Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 LAccepted-AOC | ₹9.1 L | L1 | Accepted-AOC Because for L1 |
| 2 | L2₹9.2 LRejected-Finance | ₹9.2 L | L2 | Rejected-Finance HIGHER RATE |
| 3 | L3₹11.1 LRejected-Finance | ₹11.1 L | L3 | Rejected-Finance HIGHER RATE |
| 4 | L4₹11.1 LRejected-Finance 1ST FLOOR 775 NEAR KAMANIYA GATE LORDGANJ JABALPUR MP | JABALPUR | MADHYA PRADESH | 482001 | ₹11.1 L | L4 | Rejected-Finance HIGHER RATE |
| 5 | L5₹11.4 LRejected-Finance | ₹11.4 L | L5 | Rejected-Finance HIGHER RATE |
| Sl No | Description | Qty | Unit | SURENDRA SINGH L1 | chandra prakash sen L2 | SHRADDHA ELECTRICALS AND INFRASTRUCTURE GROUP L3 | ADITYA ENTERPRISES L4 | SUPER ELECTRICALS L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00Electrical Items : | ||||||||
| 1.01 | Back filling of poles with boulders.1 | 30 | Number | - | - | - | - | - |
| 1.02 | Bi-metallic clamps suitable for 12mm dia stud and 50sqmm AAAC | 48 | Number | - | - | - | - | - |
| 1.03 | BIMETALIC CLAMP DISTRIBUTION TRANSFORMERS BUSHING | 36 | Number | - | - | - | - | - |
| 1.04 | LT Distribution box with Isolator & HRC fuse - 63 KVA DTR (200A & 6 SP of 60A) | 12 | Number | - | - | - | - | - |
| 1.05 | Deep drawn metal service connection box-1 phase 1incoming 35sqmm 8 outgoing 10sq | 10 | Number | - | - | - | - | - |
| 1.06 | Deep drawn metal service connection box-3 phase 1incoming 35sqmm 8 outgoing 10sq | 10 | Number | - | - | - | - | - |
| 1.07 | Anti climbing devices | 131 | Number | - | - | - | - | - |
| 1.08 | STAY WIRE 7/3.15 MM.(7/10 SWG) | 66 | Kilogram | - | - | - | - | - |
| 1.09 | EARTHING SET (DTR EARTHING) AS PER CIRCULAR NO 1516 DATED 17.03.08 | 12 | Set | - | - | - | - | - |
Tender Value
₹14.2 L
EMD Value
₹15,000
Closing Date
1 Mar 2019, 2:30 pmClosed
B.S. GINNARE
STC DIVISION MPMKVVCL RAISEN
Estimate for Bifurcation of 11Kv Intkhedi Mixed feeder emanating from 33/11Kv S/s. Sultanpur under Goharganj D/c. (OnM) Dn. Obaidullaganj
2019_MKVVC_19181_1
DGM/STC/WORK/111/01
Open Tender
Electrical Works
30 days
Estimate for Bifurcation of 11Kv Intkhedi Mixed fe
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,500
RAO MPMKVVCL
₹15,000
31 Dec 2025
23 Feb 2019
2 Mar 2019
23 Feb 2019
1 Mar 2019
23 Feb 2019
Electrical Items :
Back filling of poles with boulders.1
Bi-metallic clamps suitable for 12mm dia stud and 50sqmm AAAC
BIMETALIC CLAMP DISTRIBUTION TRANSFORMERS BUSHING
LT Distribution box with Isolator & HRC fuse - 63 KVA DTR (200A & 6 SP of 60A)
Deep drawn metal service connection box-1 phase 1incoming 35sqmm 8 outgoing 10sq
Deep drawn metal service connection box-3 phase 1incoming 35sqmm 8 outgoing 10sq
Anti climbing devices
STAY WIRE 7/3.15 MM.(7/10 SWG)
EARTHING SET (DTR EARTHING) AS PER CIRCULAR NO 1516 DATED 17.03.08
Earthing for PCC Pole 4.00 mm-8 SWG G.I wire- 0.8 Kg, per pole
M.S.Nuts and Bolts
A.B Cable hanging clamps/ tension clamps (Galvanized) as per enclosed Drawing
11 KV Strain hardware (T&C type) fittings
Suspension Clamp for LT AB cable
Clamps for neutral for AB Cable
Jointing Sleeves suitable for Raccoon (80Sq.mm.Al. Eq.) AAAC conductor
Piercing connector Type-I for 1P/3P (Main 16-50 sqmm tap-off 16-50 sqmm)
Piercing connector Type-II (Main 16-50 sqmm tap-off 16-50 sqmm)
Aluminium binding wire and tape
Back Clamp for 140 Kg PCC Pole MS Flat 50x6 mm
11 KV Top clamp 65X65X6 mm. angle type
Clamp for 140 Kg PCC Pole MS Flat 50x6 mm1
D.C. Cross-arms 8' Channel (100x50x6mm)
Transformer mounting Channel (100X50x6 mm.)
Trans.Mounting with Belting with 50X50X6 mm.angle with two cross fixing channel
D.O.Mounting channel 75x40x6 mm
Stay set complete without Stay wire 16 mm. (Painted)
Bracing/Support angle of 65x65x6 mm for 8' (2.4 mtr ) centre DP
Danger Boards Enamelled 11 KV
Stay Insulators 90X65mm
11 KV Composite Polymer Disc Insulators
Red oxide paint
Aluminium paint
Back filling of poles with boulders.
Concreting of stay (20 mm / 25 mm) @ 0.3 cmt. per stay
Concreting of stay (16 mm / 12 mm) @ 0.2 Cmt. per stay
Concreting of PCC support @0.5 cmt. per pole for base padding for S/S DP/TP etc
Concreting of PCC poles @ 0.45 cmt. (Cubic Metric Ton) per pole
Earthing for PCC Pole 4.00 mm-8 SWG G.I wire- 0.8 Kg, per pole1
Stone Block/Pre cast block for base pedding(450X450X75MM)
GST Charges
L&T Charges
chandra prakash sen
SHRADDHA ELECTRICALS AND INFRASTRUCTURE GROUP
ADITYA ENTERPRISES
SUPER ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid