Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.0 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹29.2 L+₹5,100 (0.18%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L2 | Rejected-Finance Rejected due to bidder not L1 | |
| 3 | L3₹30.4 L+₹1.3 L (4.32%)Rejected-Finance H NO 1346 SECTOR 13 P HISAR 125005 HARYANA | HISAR | HISAR | HARYANA | 125005 | L3 | Rejected-Finance Rejected due to bidder not L1 | |
| 4 | L4₹30.8 L+₹1.7 L (5.67%)Rejected-Finance | L4 | Rejected-Finance Rejected due to bidder not L1 | |
| 5 | L5₹31.6 L+₹2.5 L (8.62%)Rejected-Finance 1ST FLOOR HRECF OFFICE NEAR JNV SCHOOL MIAN GATE TIA RAY RONG CHOGLAMSAR LEH LADAKH 194101 | LEH LADAKH | LADAKH | 194101 | L5 | Rejected-Finance Rejected due to bidder not L1 |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
10 Apr 2020, 6:00 pmClosed
GE 865 EWS
GE 865 EWS
REPAIR MAINT OF LT CABLES MCCBS LT PANELS WITH CONNECTED ACCESSORIES AT SECTOR A AND B UNDER GE 865 EWS
2020_MES_335413_1
865/EWS-155/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 865 EWS
As per NIT
7 documents required · 7 mandatory
₹500
GE 865 EWS
₹78,000
Yes
16 May 2020
19 Mar 2020
13 Apr 2020
19 Mar 2020
10 Apr 2020
2 Apr 2020
Amount
Taking out U/S LT Cable from trench/on wall of any size complete all as specified and directed by Engr in Charge
Supplying, laying, jointing and testing underground cable PVC XLPE insulated armoured and PVC sheathed LT 1100 volts grade (heavy duty) with aluminium conductor 2 core, 6 Sqmm, confirming to IS-1554, laid in ducts/through pipes, in floor, on poles, in trenches complete all as specified. Note :- Clamps, GI pipes, excavation, earth work, sand cushioning and brick protection cover shall be measured and paid for separately.
Supplying, laying, jointing and testing underground cable PVC XLPE insulated armoured and PVC sheathed LT 1100 volts grade (heavy duty) with aluminium conductor 2 core, 10 Sqmm, confirming to IS-1554, laid in ducts/through pipes, in floor, on poles, in trenches complete all as specified. Note :- Clamps, GI pipes, excavation, earth work, sand cushioning and brick protection cover shall be measured and paid for separately.
Supplying, laying, jointing and testing underground cable PVC XLPE insulated armoured and PVC sheathed LT 1100 volts grade (heavy duty) with aluminium conductor 2 core, 16 Sqmm, confirming to IS-1554, laid in ducts/through pipes, in floor, on poles, in trenches complete all as specified. Note :- Clamps, GI pipes, excavation, earth work, sand cushioning and brick protection cover shall be measured and paid for separately.
Supplying, laying, jointing and testing underground cable PVC XLPE insulated armoured and PVC sheathed LT 1100 volts grade (heavy duty) with aluminium conductor 3.5/4 core, 25 Sqmm, confirming to IS-1554, laid in ducts/through pipes, in floor, on poles, in trenches complete all as specified. Note :- Clamps, GI pipes, excavation, earth work, sand cushioning and brick protection cover shall be measured and paid for separately.
Supplying, laying, jointing and testing underground cable PVC XLPE insulated armoured and PVC sheathed LT 1100 volts grade (heavy duty) with aluminium conductor 3.5 core, 35 Sqmm, confirming to IS-1554, laid in ducts/through pipes, in floor, on poles, in trenches complete all as specified. Note :- Clamps, GI pipes, excavation, earth work, sand cushioning and brick protection cover shall be measured and paid for separately.
Supplying, laying, jointing and testing underground cable PVC XLPE insulated armoured and PVC sheathed LT 1100 volts grade (heavy duty) with aluminium conductor 3.5 core, 50 Sqmm, confirming to IS-1554, laid in ducts/through pipes, in floor, on poles, in trenches complete all as specified. Note :- Clamps, GI pipes, excavation, earth work, sand cushioning and brick protection cover shall be measured and paid for separately.
Supplying, laying, jointing and testing underground cable PVC XLPE insulated armoured and PVC sheathed LT 1100 volts grade (heavy duty) with aluminium conductor 3.5 core, 70 Sqmm, confirming to IS-1554, laid in ducts/through pipes, in floor, on poles, in trenches complete all as specified. Note :- Clamps, GI pipes, excavation, earth work, sand cushioning and brick protection cover shall be measured and paid for separately.
Supplying, laying, jointing and testing underground cable PVC XLPE insulated armoured and PVC sheathed LT 1100 volts grade (heavy duty) with aluminium conductor 3.5 core, 120 Sqmm, confirming to IS-1554, laid in ducts/through pipes, in floor, on poles, in trenches complete all as specified. Note :- Clamps, GI pipes, excavation, earth work, sand cushioning and brick protection cover shall be measured and paid for separately.
Supplying, laying, jointing and testing underground cable PVC XLPE insulated armoured and PVC sheathed LT 1100 volts grade (heavy duty) with aluminium conductor 3.5 core, 240 Sqmm, confirming to IS-1554, laid in ducts/through pipes, in floor, on poles, in trenches complete all as specified. Note :- Clamps, GI pipes, excavation, earth work, sand cushioning and brick protection cover shall be measured and paid for separately.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth, for foundation etc. or for shafts, welles cesspitsm, manholes, pier holes, etc. n exc 10 sqm on plan and n exc 1.5m in depthe in hard/dense soil and getting out , complete all as specified and as directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25m, complete all as specified.
Removing excavated material to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the strating point, complete all as specified and directed by Engr-in-Chrage
Sand cushioning to underground cables 8 cm below the cable before laying & 15 cm above the cable after laying, complete all as specified in clause 19.75 of SSR Par-I, complete all as specified and directed by Engr-in-Charge
Replacement of factory made, machine pressed, unreinforced, pre-cast concrete cable cover class LV type-I flate size 250 x 150x40mm , complete all as specified and directed by Engr-in-Charge.
Supplying & fixing in replacement mild steel galvanized pipe light grade 80 mm nominal bore for passing of cable fixed to poles/walls/laid under floor/roads complete with and including, fittings as required all as specified and directed by Engr-in-Charge
Supplying & fixing in replacement mild steel galvanized pipe light grade 50 mm nominal bore for passing of cable fixed to poles/walls/laid under floor/roads complete with and including, fittings as required all as specified and directed by Engr-in-Charge
Supplying & fixing in replacement mild steel galvanized pipe light grade 40 mm nominal bore for passing of cable fixed to poles/walls/laid under floor/roads complete with and including, fittings as required all as specified and directed by Engr-in-Charge
Material and Labour for painting of LT Panels including cleaning of exposed surface with brush and empry paper including painting with smoke grey paint all as directed any size of LT Panels complete all as specified and directed by Engr in Charge.
M&L for Synthetic Insulating Mat for Electrical Instrument of size 2mx1mx10mm complete all as specified and directed by Engr in Charge.
Supply and fix Indicator lamp LED type(Red,Yellow, green) moulded single piece suitable for LT Panels after taking out the Old U/S indicator lamp.
Dismantling insulators any type and any size complete all as specified and directed.
Supply & fix Pin type, porcelain,vitreous, white, green & brown insulator including one galvanised iron steel spindle, two galvanized iron washer and one galvanised iron nut, working pressure 1100 Volts and of size 65 mm dia and 100 mm height. ISI marked
Supply & fix shackle type, porcelain,vitreous, white, green & brown insulator including one galvanised iron steel spindle, two galvanized iron washer and one galvanised iron nut, working pressure 1100 Volts and of size 115 mm dia and 100 mm height. ISI marked
Supply and fix PVC Spacers 2/4 way for LT OH Line 1100 Volts grade with necessary screws nuts bolts etc complete all as specified and directed prevent the lines touching each other on heavy wind as a preventive arrangement to the existing system including removing the existing old/out lived spacers.
Prepration of old Steel Surfaces and applying two coat of synthetic enamel white paint to LT Steel tubular /PCC Pole and upto 1 Mtr height from ground level alternative in Yellow and black or white and black strips of 30 CM height each including numbering of Pole No with black paint complete all as specified and directed by Engr in charge.
Dismantling / Taking down of Old broken LT Danger notice Plate of any size complete all as specified and directed.
Supply and fixing Danger notice Plate of 1.6 mm thick mild steel sheet , vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS Clamps , bolts and nuts of approved size, for LT ,20x15 CM size.
Material & labour for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6.3mm thick buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised Iron strip of 32 x 6 mm as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil , returning , filling in approved soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR 1991(Part-I) complete all as specified and directed.
Supply and fix GI earthing strip of size 25x4 mm on PVC/Porcelain insulators at suitable distance with saddeles and fixing screws for roof/wall conductors and down conductors above ground all joints of GI strip should be brazed properly.
Supply and fixing cable route indicator made out cast iron and embedded LT Cable on the plate of size 80 mm dia 5 mm thick and gouting lugg of suitable size including gouted in PCC foundation of suitable size complete all as directed.
Taking down Old U/S MCCB of any type and any capacity compplete all as specified and directed by Engr in Charge.
Replacement of MCCB 800 Amps current carrying capacity 50 KA, 3 pole AC, 415 Volts three pole with microprocessor based setting complete all as specified and directed by Engr in Charge. Make: L&T /Havells/Indo Asian/Legrand/HCL.
Replacement of MCCB 630 Amps current carrying capacity 50 KA, 3 pole AC, 415 Volts three pole with thermal & adjustable magnetic setting complete all as specified and directed by Engr in Charge. Make: L&T /Havells/Indo Asian/Legrand/HCL.
Replacement of MCCB 800 Amps current carrying capacity 50 KA, 4 pole AC, 415 Volts three pole with microprocessor based setting complete all as specified and directed by Engr in Charge. Make: L&T /Havells/Indo Asian/Legrand/HCL.
Replacement of MCCB 630 Amps current carrying capacity 50 KA, 4 pole AC, 415 Volts three pole with thermal & adjustable magnetic setting complete all as specified and directed by Engr in Charge. Make: L&T /Havells/Indo Asian/Legrand/HCL.
Replacement of MCCB 500 Amps current carrying capacity 36 KA, 4 pole AC, 415 Volts three pole with thermal & adjustable magnetic setting complete all as specified and directed by Engr in Charge. Make: L&T /Havells/Indo Asian/Legrand/HCL.
Replacement of MCCB 400 Amps current carrying capacity 36 KA, 4 pole AC, 415 Volts three pole with thermal & adjustable magnetic setting complete all as specified and directed by Engr in Charge. Make: L&T /Havells/Indo Asian/Legrand/HCL.
Replacement of MCCB 200 Amps current carrying capacity 36 KA, 4 pole AC, 415 Volts three pole with thermal & adjustable magnetic setting complete all as specified and directed by Engr in Charge. Make: L&T /Havells/Indo Asian/Legrand/HCL.
Replacement of MCCB 160 Amps current carrying capacity 36 KA, 4 pole AC, 415 Volts three pole with thermal & adjustable magnetic setting complete all as specified and directed by Engr in Charge. Make: L&T /Havells/Indo Asian/Legrand/HCL.
Supply and fix inreplecement MCCB 100 Amp 4 Pole of rupturing capacity 16 KA complete all as specified and directed by Engr in Charge. Make: L&T /Havells/Indo Asian/Legrand/HCL.
Supply and fix inreplacement MCCB 125 Amp 4 Pole of rupturing capacity 16 KA complete all as specified and directed by Engr in Charge. Make: L&T /Havells/Indo Asian/Legrand/HCL.
Supply and fix in replacement MCCB 350 Amp 4 Pole of rupturing capacity 36 KA complete all as specified and directed by Engr in Charge. Make: L&T /Havells/Indo Asian/Legrand/HCL.
Supply and fix in replacement MCCB 63 Amp 4 Pole of rupturing capacity 25 KA complete all as specified and directed by Engr in Charge. Make: L&T /Havells/Indo Asian/Legrand/HCL.
Taking down Old U/S Change over switch of any size or any capacity complete all as specified and directed by Engr in Charge.
Supply and replacement of ON Load Change over( Side Handle) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 63 Amps with connecting acessories complete all as specified and directed by Engr in Charge. Make-Havells/L&T /Indo Asian.
Supply and replacement of ON Load Change over ( Side Handle) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 100 Amps with connecting acessories complete all as specified and directed by Engr in Charge. Make-Havells/L&T /Indo Asian.
Supply and replacement of OFF Load Change Change over ( Side Handel) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 200 Amps with connecting acessories complete all as specified and directed by Engr in Charge. Make-Havells/L&T /Indo Asian.
Supply and replacement of ON Load Change Change over(Front Handel) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 400 Amps with connecting acessories complete all as specified and directed by Engr in Charge. Make-Havells/L&T /Indo Asian.
Supply and replacement of ON Load Change over ( Front Handle) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 630 Amps with connecting acessories complete all as specified and directed by Engr in Charge. Make-Havells/L&T /Indo Asian.
Supply and replacement of OFF Load Change over ( Side Handle) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 630 Amps with connecting acessories complete all as specified and directed by Engr in Charge. Make-Havells/L&T /Indo Asian.
Supply and replacement of OFF Load Change over ( Side Handle) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 800 Amps with connecting acessories complete all as specified and directed by Engr in Charge. Make-Havells/L&T /Indo Asian.
Supply and replacement of OFF Load Change over ( Side Handle) switch 415 Volt in sheet metal inclosure 4 Pole of capacity 1000 Amps with connecting acessories complete all as specified and directed by Engr in Charge. Make-Havells/L&T /Indo Asian.
S&F in repalcement Alluminium Thimbale of size 35/50/70/95 Sq mm complete all as specified and directed by Engr in Charge.
S&F in repalcement Alluminium Thimbale of size 120/150/185/240/400 Sq mm complete all as specified and directed by Engr in Charge.
M/S SUMEET TRADING CORP
HORIZON CONSTRUCTION COMPANY
HILL AND CO.
HIMALAYAN RENEWABLE ENERGY AND CONSTRUCTION FIRM
AMAAN ENGINEERS
ss enterprises
Hitech Erectors Pvt. Ltd.
HONY CAPT RIGZIN SAMPHEL
osho traders
stage.html
html • 0.07 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .