| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.0 LAccepted-AOC RAJA RAMMOHAN ROY ROAD SILIGURI 734001 | SILIGURI | DARJEELING | WEST BENGAL | 734001 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹33.9 L+₹3.9 L (13.0%)Rejected-Finance 9 13 ANANDA PALLY WEST 601 ANANDA PALLY A PURBA PUTIARY SUB POST OFFICE KOLKATA 700093 | KOLKATA | KOLKATA | WEST BENGAL | 700093 | L2 | Rejected-Finance HIGHEST | |
| 3 | L3₹35.6 L+₹5.6 L (18.7%)Rejected-Finance 329 BALLY PAUL PARA GHOSH PARA NEAR BSNL TELEPHONE EXCHANGE OFFICE HOWRAH WEST BENGAL 711227 | HOWRAH | WEST BENGAL | 711227 | L3 | Rejected-Finance HIGHEST |
Tender Value
Refer Docs
EMD Value
₹51,400
Closing Date
2 Nov 2020, 2:00 pmClosed
Superintending Engineer PWD Electrical
Superintending Engineer PWD North Bengal Electrical Circle P.W.D Inspection Bungalow Annex Building 1ST Floor Kutchery Road Venus More Siliguri
Propos construction of Cottage within the campus of PWD Inspection Bungalow Madarihat in the district of Alipurduar S.I.T.C of D.G A.C machines Compound Lighting and allied E.I works
2020_WBPWD_298998_1
WBPWD/SENBEC/NIT-32/2020-2021
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
PWD Inspection Bungalow Madarihat
Please refer Tender documents.
4 documents required · 4 mandatory
₹51,400
6 Sept 2021
30 Sept 2020
4 Nov 2020
30 Sept 2020
2 Nov 2020
6 Oct 2020
Amount
Supply, loading, unloading, Installation, Testing & Commissioning of Silent type 62.5 KVA DG set confirming to CPCB -II emision norms as per the following specification.
Diesel Engine : Liquid Cooled Diesel Engine, devloping 1500rpm having blower fan of adequate capacity, fanguard, fan belts etc. the Diesel Engine shall be vertical, Electric start, compression ignition, 4 stoke, continuous run at 1500 rpm conforming to IS 10002, ISO-3046, BS 5514 standard with an permissible over load capacity of 10% for one hour in 12 hour in every 12 hrs. of operation complying present CPCB norms:
Make: Cummins / kirloskar green / Catter pillar
Alternator Alternator suitable to deliver rated output of 62.5KVA at 1500 rpm, 415V, 0.8 PF(lag), 50 HZ, 3 phase,in SPDP enclosure, self excited & self regulated, brushless. The Alternator should be IS: 4722/BS EN 60034-1 & & will be suitable for tropical condition having full load efficiency above 90%. Class of insulation shall be H, and encloser shall be IP23.
Make Stamford / Leroy Some / kirloskar.
Gen set Controller : i) Supports Auto-Mains-Failure (AMF) function and Manual-Control-Panel (MCP) function. ii) Having indication / LCD display and measures the lube oil pressure, battery voltage, engine rpm, fuel level in the day tank, engine running hrs. Indication, AC current, AC Voltage, AC frequency, AC power metering with suitable CTs for dispalying the electrical parameters. iii) Safety Alarms for High engine temperature, low lube oil pressure, low radiator water level, low fuel level, battery high voltage, under/over speed along with safety trips for High Engine temperature, low lube oil. iv) Reads all inputs & controls the DG, Controls the engine speed (speed governing),
AMF Control Panel suitable for 62.5KVA DG set consist of - microprocessor based AMF control unit, it monitors the engine safety parameters and alarm / trip condition will be displayed on front panel. Special alarm conditions include LLOP, HWT, overload, under/over speed, low fuel level. Specific indication includes various conditions of operations such as Load on mains, Load on DG, Mains healthy, DG ON, Auto & Manual mode. The control panel consist of multi function meter which displays AC current/Voltage, Frequency, Power factor, KWH etc.
Base frame, Fuel Tank having atleast 12 hrs capacity, 12 Volt battery with leads, Capacity at least 90AH , Canopy.
NOTE: 1) Rate should be cotated inclusive of all taxes, duties. 2) The DG set is to be delivered at site free of cost. 3) Necessary Warranty certificate, Testing and Commissioning report are to be submitted duly counter signed by the concern JE/AE. 4) A deceleration from engine manufacturer about no engine power direction upto 50°C ambient temp. should be uploaded during e-filling of Quotation. 5) All equipments must be warrented for a period of 18 (eighteen) month from the date of supply or 12 (Twelve) month date of commissioning which ever is earlier.
Supply and pour of H.S. Diesel oil for necessary commissioning of new DG incl. transportation cost.
Supply, Delivery including transportation of Mobil Oil.
Supply & delivery PVC 200Ltr. Oil Barrel of thickness 6mm.
S & Delivery of best quality oil hand pump with 1” dia PVC flexible pipe (12’ ft. approx).
SUB-HEAD 2-- SITC OF STREET LIGHTING SYSTEM(B)
Supply & Delivery of Hot Dip Galvanised (as per IS:2629 / IS 2633 / IS 4759 and with its latest amendment ) Octagonal Pole made of HT steel ( sheet thickness -3mm ) conforming to grade S355 of BSEN 10025 alongwith welded base plate of required size conforming to IS: 226 / 2062 with integrated Control box with required sizes studs for termination of 2 core 10 /4 Core 16 sq mm Al (Armoured ) cable incld S&F 1 No 6 Amp SP MCB ( C-Series ) for each out going circuit to the fittings with proper pad locking arrangement for the following pole -- 7 Mtr Long [ Top Dia ( A / F ) - 70 mm, Bottom Dia ( A / F ) -130 mm ] Base Plate Size : 200 mm x 200mm x 12 mm.. ( Make : Bajaj, Philips, Valmont, CG, Transrail/Bansal ).
Errection of the following Octagonal pole by designing and Casting RCC ( M 20 ) foundation of suitable size as specified below considering the safe soil bearing capacity at site as T/sq m, including excavation of earth, providing, cutting, bending and placing in position reinforcement as per drawing and providing pipe for cable entry and exit as required and providing and fixing of 4 Nos foundation bolts ( J Type ) as specified below and as per drawing on ground surface including back filling and cleaning extra earth -7 Mtr Long [ Founation size - 500 mm X 500 mm X 1200 mm, J Bolt Size - M 20 X 600 ]
SITC of single dip galvanized steel overhang bracket ( Swan Neck Type ) at the top of the pole having 1 M length complete with all fixing arrangements as required including painting (a) Single Arm
SITC of road lighting luminaire ( IP 65 ) with peanut lens and high power LED and to ensure uniform distribution, higher spacing between poles and maintenance free system andsystem lumen output will be 7000 lumen suitable for use with 230Volt 50Hz AC supply etc as required. (Make - Philips Model No. BRP 410 / Equivalent product of Crompton / Wipro having similar specification in all respect))
Supplying of one number 1.1 KV Grade XLPE insulated and PVC sheathed aluminium conductor cable (Armoured) conforming to IS: 7098 / 1988 with its latest amendment of following size. (a) 2x10sq.mm
Laying of one No. cable above in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE / PVC armoured cables as below :2 Core10 Sq. mm
Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc.and making connection to switch, BDB and BBC etc.(a) 2 Core10 Sq. mm
S & L of 1.1 KV grade 3 X 1.5 Sq mm FR single core multi stranded copper wire for connection from loop box to fittings through 13 mm dia polythene pipe.
Finishing of the PVC insulated wire(3 X 1.5sqmm) ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
S & F of medium gauge G.I pipe (ISI medium) having the following diameter [32 mm Diameter] for protection of cable with necessary fitting and jointing materials as required.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed as below (ISI medium G.I pipe)
Construction of base block foundation (6:3:1) of dimension 250x250x450 mm' partly below the ground level and partly above the G.L as muffing with 3mm thick net cement finishing as per direction of EIC
S/F theInverted Pyramid Tripod type LED Bollard with soft 360 deg light distribution incl.foundation nut & bolts with good eathing attachments as per GS.(Cat. LBLSN-10CDL)/LBLD 05R601xW (Jaquar) Equivalent product of Philips/Wipro having similar specification in all respect))
Supply and Erection of 50 mm dia 2.5 mtr. long G.I. pipe (ISI- Medium) with base platr and top portion welded with 0.3 mtr long 40 mm or as suitable size as fittings as per direction of EIC including Painting of pole with one coat of RO primer and two coat of Al. paint of approved make as to GS.
Construction of base block foundation (6:3:1) of dimension 300x300x600 mm' partly below the ground level and partly above the G.L as muffing with 3mm thick net cement finishing as per direction of EIC
Supply and fixing of post top light fittings and earthing attachment and connection complet as per direction of EIC.make CG Model no LPTH-20 CDL / Equivalent product of Philips / Wipro having similar specification in all respect) / LGTP01x012XW (Jaquar)
SUB-HEAD 3-- SITC of AC Machines
HIWALL SPLIT AIR CONDITIONING Supply & Delivery of Hi-wall Split Air Conditioner having following specification. Cooling Capacity(KCal/Hr) - 6000 KCal / Hr ISEER Rating - 3 Star / 2018-2019 as per BEE/BIS IS compliance - IS 1391
Refrigerant - R410A / R32 Compressor - Rotary / Scroll Evaporator & Condensor Coil : Copper Operating Outdoor Temparature = 50ºC and above Power Supply - 240V,50Hz (+Tolerrance as per applicable standard) [Make: Mitsubishi Electric / O- General / Toshiba / Zamil] (All inclusive of 20 / 25A Play top & changing of refrigerent)
Installation, Testing & Commissioning of Indoor & Outdoor unit of above Hi wall split AC machine after making hole in wall etc as per direction of EIC including S&F of necessary fixing arrangement for indoor and outdoor unit, duly painted, laying and making connection of refrigeration pipe, power cable, drain pipe etc as per direction of the EIC.
The scope of work is also includes supply of following (i) Necessary refrigeration copper line with nitrial rubber insulation - 3 mtr (ii) necessary copper cable (FRLSZH type - make : Finolex / Havells / Polycab / RR Kable / Gloster) - 3mtr
NOTE Special Terms & Conditions :- i) The Agency must procure the materials from the Manufacturer / OEM or from their authorized. Sales channel so that the standard warranty / Support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them
ii) Documents that authenticates such procurement form the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM /authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution of work / submission of bill. iii) If any refurbished material is supplied and installed, panel action will be taken as per existing rule
S&F of additional following items for length exceeding 3 mtr for complete installation and commissioning of aboove AC machines.
(i) Supply & Fixing of extra refrigerant pipe with insulation foam insulation (as requisite dia)
(ii) 3 core required size PVC insulated FRLSZH grade copper cable ( make : Finolex / Havells / Polycab)
Supply & Fixing of PVC drain pipe 32" dia (make approved by EIC) Precision / Suppreame
SUB-HEAD 4-- SITC of Feeder piller box
Supply& Installation of MS fabricated outdoor type Feeder Pillar box having overall dimension of 1.5mtr. x 1.2 mtr. X .9mtr.The body and upper portion of the pillar box made of 5mm thick MS sheet and bottom portion with 10mm thick MS plate rigily fixed by nuts. Bolts & washers etc. with 50mm x 50mm x 6mm MS angle and 25mm x 6mm M Sflat. The pillar box having both side doors opening with suitable handle in each door with double locking system is to be provided with Godrej Almirah type lock with 3 nos. Keys.
Additional provision for pad locking and supply of Godrej Navtal pad Lock with duplicate Key lockis also to be provided and 2nos. mechanical locks both top and bottom portion. Provision of ventilation grill should be triangular shape made with sufficient extension of out side of MS plate duly welded to lateral side. The central ventilation spout at starting surface of the top of the pillar box. Provisionfor 2nos. earthing ter 25 x 6mm G I flat having suitable nuts, bolts & washers for conncting the accessories.
Necessary Inter connection between incoming and outgoing switchs by suitable size Cu flat / wire / rod duly sleeved & insulated. Finishing the end by socketing & providing glands as required. The pillar box both inside & outside is to be painted with two coats of Al paint over one coat of red lead primer and
S& F MS channeof size 80mm x 50mm with nuts & bolts at bottom portion with two coats of Black enameled paint after finishing the surface properly. The internal E.Iworks of pillar box should be suitable to withstand 2KV for one minute. The all fabrication work should be done as per direction of E.I.C.The pillar box comprising with the following:-
INCOMING:-
(a) 415 V. 250 Amps TPN main switch with Din type HRC fuse - 1no.
(b) 315 Amps. Capacity bus bar chamber make of 14 SWG CRC of sheet with suitable M S angle iron provided with & vermin proof arrangement incorporated with 3 nos. 50 x 5 sqmm and 1no. 25 x 5 sqmm capacity high connectivity electrolytic grade copper bar duly mounted on suitablecapacity Epocxy box support copper bar with necessary number of holes and tapping with different colour insulated P V C tapes for proper identification 1 set
(C) S&F 415 V, 315 A TPN ON LOAD open execution Changeover switch. - 1 no
OUTGOING:-
A)S&F 415 V, 100 A TPN SFU open execution with 3nos DIN type HRC FUSE - 2 nos. B) S&F 415 V, 63 A TPN SFU open execution with 3nos DIN type HRC FUSE - 8 nos. C) S&F 415 V,32 A TPN SFU open execution with 3nos DIN type HRC FUSE - 2 nos. D) S & F E.I Danger Board (6" x 4).- 2 nos E) S/F Hylem sheet one side for three phase meter Installation including S/F of 3nos 500V 315A cut out
Construction of base foundation for installation of Feeder Piller Box of following sizes incl earth cutting, soalling(3"), rough concrete base work( 1:3:6) 3" thick, 10" brick work at four side of the base( 1:4), plasterring(1:6) 15mm thick and net cement punning at the upper and outer side of the base. Sand filling into the inner portion and making hole for cable entry as per direction of EIC
a) 1800mm(L)x1500mm(B)x1350mm(H)
Supplying of one number 1.1 KV Grade XLPE insulated and PVC sheathed aluminium conductor cable ( Armoured ) conforming to IS: 7098 / 1988 with its latest amendment of following size.
4 Core 95 Sq. mm Main panel TO sub LT panel ]
Laying of one No. cable 4 core 95 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below including finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials
4 Core 95 Sq. mm
SUB-HEAD 5-- SITC of LED SIGN BOARD
LED Signage: Designing, Fabrication, Supply, Installation, Testing & Commissioning of Outdoor LED Signage (Approximate Size:16' Length X 6' height) in English (letters given and approved by concerned department) for letters with following specifications
(a) The box for the signage will be fabricated in Aluminum Square tube of size 25 mm. X 25 mm. of 16 gauge complete with necessary priming and painting. The front of the box will be covered with 3 mm. thick Aluminium Composite Panel (ACP) sheets of the entire board. The board to be fixed in front of canopy by providing required support and Angle Bracing. The complete installation will be water, vermin and dust insulated and protected.
(b) Letter Description: Approx 9" x 5" size of letters made of Aclrylic Sheet with male female attachment, on router cut ACP Sheet of front incl. all accessories as required.
(c) LED Illumination:High Bright, High Wave length closed type waterproof white LED modules (0.72 W or Higher) mounted on interior side of female part of letter with power wire running back to a central power area with 12 Volt LED Power Transformer to adequately drive the whole LED modules without Flicker.
(d )Internal Electrical Wiring will be done by Halogen Free Flame Retardent HRFR compound insulated (Unsheathed) 1.5 Sq.mm. copper flexible cable through interior conduit and Electrical Raceway.
Erection the above sign board with three nos. 40x40x6mm MS angle iron bracket the support on the back side rigidly grouted on suitable muffing which are making on the roof to avoid the uprooting by wind pressure and painting as per direction of EIC
Construction of base block foundation (6:3:1) of dimension 450X450X600 mm' partly below the ground level and partly above the G.L as muffing with 3mm thick net cement finishing as per direction of EIC
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required
50mm dia
65mm dia
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS
Connecting the equipments to earth busbar including S & F Solid GI (Hot Dip) wire of size as below as per GS
4SWG [5(a)(i)/G-2]
6 SWG [5(a)(ii)/G-2]
SUB-HEAD 6- SITC of INVERTER
Supply & Installation of 900VA sine wave, Led display Inverter complete set with 1 Nos. 25 Plate, 12V,150 Amp/Hr. battery incl. inverter trolly & allied works (Inverter Make – Microtek Digital UPS EB900VA, 12V or Equivalent product of EXIDE / LUMINOUS having similar specification in all respect)) & Battery Make - Exide- inva tubular IT 500, 150Ah or Equivalent product of AMRON / PANASONIC / LUMINOUS having similar specification in all respect))
S/F 250V 2nos 15A Plug top ( Make Anchor) incl S/D 1.5mtr, 3core 2.5sqmm pvc insulated cable and making necy connection for installation of Inverter.
TANISHA ENTERPRISE
PANDIT AND CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .