| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.7 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹27.0 L+₹2.5 L (10.4%)Rejected-AOC | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹30.4 L+₹6.0 L (24.4%)Rejected-AOC | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹30.8 L+₹6.3 L (26.0%)Rejected-AOC 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L4 | Rejected-AOC NOT LOWEST | |
| 5 | L5₹31.7 L+₹7.3 L (29.7%)Rejected-AOC | L5 | Rejected-AOC NOT LOWEST |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
15 Feb 2020, 6:00 pmClosed
GE (NW) MANKHURD
GE (NW) MANKHURD MUMBAI 400088
REPAIR MAINTENANCE OF SECURITY LIGHTS GARDEN LIGHTS SOLAR LIGHTS AT DOMESTIC AREA AT MANKHURD AND REPAIR MAINTENANCE OF FLAME PROOF LIGHT FIXTURE LIGHTENING PROTECTION LIGHTNING CONDUCTOR AND EARTHING OF BUILDING AT MANKHURD UNDER GE (NW) MANKHURD
2020_MES_318913_1
8967/E8
Open Tender
Civil Works
Item Rate
330 days
GE (NW) MANKHURD
AS PER NIT AND TENDER PAGES
9 documents required · 9 mandatory
₹500
GE (NW) MANKHURD
₹60,000
Yes
3 Mar 2020
27 Jan 2020
18 Feb 2020
27 Jan 2020
15 Feb 2020
10 Feb 2020
27 Jan 2020 - 9 Feb 2020
Amount
Notes : (i)The contractor should be in possession of valid electrical license to execute electrical works. (ii) Supervisor for execution of electrical works/ electrical component of works employed by the contractor shall possesses supervisor certificate of competency issued by concerned State Government/ Union Territory and the worker/ tradesmen for execution of electrical works/ electrical component of works shall hold necessary permit issued by concerned State Government/ Union Territory. Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc and not exc 10 sqm on plan and n.exc 1.5 m depth and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed.
All as per item No 1 above but exc 1.5 m in depth but n.exc 3.0 mtr depth
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and directed.
Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
M & L for sand cushioning by spreading in trenches fine dry river sand gently by punning down manually as in cable protection complete all as specified and directed. Note : Punning down thickness will be measured & paid
Supply and laying un-reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid in trenches complete all as specified and directed.
Laying only un-reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm complete all as specified and directed. Note :- Serviceable cable cover obtained from Ser Item No 12, 13, 53 & 54 here-in-after shall be reused.
M & L for PCC 1:4:8, type D-2, (using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M & L for PCC 1:3:6, type C-2, (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
Dismantling of PCC foundation / pole coping from ground level all as per specified.
M & L for PCC 1:2:4, type B-1, (using 20mm graded stone aggregate) as in coping including necessary use & waste of form work complete all as specified and directed.
Supply and Laying or fixing or passing through pipe, XLPE insulated ISI marked, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 16 Sqmm 3 core including necessary connection and providing cable lugs as required including disconnection/taking down of existing cable all as specified.
All as per item No 12 above here-in-before but 10 Sqmm 3 Core.
Dismantling of old UNSV/rusted steel tubular poles 9 mtr long necessary disconnecting cables/over head condcutor and removing unserviceable pole from site complete all as specified and directed.
Supply and erection of steel tubular swaged pole 9.00 metres long designation 410-SP-31 complete with cast iron base plate, finial taper plug, bolts, nuts and screws etc including and numbering of poles with synthetic enamel white paint on black synthetic enamel paint base and stripping with yellow and black synthetic enamel paint (100 mm each stripe) 3 Nos at equal distance from bottom (above PCC coping) upto a height of 1200 mm complete all as specified and directed. Note :- Earth work and concrete foundation shall be measured and paid seperately under relevant items of Sch 'A'
M&L preparing surfaces of steel tubular swaged pole LT with scraping out old paint by emmery paper, caustic soda complete and painting with two coats of aluminium paint and numbering of poles with white paint on black paint background and stripping with black and yellow synthetic enamel paint (100 mm each stripe) 3 Nos at equal distance from bottom (above PCC coping) upto a height of 1200 mm complete all as specified and directed.
M&L for preparation of old painted surfaces of pre-stressed concrete pole upto 11/9 mtr long by scarping old paint and applying two coats of cement base paint including numbering of pole with black synthetic enamel paint painting the base of the pole in alternate black and yellow stripes each 30 Cm apart up to 1.5mtr height complete all as specified and directed.
Supply and fix in replacement of FRP looping box of size 300x250x120 mm with three terminal, connector, MCB 6 Amps, Din Rail, including GI clamps made out of GI flat of size 25mm X 3 mm channel and necessary nut, bolts and washer including making connections complete all as specified and directed. Make - National / Sintex /Universal
M&L for cutting existing road/hard standing not exc 30x60 cm in wide & depth getting out excavated material for laying GI tube including returning filling & well ramming watering finish suraface and provision of 10 cm concrete using PCC 1:3:6 type C2 from Top', including removal of surplus soil omplete all as specified and directed.
S& F in replacement of GI steel tubing medium grade 40 mm dia for laying in ground, along the pole in coping, road crossing etc for cable protection including necessary fittings , clamps for supports, etc all as directed by Engineer in charge.
M&L for taking down old unsv and supply & lay 3 Core 1.5 Sq mm size multistranded FRLS copper conductor PVC unsheathed 650 / 1100 Volt Grade As per IS 694 with and including 20 mm dia PVC conduit and passing through PVC conduit with necessary saddle, clamps, bolts & nuts, all for interconnection of cable looping box to Street Light Fitting, Post Top Lantern etc complete all as specified and directed.
Dismantling and taking down the existing defective street light fitting/Garden lights/Building security light of any type and any capacity from steel tubular pole, opening the street light fitting, checking the serviceability of spare parts including replacement of defective parts if found defects such as electric drivers for LED 30 to 70 watt after repairing including refixing on pole including connecting & testing complete all as specified and directed. Note:- Electronic drivers will be measured and paid separately on respective item of Sch 'A' here-in-after
Supply and fix flood light fittings LED type 150 Watts with and including drivers, pressure die cast aluminium housing, prewired complete all as specified and directed. The fitting shalll conform to cat No . ENDURAPULSENSL150WLED757PASYBOTG of Havells or Equivalent from Philips/Bajaj/Crompton
Supply and fix street light fittings LED type 60 Watts complete with and including drivers, pressure die cast aluminium housing, prewired complete all as specified and directed. The fitting shalll conform to cat No -ENDURAPEARLPLUSSL60WLED757SASYTOPC of Havells / Philips/Bajaj
Supply & Fix 8 watts LED Bollard Garden light fittings with efficient high output LED, Pressure die cast powder coated housing with PC diffuser , driver nuts, bolt, washers, base plate, foundation 0.3 Meter x 0.3 Meter x 0.3 Meter by PCC 1:2:4 type B-1 using 20 mm graded stone aggregates of size including excavation and earthwork, provision of GI bend of size 50 mm dia in the PCC for cable entry complete all as specified and directed., the Fitting Shall Conform to Cat No - CONEBL8WLED857SSYMTOPC of Havells / Bajaj/Crompton
S & F decorative 35 Watts LED Post Top Lantern, 230 Volts, including drivers, pressure di cast aluminium housing, prewired complete all as specified and directed. The fitting shalll conform to cat No - CORALPT35WLED757PSYMTOPC of Havells /Bajaj/Crompton
S & F decorative 20 Watts LED Post Top Lantern, 230 Volts, including drivers, pressure di cast aluminium housing, prewired complete all as specified and directed. The fitting shalll conform to cat No - RUBYT25WLED757PSYMTOPC of Havells /Crompton/Bajaj
Supply only LED Driver 60 to 70 Watts Suitable for street light fitting complete all as specified and directed.. Make: Crompton /Havells/Bajaj
Supply only LED Driver 30 to 40 Watts Suitable for street light fitting complete all as specified and directed., driver Shall Conform to Cat no S0DQL1-54-700-40Wof Crompton or Equivalent from Havells /Bajaj
M&L for straight through joint (HEAT SHRINKABLE TYPE KITS) for underground cable including joint kits and labour complete for making joints suitable for LT, XLPE/PILCA/PVC sheathed armoured heavy duty cable with aluminium conductor 3.5/4 core 25 to 50 Sqmm complete with testing till satisfaction of Engr-in-Charge.
S & F in repair analog time switch FM/1 Quartz, supply voltage 240 Volts 50 Hz, Type- QT(DAILY) complete all as specified and directed. Make Havells/ C&S/ Siemens/ L&T
S & F in repair pole power contactor MNX-18 of coil voltage 415 Volts complete all as specified and directed Make Havells/ C&S/ Siemens/ L&T
S & F in repair spare coil for MNX-18 3 pole power contactor of 415 volts complete all as specified and directed Make Havells/ C&S/ Siemens/ L&T
M&L for earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the earth plate not less than 1.5M below normal GL, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 15 mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I, 2009 specification including taking down existing earthing complete all as specified and directed
M & L for depute service representative to attend the LED Solar Light fittings of 18 wattage once in a month . Service Representative will Carry scheduled preventative maintenance checks as per details given below at Mankhurd for 26 fittings per month (a) Solar PV Modules - Check the Circuit Voltage and current characteristics. Also, check the mechanical integrity of the Solar PV Modules. (b) Battery Bank - Check the Specific Gravity of the Electrolyte, Electrolyte level, battery terminals, Battery Bank box and adding Electrolyte solution if required. Note:- Electrolyte solution will be measured seprately under this Schedule. (c) Solar PCU - Check DC input Voltage and Current, Check AC input Voltage and Current, checking the wiring. (d) Module Mounting Structures -Check the mechanical integrity of the Solar PV Modules Mounting Structures. Ensure that there is no corrosion set up on the MMS and the module is firmly fixed. (e) System Wiring - Check the system wiring including the insulations, cable lugs and rewiring/soldering if any required (f) Module Cleanliness - Cleaning of the dust accumulated over the Solar Module, and taking corrective measures
M&L for preparation of old painted surfaces of Solar Street Light Poles including acessories by scarping old paint and applying two coats of aluminium paint including numbering of pole with black synthetic enamel paint all as directed by Engineer in Charge
Supply and fix in replacement of LED 18 watt DC solar light fitting Make - Emvee / ICPC Solar
Supply and fix inreplacement of low maintenance VRLA lead acidic battery of 120 AH suitable for 1 x 18 watt Solar Light fitting all as per recommanded by Manufracturer complete all as specified and directed
Supply and fix inreplacement of charge controller suitable for 18 watt Solar Light fittings incluing any wiring as required complete all as specified and directed
Supply only electrolyte solution to be incorporated in servicing, suitable for Solar charged battery of any capacity complete all as specified and directed
M&L for earthing complete with Copper earth plate electrode 600x 600x 3 mm buried directly in ground with top edge of the plate not less than 1.5 mtrs below normal ground level and connected to earth test point by means of copper Strip of size 20x3 mm all as specified and shown in electric plate No 3 of MES SSR Part-I 2009 including earthwork, PCC chamber, CI cover, protection and watering pipe, funnel, mesh etc all as required at site and including taking down of old earthing complete all as specified and directed
M & L for Taking down of aluminium/copper strip of any size laid as roof conductor, down conductor, earth contunity conductoor including air termination rod from any position / location of sheds/ buildings of height up to 30 meter & refixing the same after straightning the conductor/removal of bends, including replacing the old insulators with new one and saddles all as directed at site Note -i) The quoted rate is deemed to inclusive of T & P/scaffolding/staging etc for executing the work in buildings of height up to 30 meter. ii) The rate is deemed to be inclusive for providing Procealin insulator, screws, Plugs iii) PCC Block required shall be measure and paid under respective items
S&F in repairs aluminium earth strip as roof/down/earth continuity conductors of size 25x3mm with saddles, insulators, screws, etc to / at any position / location of sheds/ buildings of height up to 30 meter complete all as specified and directed by the Engineer-in-charge Note -i) The quoted rate is deemed to inclusive of T & P/scaffolding/staging etc for executing the work in buildings of height up to 30 meter. ii) The rate is deemed to be inclusive of Procealin insulator, screws, Plugs
S&F in repair air termination, single pointed aluminium rod, 12mm dia 300mm long at any position / location including all necessary termination base plate, scaffolding / staging required, etc. complete all as specified and directed by the Engineer-in-charge
M&L in repair Test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm, drilled and screwed including 3 nos. 8mm dia 25 mm long hex. Head screw in replacement of the unserviceable. Including MS box made out of 3 mm thick sheet for fixing the block complete all as specified and directed.
M&L for pre-cast cement concreate block of size 0.15M x0.15M x0.15M for fixing of Aluminium strip type C1 1:3:6 using 20mm graded stone aggregate in cement motor 1:4, including fixing the concrete block on terrace of bldgs of height up to 30 meter all as directed at site Note - The quoted rate is deemed to inclusive of T & P/scaffolding/staging etc for executing the work in buildings of height up to 30 meter.
S&F GI 32x6mm earth continuity strip fixed to walls on batten or recess or chases or buried in ground or drawn in pipe, etc. as fixed / laid in repairs complete all as specified and directed by the Engineer-in-charge
S&F copper 20x3 mm earth continuity strip fixed to walls on batten or recess or chases or buried in ground or drawn in conuit / pipe or fixed to poles or any other indicated situation for earthing, etc. as fixed / laid in repairs complete all as specified and directed by the Engineer-in-charge
S&F fix in replacement wall mounted outdoor type double door LT Panel made out of 3 mm thick CRCA Sheet, the panel shall be provided with flame proof MCB DB made out of Cast aluminium alloy LM6, inside and out side light grey epoxy powder coating shade, with 1 No cable entry for incoming cable and three Nos cable entry for out going circuits with and including cable gland and stopping plug, 1 No MCB SPN 32 Amp as incoming and 3 Nos MCB SP6 Amps for out going connections IP 65 protection as per IS 2147/1962. The panel shall be powder coated, front openable and locakable with key and shall be fabricated from CPRI approved sample manufacturer. Make of MCB DB shall of Sudhir /Flexpro /Baliga /crompton greeves Note - The contractor shall submit the Layout Drawing of Panel and got approved by GE before the panel fabrication
M&L for sub main wiring with two single core 2.5 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade drawn in through existing stove enamelled steel conduit with and including PVC insulated 2.5 Sq mm single core multi strand copper conductor as continous earth wire in green colour connected to common earth dolly, DB, Fittings in wall, ceiling, steel frames of builings, including necessary flexible steel conduit and replacing of old damaged saddles & spacers, junction boxes of conduit all as directed Note : 1. Two runs of cable, one run of earth wire will be measured and paid one unit.
M&L for sub main wiring with two single core 2.5 Sqmm PVC insulated FRLS multistranded flexible copper conductor cable 660/1100 volts grade with and including stove enamelled steel conduit laid over the surface of wall/ceiling and PVC insulated 2.5 Sq mm single core multi strand copper conductor as continous earth wire in green colour, the cable shall be drawn in through stove enamelled steel conuit and connected to DB, equipments, connector, common earth dolly all as specified in wall, ceiling, steel structures of builings with necessary flexible steel conduit and saddles & spacers and as directed Note : 1. Two runs of cable, one run of earth wire, one run of steel conduit will be measured and paid one unit.
Supply and Laying or fixing or passing through pipe, XLPE insulated, ISI marked armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 50 Sqmm 3.5 core in trenches, along the wall including necessary connection and providing cable lugs as required including disconnection/taking down of existing unserviceable all as specified.
All as per item No 53 above here-in-before but 35 Sqmm 3.5 core. Note : A sum of Rs 75,986.00 towards sch of credit shall be deducted to arrive the contract sum.
NOEL ENGINEERS
A P ENTERPRISES
sapana enterprises
M/s Bhagirathi Electricals
Shree Ayyappa Engineering
cooltech engineering services
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .