Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.8 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹30.8 L+₹1.1 L (3.69%)Rejected-Finance | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹32.4 L+₹2.6 L (8.79%)Rejected-Finance | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹33.9 L+₹4.2 L (14.1%)Rejected-Finance ATLANTIS A2 1501 PLOT NO 05 SECTOR 11 NEAR CLOUD 36 GHANSOLI NAVI MUMBAI 400 701 E 97 CWE SUBS BHANDUP | THANE | MAHARASHTRA | 400701 | L4 | Rejected-Finance Being not lowest | |
| 5 | L5₹34.0 L+₹4.3 L (14.4%)Rejected-Finance VILL RATTANPUR PO TEH JOURIAN DISTT JAMMU J K 181202 | JAMMU | JAMMU AND KASHMIR | 181202 | L5 | Rejected-Finance Being not lowest |
| Sl No | Description | Qty | Unit | NOEL ENGINEERS L3 | Sagar Electricals L10 | SUNRISE CONSTRUCTION CO L2 | Rama Construction Co L5 | HINDUSTAN BUILDERS L4 | SHREE SHIV SHANKER ENTERPRISE L7 | N.S.ENTERPRISES L8 | Sri Krishna Construction L1 | Minal Engineers L6 | GANGAJAL L9 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supplying, laying, testing & commissioning of LT under ground XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor 1100 volt grade 3.5 core x 120 sqmm laid in ducts fixed with saddle & clamps or passing through pipes complete with brass compression gland & proper lugs, nuts, bolts, washers completed including taking down/out old cable, complete all as specified and directed. | 150 | RM | 680 ₹1,02,000 | 730 ₹1,09,500 | 600 ₹90,000 | 550 ₹82,500 | 450 ₹67,500 | 550 ₹82,500 | 810 ₹1,21,500 | 570 ₹85,500 | 400 ₹60,000 Lowest | 865 ₹1,29,750 |
| 2.00 | All as per item No. 1 above but 3.5 core x 95 sqmm. | 140 | RM | 590 ₹82,600 | 620 ₹86,800 | 500 ₹70,000 | 400 ₹56,000 | 420 ₹58,800 | 480 ₹67,200 | 710 ₹99,400 | 450 ₹63,000 | 350 ₹49,000 Lowest | 617 ₹86,380 |
| 3.00 | All as per item No. 1 above but 3.5 core x 70 sqmm. | 100 | RM | 550 ₹55,000 | 460 ₹46,000 | 400 ₹40,000 | 350 ₹35,000 | 380 ₹38,000 | 380 ₹38,000 | 400 ₹40,000 | 360 ₹36,000 | 300 ₹30,000 Lowest | 555 ₹55,500 |
| 4.00 | All as per item No. 1 above but 3.5 core x 50 sqmm. | 52 | RM | 330 ₹17,160 | 346 ₹17,992 | 300 ₹15,600 | 300 ₹15,600 | 300 ₹15,600 | 280 ₹14,560 | 360 ₹18,720 | 274 ₹14,248 Lowest | 275 ₹14,300 | 485 ₹25,220 |
| 5.00 | Supplying, laying, testing in repair FR multistranded single core copper Three run conductor of size 6 Sqmm PVC sheathed un-armoured, 1100 volt grade, with RYB laid in floors/ducts or walls fixed with saddle & clamps or passing through pipes/flexible PVC pipe in concealed wiring complete with brass thimbles/lugs, nuts, bolts, washers, complete all as specified and directed. | 200 | RM | 240 ₹48,000 | 120 ₹24,000 Lowest | 200 ₹40,000 | 150 ₹30,000 | 300 ₹60,000 | 210 ₹42,000 | 300 ₹60,000 | 190 ₹38,000 | 150 ₹30,000 | 385 ₹77,000 |
| 6.00 | Supplying, laying, testing in repair FR multistranded single core copper Three run conductor of size 10 Sqmm PVC sheathed un-armoured, 1100 volt grade, with RYB laid in floors/ducts or walls fixed with saddle & clamps or passing through pipes/flexible PVC pipe in concealed wiring complete with brass thimbles/lugs, nuts, bolts, washers, complete all as specified and directed. | 200 | RM | 380 ₹76,000 | 150 ₹30,000 Lowest | 300 ₹60,000 | 200 ₹40,000 | 575 ₹1,15,000 | 225 ₹45,000 | 430 ₹86,000 | 320 ₹64,000 | 210 ₹42,000 | 475 ₹95,000 |
| 7.00 | Supplying, laying, testing in repair FR multistranded single core copper Three run conductor of size 16 Sqmm PVC sheathed un-armoured, 1100 volt grade, with RYB laid in floors/ducts or walls fixed with saddle & clamps or passing through pipes/flexible PVC pipe in concealed wiring complete with brass thimbles/lugs, nuts, bolts, washers, complete all as specified and directed. | 200 | RM | 520 ₹1,04,000 | 180 ₹36,000 Lowest | 500 ₹1,00,000 | 220 ₹44,000 | 650 ₹1,30,000 | 250 ₹50,000 | 610 ₹1,22,000 | 520 ₹1,04,000 | 180 ₹36,000 Lowest | 647 ₹1,29,400 |
| 8.00 | S&F in repair 2000 ltr capacity rotational moulded polyethelene water storage tank cynlindrical vertical with closed top Tripled layered, white colour (inside & outside of tank), hoisted and fixed in position including float valve of suitable size, complete all as specified and directed. | 10 | Each | 14,000 ₹1,40,000 | 20,000 ₹2,00,000 | 12,000 ₹1,20,000 | 12,000 ₹1,20,000 | 12,000 ₹1,20,000 | 12,000 ₹1,20,000 | 7,000 ₹70,000 Lowest | 11,000 ₹1,10,000 | 20,500 ₹2,05,000 | 14,000 ₹1,40,000 |
| 9.00 | S&F in repair 1000 ltr capacity rotational moulded polyethelene water storage tank cynlindrical vertical with closed top Tripled layered, white colour (inside & outside of tank), hoisted and fixed in position including float valve of suitable size, complete all as specified and directed. | 5 | Each | 7,500 ₹37,500 | 10,000 ₹50,000 | 8,000 ₹40,000 | 6,000 ₹30,000 | 6,000 ₹30,000 | 6,000 ₹30,000 | 4,000 ₹20,000 Lowest | 5,500 ₹27,500 | 15,000 ₹75,000 | 7,777 ₹38,885 |
| 10.00 | S&F in repair 500 ltr capacity rotational moulded polyethelene water storage tank cynlindrical vertical with closed top Tripled layered, white colour (inside & outside of tank), hoisted and fixed in position including float valve of suitable size, complete all as specified and directed. | 2 | Each | 4,500 ₹9,000 | 5,000 ₹10,000 | 4,500 ₹9,000 | 3,000 ₹6,000 Lowest | 4,000 ₹8,000 | 3,000 ₹6,000 Lowest | 3,500 ₹7,000 | 4,000 ₹8,000 | 8,000 ₹16,000 | 3,700 ₹7,400 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
7 Nov 2025, 6:00 pmClosed
Kameshwar Prasad, IDSE, EE
GE(West) Colaba, Mumbai - 400 005
REPAIR/REPLACEMENT OF LT CONTROL PANELS, CABLE CONTROL VALVE, PRIMMING TANKS AND VALVE AND CHLORINATION SYSTEM OF PUMPING STARTER/ PUMP HOUSE INCLUDING CONNECTED ITEMS UNDER GE (WEST) COLABA, MUMBAI
2025_MES_735675_1
8128/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE(West), Colaba
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (W) Colaba, Mumbai
₹90,000
Yes
25 Nov 2025
16 Oct 2025
10 Nov 2025
16 Oct 2025
7 Nov 2025
31 Oct 2025
Amount
Supplying, laying, testing & commissioning of LT under ground XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor 1100 volt grade 3.5 core x 120 sqmm laid in ducts fixed with saddle & clamps or passing through pipes complete with brass compression gland & proper lugs, nuts, bolts, washers completed including taking down/out old cable, complete all as specified and directed.
All as per item No. 1 above but 3.5 core x 95 sqmm.
All as per item No. 1 above but 3.5 core x 70 sqmm.
All as per item No. 1 above but 3.5 core x 50 sqmm.
Supplying, laying, testing in repair FR multistranded single core copper Three run conductor of size 6 Sqmm PVC sheathed un-armoured, 1100 volt grade, with RYB laid in floors/ducts or walls fixed with saddle & clamps or passing through pipes/flexible PVC pipe in concealed wiring complete with brass thimbles/lugs, nuts, bolts, washers, complete all as specified and directed.
Supplying, laying, testing in repair FR multistranded single core copper Three run conductor of size 10 Sqmm PVC sheathed un-armoured, 1100 volt grade, with RYB laid in floors/ducts or walls fixed with saddle & clamps or passing through pipes/flexible PVC pipe in concealed wiring complete with brass thimbles/lugs, nuts, bolts, washers, complete all as specified and directed.
Supplying, laying, testing in repair FR multistranded single core copper Three run conductor of size 16 Sqmm PVC sheathed un-armoured, 1100 volt grade, with RYB laid in floors/ducts or walls fixed with saddle & clamps or passing through pipes/flexible PVC pipe in concealed wiring complete with brass thimbles/lugs, nuts, bolts, washers, complete all as specified and directed.
S&F in repair 2000 ltr capacity rotational moulded polyethelene water storage tank cynlindrical vertical with closed top Tripled layered, white colour (inside & outside of tank), hoisted and fixed in position including float valve of suitable size, complete all as specified and directed.
S&F in repair 1000 ltr capacity rotational moulded polyethelene water storage tank cynlindrical vertical with closed top Tripled layered, white colour (inside & outside of tank), hoisted and fixed in position including float valve of suitable size, complete all as specified and directed.
S&F in repair 500 ltr capacity rotational moulded polyethelene water storage tank cynlindrical vertical with closed top Tripled layered, white colour (inside & outside of tank), hoisted and fixed in position including float valve of suitable size, complete all as specified and directed.
Taking up/down Old unserviceable GI pipe 15 mm bore with all fittings from trenches / ducts / walls / floors / ceilings, complete all as specified and directed.
Supply and fix in repair GI pipes medium grade 15mm bore with all fittings / GI bends laid in trenches, complete all as specified and directed.
Supply and fix sluice valve confirming to IS 14846 : 2000 CI body SS Spindle PN 1.6 ISI mark flanged ends for 80 mm bore pipe fixed with GI nuts, bolts, washers, rubber gaskets, etc including dismantling/taking out old unserviceable sluice valve, complete all as specified and directed.
All as per item No. 13 above but 100 mm dia bore.
All as per item No. 13 above but 150 mm dia bore.
Supply and fix butterfly valve confirming to IS 13095:1991, CI body, PN 1.6 ISI mark, flanged end for 80 mm bore pipe fixed with GI nut, bolts, washers, rubber gasket etc including dismantling/taking out old unserviceable valve, complete all as specified and directed.
Supply and fix non return valve, confirming to IS 5312:2004, CI body, for 150 mm dia bore pipe, ISI marked, flanged both ends, PN 1.6 rating, fixed with GI nuts, bolts, wahsers, rubber gasket etc including dismantling / taking out old unserviceable valve, complete all as specified and directed.
All as per item No. 17 above but 100 mm dia bore.
All as per item No. 17 above but 80 mm dia bore.
All as per item No. 17 above but 50 mm dia bore.
Supplying, laying, testing & commissioning of LT under ground XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor 1100 volt grade 3.5 core x 35 sqmm laid in ducts fixed with saddle & clamps or passing through pipes complete with brass compression gland & proper lugs, nuts, bolts, washers completed including taking down old cable, complete all as specified and directed.
M & L for Fully automatic star delta starter with single phase preventor for up to 20 HP pump complete including taking down old startar any make suitable for exting panel /Make, complete all as specified and directed.
M & L DOL starter with single phase preventer for monoblock pump set up to 5 HP capacity complete including taking down old cable any make suitable for exsting panel /make, complete all as specified and directed.
M& L for digital soft starter 70 HP, capacity complete any make suitable for exsting panel /make, including taking down old cable cat part CSX 055 41 in L & T or Equilent, complete all as specified and directed.
M & L for replacement of Earthing complete with GI earth plate electrode 60 cm X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.50 mtr below normal ground level connected to GI earth lead strip 32 x 6 mm dia by means of GI bolts, nuts, check nuts, washers made out of GI/steel, all as shown on electrical plate No3 of MESschedule part-I, earth lead strip connected to indicated position including concrete pit in PCC (1:3:6, C-1), Precast RCC cover slab 55 cm x 55 cm x 5 cm with reinforcement of 8 mm dia bar 100 mm c/c bothways including one handle made of 12 mm dia MS bar embedded in pre cast slab and 20 mm bore galvanised iron pipe"medium grade" for watering with GI funnel and wire mess including charcoal and salt in alternate layers of 15 cm including necessary excavation and earth work in any type of soil complete all as specified and as directed and testing on completion.
Material and labour for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 6mm dia galvanised iron or steel wire complete including taking down old, complete all as specified and directed.
Material and labour for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw, complete all as specified and directed
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed.
S&F Mild steel Joist, channel, angle or tee sections, fixed independently, without connecting plates etc, (cut to ordinary length of Fe 410-W-(Gde-E-250) quality-A, for making ladder of OHT tanks, complete all as specified and directed.
S&F Mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment including preparation of surfaces and applying one coat of primer and two coats of synthetic enamel paint, complete all as specified and directed.
Demolition of concrete of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
M&L for PCC type B-2 (1:2:4) using 40 mm graded stone aggregate in foundation, filling and mass concrete as in motor foundation, complete all as specified and directed.
Demolition of brick work or stone/boulder masonary built in cement mortar or cement lime mortar including all quoins, complete all as specified and directed.
M & L brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete at various locations, complete all as specified and directed.
M&L for renderting 15 mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces, complete all as specified and directed.
Supply and fixing Battery 12 V 180 AH model No XP 1800 including taking down old of exide or equivalent, complete all as specified and directed.
Supply only pad lock 50 mm dia with minimum double key, seven lever, made out of hardened brass and rust restistant internal components, complete all as specified and directed.
Supply and fixing Battery 12 V 130 AH model No XP 1300 of Exide including taking down old cable or equivalent, complete all as specified and directed.
S&F in repair pressure gauge 150 mm dia range 0-10 kg/Sqcm, Make : FIEBIG or equivalent Note : Rate quoted deemed to be included for providing adopter/Ferrule/check nut etc required for fixing of pressure gauge, complete all as specified and directed.
S&F in repair MCCB's 3 Phase (TP) 200A 50Hz, 36 KA fixed in existing panel board, complete all as specified and directed.
S&F in repair MCCB's 3 Phase (TP) 100A to 160 A 50Hz, 30 KA fixed in existing panel board, complete all as specified and directed.
S&F in repair MCCB's 3 Phase (TP) 63A 50Hz, 30 KA fixed in existing panel board, complete all as specified and directed.
S&F in repair MCCB's 3 Phase (FP) 200A 50Hz, 36 KA including suitable size sheet metal enclosure, complete all as specified and directed.
M & L testing Compact Motor Protection MM 10 relay for Medium & Large Size Motors Relay a microprocessor based Motor Protection Relay with 4 digits LED Display, Protections for Thermal Overload with Warning, Short Circuit, Under Current, Unbalance, Phase Loss, Phase Sequence Reversal, Earth Fault, Prolong Starting, Locked Rotor and Features of 4 Digit LED display, Measurement of RYB, Zero Sequence current and Thermal capacity, Separate LED’s for indication of Motor operational, Trip & Thermal OL/ pre-alarm, 2 nos ,1 no. Programmable Binary input for remote operation of C/O output contacts status, Programmable thermal OL time constant right from 1 sec to 40 sec,configured for operations of Trip Reset, Instant Tripping, Relay testing facility, Trip data recording Fault current or cause of last trip is displayed including suitable size current transformer for functioning motor pump, complete including taking down old, complete all as specified and directed by Engineer in charge. Make - L & T cat part no MM10240E005 / Havells / Indo Asian
Supply and fixing in repair LED indicator suitable motor panel (RYB) type, complete all as specified and directed.
Supply and fixing in repair digital Ampmeter 0 to 100 Amps suitable motor panel (RYB) type, complete all as specified and directed.
S&F in repair Thermal over load relay ML type 14-32 A, complete all as specified and directed.
S&F in repair Thermal over load relay MN type 30-50 A, complete all as specified and directed.
Supply and fixing in repair Voltmeter/ Ampmeter digital type of showing reading 0 to 500 Amps/volts suitable motor panel (RYB) type, complete all as specified and directed.
Supply and fixing in repair Copper busbar of capacity 150/240 amp for each phase & neutral suitable size insulator, nut, bolts motor panel (RYB) type, complete all as specified and directed.
M & L for cleaning of fire chamber / Valve Chamber in area and remove all debris / plastic etc from chamber and throughout outside of army area and painting of chamber plate red / Black colour including transport carrying debris, complete all as specified and directed.
S&F in repair main contactor ML 4, 3 Pole of Make L&T or equivalent, complete all as specified and directed.
All as per items No. 55 but ML 3, 3 Pole of Make L&T or equivalent, complete all as specified and directed.
All as per items No. 55 but MNX 70, 3 Pole of Make L&T (Cat Part No.ST19002) or equivalent, complete all as specified and directed.
Supply, fixing and testing altoch dozing system model No ADS-PRO including branch connection with all connecting material, Suitable size pipes, electric connection etc complete including taking down old, complete all as specified and directed.
Supply only chlorine refill casul Stequa 411 AE Refil including taking down old, complete all as specified and directed.
M & L in repair for 4 mm thick non asbestos fibre cement building boards fixed or laid / inserted to timber / GI/ Aluminium frame work with screws as in ceiling, complete all as specified and directed.
S & F in repair Aliminium snap Grid Frame work for false ceiling incl 6mm dia GI hanger (up to 1200 mm length ) adjusting level fixed to roof slab /truss/purlins/rafters @ 12m C/C, complete all as specified and directed.
Supply only Alum Crystal required for disinfection/ treatment of water, complete all as specified and directed.
Supply only bleaching powder required for disinfection/ treatment of water, complete all as specified and directed.
Supply only TCC 90 required for disinfection/ treatment of water, complete all as specified and directed.
Supply only Copper sulphate required for disinfection/ treatment of water, complete all as specified and directed.
Supply only Soda ash required for disinfection/ treatment of water, complete all as specified and directed.
Supply only Calcium based high strength chlorine granuals to maintain Chlorine 1 ppm, complete all as specified and directed.
SUNRISE CONSTRUCTION CO (BID ID -3468098)
NOEL ENGINEERS (BID ID -3465231)
HINDUSTAN BUILDERS (BID ID -3472860)
Rama Construction Co (BID ID -3469406)
Minal Engineers (BID ID -3467621)
SHREE SHIV SHANKER ENTERPRISE (BID ID -3474158)
N.S.ENTERPRISES (BID ID -3469300)
GANGAJAL (BID ID -3467355)
Sagar Electricals (BID ID -3468003)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
BOQ_823792.xls
BOQ • 1.32 MB
8128TenderPages.pdf
Tender Documents • 1.61 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .