| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-AOC | ₹27.9 L Quoted ₹28.3 L | L1 | Accepted-AOC Being Lowest Tenderer |
| 2 | L2₹32.3 L+₹4.0 L (14.1%)Rejected-Finance 1 14 SUJAL MANSION B BLOCK BHANGWADI KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | ₹32.3 L+₹4.0 L (14.1%) | L2 | Rejected-Finance Being other than Lowest Tenderer |
| 3 | L3₹33.1 L+₹4.8 L (16.9%)Rejected-Finance ROOM NO 680 GANESH MURTY NAGAR PART NO 03 CAPT PRAKASH PETHE MARG COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | ₹33.1 L+₹4.8 L (16.9%) | L3 | Rejected-Finance Being other than Lowest Tenderer |
| 4 | L4₹35.0 L+₹6.7 L (23.6%)Rejected-Finance | ₹35.0 L+₹6.7 L (23.6%) | L4 | Rejected-Finance Being other than Lowest Tenderer |
| 5 | L5₹38.6 L+₹10.2 L (36.1%)Rejected-Finance GANESH MURTHI NAGAR PART III GALI NO 01 ROOM NO 82 A CAPT PRAKASH PETHE MARG CUFF PARADE ROAD COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | ₹38.6 L+₹10.2 L (36.1%) | L5 | Rejected-Finance Being other than Lowest Tenderer |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
17 Apr 2024, 6:55 pmClosed
MAJOR ANIL KUMAR S GE NW KUNJALI
GARRISON ENGINEER NW KUNJALI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI 400005
8983 REPAIR MAINT OF LIGHTING TOWER WATER PROOF LIGHTS FLOOD LIGHTS AND ALL PAINTING LT PANELS COPE POINTS AND SWITCH GEAR AT VARIOUS JETTIES WHARFS AT ND UNDER GE NW KUNJALI
2024_MES_648099_1
8983/E8
Open Tender
Civil Works
Item Rate
183 days
GE (NW) KUNJALI
ALL AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE (NW) KUNJALI
₹98,000
Yes
15 May 2025
28 Mar 2024
19 Apr 2024
2 Apr 2024
17 Apr 2024
3 Apr 2024
28 Mar 2024 - 2 Apr 2024
Amount
M & L for scrapping of old paint from tower (Approx Height 60 Mtrs) and leveling the surface with sand paper including making the area clean and all as directed Note :- (a) M & L for painting of 01 coat of red Oxide metal primer with proper safety precations unsing scaffolding and safety belt (b) M & L for painting of 02 coat of aluminium color paint with proper safety precations using scaffolding and safety belt Location Near SBW Jetty Tower No-01 - Make of paint:-Asian Paint/Berger/Nerolac/Indigo
M & L for scrapping of old paint from tower (Approx Height 40 Mtrs) and leveling the surface with sand paper including making the area clean and all as directed Note :- (a) M & L for painting of 01 coat of red Oxide metal primer with proper safety precations unsing scaffolding and safety belt (b) M & L for painting of 02 coat of aluminium color paint with proper safety precations using scaffolding and safety belt Location Nacal Point (Near CCDT Bldg-01 & Cruiser Wharf-01 Make of paint:- Asain Paint/Berger/Nerolac/Indigo
M & L for scrapping of old paint from tower (Approx Height 30 Mtrs) and leveling the surface with sand paper including making the area clean and all as directed Note :- (a) M & L for painting of 01 coat of red Oxide metal primer with proper safety precations unsing scaffolding and safety belt (b) M & L for painting of 02 coat of aluminium color paint with proper safety precations using scaffolding and safety belt Make Asain Paint/Berger/Nerolac/Indigo
M & L for scrapping of old paint from Flag Post Pole (Approx Height 30 Mtrs) and leveling the surface with sand paper including making the area clean and all as directed Note :- (a) M & L for painting of 01 coat of red Oxide metal primer with proper safety precations unsing scaffolding and safety belt (b) M & L for painting of 02 coat of White color paint with proper safety precations using scaffolding and safety belt Loc Near Fleet office Bldg -01 . Make of paint:- Asain Paint/Berger/Nerolac/Indigo
M&L for Scraping old paint from High Mast light poles by wire brush not more than from 10 Mtrs 15 mtr length above ground level including street light arm applying one coat of steel primer and two coat of aluminium paint and marking pole No With Size 06 inch x 6 inch sticker complete all as specified and directed.
M&L for Scraping old paint from steel tubular poles by wire brush not more than up to 9.0 mtr length above ground level including street light arm applying one coat of steel primer and two coat of aluminium paint and marking pole No With Size 06 inch x 6 inch sticker complete all as specified and directed.
M&L for Scraping old paint from Heritage poles by wire brush not more than up to 06 mtr length above ground level including street light arm applying one coat of steel primer and two coat of aluminium paint and marking pole No With Size 06 inch x 6 inch sticker complete all as specified and directed.
M&L for Scraping old paint from Bollard poles by wire brush not more than up to 02 mtr length above ground level including street light arm applying one coat of steel primer and two coat of aluminium paint and marking pole No With Size 06 inch x 6 inch sticker complete all as specified and directed.
Decorbonising /cleaning/ Painting of LT Panel (AC) 415/380V, 50 HZ 3 phase bus bar, bus bar chambers of feeder pillar box, electrical connection complete, ACB, switch fuse unit arrangement incoming & outgoing installed in at various location after removing the complete bus bar from the bus chamber, cleaning with CTC & insure proper decorbonising refixing the same applying backtal (red) solution to the bus bar insulator & checking all the connections & tighting the nuts & bolts thimbles of incoming & out going system Removing & repositioning of RCC/MS duct covers including two coat of Signal red oxide and one coat of black paint as required complete including replacement of defective rusted bolts, nuts & washers all as specified & directed.
Decorbonising /cleaning/ Painting of LT Panel (AC) 415/380V, 60 HZ 3 phase bus bar, bus bar chambers of feeder pillar box, electrical connection complete, ACB, switch fuse unit arrangement incoming & outgoing installed in at various location after removing the complete bus bar from the bus chamber, cleaning with CTC & insure proper decorbonising refixing the same applying backtal (red) solution to the bus bar insulator & checking all the connections & tighting the nuts & bolts thimbles of incoming & out going system Removing & repositioning of RCC/MS duct covers including two coat of Phirozi oxide and one coat of black paint as required complete including replacement of defective rusted bolts, nuts & washers all as specified & directed.
Decorbonising /cleaning/ Painting of LT (DC) 415/380V, 50 HZ 3 phase bus bar, bus bar chambers of feeder pillar box, electrical connection complete, ACB, switch fuse unit arrangement incoming & outgoing installed in at various location after removing the complete bus bar from the bus chamber, cleaning with CTC & insure proper decorbonising refixing the same applying backtal (red) solution to the bus bar insulator & checking all the connections & tighting the nuts & bolts thimbles of incoming & out going system Removing & repositioning of RCC/MS duct covers including two coat of Bus Green paint and one coat of black paint as required complete including replacement of defective rusted bolts, nuts & washers complete all as specified and directed.
Decorbonising /cleaning/ Painting of UTL Feeder Pillar 415/380V, 50 HZ 3 phase bus bar, bus bar chambers of feeder pillar box, electrical connection complete, ACB, switch fuse unit arrangement incoming & outgoing installed in at various location after removing the complete bus bar from the bus chamber, cleaning with CTC & insure proper decorbonising refixing the same applying backtal (red) solution to the bus bar insulator & checking all the connections & tighting the nuts & bolts thimbles of incoming & out going system Removing & repositioning of RCC/MS duct covers including two coat of French Blue paint and one coat of black paint as required complete including replacement of defective rusted bolts, nuts & washers complete all as specified and directed.
Decorbonising /cleaning/ Painting of Fresh water feeder Pillar, Removing & repositioning of RCC/MS duct covers including two coat of Sky Blue paint and one coat of black paint as required complete including replacement of defective rusted bolts, nuts & washers complete all as specified and directed.
M & L for scrapping of old paint from Transformer (Capaticy Upto 3000 KVA) and leveling the surface with sand paper including making the area clean and all as directed Note :- (a) M & L for painting of 01 coat of red Oxide metal primer with proper safety precations using scaffolding and safety belt (b) M & L for painting of 02 coat of Smoke Grey color paint with proper safety precations using scaffolding and safety belt complete all as specified and directed. - Make of paint:- Asain Paint/Berger/Nerolac/Indigo
Taking down the LT ACB of capacities 630Amps to 2000Amps of any make for repairs, servicing, comprising the following & refixing the same, re-orientation & labour for taking, defective parts & refixing the same spare parts:- (a) Checking /repairs of the mechanism of ACB (b) Checking/repair of the manual closing of the breakers (c) Decarburizing, setting reassembling, cleaning adjustment of fixed contacts, main contact & chamber and applying petroleum jelly all as complete complete all as specified and directed..
Decorbonising/ cleaning of ducts of HT/LT cable from various location as per following description. (a)Removing of accumulated, stegnated water/oil from the duct either manually or mechanically.(b) Cleaning of cable bunch in duct of all accumulated silt/mud/debris/foreign material. (c) Removing & repositioning of RCC/MS duct covers including one coat of red oxide and one coat of black paint complete all as specified and directed.
S&F in repair FRP looping box 225x295x122mm with locking arrangement, shockproof and rustproof, rot-proof and termite resistance, cable entry from bottom and side, 100% weather proof for outdoor installation suitable for pole mounting, tamper proof, restricts unauthorised tapping, IS 11731, IP 66/67 suitable for 16-35 sqmm 3.5 core aluminium cable including 1 No MCB 2-32 Amp and connector block two way and fixing with flat aluminium clamps not less than 25 mm x 3 mm with suitable size nuts, bolts and washers inside and outside looping box complets as directed.Make : Hensel Cat No: KF 3500H orequivalent make in list of manufactures
S&F in replacement of LED street light 120 W energy saving and envirment friendly light fitting with housed in pressure dia cost aluminium housing with sealed toughened glass cover, SMD LED with secondery lens luminaires with IP 66 protection including all fixing accessories complete all as specified and directed .
S&F in replacement of LED street light 90 W energy saving and envirment friendly light fitting with housed in pressure dia cost aluminium housing with sealed toughened glass cover, SMD LED with secondery lens luminaires with IP 66 protection including all fixing accessories complete all as specified and directed .
S&F in replacement of LED highbay light 200 W energy saving and envirment friendly light fitting, pressure dia cost aluminium housing with aim & adjustable bracket, matt finished reflector for gglare elimination, SMD LED with secondary lens with IP 66 protection including all fixing accessories complete all as specified and directed .
S&F in replacement of LED highbay light 150 W energy saving and envirment friendly light fitting, pressure dia cost aluminium housing with aim & adjustable bracket, matt finished reflector for gglare elimination, SMD LED with secondary lens with IP 66 protection including all fixing accessories complete all as specified and directed .
S&F in replacement of LED highbay light 120 W energy saving and envirment friendly light fitting, pressure dia cost aluminium housing with aim & adjustable bracket, matt finished reflector for gglare elimination, SMD LED with secondary lens with IP 66 protection including all fixing accessories complete all as specified and directed .
Supply and fix in replacement of LED flood lights 400 W energy saving and enviromental friendly light fitting IP 66 high power LED floodlight with pressure die cast aluminium housing complete with all accessories.
Supply and fix in replacement of LED flood lights 350 W energy saving and enviromental friendly light fitting IP 66 high power LED floodlight with pressure die cast aluminium housing complete with all accessories.Make: Bajaj Cat Part No GLEAM F 385 L WH SYPC SD V2 or equivalent make in list of manufactures
Supply and fix in replacement of LED flood lights 250 W energy saving and enviromental friendly light fitting IP 66 high power LED floodlight with pressure die cast aluminium housing complete with all accessories all as specified and directed.
Supply and fix in replacement of LED flood lights 200 W energy saving and enviromental friendly light fitting IP 66 high power LED floodlight with pressure die cast aluminium housing complete with all accessories all as specified and directed.
Supply and fix in replacement of LED flood lights 150 W energy saving and enviromental friendly light fitting IP 66 high power LED floodlight with pressure die cast aluminium housing complete with all accessories and all as specified and directed.
Supply and fix in replacement of LED flood lights 50 W energy saving and enviromental friendly light fitting IP 66 high power LED floodlight with pressure die cast aluminium housing complete with all accessories and complete all as specified and directed.
Supply and erecting of cast iron 3 mtr long Heritage type street light pole with Single Arms duly painted duly fixed with 1 x 20 W LED post top light including excavation, earth work, PCC as in foundation, nuts, bolts, washers of any size complete all as directed. Note: Excavation, Earth work, PCC(1:3:6) type C2 foundation and PCC(1:2:4) type B1 coping etc are deemed to be included in the quoted rate. ii) FRP outdoor loop box alongwith 3 pole connector and 06 amps MCB to be included in the quoted rates
S & F in replacement hot dip galvanized anti corroded weather proof octagonal electric poles 9 Mtrs long top mounting on foundation complete with base plate including PCC foundation as per SSR provision and directed with 1500 mm long arms bracket, tapper plug, bolts, nuts and screws etc as specified complete including taking out existing RCC/damaged rusted MS pole with street light and street light bracket complete all as specified and directed .
S & F in replacement hot dip galvanized anti corroded weather proof octagonal electric poles 15 Mtrs long top mounting on foundation complete with base plate including PCC foundation as per SSR provision and directed with 1500 mm long arms bracket, tapper plug, bolts, nuts and screws etc as specified complete including taking out existing RCC/damaged rusted MS pole with street light and street light bracket complete all as specified and directed .
Supply and fix in replacement MS arms bracket 30 degree bend, 1.5mtr long for mounting one in nos street light fitting including clamps / nut / bolts & washer to brace the same properly with duly painted in synthetic enamel paint of two coat in silver colour complete all as specified and directed .
Supply and Laying 3 core 2.5 Sqmm testing and commissioning PVC round copper conductor (flexible) laid in trenches, passing through pipes, fixed on wall complete including connecting properly by means of thimble and taking out damaged unserviceable cable of the following sizes complete all as specified and directed .
Supply and Laying 3 core 4 Sqmm testing and commissioning PVC round copper conductor (flexible) laid in trenches, passing through pipes, fixed on wall complete including connecting properly by means of thimble and taking out damaged unserviceable cable of the following sizes complete all as specified and directed .
Supply and Laying 3 core 6 Sqmm testing and commissioning PVC round copper conductor (flexible) laid in trenches, passing through pipes, fixed on wall complete including connecting properly by means of thimble and taking out damaged unserviceable cable of the following sizes complete all as specified and directed .
Supply and Laying 4 core 10 Sqmm testing and commissioning PVC round copper conductor (flexible) laid in trenches, passing through pipes, fixed on wall complete including connecting properly by means of thimble and taking out damaged unserviceable cable of the following sizes complete all as specified and directed .
Supply and lay in repair cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of size 10sq mm 4 core. laid in trench/ duct / along pole/wall etc including making connection complete all as directed. Note : 1. The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Supply and Laying 4 core 16 Sqmm testing and commissioning PVC insulated PVC sheathed armoured electric cable with aluminium conductor laid in trenches, passing through pipes, fixed on wall complete including connecting properly by means of thimble and taking out damaged unserviceable cable of the following sizes complete all as specified and directed .
Supply and Laying 3.5 core 25 Sqmm testing and commissioning PVC insulated PVC sheathed armoured electric cable with aluminium conductor laid in trenches, passing through pipes, fixed on wall complete including connecting properly by means of thimble and taking out damaged unserviceable cable of the following sizes complete all as specified and directed .
Supply and Laying 3.5 core 35 Sqmm testing and commissioning PVC insulated PVC sheathed armoured electric cable with aluminium conductor laid in trenches, passing through pipes, fixed on wall complete including connecting properly by means of thimble and taking out damaged unserviceable cable of the following sizes complete all as specified and directed .
Supply and Laying 3.5 core 50 Sqmm testing and commissioning PVC insulated PVC sheathed armoured electric cable with aluminium conductor laid in trenches, passing through pipes, fixed on wall complete including connecting properly by means of thimble and taking out damaged unserviceable cable of the following sizes complete all as specified and directed .
Supply and Laying 4 core 16 Sqmm testing and commissioning PVC insulated and PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694 laid in trenches, passing through pipes, fixed on wall complete including connecting properly by means of thimble and taking out damaged unserviceable cable of the following sizes complete all as specified and directed .
Supply and Laying 4 core 240 Sqmm testing and commissioning PVC insulated and FRLSH PVC Round Sheathed, Copper Conductor (flexible) industrial cable, 1100 Volt, conforming to IS 694 laid in trenches, passing through pipes, fixed on wall complete including connecting properly by means of thimble and taking out damaged unserviceable cable of the sizes complete all as specified and directed .
Excavation in trenches n exc1.5m wide and n exc in depth for laying of cables and getting out in loose/soft soil complete all as specified and directed .
Returing filling in including spreading, levelling watering and well ramming in layers not exc 25cm complete all as specified and directed .
Removing excavated material n exc 50cm and deposting where directed at a level n exc 1.5m above the starting point complete all as specified and directed .
Material and labour for sand filling in trenches fine dry sand as sand cushioning to cable 8 cm before laying of cables and 15 cm after laying cable which shall be punned down to 10 cm complete all as specified and directed. (Note : Only punned down thickness shall be measured and paid)
M&L for un-reinforced,precastmconcet cable cover of size 250x150x40mm class LV typeI for cable protection complete all as specified and directed .
S&F GI tubing light grade 80mm dia with all fittings laid in trenches/fixed on wall/ceiling including dismantling of old pipe etc all as specified and directed.
S&F GI tubing light grade 40mm dia with all fittings laid in trenches/fixed on wall/ceiling including dismantling of old pipe etc all as specified and directed.
Cutting road/hard standing with the help of hammer brake for firing of GI pipe 50mm dia for passing of cable and making good the same to match the existing surface complete all as directed .
Chakshu Enterprise
B P ENTERPRISES
shubham construction
H R Enterprises
NOEL ENGINEERS
SHRI SAI ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .