Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC B 407 ANANT IMAGINE APARTMENT OLD BUS STAND KORBA DIST KORBA CG 495677 | KORBA | CHHATTISGARH | 495677 | ₹1.5 Cr | L1 | Accepted-AOC Accepted being L1 |
| 2 | L2₹1.8 Cr+₹29.8 L (20.3%)Rejected-Finance | ₹1.8 Cr+₹29.8 L (20.3%) | L2 | Rejected-Finance Rejected being L2 |
| 3 | Rejected-Technical ETTA BHATTA MAINROAD SURAJPUR BHATGAON SURAJPUR CHHATTISGARH | DURG | CHHATTISGARH | 490001 | - | - | Rejected-Technical complete Legal status doument not submitted |
| Sl No | Description | Qty | Unit | AEKANSH GROUP L1 | SRISHTI CONSTRUCTIONS L2 |
|---|---|---|---|---|---|
| 1.00Note- Work in all 3 colonies to be started simultaneously . | |||||
| 1.01 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc with dismantling as required. Group A | 4,798 | point | 500 ₹23,99,000 Lowest | 581.55 ₹27,90,276.9 |
| 1.02 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc with dismantling as required. Group B | 2,644 | point | 700 ₹18,50,800 | 673.9 ₹17,81,791.6 Lowest |
| 1.03 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc with dismantling as required. Group C | 89 | point | 800 ₹71,200 Lowest | 839.84 ₹74,745.76 |
| 1.04 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2X2.5 sq. Mm.+1X2.5 sq mm earth wire | 5,092 | meter | 120 ₹6,11,040 Lowest | 156.54 ₹7,97,101.68 |
| 1.05 | Wiring for circuit/submain wiring alongwith earthwire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed medium class PVC conduit as required 2X1.5 sq. Mm.+1X1.5 sq mm earth wire | 9,811 | meter | 80 ₹7,84,880 Lowest | 133.06 ₹13,05,451.66 |
| 1.06 | Wiring for light/power plug with 2X4 sq.mm FRLS PVC insulatedcopper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required | 9,008 | meter | 200 ₹18,01,600 | 188.63 ₹16,99,179.04 Lowest |
| 1.07 | Supply and fixing following way,single pole and neutral,sheet steel,MCBdistribution board,240 volt,on surface/recess,complete with tinned copper bus bar,neutral bus bar,earth bar din bar,interconnections,powder painted including earthing etc.as required ( but without MCB/RCCB/Isolator) 8 way double door | 439 | Each | 700 ₹3,07,300 Lowest | 1,435.47 ₹6,30,171.33 |
| 1.08 | Supply and fixing following way,single pole and neutral,sheet steel,MCBdistribution board,240 volt,on surface/recess,complete with tinned copper bus bar,neutral bus bar,earth bar din bar,interconnections,powder painted including earthing etc.as required ( but without MCB/RCCB/Isolator) 12 way double door | 138 | Each | 800 ₹1,10,400 Lowest | 1,292.24 ₹1,78,329.12 |
| 1.09 | Supply and fixing following way,single pole and neutral,sheet steel,MCBdistribution board,240 volt,on surface/recess,complete with tinned copper bus bar,neutral bus bar,earth bar din bar,interconnections,powder painted including earthing etc.as required ( but without MCB/RCCB/Isolator) 16 way,single door | 43 | Each | 1,200 ₹51,600 Lowest | 1,963.79 ₹84,442.97 |
Tender Value
₹2.3 Cr
EMD Value
₹2.8 L
Closing Date
15 Apr 2025, 5:00 pmClosed
SO EnM, SECL Raigarh Area
Office of the General Manager SECL Raigarh Area, ChhoteAtarmuda Raigarh 496001
Electrical rewiring repairing of quarters of Nawapara,Domnara and Dharam Colonies of Chhal Sub Area , SECL ,Raigarh Area .
2025_SECL_332916_1
SECL/GM/RGH/EnM/e-Tender/24-25 /36 dtd 28.03.2025
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Raigarh Area
Please refer Tender documents.
6 documents required · 6 mandatory
₹2.8 L
11 Aug 2025
29 Mar 2025
17 Apr 2025
29 Mar 2025
15 Apr 2025
31 Mar 2025
29 Mar 2025 - 8 Apr 2025
Amount
Note- Work in all 3 colonies to be started simultaneously .
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc with dismantling as required. Group A
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc with dismantling as required. Group B
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc with dismantling as required. Group C
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2X2.5 sq. Mm.+1X2.5 sq mm earth wire
Wiring for circuit/submain wiring alongwith earthwire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed medium class PVC conduit as required 2X1.5 sq. Mm.+1X1.5 sq mm earth wire
Wiring for light/power plug with 2X4 sq.mm FRLS PVC insulatedcopper conductor single core cable in surface/recessed medium class PVC conduit alongwith 1 No 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required
Supply and fixing following way,single pole and neutral,sheet steel,MCBdistribution board,240 volt,on surface/recess,complete with tinned copper bus bar,neutral bus bar,earth bar din bar,interconnections,powder painted including earthing etc.as required ( but without MCB/RCCB/Isolator) 8 way double door
Supply and fixing following way,single pole and neutral,sheet steel,MCBdistribution board,240 volt,on surface/recess,complete with tinned copper bus bar,neutral bus bar,earth bar din bar,interconnections,powder painted including earthing etc.as required ( but without MCB/RCCB/Isolator) 12 way double door
Supply and fixing following way,single pole and neutral,sheet steel,MCBdistribution board,240 volt,on surface/recess,complete with tinned copper bus bar,neutral bus bar,earth bar din bar,interconnections,powder painted including earthing etc.as required ( but without MCB/RCCB/Isolator) 16 way,single door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral
Supplying and fixing of following rating double pole,240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc as required 40 amps
Supplying and fixing of following rating double pole,240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc as required 63 amps
Supplying and fixing of following rating double pole(single phase and nuetral),240 volts ,residuat breaker(RCCB) having sensitivity current 30mA in the existing MCB DB mplete with connections, testing and commissioning etc as required 40Amps
Supplying and fixing of following rating double pole(single phase and nuetral),240 volts ,residuat breaker(RCCB) having sensitivity current 30mA in the existing MCB DB mplete with connections, testing and commissioning etc as required 63Amps
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel,making connections etc as required 100 Amp TP&N
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel,making connections etc as required 200 Amp TP&N
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 3 Module (100mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 6 Module (200mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 8 Module (125mmX125mm)
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. ( 250 Nos. for Nawapara Colony + 200 Nos. for Dharam Colony + 150 Nos. for Domnara Colony)
Total impact of GST for the purpose of CTC
SRISHTI CONSTRUCTIONS (BID ID -1148973)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .