Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.9 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | Rejected-Technical | - | Rejected-Technical techno-commercially not qualified |
| Sl No | Description | Qty | Unit | BIRNS OCEANOGRAPHIC INC. L1 |
|---|---|---|---|---|
| 1.00Pressure Hull Penetrator for 6000m manned submersible Category-A-Power | ||||
| 2.00 | DNV Design drawings, Schematics, Fabrication drawings. (for Category-A)
Note: As per stage 1 payment terms, 10% of the contract value of the category A is the ceiling limit. | 1 | LUMPSUM | 83,125 ₹83,125 Lowest |
| 3.00 | Completion of Successful Type Testing as per DNV requirements along with DNV type testing certificate. (for Category-A)
Note: As per stage 1 payment terms, 20% of the contract value of the category A is the ceiling limit. | 1 | LUMPSUM | 1,66,251 ₹1,66,251 Lowest |
| 4.00 | Underwater Electrical Penetrator with ≥ (greater than or equal to) 34pins, (greater than or equal to) ≥10 A/ pin with 3 m long pigtails at one end (inboard side) and 8 m long underwater cable molded with suitable Cable Connector Plug (CCP – Male pins preferred) at the other end. | 6 | NOS | 1,74,222 ₹1,74,222 Lowest |
| 5.00 | Suitable mating Bulkhead Connector Receptacle (BCR – Female sockets preferred) with 1.5 m long pigtails | 6 | NOS | 14,808 ₹14,808 Lowest |
| 6.00 | Pressure Rated Dummies and dust caps for the Plug (CCP) and Receptacle (BCR)-(each set consisting of a pressure rated dummy & dust cap for CCP and a pressure rated dummy & dust cap for BCR) | 4 | Set | 6,884 ₹6,884 Lowest |
| 7.00 | Test cable of 5 m length with connector at one end and pigtails at the other end for CCP | 1 | NOS | 6,897 ₹6,897 Lowest |
| 8.00 | Test cable of 5 m length with connector at one end and pigtails at the other end for BCR | 2 | NOS | 13,418 ₹13,418 Lowest |
| 9.00 | Routine testing
Testing and DNV Certification charges.
Note: DNV certification is not required for test cables and dust caps. Testing for the same can be done as per manufacturer’s standards/test protocol. | 1 | LUMPSUM | 59,390 ₹59,390 Lowest |
| 10.00 | Power - 56 Pins Electrical Penetrator AssemblyUnderwater Electrical Penetrator with (greater than or equal to) ≥56 pins, (greater than or equal to) ≥ 5A/pin Underwater Electrical Penetrator with 3 m long pigtails at one end (Inboard side) and 8 m long underwater cable molded with suitable Cable Connector Plug (CCP – Female sockets preferred) at the other end. | 6 | Nos | 1,93,938 ₹1,93,938 Lowest |
Tender Value
Refer Docs
EMD Value
₹34.0 L
Closing Date
12 May 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Director
NATIONAL INSTITUTE OF OCEAN TECHNOLOGY VELACHERY TAMBARAM MAIN ROAD NARAYANPURAM, CHENNAI-600100
Pressure Hull Penetrators for 6000m Manned Submersible
2023_NIOT_742144_1
NIOT/HVT/1169R/22-23
Global Tenders
Electronic Components And Devices
Supply
330 days
NATIONAL INSTITUTE OF OCEAN TECHNOLOGY
As per tender clause
4 documents required · 4 mandatory
₹0
₹34.0 L
Yes
NIOT Chennai
6 Jul 2023
2 Mar 2023
12 May 2023
2 Mar 2023
12 May 2023
3 Mar 2023
2 Mar 2023 - 13 Mar 2023
15 Mar 2023
Pressure Hull Penetrator for 6000m manned submersible Category-A-Power
DNV Design drawings, Schematics, Fabrication drawings. (for Category-A) Note: As per stage 1 payment terms, 10% of the contract value of the category A is the ceiling limit.
Completion of Successful Type Testing as per DNV requirements along with DNV type testing certificate. (for Category-A) Note: As per stage 1 payment terms, 20% of the contract value of the category A is the ceiling limit.
Underwater Electrical Penetrator with ≥ (greater than or equal to) 34pins, (greater than or equal to) ≥10 A/ pin with 3 m long pigtails at one end (inboard side) and 8 m long underwater cable molded with suitable Cable Connector Plug (CCP – Male pins preferred) at the other end.
Suitable mating Bulkhead Connector Receptacle (BCR – Female sockets preferred) with 1.5 m long pigtails
Pressure Rated Dummies and dust caps for the Plug (CCP) and Receptacle (BCR)-(each set consisting of a pressure rated dummy & dust cap for CCP and a pressure rated dummy & dust cap for BCR)
Test cable of 5 m length with connector at one end and pigtails at the other end for CCP
Test cable of 5 m length with connector at one end and pigtails at the other end for BCR
Routine testing Testing and DNV Certification charges. Note: DNV certification is not required for test cables and dust caps. Testing for the same can be done as per manufacturer’s standards/test protocol.
Power - 56 Pins Electrical Penetrator AssemblyUnderwater Electrical Penetrator with (greater than or equal to) ≥56 pins, (greater than or equal to) ≥ 5A/pin Underwater Electrical Penetrator with 3 m long pigtails at one end (Inboard side) and 8 m long underwater cable molded with suitable Cable Connector Plug (CCP – Female sockets preferred) at the other end.
Suitable mating Bulkhead Connector Receptacle (BCR – Male pins preferred) with 1.5 m long pigtails
Pressure Rated Dummies and dust caps for the Plug (CCP) and Receptacle (BCR)-(each set consisting of a pressure rated dummy & dust cap for CCP and a pressure rated dummy & dust cap for BCR)
Test cable of 5m length with connector at one end and pigtails at the other end for CCP
Test cable of 5m length with connector at one end and pigtails at the other end for BCR
Routine testing Testing and DNV Certification Charges. Note: DNV certification is not required for test cables and dust caps. Testing for the same can be done as per manufacturer’s standards/test protocol.
Frieght and Insurance Lumpsum (supplier warehouse to NIOT warehouse) for Category A
TPI Charges (applicable only for the payment made through LC) for category A
GST(Applicable to Indian bidders)
Category-B – Twisted Pair and Ethernet
DNV Design drawings, Schematics, Fabrication drawings. (for Category-B) Note: As per stage 1 payment terms, 10% of the contract value of the category B is the ceiling limit.
Completion of successful Type Testing as per DNV requirements along with DNV type testing certificate. (for Category-B) Note: As per stage 1 payment terms, 20% of the contract value of the category B is the ceiling limit.
Penetrator for data interface with (greater than or equal to) ≥ 56 pins for 6 LAN cables (CAT 6 or better, 20 or 22 AWG) with 3 m long pigtails of 28 twisted pair cables at one end (inboard side of the pressure hull) and 8m long underwater communication cable molded with suitable Cable Connector Plug (CCP – Female sockets preferred) at the other end.
Suitable mating Bulkhead Connector Receptacle (BCR – Male pins preferred) with 1.5 m long pigtails of twisted pair cables, with overall common shield.
Pressure Rated Dummies and dust caps for the Plug (CCP) and Receptacle (BCR)-(each set consisting of a pressure rated dummy & dust cap for CCP and a pressure rated dummy & dust cap for BCR)
Test cable of 5 m length with connector at one end and pigtails at the other end for CCP
Test cable of 5 m length with connector at one end and pigtails at the other end for BCR
Routine testing Testing and DNV Certification Charges. Note: DNV certification is not required for test cables and dust caps. Testing for the same can be done as per manufacturer’s standards/test protocol.
Ethernet Penetrator AssemblyPenetrator for Ethernet communication with (greater than or equal to) ≥ 54 pins for 6 LAN cables (CAT6 or better, 20 or 22 AWG), each LAN cable consisting of 4 Twisted pairs with an overall common shield and 3m long pigtails of RJ-45 connector at one end (inboard side of the pressure hull) and 8m long underwater communication cable molded with suitable Cable Connector Plug (CCP – Female sockets preferred) at the other end.
Suitable mating Bulkhead Connector Receptacle (BCR – Male pins preferred) with 1.5 m long pigtails with RJ-45 connector of 6 LAN cables, each cable consisting of 4 Twisted pairs and overall common shield.
Pressure Rated Dummies and dust caps for the Plug (CCP) and Receptacle (BCR)-(each set consisting of a pressure rated dummy & dust cap for CCP and a pressure rated dummy & dust cap for BCR)
Test cable of 5 m length with connector at one end and pigtails at the other end for CCP
Test cable of 5 m length with connector at one end and pigtails at the other end for BCR
Routine testing Testing and DNV Certification Charges. Note: DNV certification is not required for test cables and dust caps. Testing for the same can be done as per manufacturer’s standards/test protocol.
Freight and Insurance Lumpsum (supplier warehouse to NIOT warehouse) for Category-B.
TPI Charges (applicable only for the payment made through LC) for Category-B.
GST(Applicable to Indian bidders)
Category-C – Coaxial
DNV Design drawings, Schematics, Fabrication drawings. (for Category-C) Note: As per stage 1 payment terms, 10% of the contract value of the category c is the ceiling limit.
Completion of successful Type Testing as per DNV requirements along with DNV type testing certificate. (for Category-C) Note: As per stage 1 payment terms, 20% of the contract value of the category C is the ceiling limit.
Penetrator with (greater than or equal to) ≥ 4 coaxial interfaces with suitable coaxial cable capable of handling HD/SD video and data with 3 m long pigtails and BNC connector at one end (inboard side) and 8m long underwater coaxial cable molded with suitable Cable Connector Plug (CCP– Female sockets preferred) at the other end. Note - Details of the coaxial interfaces required: • Co-axial cable for HD/ SD Video – RG59/179, 75 Ω, min 3.0 GHz or better – ≥ 2 ways • Co-axial cable for VHF communication – RG58/178, 50 Ω, 200 MHz or better – ≥ 2 ways (or) Non-Impedance matching pins at connector/penetrator and standard coaxial cables shall be used.
Suitable mating Bulkhead Connector Receptacle (BCR – Male pins preferred) having 1.5 m long pigtails with BNC connectors at the end.
Pressure Rated Dummies and dust caps for the Plug (CCP) and Receptacle (BCR)-(each set consisting of a pressure rated dummy & dust cap for CCP and a pressure rated dummy & dust cap for BCR)
Test cable of 5 m length with connector at one end and pigtails with BNC connector at the other end for CCP
Test cable of 5 m length with connector at one end and pigtails with BNC connector at the other end for BCR
Routine testing Testing and DNV Certification Charges. Note: DNV certification is not required for test cables and dust caps. Testing for the same can be done as per manufacturer’s standards/test protocol.
Freight and Insurance Lumpsum (supplier warehouse to NIOT warehouse) for Category-C.
TPI Charges (applicable only for the payment made through LC) for Category-C.
GST(Applicable to Indian bidders)
Category-D -Fibre Optics
DNV Design drawings, Schematics, Fabrication drawings. (for Category-D) Note: As per stage 1 payment terms, 10% of the contract value of the category D is the ceiling limit.
Completion of successful Type Testing as per DNV requirements along with DNV type testing certificate. (for Category D) Note: As per stage 1 payment terms, 20% of the contract value of the category D is the ceiling limit
Single Mode Optical Fibre Penetrator with (greater than or equal to) ≥10 ways, 9/125 μm with 3m long pigtails and ST Connector at one end (inboard side) and 8 m long underwater fibre optic cable molded with suitable Cable Connector Plug (CCP – Female sockets preferred) of equivalent number of single mode contacts at the other end.
Suitable mating fibre Optic Bulkhead Connector Receptacle (BCR – Male pins preferred) with single mode contacts and 1.5m long pigtails with ST Connector.
Pressure Rated Dummies and dust caps for the Plug (CCP) and Receptacle (BCR)-(each set consisting of a pressure rated dummy & dust cap for CCP and a pressure rated dummy & dust cap for BCR)
Test cable of 5 m length with fibre optic connector at one end and pigtails with ST connector at the other end for CCP
Test cable of 5 m length with fibre optic connector at one end and pigtails with ST connector at the other end for BCR
Routine testing Testing and DNV Certification Charges. Note: DNV certification is not required for test cables and dust caps. Testing for the same can be done as per manufacturer’s standards/test protocol.
Freight and Insurance Lumpsum (supplier warehouse to NIOT warehouse) for Category-D.
TPI Charges (applicable only for the payment made through LC) for Category-D.
GST(Applicable to Indian bidders)
US Dollar
European Euro
British Pound
Norwegian Kroner
Portion of Quoted Rate in Currency
US Dollar
European Euro
British Pound
Norwegian Kroner
Portion of Quoted Rate in Currency
US Dollar
European Euro
British Pound
Norwegian Kroner
Description of Work / Item(s)
GST(Applicable to Indian bidders)
DNV Design drawings, Schematics, Fabrication drawings. (for Category-B) Note: As per stage 1 payment terms, 10% of the contract value of the category B is the ceiling limit.
Completion of successful Type Testing as per DNV requirements along with DNV type testing certificate. (for Category-C) Note: As per stage 1 payment terms, 20% of the contract value of the category C is the ceiling limit.
DNV Design drawings, Schematics, Fabrication drawings. (for Category-D) Note: As per stage 1 payment terms, 10% of the contract value of the category D is the ceiling limit.
Single Mode Optical Fibre Penetrator with (greater than or equal to) ≥10 ways, 9/125 μm with 3m long pigtails and ST Connector at one end (inboard side) and 8 m long underwater fibre optic cable molded with suitable Cable Connector Plug (CCP – Female sockets preferred) of equivalent number of single mode contacts at the other end.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .