx100mmx50 mm deep complete all as specified and directed.
S&F domestic surface mounting gang box for fixing of socket outlet and switches of size 100mmx100mmx50 mm deep complete all as specified and directed.
S&F domestic surface mounting gang box for fixing of socket outlet and switches of size 100mmx100mmx50 mm deep complete all as specified and directed.
Suply and fixing as in repairs recessed LED Driver with input voltage 90-300 V AC , max current 0.7 A and output voltage 40-55 V for ceiling panel layout suitable for 600X600 MM modular ceiling grid and also can be suspended with provided kit of Make-Havells/Phillips/Wipro as directed by engr-in - charge.
Suply and fixing as in repairs recesse mounted 36w LED ceiling light fitting provided with best in class aesthetics premium white poeder coated frame blends seamlessy with ceiling layout suitable for 600X600 MM modular ceiling grid and also can be suspended with provided kit. Make-Havells/Phillips/Wipro
Suply and fixing as in repairs integrated LED bulk head luminaire 10 watt comprising of pressure die cast housing, acrylic diffuser & frame IP65 protection & available in 5700k (CDL) & 3000K (WW) colour temperatures pre-wired incl connection with flexible twin core wire complete all as specified and directed. Make-Havells/Phillips/Wipro
S&F as in repairs sheet metal enclosure single pole and neutral encolsure with two pin and earth plug and socket complete with provision for fixing of one MCB SP 20 Amps complete all as specified and directed.
Supply and fixing as in repairs stepped type electronic fan regulator , SP 230 Volt 100/120 watt complete all as specified and directed.
Attending day to day complaints for ceiling fan, exhaust fan and wall mounted fans installed at various locations in AF Stn Mohammadpur and rectifying the complaints complete all as directed by Engr-in-Charge. Note : (i) Defective parts / winding required to be replaced shall be measured and paid separately under respective items.
Taking down ceiling fan (C/F of any size/make), cleaning its dust properly oiling and hanging the same back to its original position including connecting the wire to ceiling rose etc complete after completing the wiring all as specified and as directed by Engr-in-Charge. Note :- (i) The spares like cotter pin, nuts & bolts, rubber bush & hooks etc defective/damage deemed to be replaced and make the ceiling fans functional. The rates quoted for the same deemed to be included for the above job.
Taking down exhaust fan and re-connecting up including provision of cable from ceiling rose to exhaust fan after cleaning all dust complete all as specified and as directed. Note :- (i) The spares like nuts & bolts etc defective/damage deemed to be replaced and make the fans functional. The rates quoted for the same deemed to be included for the above job.
Supply & fix capacitor of 2.5 mfd complete all as specified and directed.
-Ditto- but 3.15mfd complete all as specified and directed.
-Ditto- but 4.0 mfd complete all as specified and directed.
Supply & fix capacitor of 0.85/1.00 mfd complete all as specified and directed.
S & F heavy duty PVC cable 1100 volts grade , insulated aluminium multi stranded conductor, twin core wire of size 4 sqmm complete all as specified and as directed.
S & F heavy duty PVC cable , 1100 volts grade insulated aluminium multi stranded conductor, twin core wire of size 6 sqmm complete all as specified and as directed.
Material and labour for fixing plastic body exhaust fan Complete with blades and motor for 250 mm sweep in replacment of old u/s platic body exhaust fan as per site requirement all as directed by Engineer-In-charge.
S&F ventilation fan motor suitable for 300 mm sweep metal fans having double ball bearing, heavy duty motor suitable for existing make/model complete all as specified and directed by engr-in-charge.
S&F ceiling fan 1250mm sweep, aerodyanamic profile blades for silent operation with high twist angles leading to high air delivery, rust free re-inforced ABS blades, dust and mark resistant caoting pearl white Stealth Air complete all as specified and directed.
S & F plug top 16 Amps, 240 volts complete all as specified and as directed.
S & F MCCB 125 Amps, 4 pole, Breaking capacity 16 KA, 415 V adjustable type all as specified of capacity complete all as directed.
S & F MCCB 100 Amps, 4 pole, Breaking capacity 16 KA, 415 V adjustable type all as specified of capacity complete all as specified and directed.
M & L for earthing complete in repairs with galvansihed steel earth plate electrode 600 mm x 600 mm x 6.3 mm thick buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level connected to 4.0 mm dia galvansihed earth lead wire by means of nuts bolts check nuts and GI washers including PCC pit in PCC 1:2:4 type B-1 RCC cover 20 mm dia (medium grade) GI watering pipe with funnel wire mesh and protection pipe of GI of suitbale size upto 7.5 mtr length including charcoal black cotton soil as required at site to achieve the earthing result and common salt, excavation earth work etc in any type of starta complete all as shown in electrical plate No 3 as specified, GI wire suitable size and length for continuity earth wire from test point to main distribution Board and all as directed. (Note: (i) Rate for achieving required depth by compressor machine if required is deemed included in item unit rate. (ii) After earthing contractor should test the earth value and submit register for earth resistance result to Engr-in-Charge. )
S & F LED Bulbs of 07 watts including taking down complete all as specified and directed.
S & F LED Bulbs of 09 watts including taking down complete all as specified and directed.
GEYSER and SOLAR HEATER
M&L for taking down unserviceable geyser of 25 Ltr capacity from existing position by disconnecting Elect/ water connectioions, from any position, locations and replacing the following unserviceable parts as mentioned below: -
(i) S&F in repairs thermostat suitable for 25 ltr storage type Vertical water heater ISI mark as per existing one complete all as specified and directed.
(ii) S&F in repairs LED indication lamp suitable for Geysers in roud/ rectangular shape complete all as specified and directed.
(iii) S&F in repairs Geyser assembly suitable to fix thermostat, heating elements as of the existng size suitable for 25 ltr capacity geyser including suitable washers, clamps with bolts & nuts suitable for 06/09 hole complete all as specified and directed.
(iv) S&F in repairs fusible plug suitable for 25 ltr capacity Geysers as per existing complete all as specified and directed.
(v) Taking down unserviceable bottom/ top cover plates (2 half) and S&F with new bottom/ top cover plates with machine coloumns of Geyser 25 ltr capacity complete all as specified and directed.
(vi) S&F in repairs steel water tank suitable for 25 ltr capacity water heater vertical type as per existing model and size complete all as specified and directed.
(vii) S&F safety plug suitable for 25 ltr capacity vertical type water heater as per existing model/ make complete all as specified and directed.
(viii) S&F in replacement of M S heavy duty fabricated frame suitable for holding water tank of 25 ltr capacity geyser, as per sample and existng shape and size including suitable hole for mounting the Geyser complete all as specified and directed. Note: Sample can be taken for the geyser by the contractor from concerned JE E/M sub division before quoting the rate.
(ix) S&F in replacement heating element 2 KW triangle type suitable for 25 ltr capacity vertical type water heater ISI mark. Make: Theeta complete all as per existing one and as directed.
(x) S&F glass wool heat insulation superior quality suitable for geyser of Capacity 25/35/50 ltr complete all as directed.
(xi) S&F outer cover in replacement suitable for 25 ltr capacity vertical water heater as per existing model heavy duty complete all as specified and directed.
(xii) Supply only nuts, bolts, washers suitable of existing size and model suitable for fixing of Geyser assembly with geyser tank complete.
(xiii) S&F steel braided connection mesh type for HOT/ cold water supply 2' long heavy duty ISI mark as per sample complete all as specified and directed.
M&L for removal and un-installation of existing solar leaked tank from the system and refixing after necessary repair to make it serviceable in all respect.
S&F, installation, testing and commissioning of new steel solar water heater tank of 200 litres capacity complete in replacement of existing unsserviceable/leaked solar tank with insulation and inlet and outlet connection for 6 Nos accn and over flow pipes including all GI fittings i.e GI Socket, Elbow, Union, Plug, rubber gasket etc as required at site complete all as specified and directed.
M&L De-scaling of existing solar flat plate collector brazing where ever required, all fittings and gaskets in place complete all as directed.
S&F insulation of existing hot water line with 9mm Nitrile insulation for better performace of the solar water heater complete all as directed.
SITC for fresh hose pipe for the solar water heaer system from solar water tank to collectors complete all as directed.
Repair/Replacement of electrical back up heating element 3 KW suitable for Solar heating system including electrical connection with DB and all accessories required for smooth functioning electrical backup complete all as specified and directed.
AC Refrigerator,Dessert cooler etc
M&L for rewinding of the blower motor 1/6,1/5,&1/8 HP of AC any type /capacity with same gauge super enamelled copper wire complete including taking out old unserviceable winding kit complete all as specified and as directed.
M&L for rewinding of the outdoor fan motor any type /capacity ((upto 1/13 HP, 800 rpm, 57 watt) thermally protected with same gauge super enamelled copper wire complete including taking out old unserviceable winding kit complete all as specified and as directed.
Supply and fixing in replacement of outdoor fan Blade for AC upto 2 ton as per site, complete as directed. Note: Sample shall be checked at site before procurement to match the existing models.
Supply and fixing in replacement of starting relay of existing makes and capacity duly ISI marked for AC W/T and split type 1.5/2 Ton capacity as per site requirement, complete all as specified and as directed.
Supply and fixing in replacement of starting capacitor of existing make and capacity (40/60 & 80/100mfd) duly ISI marked for window type A/C 1.5 ton and split type AC 2 ton complete all as specified and as directed.
Supply and fixing in replacement of three state running capacitor of existing make and capacity (50/6, 45/5 & 36/6mfd) duly ISI marked for window type A/C 1.5 ton and split type AC 2 ton complete all as specified and as directed.
Supply and fixing in replacement of refrigerant tubing for suction /discharge of (5/8, 1/4, & 1/2 )including insulation tubing all as per site requirement and as directed by Engr-in-Charge.
Supply and fixing in replacement of of capacitor 10 Mfd blower motor ISI marked complete all as specified and as directed.
S&F in replacement of PCB card, board type/box type (2 PCB cards fabricated in one box) suitable for existing split type AC 1.5/2 Tone AC of any make/model complete all as specified and as directed.
S&F in replacement of cooling coil of indoor split type AC 1.5/2.0 Ton capacity complete all as per existing make and model
Supply and fixing in replacement of Split AC Remote (for any make AC) as per model on site. Note: Sample shall be checked at site before procurement to match the existing models.
S& F Rotary compressor suitable for 2TR Split AC all as per site requirement.
S& F Rotary compressor suitable for 1.5TR Split AC all as per site requirement.
Supply and fixing in replacement of compressor reciprocating type (hermetically) sealed suitable for capacity 80/40, 120/40, 150/150 litre water cooler complete all as specified and as directed. Make: Emerson/Hitachi/LG
Supply and fixing in replacement of thermostat switch suitable for existing of water cooler any make and capacity complete all as specified and as directed. Make: Renutrol/Indofos/Annapurna/Totaline
Supply and fixing starting relay and overload relay suitable for existing size and make of water cooler complete all as specified and as directed. Make: Epcos/Asian
Supply and fixing in replacement of starting capacitor for water cooler of suitable for existing size & make of water cooler complete all as specified and as directed.
Supply and fixing running capacitor suitable for existing size & make water cooler complete all as specified and as directed.
Supply and fixing drier/filter of suitable capacity, complete all as specified and directed.
Dismantling of old defective condenser fan motor of water cooler of any make and capacity and refixing and testing the same after rewinding with super enameled copper wire of existing gauge or gauge as approved by Engineer-in-Charge including replacement of shaft/ bush etccomplete all as specified and as directed.
S&F in replacement of of fan blade of condenser motor of any make and capacity of water cooler complete all as specified and as directed.
Repair and maintenance of refrigerator of any capacity capacity including replacement of following unserviceable parts starting relay - 01 No., over load relay-01 No, capacitor 20 mfd -01No, Door opening handle - 01 Set, freezer chamber - 01 No, Door panel complete - 01 set, thermostat switch - 01 No, vegetable tray-01 No, Door rubber beeding set - 01 Set, ice tray - 02 Nos. Testing and commissioning of refrigerator after repair in its original location all as specified and directed.
Dittoas above item No 49 but Refrigerant gas R- 32 in inverter type Split AC and any capacity complete all as directed
M&L for visiting of Technician on site and checking, inspecting & detecting fault in AC's, Deep Freezers, Water coolers & refrigerators of any capacity, type, any make & model by technicians and rectifying minor defects on site and noting down material required to make cooling appliance functional in next visit. Note: (i) Spare required will be measured saperately. (ii) Servicing visit will not be measured under this item.
M&L for servicing of room desert cooler of any make size by cleaning, oiling & greasing, checking of defects and rectifying unserviceable switches, control switch etc adjusting and setting for work including complete electric wiring with 3 core flexible cable plug top and testing complete all as specified and as dirceted by Engr-in-Charge.
M&L for replacement of tullu pump submersible type for desert cooler having, 2mtrs head, 500l/h discharge rate, 25 watts, single phase, complete all as specified and as directed.
Supply and fix in replacement of New fan motor of 120W, 220 Volts AC, copper winding, Class E insulation, 1500 rpm, steel shaft, including capacitor of 4 mfd for desert coolers complete all as specified and as directed. Note :- The contracter shall provide warranty period of 1 year from the date of replacement.
Supply and fixing in replacement of capacitor 4 Mfd blower motor & desert cooler motor ISI marked complete all as specified and as directed.
M&L for plastic distributor 3 way of superior quality as per site requirement complete all as specified and as directed.
M&L for PVC pipe 15 mm dia for desert cooler for inside connection of superior quality complete all as specified and as directed.
S&F desert cooler grasspad suitable for cooler of capacity 4000 cum/hrs & dimension of pad not less than complete all as sepcified and directed.
M&L for painting of cabinet body of room cooler with one coat of red oxide paint and two coats for desert cooler water tank with black enameled paint and outer body with smoke grey paint after preparation of surface complete all as specified and as directed.
Water supply
Taking up or down CI Pipes including all fittings such as spigot and socket ends, bends, belows tee etc laid complete in trenches all as specififed of sizes :-
(a) 80mm bore
(b) 100mm bore
(c ) 150mm bore,
(d) 200mm bore
Supply, Laying and Testing of cast iron pipes with spigot and socket ends and centrifugally cast class LA, in any length, laid in trenches complete all as specified and directed of following sizes :-
(a) 80mm bore
(b) 100mm bore
(c ) 150mm bore
(d) 200mm bore
Laying,refixing and Testing of Old cast iron pipes with , in any length, laid in trenches complete all as specified and directed of following sizes :-
(a) 80mm bore
(b) 100mm bore
(c ) 150mm bore
(d) 200mm bore
Taking up or down steel tubing and connections including all fittings such as bends, belows tee, unions, sockets etc laid complete in trenches all as specififed of sizes :-
(a) 15mm bore
(b) 20mm bore
(c ) 25mm bore
(d) 40mm bore
(e) 50mm bore
(f) 80mm bore
(g) 100mm bore
S & F in repair steel tubing and connections including all fittings such as bends, belows tee, unions, sockets etc laid complete in trenches all as specififed of sizes :-
(a) 15mm bore
(b) 20mm bore
(c ) 25mm bore
(d) 40mm bore
(e) 50mm bore
(f) 80mm bore
(g) 100mm bore
Laying & refixing only in repair steel tubing and connections including all fittings such as bends, belows tee, unions, sockets etc laid complete in trenches all as specififed of sizes :-
(a) 15mm bore
(b) 20mm bore
(c ) 25mm bore
(d) 40mm bore
(e) 50mm bore
(f) 80mm bore
(g) 100mm bore
S & F in replacement Gun metal Gate valve with iron wheel head screwed both ends complete all as specified and as directed by the Engineer-in-Charge of sizes :-
(a) 40 mm dia
(b) 50 mm dia
(c ) 20 mm dia
(d) 25 mm dia
S & F check valve heavy duty of gun metal both end threaded and leaf spring loaded vertical type including removing unserviceable foot valve from the suction pipe of the pump set complete all as specified and directed by Engr in charge of following sizes :-
(a) 100 mm dia
(b) 80 mmm dia
(c) 50 mm dia
S & F in replacement CI non return valve complete all as specified and directed by Engr in charge of following sizes :- .
a) 150 mm dia
b) 100 mm dia
c ) 80 mmm dia
d) 50 mm dia
M & L for Cutting existing CI or steel tubing of any size for alterations or additions and screwing all as specified and directed by Engg-in-charge
Demolition of existing valve pit and M&L for construction of valve pit consisisting of 230mm thick, old size brick masonry wall in cement mortar (1:6), PCC (1:4:8) type D2, using 40mm graded stone aggregete as in fondation, PCC (1:2:4) type B1, using 20mm graded stone aggregete in coping/bed, finished even and smooth, rendering 15mm thick in cement mortar (1:6) internally and 10mm thick in cement mortar (1:4) externally, finished even and smooth without using extra cement incuding three coats of white wash and earth work in any type of soil and including 3mm thick MS sheet cover fixed on 40mmx40mmx6mm thick angle iron frame ambeded in PCC coping with locking arrangement and mild steel hold fast & handle and duly painted with two coats of synthetic enamel paint over one coat of primer etc. complete all as shown on drawing NO TD/2004/26 Sh 1/1 to 1/3 and as specified and directed for the following sizes:-
(a) 900mm x 750mm x 900mm
(b) 900mm x 600mm x 1000mm
S & F in replacement Cast Iron sluice valve, class PN- 1.6 with flanged and drilled ends any pattern including necessary jointing and jointing materials complete (with rubber gaskets, bolts and nuts etc) complete all as specified and directed by Engr in charge including taking down the old worn out sluice valve complete all as specified and directed by Engr in charge for the following sizes :-
(a) 150 mm dia
(b) 100 mm dia
(c ) 80 mm dia
M&L for rectification of defective run lead joing by burning out lead joint in position including recovering lead and making new lead joint all as specified including bailing out water coming from defective joints by means of electric/diesel driven pump set, testing of the joint under full working pressure for the following CI Pipe lines all as directed by Engineer-in-charge.
M&L for rectification of defective rubber gasket flanged joints including replacing rubber gasket, bolts, nuts and washers for the following CI/MS pipe line.
(a) 200/150 mm dia
(b) 100/80 mm dia
S&F cable copper flexible 3 Core cicular type 2.5 sqmm heavy duty complete all as specified and directed.
S&F cable copper flexible 3 Core cicular type 4 sqmm heavy duty complete all as specified and directed.
S & F heavy duty PVC cable 1100 volts grade , insulated aluminium multi stranded conductor, twin core wire of size 4 sqmm complete all as specified and as directed.
S & F heavy duty PVC cable , 1100 volts grade insulated aluminium multi stranded conductor, twin core wire of size 6 sqmm complete all as specified and as directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exeeding 1.5 m deep, getting out the excavated earth bottom surface to required gradient complte all as specified and directed. Note:- (i) Serviceable bricks shall be stacked for reuse and Old unservicable bricks shall be sold to contractor under Sch of credit. (ii) Existing sand cushioning shall not be removed. (iii) In case different strata is met with during excavation, contractor shall not claim extra on this account.
Returning filling in, and including spreading and leveling in layers not exceeding 25 cm thick complete all as specified & directed.
M&L Removal of excavated material such as soils n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.16 MB
TenderDocuments154.pdf
Tender Documents • 0.63 MB
BOQ_844806.xls
BOQ • 1.00 MB
Download all tender documents and submit your bid