| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.8 LAccepted-AOC DL 221 3 SALT LAKE SECTOR II KOLKATA 700091 WEST BENGAL | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | L1 | Accepted-AOC AOC Issued | |
| 2 | L2₹30.6 L+₹7.9 L (34.5%)Rejected-Finance | L2 | Rejected-Finance that the bid is not L1 | |
| 3 | L3₹32.1 L+₹9.4 L (41.1%)Rejected-Finance | L3 | Rejected-Finance that the bid is not L1 | |
| 4 | Rejected-Technical | - | Rejected-Technical due to non-availability of credential |
Tender Value
Refer Docs
EMD Value
₹62,000
Closing Date
6 Sept 2019, 11:30 amClosed
EE II NKHED PW Dte
KIT Building Annex, 4th Floor,P-16, India Exch. Place Extn., Kolkata -700073
Construction of Proposed Heritage Look Single Arch Decorative Compound Gate on Eden Hospital Road Gate 5 at Medical Collage Hospital Kolkata
2019_PWDE_238417_1
WBPWD/EE/NKHED/NIQ-48/19-20
Open Tender
ELECTRICAL WORKS ORG
Item Rate
75 days
Kolkata
Please refer Tender documents.
5 documents required · 5 mandatory
₹62,000
17 Mar 2020
14 Aug 2019
9 Sept 2019
16 Aug 2019
6 Sept 2019
16 Aug 2019
Amount
Supplying & fixing 68W, 20 Degree, 3000K Colour Temp., LED Luninaries for highlighting the Columns on both side with necessary MS Structure & Cage (as per direction of EIC) as required all complete. (Mk. Philips, Viaflood MP, Input Voltage 100 - 270V, UL/CE or similar of OSRAM / Bajaj / Crompton)
Supplying & fixing 20W, 2700K Colour Temp., 90 *x90* beam, 4 ft.Wt 4.2 kg approx), Temp -40*C to 50*C, CRI 80, long LED linear arrey Luninaries for highlighting the canopy with necessary MS Structure as required all complete. (for both side of canopy). (Mk. Philips, EW Graze EC Powercore, IP 66, Input Voltage 100 - 270V, UL/CE or similar of OSRAM / Bajaj / Crompton) (Rate is inclusive of all sorts of Scaffholding Arrangement.)
Supplying & fixing BVP 161 LED 60 NW ,70w IP 65, 220-240V Flood Light to highlight Semicircular Arch & Road Below Arch or similar of Crompton /Bajaj
Supplying & fixing 15W LED Spot Light for highlighting the Pedastal Area with necessary MS Structure & Cage (as per direction of EIC) as required all complete. (Mk. Philips, BGP 310, Input Voltage 100 - 270V, UL/CE or similar of OSRAM / Bajaj / Crompton)
Supply of following size PVC/Al. Ar. Cable (Havell's / Polycab / Finolex) 4 core x 25 sq.mm.
a. Laying of 4 C x 25 Sqmm PVC/Al. Ar. Cable through underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
b. Laying only Cable of 4 C x 25 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench.
c. Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting
S & F compression type cable gland incl. finishing the ends of the PVC/Al cables as per g.s.for the following cables. 4 core x 25 sq.mm.
a. Supply & Laying of Jumper Cable for LED Luminare (Mk. Philips, 1 ft., CE or similar of OSRAM / Bajaj / Crompton) incl. connection.
b. Supply & Laying of Jumper Cable for LED Luminare (Mk. Philips, 5 ft., CE or similar of OSRAM / Bajaj / Crompton) incl. connection.
c. Supply & Laying of Leader Cable for LED Luminare (Mk. Philips, Leader Cable, 10 ft., CE or similar of OSRAM / Bajaj / Crompton) incl. connection.
Supply & Installation of Outdoor Type Wall Mounted Distribution Box (IP 65) of size 600 x 600 x 200 mm made of 3 mm thick MS Sheet & 25 x 25 x 5mm MS equal angle frame painted with 2 coats of epoxy paint over one coat of RO primer to be fixed on wall as per direction of EIC. The FP Box Contains following items, 1. 4 way double door PBDB with 1 no. 63A TP MCB as i/c & 12 nos. 6A SP MCB as o/g. (MK. Legrand) 2. Both Side Earth Point. (Berfore Starting Construction Drawing must be approved from EIC.)
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level by ISI (M) GI Pipe.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
Extra for connecting the metal body to earth electrode incl. S&F 7/14 Stranded GI (Hot Dip) wire on wall/floor/recessed in wall with saddles.
Supply & Fixing of PVC Water Proof Loop / Junction Box (IP 66) with necessary gland & 4 pole connecting terminal (1.5 sqmm) to be fixed on / concealed in wall as per direction of EIC. (Mk. Hansel / Syntex)
Charges for cutting hard metal road (width 1000 mm & depth 150 mm) incl. restoration, cleaning & ramming the earth surface by CC as per direction of EIC.
Pipe : Supplying & fixing medium gauge 50 mm dia GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required.
Supply & Laying of 4C x 1.5 sqmm PVC insulated flexible unarmoured Cu cable (as per IS 694) (Mk. Finolex / Havell's / Polycab) through existing PVC Flexible Pipe / PVC Rigid Conduit Pipe.
Supplying and fixing 20 mm dia PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works.
Special Terms & Conditions :- i) The Agency must procure the materials from the Manufacturer / OEM or from their authorized. Sales channel so that the standard warranty / Support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. ii) Documents that authenticates such procurement form the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM /authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution of work/submission of bill. iii) If any refurbished material is supplied and installed, panel action will be taken as per existing rules. iv) Defect Libilities Period for 01(one) year from the date of completaion. iv) After completation of work Agency Supervisor has to certify fittness af all Electrical Installations done under this Tender. This is mandatory before peparations of Final Bill.
(Rate should be quotated including all taxes and duties)
ONE STOP LIGHTING SOLUTION
R. K. RAY AND CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .