Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹78.5 LAccepted-AOC | ₹78.5 L Quoted ₹69.0 L | L1 | Accepted-AOC L1 BIDDER |
| 2 | Rejected-Technical CHANDBALI | - | - | Rejected-Technical L2 BIDDER |
| 3 | Rejected-Technical | - | - | Rejected-Technical L2 bidder |
| 4 | Rejected-Technical | - | - | Rejected-Technical L2 BIDDER |
| 5 | Rejected-Technical | - | - | Rejected-Technical L2 bidder |
Tender Value
₹76.6 L
EMD Value
₹76,639
Closing Date
28 Nov 2025, 5:00 pmClosed
EXECUTIVE ENGINEER L.I.DIVISION,KENDRAPARA
OFFICE OF THE EXECUTIVE ENGINEER L.I.DIVISION,KENDRAPARA AT/PO-TINIMUHANI
Papaer cost/RC/PAN/GST/Joint Venture/HT license/Esxperience with other documents as per DTCN
2025_OLIC_121665_22
1173/LID/KDP/2025-25
Open Tender
Civil Works - Lift Irrigation Schemes
KENDRAPARA
Please refer Tender documents.
2 documents required · 2 mandatory
₹11,800
₹76,639
Yes
18 Feb 2026
21 Nov 2025
29 Nov 2025
21 Nov 2025
28 Nov 2025
21 Nov 2025
21 Nov 2025 - 27 Nov 2025
SCHEDULE-A(SIHAPADA-VI) Earth work in excavation in hard soil in foundation including dressing & leveling of bed within 50 mtr. initial lead & 1.5 mtr. lift In complete.
Earth work in excavation of foundation in hard soil suh as Hard stiff clay,stiff black cotton,shales, morum, ordinary gravels etc within 50 mtr. initial lead & 1.5 mtr.lift Including rough dressing and leveling the bed and depositing the exaveted materials within initial lead at nearby the worksite for reuse including breaking clods and stacking rubble for spreading and leveling as the case may be etc complete. (Exavation by mechanical means 60% & manualy 40%)
Filling in foundation & plinth with sand including watering & ramming etc complete as per the direction of the Engineer-incharge.
Cement concrete (1:4:8) with 4cm size h.g.b. hand broken metal of approved quality from approved quarry with ramming watering and curring etc. complete including cost, taxes, royalty convence charge of all worksite, supply of cement T&Pmaterial to required etc. complete as per the direction of the Engineer-incharge.
Cement concrete (1:2:4) with 12mm size black C.B. hand broken chips of approved quality from approved quarry for R.C.C work with ramming watering and curring etc. complete including convence charge of all material tocost, taxes, royalty worksite, supply of cement T&P required etc complete as per the direction of the Engineer-incharge.
Brick work with Flyash Brick 25cm x 12cm x 8cm size having crushing strength not less than 75kg / cm2 with dimensional tolerrance + 8% in cement mortar (1:6) in foundation & plinth etc. complete as per the Engineer-incharge.
12mm cement plaster in cement mortar (1:6) finished smooth to brick work after racking out joints including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge.
Rigid smooth centering & shuttering for R.C.C. Works walls & fins including false work & dismateling then after including cost of materials in ground floor complete an directed by the Engineer-incharge.
Brick work with Flyash . Brick 25cm x 12cm x 8cm size for Supper Structure having crushing strength not less than 75kg / cm2 with dimensional tolerrance + 8% in cement mortar (1:6) in foundation & plinth etc. complete as per the Engineer-incharge.
Labour charge for M.S. Reinforcement for R.C.C. work including cutting, bending & typing the grills & placing in position including cost of binding wire 18 to 20 guage per Qntl. Including cost of HYSD Steel Bar (FE 415/ FE 500)
Cement punning over plastering including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge.
Filling F&P with excavated materials, including watering and ramming.
Filling F&P with excavated materials, in layers not exceding 0.30m including breaking clods within 50m initial lead including levling the tranches as the case may be etc comlete. ( Quantity by means of Mechanical 60% & manually 40%)
Writing charge of required information and data on both side of the transperancy pillar including supplying of approved paints and required material for writing etc. complete as per the direction of the Engineer-incharge.
Fitting of un plasticised 250mm dia HDPE Pipe for following inside dia mtr. for all classes of pipe including jointing the pipe with solvent cement by non- head application method including fitting and fixing of required no. of PVC Tee for outlet and PVC Shaddle and PVC Riser nipple for fitting air valve, equal Tee etc. complete including conveyance pipe from factory to worksite and testing of pipe line etc. complete as per the direction of the Engineer-incharge.
Fitting of un plasticised 160mm dia HDPE Pipe for following inside dia mtr. for all classes of pipe including jointing the pipe with solvent cement by non- head application method including fitting and fixing of required no. of PVC Tee for outlet and PVC Shaddle and PVC Riser nipple for fitting air valve, equal Tee etc. complete including conveyance pipe from factory to worksite and testing of pipe line etc. complete as per the direction of the Engineer-incharge.
Labour charges for installation of 10HP Motor including fitting & fixing of base frame, fitting & fixing suction and delivery pipe to motor, NR Valve, Foot Valve, Sluice Valve and other fitting materials including cutting, welding etc complete as per the direction of the Engineer-incharge.
Distempering two coats to walls with distemper of approved shade including cost & labour charges.
Painting two coats with approved paint including cost & Labour charges
Finishing walls with water proofing cement paint including cost & Labour charges.
Cost of primer with of approved quqlity & Labour charge for painting Door & Window
Cost of paint with approved quality Labour charge for painting Door & Window
pump chamber wiring with supplying all materials & labour chages as per direction Engineer in charges.
Cost of Febricated M/S Door ( 6'.6''X3'.3") & Window (2'X2') made up with 4mm size C.R Sheet & 1''X1'' M.S Angle incluing fitting fixing etc.as per direction Engineer in charge.
Provision construction of oulet with supplying all materials & Labour etc.
Costof construction febricated GI supporting piller including all fittings complite
100 mm Ø nominal bore G.I. Pipe having wall thickness 4.5 mm electrical resistance welded of medium class confirming to IS - 1239 (pt-1 of 2004) with socketed at one end and the other end protected with plastic thread protector. The socket confirming to IS-1239 (pt-II/1992) with latest amendmewnts in random length of 4 to 7 mtrs. Each pipe should bear ISI certification & manufacturers name /Trade mark.
100mm G.I. Bend conf. to IS no 1239(Part-II/1992)
100 mm Ø C.I. Foot Valve should be of swing type friction less with single disc confirming to IS – 4038/1979 of reputed brand
100mm dia G.I. Flange IS no.6392/1971
Monoblock pump set total head of 18 mtrs capable to discharge 1700 LPM with 10HP/7.5KW squirrel cage induction motor fitted with bronze impeller TB-2 of IS 318/1981, companion flanges & Class "F"insulation suitable for operation 415 volt +6%-15% 3 phase, 50Hz AC poweer supply suction/deliveery =100mmx100mm with BEE Star rated energy efficiency Pump & as per IS-9079/2002 with overall efficiency 62 to 65% of reputed brand having wide dealership net work for easy availability of spares including PTL Testing.
Supplying of 250mm dia unplasticised rigid HDPE PIPE PE 80-PN 4 having specific gravity of 1.40 to 1.46 gms/cc of straight length of 6 (six) meter for portable water supplies conforming to IS - 4985 / 2000 of BIS -Amendment - 2 read with Table - 1 of IS - specification bearing ISI marks for working pressure CI - I HDPE pipe to withstand pressure of 2.5 kgf/sqcm & the specification and manufacturer name should be prominently marked on body of each pipe as per the latest Amendment of IS - 4985. It includes the cost of sockets in case of plain ended pipe. PDI test are to be condcuted and should be marked on body of each pipe and report is to be obtained from CIPET, Bhubaneswar necessary approval of authority including transportation to work site in complete shape.
Supplying of 160mm dia unplasticised rigid HDPE PIPE PE 80-PN 4 having specific gravity of 1.40 to 1.46 gms/cc of straight length of 6 (six) meter for portable water supplies conforming to IS - 4985 / 2000 of BIS -Amendment - 2 read with Table - 1 of IS - specification bearing ISI marks for working pressure CI - I HDPE pipe to withstand pressure of 2.5 kgf/sqcm & the specification and manufacturer name should be prominently marked on body of each pipe as per the latest Amendment of IS - 4985. It includes the cost of sockets in case of plain ended pipe. PDI test are to be condcuted and should be marked on body of each pipe and report is to be obtained from CIPET, Bhubaneswar necessary approval of authority including transportation to work site in complete shape.
100mm Non-return valve C I double flanged swing type PN - 1.0 as per IS:5312 part-I with by-pass arrangement
50 mm Ø Air release valve with saddle & Raiser pipe. The air release valve shall confirm to IS 14845 with ISI mark.
250 mm x250 mm x160 mm Ø HDPE Tee
160 mm x160 mm x160 mm Ø HDPE Equal Tee
250 mm Ø HDPE End Cap
160 mm Ø HDPE End Cap
200x100x100 dia MS 'Y' joint
Supply of solvent cement of approve quality for joiniting of HDPE Pipe with all cost and all tax etc. complete as per the direction of the Engineer-incharge.
100 x100x50 mm dia G.I. priming Tee
200 mm x200 mm x100 mm Ø G.I.Raiser Tee set with bend , closing and opening arrangement.
Control Pannel with Automatic Star delta Starter, sheet steel enclosure suitable for operation of Squirrel cage induction motor up to 10 HP with 16 Amp (AC -3) duty contractor at 415 Volt+6%-15%, 3 phase, 50 Hz AC supply with over load relay range 6.00 to 9.50 Amp & no volt coil with electronic timer suitable for operation at voltage range of 300 to 440 V. The Starter should provide dependable protection against over load and single phasing fitted with Volt meter,Ameter,MCB in complete shape including Indicator Lamp
63 Amp Main Switch Triple pole & neutral of voltage range 440 volt of re-wirable fuse and shall confirm to IS 4064 part I & with ISI mark.
Base frame for motor (size 0.50mx0.27m) made with 3" size M.S. channel having suitable holes for fittings of different size and make 3 fittings of different size and make 3 phase centrifugal monoblock pump set from 10 H.P. to 15 H.P. coloured with one coat of red oxide primer & two coats of smoke grey enamel paint.
Motor hood size (0.45mx0.45mx0.60m) made with 18 SWG (cold rolled M.S.Sheet with one coat of red oxide primer and two coats of smoke gray /navey blue enamel n both side (inside & outside) suitable to cover centrifugal monoblock Pump Set from 10 HP to 15 HP and having provision for attachement with the groves on rear side of the pannel board.
4KVA Capacitor as per IS specification
3 x 10 sqmm Tarpodar cable XLPE (Cross link polyethylin) conforming to IS: 7098 (Part-II) including laying below .9mtr. of the ground and filling the excavated materials including watering and ramming.
3 Ø - 4 wire 20 - 100 Amp. 3 x 230 Volt (P-N) current meter with ISI mark as approved and tested by DISTCO with matching fibre glass & T.P Box.
110 mm dia PVC FTA
200 x 100 mm dia mm dia PVC reducer
Cost of 150mm dia Butterfly valve
Post test of PVC Pipe
Cost of 1 set DE spanner & Hand gloves-1 pair
SCHEDULE-B(SIHAPADA-VI) Construction of 3 phase 11KV line as per REC standard confirming to RE Rules 1956 with 300 kg 10 mtr long PSC pole support in 40M span, with required nos interposing PSC pole (300KG 9 MTR ) , 55 Sqmm AAA Conductor,11 KV "V" Cross arm,with required No.of 11 KV T& C Disc.Insulators & 11 KV Pin insulators,Couping & Padding of Poles. Danger Board at each Pole,Anti Climbing Devices,Stay Set at Bending point & double stay at end point with 18mm G.I.H.T. Stay, concerting of Pole & Stay with Anchor plate,guarding at Road Crossing, with construction cut points etc satisfacying to the estimate provision of TPCODL including cost of all materials,labour transportation, errection, inspection & commissioning etc. complete as per direction of Engineer-in -Charge as per the estimate of TPCODL
Construction and erection of 11/0.4KV ,25KVA D.P. Substation confirming RERules1956,mounted on 2.80mtr Long channel2nos,supported in 300 Kg 9mtr long PSC pole 2nos alongwith AB switch, HG fusemountingchannel, cantiliver channel, Tranaformer belting with 2.80mtr long angle 2nos,insulator, hard wire fitting, lightning arrestor-3nos , stay accessories danger board, provision for anti climbing devices to D.P. ,LT distribution box with kit kat fuse with MCCB 25 KVA *** rated tansformer ,35mm2 x3 1/2 core PVC cable and other materials required ,earthing with G.I. pipe , G.I. wire and G.I. flat and other materials like nut bolt, washer etc.,socket with concreting of poles and stay including fencing boundary wall with G.I.Flat ( Size 5mtrX 3mtr X 1.5mtr ) & M.S Grill Gate , Sand filling and metal spreading / concretaing around the S/S ,fixing of iron gate etc. including cost of all materials, labour, transportation ,errection, testing and commissioning & inspection etc. as per direction of Engineer-in -charge as per estimate of TPCODL
Electrical Installation including labour charges for fitting of Control Pannel ,danger board,capacitor ,wiring of motor and laying of T.D. cable in underground trench including Power supply commissioning etc. complete so as to energised the pumpset as per design and drawing of OLIC as per direction of Engineer-in-charge
40mm dia G.I.pipe earthing(2nos) for Pump and Pannel board near fixed foundation using 18gauge G.I. wire including all labour and required materials i.e. G.I.Socket charcoal ,salt,small size huts & bolts and any other petty items as required in the field including excavation of earth pits and fitting thereoff in complete as per the direction of Engineer-in charge
Construction of 90 degree cutpoint angle with 10 mtr PSC Pole with required materials like Disc insulator , Pin Insulator , Polymer , angles & cross arm etc as per specification & Estimate of TPCODL.
Construction of 180 degree cutpoint angle with 10 mtr PSC Pole with required materials like Disc insulator , Pin Insulator , Polymer , angles & cross arm etc as per specification & Estimate of TPCODL.
SCHEDULE-A(SIHAPADA-VII) IEarth work in excavation in hard soil in foundation including dressing & leveling of bed within 50 mtr. initial lead & 1.5 mtr. lift In complete.
Earth work in excavation of foundation in hard soil suh as Hard stiff clay,stiff black cotton,shales, morum, ordinary gravels etc within 50 mtr. initial lead & 1.5 mtr.lift Including rough dressing and leveling the bed and depositing the exaveted materials within initial lead at nearby the worksite for reuse including breaking clods and stacking rubble for spreading and leveling as the case may be etc complete. (Exavation by mechanical means 60% & manualy 40%)
Filling in foundation & plinth with sand including watering & ramming etc complete as per the direction of the Engineer-incharge.
Cement concrete (1:4:8) with 4cm size h.g.b. hand broken metal of approved quality from approved quarry with ramming watering and curring etc. complete including cost, taxes, royalty convence charge of all worksite, supply of cement T&Pmaterial to required etc. complete as per the direction of the Engineer-incharge.
Cement concrete (1:2:4) with 12mm size black C.B. hand broken chips of approved quality from approved quarry for R.C.C work with ramming watering and curring etc. complete including convence charge of all material tocost, taxes, royalty worksite, supply of cement T&P required etc complete as per the direction of the Engineer-incharge.
Brick work with Flyash Brick 25cm x 12cm x 8cm size having crushing strength not less than 75kg / cm2 with dimensional tolerrance + 8% in cement mortar (1:6) in foundation & plinth etc. complete as per the Engineer-incharge.
12mm cement plaster in cement mortar (1:6) finished smooth to brick work after racking out joints including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge.
Rigid smooth centering & shuttering for R.C.C. Works walls & fins including false work & dismateling then after including cost of materials in ground floor complete an directed by the Engineer-incharge.
Brick work with Flyash . Brick 25cm x 12cm x 8cm size for Supper Structure having crushing strength not less than 75kg / cm2 with dimensional tolerrance + 8% in cement mortar (1:6) in foundation & plinth etc. complete as per the Engineer-incharge.
Labour charge for M.S. Reinforcement for R.C.C. work including cutting, bending & typing the grills & placing in position including cost of binding wire 18 to 20 guage per Qntl. Including cost of HYSD Steel Bar (FE 415/ FE 500)
Cement punning over plastering including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge.
Filling F&P with excavated materials, including watering and ramming.
Filling F&P with excavated materials, in layers not exceding 0.30m including breaking clods within 50m initial lead including levling the tranches as the case may be etc comlete. ( Quantity by means of Mechanical 60% & manually 40%)
Writing charge of required information and data on both side of the transperancy pillar including supplying of approved paints and required material for writing etc. complete as per the direction of the Engineer-incharge.
Fitting of un plasticised 200mm dia HDPE Pipe for following inside dia mtr. for all classes of pipe including jointing the pipe with solvent cement by non- head application method including fitting and fixing of required no. of PVC Tee for outlet and PVC Shaddle and PVC Riser nipple for fitting air valve, equal Tee etc. complete including conveyance pipe from factory to worksite and testing of pipe line etc. complete as per the direction of the Engineer-incharge.
Fitting of un plasticised 160mm dia HDPE Pipe for following inside dia mtr. for all classes of pipe including jointing the pipe with solvent cement by non- head application method including fitting and fixing of required no. of PVC Tee for outlet and PVC Shaddle and PVC Riser nipple for fitting air valve, equal Tee etc. complete including conveyance pipe from factory to worksite and testing of pipe line etc. complete as per the direction of the Engineer-incharge.
Labour charges for installation of 10HP Motor including fitting & fixing of base frame, fitting & fixing suction and delivery pipe to motor, NR Valve, Foot Valve, Sluice Valve and other fitting materials including cutting, welding etc complete as per the direction of the Engineer-incharge.
Distempering two coats to walls with distemper of approved shade including cost & labour charges.
Painting two coats with approved paint including cost & Labour charges
Finishing walls with water proofing cement paint including cost & Labour charges.
Cost of primer with of approved quqlity & Labour charge for painting Door & Window
Cost of paint with approved quality Labour charge for painting Door & Window
pump chamber wiring with supplying all materials & labour chages as per direction Engineer in charges.
Cost of Febricated M/S Door ( 6'.6''X3'.3") & Window (2'X2') made up with 4mm size C.R Sheet & 1''X1'' M.S Angle incluing fitting fixing etc.as per direction Engineer in charge.
Provision construction of oulet with supplying all materials & Labour etc.
Costof construction febricated GI supporting piller including all fittings complite
100 mm Ø nominal bore G.I. Pipe having wall thickness 4.5 mm electrical resistance welded of medium class confirming to IS - 1239 (pt-1 of 2004) with socketed at one end and the other end protected with plastic thread protector. The socket confirming to IS-1239 (pt-II/1992) with latest amendmewnts in random length of 4 to 7 mtrs. Each pipe should bear ISI certification & manufacturers name /Trade mark.
100mm G.I. Bend conf. to IS no 1239(Part-II/1992)
100 mm Ø C.I. Foot Valve should be of swing type friction less with single disc confirming to IS – 4038/1979 of reputed brand
100mm dia G.I. Flange IS no.6392/1971
Monoblock pump set total head of 18 mtrs capable to discharge 1700 LPM with 10HP/7.5KW squirrel cage induction motor fitted with bronze impeller TB-2 of IS 318/1981, companion flanges & Class "F"insulation suitable for operation 415 volt +6%-15% 3 phase, 50Hz AC poweer supply suction/deliveery =100mmx100mm with BEE Star rated energy efficiency Pump & as per IS-9079/2002 with overall efficiency 62 to 65% of reputed brand having wide dealership net work for easy availability of spares including PTL testing
Supplying of 200mm dia unplasticised rigid HDPE PIPE PE 80-PN 4 having specific gravity of 1.40 to 1.46 gms/cc of straight length of 6 (six) meter for portable water supplies conforming to IS - 4985 / 2000 of BIS -Amendment - 2 read with Table - 1 of IS - specification bearing ISI marks for working pressure CI - I HDPE pipe to withstand pressure of 2.5 kgf/sqcm & the specification and manufacturer name should be prominently marked on body of each pipe as per the latest Amendment of IS - 4985. It includes the cost of sockets in case of plain ended pipe. PDI test are to be condcuted and should be marked on body of each pipe and report is to be obtained from CIPET, Bhubaneswar necessary approval of authority including transportation to work site in complete shape.
Supplying of 160mm dia unplasticised rigid HDPE PIPE PE 80-PN 4 having specific gravity of 1.40 to 1.46 gms/cc of straight length of 6 (six) meter for portable water supplies conforming to IS - 4985 / 2000 of BIS -Amendment - 2 read with Table - 1 of IS - specification bearing ISI marks for working pressure CI - I HDPE pipe to withstand pressure of 2.5 kgf/sqcm & the specification and manufacturer name should be prominently marked on body of each pipe as per the latest Amendment of IS - 4985. It includes the cost of sockets in case of plain ended pipe. PDI test are to be condcuted and should be marked on body of each pipe and report is to be obtained from CIPET, Bhubaneswar necessary approval of authority including transportation to work site in complete shape.
100mm Non-return valve C I double flanged swing type PN - 1.0 as per IS:5312 part-I with by-pass arrangement
50 mm Ø Air release valve with saddle & Raiser pipe. The air release valve shall confirm to IS 14845 with ISI mark.
200 mm x200 mm x1600 mm Ø HDPE Tee
160 mm x160 mm x160 mm Ø HDPE Equal Tee
200 mm Ø HDPE End Cap
1600 mm Ø HDPE End Cap
Supply of solvent cement of approve quality for joiniting of HDPE Pipe with all cost and all tax etc. complete as per the direction of the Engineer-incharge.
100 x100x50 mm dia G.I. priming Tee
200 mm x200 mm x100 mm Ø G.I.Raiser Tee set with bend , closing and opening arrangement.
Control Pannel with Automatic Star delta Starter, sheet steel enclosure suitable for operation of Squirrel cage induction motor up to 10 HP with 16 Amp (AC -3) duty contractor at 415 Volt+6%-15%, 3 phase, 50 Hz AC supply with over load relay range 6.00 to 9.50 Amp & no volt coil with electronic timer suitable for operation at voltage range of 300 to 440 V. The Starter should provide dependable protection against over load and single phasing fitted with Volt meter,Ameter,MCB in complete shape including Indicator Lamp
63 Amp Main Switch Triple pole & neutral of voltage range 440 volt of re-wirable fuse and shall confirm to IS 4064 part I & with ISI mark.
Base frame for motor (size 0.50mx0.27m) made with 3" size M.S. channel having suitable holes for fittings of different size and make 3 fittings of different size and make 3 phase centrifugal monoblock pump set from 10 H.P. to 15 H.P. coloured with one coat of red oxide primer & two coats of smoke grey enamel paint.
Motor hood size (0.45mx0.45mx0.60m) made with 18 SWG (cold rolled M.S.Sheet with one coat of red oxide primer and two coats of smoke gray /navey blue enamel n both side (inside & outside) suitable to cover centrifugal monoblock Pump Set from 10 HP to 15 HP and having provision for attachement with the groves on rear side of the pannel board.
4KVA Capacitor as per IS specification
3 x 10 sqmm Tarpodar cable XLPE (Cross link polyethylin) conforming to IS: 7098 (Part-II) including laying below .9mtr. of the ground and filling the excavated materials including watering and ramming.
3 Ø - 4 wire 20 - 100 Amp. 3 x 230 Volt (P-N) current meter with ISI mark as approved and tested by DISTCO with matching fibre glass & T.P Box.
110 mm dia PVC FTA
200 x 100 mm dia mm dia PVC reducer
Cost of 150mm dia Butterfly valve
Cost of DE spanner-1 set & Hand gloves-1 pair
Post test of PVC Pipe
SCHEDULE-B(SIHAPADA-VII) Construction of 3 phase 11KV line as per REC standard confirming to RE Rules 1956 with 300 kg 10 mtr long PSC pole support in 40M span, with required nos interposing PSC pole (300KG 9 MTR ) , 55 Sqmm AAA Conductor,11 KV "V" Cross arm,with required No.of 11 KV T& C Disc.Insulators & 11 KV Pin insulators,Couping & Padding of Poles. Danger Board at each Pole,Anti Climbing Devices,Stay Set at Bending point & double stay at end point with 18mm G.I.H.T. Stay, concerting of Pole & Stay with Anchor plate,guarding at Road Crossing, with construction cut points etc satisfacying to the estimate provision of TPCODL including cost of all materials,labour transportation, errection, inspection & commissioning etc. complete as per direction of Engineer-in -Charge as per the estimate of TPCODL
Construction and erection of 11/0.4KV ,25KVA D.P. Substation confirming RERules1956,mounted on 2.80mtr Long channel2nos,supported in 300 Kg 9mtr long PSC pole 2nos alongwith AB switch, HG fusemountingchannel, cantiliver channel, Tranaformer belting with 2.80mtr long angle 2nos,insulator, hard wire fitting, lightning arrestor-3nos , stay accessories danger board, provision for anti climbing devices to D.P. ,LT distribution box with kit kat fuse with MCCB 25 KVA *** rated tansformer ,35mm2 x3 1/2 core PVC cable and other materials required ,earthing with G.I. pipe , G.I. wire and G.I. flat and other materials like nut bolt, washer etc.,socket with concreting of poles and stay including fencing boundary wall with G.I.Flat ( Size 5mtrX 3mtr X 1.5mtr ) & M.S Grill Gate , Sand filling and metal spreading / concretaing around the S/S ,fixing of iron gate etc. including cost of all materials, labour, transportation ,errection, testing and commissioning & inspection etc. as per direction of Engineer-in -charge as per estimate of TPCODL
Electrical Installation including labour charges for fitting of Control Pannel ,danger board,capacitor ,wiring of motor and laying of T.D. cable in underground trench including Power supply commissioning etc. complete so as to energised the pumpset as per design and drawing of OLIC as per direction of Engineer-in-charge
40mm dia G.I.pipe earthing(2nos) for Pump and Pannel board near fixed foundation using 18gauge G.I. wire including all labour and required materials i.e. G.I.Socket charcoal ,salt,small size huts & bolts and any other petty items as required in the field including excavation of earth pits and fitting thereoff in complete as per the direction of Engineer-in charge
Construction of 90 degree cutpoint angle with 10 mtr PSC Pole with required materials like Disc insulator , Pin Insulator , Polymer , angles & cross arm etc as per specification & Estimate of TPCODL.
Construction of 180 degree cutpoint angle with 10 mtr PSC Pole with required materials like Disc insulator , Pin Insulator , Polymer , angles & cross arm etc as per specification & Estimate of TPCODL.
stage.html
html • 0.06 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_566205.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.75 MB
Tendernotice_2.pdf
PDF • 5.88 MB
BOQ_566205.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid