Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.6 LAccepted-AOC | L1 | Accepted-AOC BEING L1 BIDDER | |
| 2 | L2₹41.1 L+₹3.4 L (9.01%)Rejected-Finance MES CHOWPATTI HASIMARA DIST JALPAIGURI WB PIN 735215 | HASIMARA | JALPAIGURI | WEST BENGAL | 735215 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹43.0 L+₹5.3 L (14.0%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹44.1 L+₹6.4 L (17.0%)Rejected-Finance 21 JHAMRI 151 JHAMRI JHAMRI ROHTAK HARYANA 124142 UDYAM HR 07 0030314 | JHAJJAR | HARYANA | 124142 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹44.1 L+₹6.4 L (17.0%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹39.5 L
EMD Value
₹79,000
Closing Date
5 Jul 2024, 6:00 pmClosed
GE (AF) HASIMARA
GE (AF) HASIMARA PO-HASIMARA DIST- ALIPURDUAR PIN-735215
REPAIR/MAINT OF STROM WATER DRAINS INCLUDING REPLACING OF DAMAGED BRICK LININGS AT KV AREA, REPAIR/MAINT INCL CONVERSION OF DAMAGED ALUMINUM INTERNAL WIRING IN VARIOUS BLAST PENS, REPAIRS/MAINT OF SANITARY FITTINGS, PLUMBING AND FLOORS OF WASHROOM
2024_MES_656677_2
C/8767/2024-25/E8
Open Tender
Civil Works
Item Rate
210 days
GE (AF) HASIMARA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) HASIMARA
₹79,000
Yes
2 Sept 2024
21 Jun 2024
8 Jul 2024
21 Jun 2024
5 Jul 2024
28 Jun 2024
Amount
Taking down cement plaster on brick or concrete surfaces including racking out joints hacking for key scrubbing down with water etc, complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars, manholes etc., separation of serviceable materials from the unserviceable, stacking the serviceable materials within 100m and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100m, complete all as specified and directed.
Dismantling of floor, hearth or wall tiles including cement mortar bedding ( but not backing) and remvoing rubbish off the premishes, complete all as specified and directed.
M&L for brick work with sub class 'B' bricks, old size, straight or curved on plan exc 6 mtr mean radius built in CM (1:6), complete all as specified and directed.
All as per item No. 4.00 here-in-before but except bricks, complete all as specified and directed. Note-(i) Bricks obtained from demolition shall be re-used. (ii) The quoted rate shall deemed to be included for cleaning of old bricks obtained from demolition.
M&L 15mm thick rendering in CM (1:6) on fair faces of brick work or concrete surfaces finished surfaces fair and even, complete all as specified and directed.
M&L 15mm thick rendering in CM (1:4) on fair faces of brick work or concrete surfaces finished surfaces fair and even, complete all as specified and directed.
M & L for rendering 15mm thick (10mm + 5mm) in two coats on fair faces of brick work or concrete surfaces of wall in CM (1:4), mixed with integral water proofing compound at top layer as per manufacturer's instructions and finished the surface even and fair without using extra cement, complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item as supply only.)
Supply only liquid water proofing compound conforming to IS: 2645 - 1975 specification, complete all as directed
M&L for rendering 5mm thick in CM (1:3) on ceiling surfaces, finished even and smooth (without using extra cement), complete all as specified and directed.
M&L for preparing newly plastered wall surfaces and applying two coats of acrylic distemper over and including a coat of 2mm thick wall care putty, complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash, complete all as specified and directed.
M & L for preparation of newly plastered of wall surfaces and applying two coats of 100% acrylic smooth exterior emulsion paint (as per manufacturer's instructions) alkali & fungal resistance of approved colour shade (pattern deep green/camouflage) over a coat of exterior emulsion primer (as per manufacturer's instructions), complete all as specified and directed.
M&L for complete removal of existing treatment of wall surfaces and applying two coats of acrylic distemper over and including a coat of 2.0mm thick wall care putty including making good any undulation by rubbing with sand paper to obtained smooth & plain surfaces, complete all as specified and directed.
M&L for preparation of old plastered surfaces of wall and applying one coat of 100% acrylic smooth exterior emulsion paint (as per manufacturer's instructions) alkali & fungal resistance of approved colour shade (pattern deep green/camouflage), complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement of match the surfaces over and including 15mm thick screed bed in CM (1:6), complete all as specified and directed.
M&L glazed ceramic coloured tiles in vertical surface 350 x 250 x 7mm/450 x 350 x 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering back coat in CM (1:4), complete all as specified and directed.
M&L for coloured non skid ceramic tiles 10mm thick (square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement of match over and including 15mm thick screed bed in CM (1:6), complete all as specified and directed.
M&L for coloured non skid ceramic tiles 10mm thick (square/rectangular) polished, vertical surface skirting/dado, area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement pigment to match laid over and including 10mm thick rendering in CM (1:4), complete all as specified and directed.
Taking down chowkhats or frame with shutter (without taking off shutters from frame) exc 1 & n.exc 2 Sqm each, complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads, complete all as specified and directed.
S&F 3mm thick plain sheet glass, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm. in each pane, complete all as specified and directed.
S&F solid PVC door frame of size 50mm X 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tubes, as per specifications and drawing, complete all as specified and directed
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing, complete all as specified and directed.
S&F 150mm long aluminium anodised, barrel tower bolt of extruded section, complete all as specified and directed.
S&F 100mm long aluminium anodised, barrel tower bolt of extruded section, complete all as specified and directed.
S&F 100mm size MS butt hinge, medium weight, cold rolled mild steel, complete all as specified and directed.
S&F 150 mm long aluminium handle cast type anodised, complete all as specified and directed.
Taking down 15mm bore steel water tubing and connection from wall/ceiling surfaces including cleaning for re-fixing or removing from site of work, complete all as specified and directed.
Taking down 20mm bore steel water tubing and connection from wall/ceiling surfaces including cleaning for re-fixing or removing from site of work, complete all as specified and directed.
S&F CPVC pipe of size 16mm dia in trenches high pressure CPVC pipes SDR-11 & plain CPVC SDR 11 fittings including all necessay fittings, like elbow, tee, socket, reducer, bushings, step over bends, end caps, end plugs, etc and with CPVC solvents cement, complete all as specified and directed.
S&F CPVC pipe of size 20mm dia in trenches high pressure CPVC pipes SDR-11 & plain CPVC SDR 11 fittings including all necessay fittings, like elbow, tee, socket, reducer, bushings, step over bends, end caps, end plugs, etc and with CPVC solvents cement, complete all as specified and directed.
Cutting chases, pinning in, making good to facings in stone concrete wall / blocks / slab where required and pointing in CM (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc, and making good, cutting n.exc 10cm girth, complete all as specified and directed.
S&F in repairs 20mm dia gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed.
Cleaning and removing all scale and dirt etc, from tanks of capacity exc. 500 ltr but n. exc. 1000 ltr, and from mouths of circulating pipes etc using edible bleaching powder/liquid and washing with water, writing the item "Tank Cleaned on ____" indicating the date, month & year of cleaning on external surface of tank walls with synthetic enamel paint, complete all as specified and directed.
Cleaning and removing all scale and dirt etc, from tanks of capacity exc. 250 ltr but n. exc. 500 ltr, and from mouths of circulating pipes etc using edible bleaching powder/liquid and washing with water, writing the item "Tank Cleaned on ____" indicating the date, month & year of cleaning on external surface of tank walls with synthetic enamel paint, complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks, triple layered, (cylindrical vertical with closed top) ISI marked, confirming to IS 12701-1989, hoisted and fixed in position all as specified in SSR Part I (1000 ltr capacity) including 20mm Nipple suitable for HDPE water tank and 20mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe and fixed to 20mm bore pipe inculding dismantling of old water tank, complete all as specified and directed.
S&F in repair 15mm bore bib taps, two way, cast copper alloy, chromium plated, screwed down, screwed for iron pipe, compelete all as specified and directed.
S&F vitreous china ware wash hand basin white, flat back, size 580 x 450mm size (flat back or angle back type) including cutting for and pinning ends of brackets or erecting stand including pedestal, complete all as specified.
S & F in repair vitreous china urinal, bowl type flat back of size 465 x 355 x 265mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) including urinal spreader, providing and fixing plugs, bedding urinal against wall in CM (1:2), securing urinal to plug with and including 60mm long brass screws, pointing around urinal back, complete all as specified and directed.
S&F in repair vitreous china EWC (padestal pattern) white including seat and cover, flushing cistern, flush pipe, 'P' or 'S' trap and including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe etc including making good distrubed surfaces, complete all as specified and as directed.
S&F in repair vitreous china wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe etc, complete all as specified and as directed.
S&F in repair 10 ltrs capacity low level valve less PVC syphonic action type flushing cistern white with inlet ball valve, float and handle and connection to pipes, complete all as specified and directed.
S&F in repair 32mm dia waste fittings, brass, chromium plated for glazed ware sinks, basins etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed, complete all as specified and directed.
S & F in repairs, 15mm bore, PVC connection pipe 450mm long with PTMT nuts at both ends, complete all as specified and directed.
S&F in repair 15mm bore, bib tap, fancy type, chromium plated, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or union, complete all as specified and directed.
S&F in repair 15mm bore, fancy type, chromium plated, stop valves, with long shank and cup concealed type, cast copper alloy, screwed dow,n high pressure with crutch or butterfly handle screwed both ends for iron pipe or union, complete all as specified and directed.
S&F in repairs 15mm dia bore for pillar taps, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down, high pressure, with or without lettered ‘HOT’ or ‘COLD’ with long screwed shanks and fly–nuts, screwed on iron pipe, complete all as specified and directed.
S&F in repairs for 15mm dia pipe, health faucet (ABS Body) mild steel chromium plated suitable with 1.25 metre long flexible tube and ABS wall hook including makeing connection and fixed in position, complete all as specified and directed.
S&F in repair towel rail, 600mm long PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 190gms), complete all as specified and directed
S&F in repair towel ring of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 90gms), complete all as specified and directed
S&F shelf of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 300gms), complete all as specified and directed
S&F in repair 125mm chromium plated shower roses with or without swivel joints, any size, including fixing to any type of pipe or union, complete all as specified and directed.
S&F in repair 140mm grating round of PTMT (minimum weight 50gms), complete all as specified and directed.
S&F in repair 100mm dia cast iron floor trap / Nahani trap with grating including jointing to waste pipe fixed in PCC (1:2:4), type B-1, compelete all as specified and directed.
S & F 110mm bore PVC SWR pipe, single socketed, in any length with rubber ring joint, fixed to wall with and including clamps, complete all as specified and directed.
S&F in repair of 110mm bore, PVC (SWR) bends of any radius, complete all as specified and directed.
M &L PCC (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) as in padding etc, finished even and smooth without extra cement, complete all as specified and directed.
Taking out old damaged tarfelt or membran of any description including screed bed or bedding layer and removing of debris to a distance exc. 50m and n. exc. 100m and cleaning roof surfaces to remove all loose dust etc., roughening surfaces of old concrete roof by picking, sweeping clean and washing down with water using wire brush, brooming down and applying the following treatment all as directed in order of precedence as stated: (a) Brushing neat cement slury with 3.0 kg of cement per Sqm. (b) 15mm thick screed bed or bedding layer in CM (1:4) mixed with water proofing compound as per manufacturer instruction on existing roof surface true to level. (c) Applying one coat of bituminous primer @ 0.40 Ltr/Sqm. (d) Supply and laying 3mm thick APP based polymeric membrane of approved manufactured with weight not less than 3.50 Kgs per Sqm reinforced with non-woven polyester fabric weighing not less than 160gms per Sqm having softening point not less than 15°C, having tensile strength of 650 N/Sqcm and 350 N/Sqcm in longitudinal and transverse directions respectively of the reinforced tearing strength of 180 N by torch application. Polymeric membrane shall be taken to a height of 30cm (minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. (e) Applying one coat of aluminium paint @ 0.11 Kg/Sgm over APP membrane surface. Note:- (i) Laying APP based polymeric membrane shall be done torch on method as per manufactures instructions. (ii) A minimum overlap of 150mm and 100mm should be made at the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as per manufacturers instruction. (iii) APP based polymeric membrane shall be of any one of the approved makes as specified here-in-after and shall conform to specifications given in IS 16540-2017/1S 16532 2017. (iv) Contractor shall produce necessary test certificate of the manufacturer to the Engr-in-Charge before incorporation in the work. (v) Necessary independent tests shall also be carried out by the contractor without any extra cost to the Deptt as per relevant IS specifications and membranes with satisfactory test results shall only be incorporated in the work. (vi) The work shall be executed through authorised applicators of original manufacturer only. (viI) WPC shall be measured and paid separately as supply only.
Removal of vegetation/grass etc including cutting holes into or through brick walls/concrete and removal of small trees/woods etc and making good disturbed surfaces with PCC (1:2:4), type B-0 (using 12.5mm graded crushed stone aggregate) surface area n. exc. 0.50 Sqm, complete all as specified and directed.
M&L for 6mm thick pre-painted E-fibre board, designer/decorative, fixed or laid/inserted to GI snap grid frame size 605x605 mm work for false ceiling hangers with 4mm to 6mm dia. G.I. (length as required) adjusting level, fixed to roof slabs/truss by means of ceilling cleats made out of G.I. flat 40 x 3mm size 60mm long and expansion hold fasteners, 12.5mm dia, 40mm long including dismentaling of existing unserviceable ceiling boards of any thickness including cover fillets, complete all as specified and directed.
Demolition of bricks (laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons, etc. (each layer) laid dry or pointed, complete all as specified and directed.
M&L for brick work with, sub class 'B' bricks, old size, laid flat and bedded and jointed in cement mortar (1:6) and pointed in cement mortar (1:3) in drains, channels, kerbs etc, complete all as specified and directed.
All as per item No 64.00 here-in before but except bricks, complete all as specified and as directed. Note-(i) Bricks obtained from demolition shall be re-used. (ii) The quoted rate shall deemed to be included for cleaning of old bricks obtained from demolition.
M&L for brick work with, sub class 'B' bricks, old size, laid on edge and bedded and jointed in cement mortar (1:6) and pointed in cement mortar (1:3) in drains, channels, kerbs etc, complete all as specified and as directed.
All as per item No 66.00 here-in before but except bricks, complete all as specified and as directed. Note-(i) Bricks obtained from demolition shall be re-used. (ii) The quoted rate shall deemed to be included for cleaning of old bricks obtained from demolition.
M&L for racking out joints/pointing to brick work or brick tiles laid flat, in floors, surface channels, roofs, etc in cement mortar and flush pointing to bricks laid flat or brick tiles in paving in cement mortar (1:4), complete all as specified and directed.
M&L for racking out joints/pointing to brick work in walls or to bricks on edge in floors, surface channels, roofs, etc and flush pointing to brick on edge paving in cement mortar (1:4), complete all as specified and directed.
M&L for brick work with sub class 'B' bricks, straight or curved on plan to any radius, built in cement mortar (1:4) as in half brick thick walls, complete all as specified and directed.
M&L for PCC (1:2:4), type B-1. (using 20mm graded crushed stone aggregate) as in benching. coping, bed plate, lintel upto 1.5m span cast, in situ including necessary form work, complete all as specified and directed.
Demolition of un-reinforced cement concrete of any description not otherwise specifically provided for and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100m, complete all as specified and directed.
M&L PCC (1:2:4) type C1 (using 40mm graded crushed stone aggregate) as in surface chanel, drains etc., complete all as specified and directed.
M & L for extra for forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms moulds, mitred/stopped ends etc, complete all as specified and as directed
Add or deduct from item No. 73.00 here-in-before for each 25mm girth or part thereof over or under 30cm girth, complete all as specified and as directed
M & L for PCC (1:3:6), type C 2, (using 40mm graded crushed stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 300mm bore RCC pipe, complete all as specified and directed.
S&F 300mm bore reinforced concrete pipes, class NP2 laid and jointed complete with collar, complete all as specified and directed.
M & L 75mm thick PCC (1:3:6), type B 2, (using 40mm graded crushed stone aggregate) as in path, drain sides, plinth protections etc.finishing cement concrete surface even and smooth without using extra cement , complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position, disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100m, complete all as specified and directed. (Note:- Reinforcement shall be cut as required to facilitate demolition.)
Use & waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, endings and similar work not exceeding 200mm thick (horizontal of sloping) for flat rough finished surfaces of concrete,complete all as specified and directed.
M&L for RCC (1:1.5:3) type B1, (using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies and in shelves and the like,complete all as specified and directed.
M&L for pre-cast RCC (1:2:4), type B-1 (using 20mm graded crushed stone aggregate) as in cover slab of drain, manholes etc and set in cement mortar (1:4) including necessary form, moulds, etc, complete all as specified and directed. (Note : Reinforcement shall bemeasured and paid separately)
S & F mild steel TMT bars 10mm dia (Grade Fe-500D), cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia., or securing with clips, complete all as specified and directed.
S & F mild steel TMT bars 6mm to 8mm dia (Grade Fe-500D), cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia., or securing with clips, complete all as specified and directed.
Demolition of stone slabs and tiles of any description or aprons thickness in floors etc laid bedded and pointed in any mortar, complete all as directed specified and
M&L for chequered cement concrete tiles 30cm x 30cm x 25cm thick set jointed and pointed in near cement slurry with pigment in floors over and including 15mm thick screed bed in CM (1:6), complete all as specified and directed
Taking down carefully copper/aluminium point wiring complete (light,fan, plug point & power complete alongwith fittings (switches, ceiling roses, tube light fittings, bulk head fitting regulator, sockets main switches, DB removing materials to store & making good of disturb surfaces of wall/floors etc, complete all as specified and directed.
M & L for point wiring complete with PVC insulated unsheathed, 1100 volts grade cable 1.5 Sqmm (nominal area) FRLSH type multi stranded copper conductor, single core drawn in and including PVC casing caping (ISI marked) , heavy duty of adequate size including its accessories not less than 20mm dia rigid PVC conduit 'medium grade ISI marked including all conduit accessories including pressed steel terminal box of required size factory made with top cover of ISI marked plastic laminated sheet of required colour for mounting switch, sockets, fan regulator etc including 1.5 Sqmm FRLSH type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire and connected to earth dolly as required at site & including chases cutting & making good disturbed surface & applying finishes to match existing surface etc. for one light/fan point controlled by one, one way switch single pole, complete all as specified and directed.
All as per item No 88.00 here-in before but one 3 pin 5 Amps socket outlet on the same board with other switches, complete all as specified and directed.
All as per item No 88.00 here-in before but one 3 pin 5 Amps socket outlet on the indepandent board, complete all as specified and directed.
All as per item No 88.00 here-in before but one bell/buzzer point controlled by one push button on the same board with other switches or independent, complete all as specified and directed.
All as per ser item No. 88.00 here-in before but for one 16 Amp 3/5 pin switch socket outlet independent point including PVC cable 4 Sqmm FRLSH type copper stranded conductor along with 4 Sqmm continious PVC insulated unsheathed standard copper conductor cable FRLSH type for as earth wire, complete all as specified and directed.
M & L for point wiring complete with PVC insulated unsheathed, 1100 volts grade cable 1.5 Sqmm (nominal area) FRLSH type multi stranded copper conductor, single core drawn in and including PVC conduit, medium grade, (ISI marked) , heavy duty of adequate size including its accessories not less than 20mm dia rigid PVC conduit 'medium grade ISI marked including all conduit accessories including pressed steel terminal box of required size factory made with top cover of ISI marked plastic laminated sheet of required colour for mounting switch, sockets, fan regulator etc including 1.5 Sqmm FRLSH type PVC insulated unsheathed cable multi-stranded copper conductor as continuous earth wire and connected to earth dolly as required at site & including chases cutting & making good disturbed surface & applying finishes to match existing surface etc. for one light/fan point controlled by one, one way switch single pole, complete all as specified and directed.
All as per item No 93.00 here-in before but one 3 pin 5 Amps socket outlet on the same board with other switches, complete all as specified and directed.
All as per item No 93.00 here-in before but one 3 pin 5 Amps socket outlet on the indepandent board, complete all as specified and directed.
All as per item No 93.00 here-in before but one bell/buzzer point controlled by one push button on the same board with other switches or independent, complete all as specified and directed.
All as per ser item No. 93.00 here-in before but for one 16 Amp 3/5 pin switch socket outlet independent point including PVC cable 4 Sqmm FRLSH type copper stranded conductor along with 4 Sqmm continious PVC insulated unsheathed standard copper conductor cable FRLSH type for as earth wire, complete all as specified and directed.
S&F switch piano flush button single pole one way 6 amps 240 volts, complete all as specified and directed.
S&F socket outlet 2 in 1, 3 pin 6 Amp, 240 volts, flush type, complete all as specified and directed.
S&F switch socket combination 2 in 1, 5 pin 6 Amp, 240 volts, flush type, complete all as specified and directed.
S&F switch socket combination 3 pin, 16 Amp, 240 volts, flush type, complete all as specified and directed.
S&F ceiling rose, surface bakelite PVC/polycarbonate, isolated body with three terminals, complete all as specified and directed.
S&F lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed.
S&F step type electronic fan regulator, flush type, AC 240 volt complete all as specified and directed.
S&F bell push 5 Amp flush type, complete all as specified and directed.
S&F bell electric, heavy duty, ding dong type, 240 volt, single pole, complete all as specified and directed.
Supply and draw sub main wiring in repairs of two run 6.0 sqmm single core FRLSH PVC insulated, unsheathed multistranded copper conductor cable 1100 Volt grade, drawn through and including PVC conduit (ISI marked) medium duty and accessories of not less than 25mm size including all conduit accessories for concealed to the surfaces of the wall/ceiling including one run of 6.0 sqmm single core PVC insulated unsheathed copper earth continuity including making good disturbed surface including taking down existing sub-main wiring, any numbers of wire and any size, complete all as specified and directed. (Note: Two runs of single core cable with one run of earth continuity conductor including PVC conduit & accessories shall be measured and paid as one length.)
All as per item No 107.00 here-in before but drawn through and including PVC casing caping (ISI marked) heavy duty, including its accessories, complete all as specified and directed.
S&F MCB distribution board (DB), SPN with sheet metal encloser, double door, IP 43 protection & IK 09, 240 volts, 04 way, single pole and neutral, with 200 Amps rated busbar (as per OEM), neutral link for fixing MCBs/Isolators including taking down old unserviceable MCB DB of any description, complete all as specified and directed.
S&F MCB distribution board (DB), SPN with sheet metal encloser, double door, IP 43 protection & IK 09, 240 volts, 08 way, single pole and neutral, with 200 Amps rated busbar (as per OEM), neutral link for fixing MCBs/Isolators including taking down old unserviceable MCB DB of any description, complete all as specified and directed.
S&F MCB distribution board (DB) TPN with sheet metal encloser, double door, IP 43 protection & IK 09, 240 volts, 04 way, single pole and neutral, with 200 Amps rated busbar (as per OEM), neutral link for fixing MCBs/Isolators including taking down old unserviceable MCB DB of any description, complete all as specified and directed.
S&F MCB Triple Pole and Neutral (TPN) of capacity 65 to 70 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, complete all as specified and directed.
S&F MCB Single Pole and Neutral (SPN) of capacity 40 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, complete all as specified and directed.
S&F MCB Single Pole and Neutral (SPN) of capacity 63 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, complete all as specified and directed.
S&F MCB Single Pole (SP) of capacity 6 to 32 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, complete all as specified and directed.
S & F wall mounted LED light fitting 1 x 20 Watt, 4 feet long, 220V, AC with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose including taking down old unserviceable light fittings, complete all as specified and directed.
Cutting chases, pinning in, making good to facings in stone concrete wall / blocks / slab where required and pointing in CM (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc, and making good, cutting exc 10cm but n.exc 20cm girth, complete all as specified and directed.
Note: An amount of Rs.43,178.00 on account of Credit Schedule for schedule 'A' part - II shall be deducted from the total amount of BOQ to arrive at the contract sum.
BHARAT ELECTRIC
M/S. NARENDRA KUMAR GARG
M/S. KUMAR CONSTRUCTION CO.
B L SHARMA
M/S BISHAL ENTERPRISES
M/S RATHIN ENTERPRISES
SHRI PARTHA DUTTA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .