Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹3.7 L+₹51,612.37 (16.0%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹4.0 L+₹76,865.55 (23.8%)Rejected-AOC AT JHARKHAND 15 NO KEDLA DIST RAMGARH JHARKHAND | RAMGARH | JHARKHAND | 825101 | L3 | Rejected-AOC L3 | |
| 4 | L4₹4.1 L+₹85,029.59 (26.3%)Rejected-AOC HOUSE NO 345 SHREE RAM ELECTRICALS SONIPAT ROAD LAWANSPUR SONIPAT HARYANA 131021 | SONIPAT | HARYANA | 131021 | L4 | Rejected-AOC L4 | |
| 5 | L5₹4.7 L+₹1.4 L (43.9%)Rejected-AOC MIG 1 22 R S S NAGAR KORBA CG 495677 | KORBA | CHHATTISGARH | 495677 | L5 | Rejected-AOC L5 |
Tender Value
₹4.8 L
EMD Value
₹6,100
Closing Date
21 Sept 2023, 5:30 pmClosed
SO EnM GNH
Office of SO EnM GNH
Repairing and renovation of power arrangement in maternity block and maternity OT block of GNH
2023_CCL_288809_1
CMS(I/C)/GNH/EnM/ET/23-24/09
Open Tender
Electrical and Maintenance Works
Item Rate
45 days
GNH
Please refer Tender documents.
2 documents required · 2 mandatory
₹6,100
20 Feb 2024
14 Sept 2023
22 Sept 2023
14 Sept 2023
21 Sept 2023
14 Sept 2023
14 Sept 2023 - 18 Sept 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 10 sq. mm + 1 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 7 x 1.5 sq. mm
Supplying and fixing suitable size GI box with modular plate and cover in FRLSont on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 Amps Switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. bell push ISI marked
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 Amps Switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 Amps 3 pin Socket
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16Amps 6 pin Socket
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 6 Module (200mmX75mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 8 Module (125mmX125mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 12 Module (200mmX150mm)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supply & fixing of LED Lights 12 Watt LED Recessed Luminaire
Supplying and fixing of Bed Side call bell indicator board with bell and LED indicator including fixing and matching connections to bed side bells serially (suitable for 12 Nos. call bells)
Total impact of GST for the purpose of CTC
M/S B.N. PANDEY
M S VIJAY CONTRACTOR SUPPLIER
SHREE RAM ELECTRICALS
AMAN CONSTRUCTION
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .