Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Rejected-Technical | Rejected-Technical Section-3 is not prescribed format because list of completed works not shown there. |
| 2 | Rejected-Technical | Rejected-Technical Bidders does not meet the minimum qualification criteria because its available bid capacity for construction work is less than total bid value as per clause 4.6 of ITB and profit and loss statements not attached as provided in para 4.2(f) of ITB |
| 3 | Rejected-Technical | Rejected-Technical made misleading or false representation in the forms, statements, afiidavit and attachements submitted in proofs of the qualification requirements and /or as per clause 4.7(i) of ITB |
Tender Value
₹1.0 Cr
EMD Value
₹2.1 L
Closing Date
5 Feb 2026, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE, RED, Saharanpur
O/o SE, RED, Saharanpur Circle, Vikas Bhawan, SRE.
Aaudhyanik prayog avam prashikshan Kendra Saharanpur mein shahad parikshan prayogshala ka nirmaan karya
2026_REDUP_1109741_1
802/RED/Accounts/Tender file no-76/25-26 date 08-01-26
Open Tender
Civil Works - Buildings
Percentage
180 days
Saharanpur
Aaudhyanik prayog avam prashikshan Kendra Saharanpur mein shahad parikshan prayogshala ka nirmaan karya
3 documents required · 3 mandatory
₹2,714
₹2.1 L
O/o SE, RED, Saharanpur Circle, Vikas Bhawan, SRE.
25 Mar 2026
27 Jan 2026
6 Feb 2026
27 Jan 2026
5 Feb 2026
27 Jan 2026
27 Jan 2026
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil (As per DSR- 2.6.1).
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials (As per DSR- 2.26.1).
Providing and injecting chemical for pre construction anttermite treatment andc reating and chemical barrier under and around the column pits wall trench esbasement excavation tops urface in plinth filling junction of wall and floor, along the external permeter of binding expansion joints surrounding or pipes and conduit etc. complete (plinth area of the building at ground floor only shall be measured as per I.S.6313 (parII1981 Aldrine emulsifiable concentrate or any other approved material such as heptachlor of chlordane will be used. The rate of application of chemical emulsion shall be as follows:- 1.Treatmentformassonary and foundation 5 liters per sqm. 2.Back fill in immediate contact with foundation 7.5 liters per sqm. 3.Treatment of surface of plinth filling 5 liters per sqm. 4. Treatment of soil along external pera meter of Building 7.5 liters per sqm 5. Treatment of soil under external parameter 5 liters per sqm. (As per PWD SOR-2022 - New Item- 19).
Filling available excavated earth (excluding rock) in trenches ,plinth,sides of foundation etc . in layers not exceeding 20cm in depth ,consolidating each deposited layer by ramming and watering lead upto 50m and lift upto 1.5m (As per DSR- 2.25).
Filling with available fly ash and earth (excluding rock) in trenches or embankment in layers (each layer should not exceed 15 cm), with intermediate layer of compacted earth (Soil density of 98%) after every four layers of compacted depth of fly ash, sides & top layer of filling shall be done with earth having total minimum compacted thickness 30 cm or as decided by Engineer -in-charge, including compacting each layer by rolling/ ramming and watering, all complete as per drawing and irection of Engineer -in - charge. (As per DSR- 2.25(a)).
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. (As per DSR- 2.27).
Providing and laying in position cement concrete 1:4:8 (1cement :4fine sand:08graded stone aggregated 40mm .nominal size.) excluding the cost of centering and shuttering - All work upto plinth level (As per DSR- 4.1.8).
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 sq.m cement :3 coarse sand : 6graded stone aggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth (As per DSR- 4.17).
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).All works upto plinth level (as Per DSR- 5.33.1.1).
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).All works above plinth level upto floor V level ( AS per DSR- 5.33.2.1).
Centering shuttering including strutting, propping etc. and removal of form work, FOUNDATION UP TO PLINTH (As Per DSR- 5.9.1).
Centering shuttering including strutting, propping etc. and removal of form work, Column Shuttering in Super Structure (As Per DSR- 5.9.6).
Centering shuttering including strutting, propping etc. and removal of form work, Roof Beam Shuttering (As per DSR- 5.9.5).
Centering shuttering including strutting, propping etc. and removal of form work, Slab Shuttering (As per DSR- 5.9.3).
Centering shuttering including strutting, propping etc. and removal of form work, STAIR CASE (As per DSR- 5.9.7).
Centering shuttering including strutting, propping etc. and removal of form work, Lintel Shuttering & Sunshade (As per DSR- 5.9.5).
Reinforcement for R.C.C work including straighting,cutting,bending ,placing in position and bending all complete (As per DSR- 5.22.6).Thermo mechanically treatedbar Grade F500D
Brick work with brick of class designation 75 in foundation & plinth in cement mortar 1:6 (As Per DSR- 6.1.2).1%6 Cement coarsand
Brick masonry with F.P.S bricks of class designation 75 in superstructure above plinth level up to floor five level in cement mortar 1:6 ( 1 cement : 6 coarse sand) (As Per DSR- 6.4.2).
Half brick masonry with F.P.S bricks of class designation 75 in superstructure above plinth level up to floor five level in cement mortar 1:4 ( 1 cement : 4 coarse sand) (As Per DSR- 6.13.2).
Extra for providing and placing in position 2 Nos. 6mm dia. M.S.bars at every third course of half brick masonry (with F.P.S.bricks). (As Per DSR- 6.15).
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (As per DSR- 9.21.1).
Providing/fixing M.S. grills of required pattern in frames of windows etc. with M.S. flat, square or round bars etc. all complete, Fixed to steel windows by welding. (As per DSR- 9.48.1).
Providing & fixing of wire mesh (mosquito jalli) with labour & material comlete, With 12 mm mild steel U beading. (As per DSR- 9.51.2).
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. (As per DSR- 9.83).
Providing and fixing chromium plated brass handles with necessary screws etc. complete: 75 mm (As Per DSR- 9.92.3).
Providing and fixing aluminium sliding door bolts, ISI marked anodised(anodic coating not less than grade AC 10 as per IS : 1868),transparent or dyed to required colour or shade, with nuts and screws etc. complete (250x16 mm), (As per DSR- 9.96.2).
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete (100x10 mm), (As Per DSR- 9.97.5).
Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. Single rubber stopper (As Per DSr- 9.101.1).
Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms. (As per DSR- 9.109).
Providing and fixing M.S. Tubular frames for windows, ventilators with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. (As per DSR- 10.15.1)
Providing and fixing M.S. Tubular frames for doors and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. (As per DSR- 10.15.1)
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube (As per DSR- 10.26.1).
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 4.0 mm thick glass panes (As per DSr- 10.30.1).
Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. (As per DSR- 10.3).
P/F 1st quality ceramic glazed wall tiles conforming to IS : 15622 of approved make in colours , shades except burgandy , bottel green , black of any sizes as approved by Engineer -in -Charge in skirting , risers of steps and dados over 12 mm thick bed of cement mortar 1:3 and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete. (As per DSR- 8.31).
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 11.26.1 25 mm thick (As per DSR- 11.26.1).
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete, (As per DSR- 11.27).
P/L Ceramic glazed floor tiles 300 x 300 mm of 1st quality conforming to I.S : 15622 of approved make in colours such as White , Ivory , Grey Fume, Red Brown laid on 20 mm thick cement mortar 1:4 including pointing the joints with white cement and matching pigment etc . complete. (As per DSR- 11.37).
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm (As per DSR- 11.41.2).
12mm thick plaster on the plain in side of mix 1:6 ( 1 cement : 6 fine sand) mortar (As Per DSR- 13.1.2).
15mm thick plaster on the plain in side of mix 1:6 ( 1 cement : 6 fine sand) mortar (As Per DSr- 13.2.2).
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including priming coat with cement primer (As per DSR- 13.41.1).
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied@ 2.20 kg/10 sqm) (As per DSR- 13.47.1).
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade Two or more coats on new work over an under coat of suitable sq.m shade with ordinary paint of approved brand and manufacture. As per DSR- 13.62.1).
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (As Per DSR- 13.80).
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surfce comlete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick As per DSR- 14.91.1).
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (As Per DSR- 17.1.1).
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid (As Per DSR- 17.3.1).
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern (As Per DSR- 17.4.1).
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap (As Per DSR- 17.7.2).
Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required Size 600x450x200 mm As per DSR- 17.11.2).
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 MM dia PVC Pipe (As Per DSR- 12.41.2).
Waste Pipe P.V.C. Pipe 75 mm dia (As per DSR- 12.41.1).
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. :- Coupler 75 mm (As Per DSR- 12.42.1.1).
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansionCoupler 110 mm (As Per DSR- 12.42.1.2).
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansionSingle pushfit Coupler 75 mm (As Per DSR- 12.42.2.1).
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansionSingle pushfit Coupler 110 mm (As Per DSR- 12.42.1.2).
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansionSingle tee with door 75 mm (As Per DSR- 12.42.3.1).
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansionSingle tee with door 110 mm (As Per DSR- 12.42.3.2).
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansionSingle tee without door 75 mm (As Per DSR- 12.42.4.1).
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansionSingle tee without door 110 mm (As Per DSR- 12.42.3.2).
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansionBend 87.5° 75 mm (As Per DSR- 12.42.5.1).
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansionBend 87.5° 110 mm (As Per DSR- 12.42.5.2).
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansionShoe (Plain) 110 mm bend (As Per DSR- 12.42.6.2).
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete :- 75 mm (As Per DSR- 12.43.1).
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete110 mm (As Per DSR- 12.43.2).
Providing and fixing 600 x 455 mm. bevelled edge mirror of Saint Gobin or Modi float glass complete with 6 mm. thick hard board ground fix to wooden cleats with CP brass screws and washers etc. complete. (As Per DSR- 17.31).
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge Internal work - Exposed on wall :- 15mm dia nominal bore (As per DSR- 18.7.1).
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge Internal work - Exposed on wall 25mm dia nominal bore (As per DSR- 18.7.3).
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge Internal work - Exposed on wall50mm dia nominal bore (As per DSR- 18.7.6).
Providing and fixing ball valve (brass) of approved quality complete, High or low pressure with plastic floats, 25 mm nominal bore (As Per DSR- 18.18.1).
Providing and fixing gun metal non- return valve of approved quality (screwed end) : 25 mm nominal bore (As Per DSR- 18.19.1).
Providing and fixing uplasticised PVC connection pipe with brass unions : 15mm nominal bore (As per DSR- 18.21.2.1).
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (As Per DSR- 18.48).
Providing & Fixing C.P. brass bib cock parryware make, 15mm nominal bore (As per DSR- 18.15.1).
Providing & Fixing C.P. brass Long boddy bib cock of approved quality conforming to IS standard & weighing not less then 690 gms, 15mm nominal bore. (As per DSR- 18.51.1).
Providing and fixing PTMT pillar cock of approved quality and colour, 15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms (As per DSR- 18.56.2).
Providing & Fixing C.P. brass stop(conceald) of standard design & approved make conformin to IS: 8931, 15mm nominal bore. (As per DSR- 18.52.1).
Providing & fixing c.p. soap dish parryware make (As per DSR- 18.65).
Provding & Fixing C.P Towel rail parryware make (As per DSR- 17.73.1).
Provisiding & Fixing C.P Paper Holder parryware Make (As per DSR- 17.34.1).
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 75 mm nominal inner dia Pipes (As per DSR- 18.9.8).
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 80 mm nominal bore (As Per DSR- 18.17.6).
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 455x610 mm and 45 cm deep for single pipe line : for sanitary building (As Per DSR- 19.30.1.1).
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement -All work up to plinth level : 1 :1.5:3 (1 cement : 1.5 coarse sand (zone-Ill} derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural source. As DSR- 5.1.2
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc . As Per DSR- 5.9.2).
Class 230 brick work on 1:4 cement and fine of 1.25 finessness modulus mortar in foundation and plinth including supply of all materials labour tools and plinth etc. required for proper completion of the work. (As Per DSR- 6.1.1).
40mm Cement concret flooring 1:2:4 laid in one layer finished with a floating coats of neat cement. (As per DSR- 11.3.1).
15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand) (As per DSR- 13.8.2)
Supplying and stacking at site.63 mm to 45 mm size stone aggregate (As per DSR- 16.3.2).
Providing and fixing soil, waste and vent pipesCentrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989. : 100 mm dia (as per DSR- 17.35.1.2).
Providing and fixing plain bend of required degree. 100 mm Sand cast iron S&S as per IS - 1729 (As per DSR- 17.39.1.1).
Providing and fixing single equal plain junction of required degree :100x100x100 mm Sand cast iron S&S as per IS - 1729 (as Per DSR- 17.44.1.1).
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar (As per DSR- 19.15.1).
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 19.19.1 L D- 2.5Rectangular shape 600x450 mm internal dimensions (As per DSR- 19.19.1.1)
Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : Around The Building (As per DSR- 2.10.1.2).
Providing and fixing on wall face unplasticised Rigid PVC pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter (As per DSR- 12.41.2).
Cartage of material by mannual labour inculding loading ,unloading & stacking up to 50m (As per DSR- 1.1.2).
Class 230 brick work on 1:4 cement and fine of 1.25 finessness modulus mortar in foundation and plinth including supply of all materials labour tools and plinth etc. required for proper completion of the work. (As per DSR- 6.1.1).
15mm thick plaster on the rough side of mix 1:3 ( 1 cement : 4 fine sand )mortar.(As per DSR- 13.2.2).
Providing & fixing of precast R.C.C manhole covering tank (600 x 450) As per DSr- 19.19.1.1)
Providing & fixing of foot rest in tank (As per DSR- 19.17.1)
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200mm (As Per DSr- 23.3.3).
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. (As Per DSR - 23.2.1.1).
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (As Per DSR- 23.5).
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge. (As Per DSR- 23.7).
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (AS Per DSR- 19.30.1.1).
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group (B), As per DSR- 1.10.2 (2025).
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. As per DSR- 1.11 (2025).
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. As per DSR- 1.12 (2025).
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.:- 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (As per DSR- 1.14.2 (2025)).
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire (As per DSR- 1.14.3 (2025)).
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 X 6 sq. mm + 1 X 6 sq. mm earth wire (As per DSR- 1.14.4 (2025)).
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required2 X 10 sq. mm + 1 X 6 sq. mm earth wire (As per DSR- 1.14.5 (2025)).
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.:- 5/6 A switch (As Per DSR- 1.24.1 (2025)).
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required2 way 5/6 A switch (As Per DSR- 1.24.2 (2025)).
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required15/16 A switch (As Per DSR- 1.24.3 (2025)).
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required3 pin 5/6 A socket outlet (As Per DSR- 1.24.4 (2025)).
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (As Per DSR- 1.25 (2025)).
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.:- 1 or 2 Module (75 mmX75 mm) (As Per DSR- 1.27.1 (2025)).
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required 3 Module (100 mmX75 mm) (As Per DSR- 1.27.2 (2025)).
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required4 Module (125 mmX75 mm) (As Per DSR- 1.27.3 (2025)).
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required6 Module (200 mmX75 mm) (As Per DSR- 1.27.4 (2025)).
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required8 Module (125 mmX125 mm) (As Per DSR- 1.27.5 (2025)).
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required12 Module (200 mmX150 mm) (As Per DSR- 1.27.6 (2025)).
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.:- 1 or 2 Module (As Per DSR- 1.28.1 (2025)).
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required3 Module (As Per DSR- 1.28.2 (2025)).
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required4 Module (As Per DSR- 1.28.3 (2025)).
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required6 Module (As Per DSR- 1.28.4 (2025)).
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required8 Module (As Per DSR- 1.28.5 (2025)).
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required12 Module (As Per DSR- 1.28.6 (2025)).
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. (As Per DSR- 1.33 (2025)).
Supplying and flxing brass batten/angle holder including connection etc. as required. (As Per DSR- 1.34 (2025)).
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. (As Per DSR- 1.38 (2025)).
Providing and fixing plain 16/0.20mm (0.50sqmm) twin flat flexible, FRLS PVC insulated, copper cable, in PVC sleeve of suitable size on the floor/ wall, or side of the table/ door etc. as required. (As Per DSR- 1.39 (2025)).
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. (As Per DSR- 1.41 (2025)).
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. (As Per DSR- 1.45 (2025)).
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.:- Upto 450 mm sweep (As Per DSR- 1.50.1, (2025)).
Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. (As Per DSR- 1.51, (2025)).
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.:- Single pole (As Per DSR- 2.10.1, (2025)).
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.:- 40 amps (As Per DSR- 2.13.1, (2025)).
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required63amp (As Per DSR- 2.13.2, (2025)).
Supplying and fixing following way prewired TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator), 4 way (4 + 12), Double door. (As Per DSR- 2.5.1, (2025)).
Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. (As Per DSR- 2.19, (2025)).
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. (As Per DSR- 2.21, (2025)).
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required (As Per DSR- 9.2.3, (2025)).
Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C):- 22 watt (As Per DSR- 8.2.5, (2025)).
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.:- 25 sq. mm 3-1/2 core (As Per PWD SOR- 2024,- 20A.1.10).
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.:- 10 sq. mm 4 core (As Per PWD SOR- 2024,- 20A.1.8).
Earthing with G.I. earth pipe 4.5 metre long, 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. As per DSR- 5.2 (2025).
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe FRLSom earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. As per DSR- 5.11 (2025).
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.:- 16 sq. mm 4 core (As Per PWD SOR- 2024,- 20A.1.9).
stage.html
html • 0.02 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.06 MB
BOQ_2049462.xls
BOQ • 0.39 MB
2.pdf
Tender Documents • 1.10 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .