Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 LAdmitted-Finance | ₹6.5 L | L1 | Admitted-Finance |
| 2 | L2₹6.6 L+₹10,695.52 (1.64%)Admitted-Finance | ₹6.6 L+₹10,695.52 (1.64%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | STANDARD CAPACITORS L1 | bhawani electrical system L2 |
|---|---|---|---|---|---|
| 1.01 | REPAIR & RENOVATIOIN OF 125 KVAR APFC PANEL 2 NOS Dismantling of defective capacitor units from the APFC panel after suitably discharging the left-over charge on capacitors to ensure safety of the working persons along with dismantling of Capacitors, APFC relay, indications lights, meters, A/M switches including dismantling of terminations and existing hardware and rusted parts and various other items requiring change in the panel as required at site. | 2 | Jobs | 23,000 ₹27,140 Lowest | 25,000 ₹29,500 |
| 1.02 | Replacement of defective Super Heavy Duty Capacitor units of various capacities with new capacitor units, rated at 440 V, 3 phase, 50 Hz system complete with terminal cover, cable end entry, mounting structure and hardware etc. -Make Standard | 75 | kvar | 37,350 ₹44,073 Lowest | 37,500 ₹44,250 |
| 1.03 | Banking of capacitors of various capacities with multistrand copper wires & lugs /aluminium bus bars and mounting arrangement for parallel connection to form suitable rating capacitor bank. | 75 | kvar | 6,375 ₹7,522.5 Lowest | 11,250 ₹13,275 |
| 1.04 | Replacement of defective APFC relay, with new microprocessor based APFC Relay having digital display of power factor and other parameters to sense power factor through control CT and give phased impulses to contactor coils for switching ON-OFF required number of capacitors as per requirement to achieve target power factor. Make Standard | 2 | Nos | 46,736 ₹55,148.48 Lowest | 47,000 ₹55,460 |
| 1.05 | Programming of APFC relay for target power factor including setting of various parameters and keeping updated indications of the efficiency of electrical power usage, and improving it for reducing the power losses and avoid penalties from utility companies. Replacement of defective capacitor duty contactors suitable for 25 KVAr capacitor with new capacitor duty contactor. Make Standard/EPCOS Replacement of defective capacitor duty contactors suitable for 15 KVAr capacitor with new capacitor duty contactor. Make Standard/EPCOS | 2 | Jobs | 18,000 ₹21,240 Lowest | 19,000 ₹22,420 |
| 1.06 | Supply of Push buttons for replacement of defective push buttons to switch ON and OFF capacitor banks in manual mode- make FTC/Standard/L&T Replacement of defective triple pole MCB of 63 A capacity with new MCB for operation and safety of individual capacitor bank - make L&T/EPCOS/Standard Replacement of defective triple pole MCB of 32 A capacity with new MCB for operation and safety of individual capacitor bank - make L&T/EPCOS/Standard | 2 | Nos | 2,300 ₹2,714 Lowest | 2,400 ₹2,832 |
| 1.07 | Replacement of defective/burnt out LED indication lights of various colours with new indication lights, make -Standard/L&T | 15 | Nos | 2,175 ₹2,566.5 Lowest | 2,250 ₹2,655 |
| 1.08 | Power wiring with 10 sq. mm multistrand copper wires for connection between capacitors and bus bar using copper lugs and necessary hardware etc. as required at site. | 2 | Jobs | 18,000 ₹21,240 | 15,000 ₹17,700 Lowest |
| 1.09 | Installation of all above components in the existing capacitor banks with suitable fabrication work to accommodate new items in the existing enclosure / structure for alignment of components and ease of termination, complete with hardware on the mounting structure and termination of existing cables with lugs, tapes etc. complete with earthing of the capacitor banks, touching the rusted parts of the panel structure with paint for protection from moisture etc. as required at site | 2 | Jobs | 29,000 ₹34,220 | 25,000 ₹29,500 Lowest |
| 1.10 | Servicing of APFC panels including complete dusting of the panel, cleaning of contact points, Decarbonising of joints, alignment of doors, checking of all nuts & bolts, control circuit and power circuit wiring dressing and renovation of control and power terminations etc. as required at site | 2 | Jobs | 35,000 ₹41,300 Lowest | 36,000 ₹42,480 |
Tender Value
Refer Docs
EMD Value
₹13,400
Closing Date
9 Sept 2026, 3:00 pmClosed
Executive Engineer (EM) M-13
Chitra Vihar BP Station Laxmi Nagar Delhi-110092
Repairing of power factor of standard make capacitor panel at Surajmal Vihar BPS
2026_DJB_297971_8
NIT No-06 EE (EM) M-13/ (26-27)
Open Tender
Electrical Works
Works
30 days
Chitra Vihar BP Station Laxmi Nagar Delhi-110092
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
A/c.5044833980
₹13,400
17 Sept 2026
4 Sept 2026
9 Sept 2026
4 Sept 2026
9 Sept 2026
4 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | REPAIR & RENOVATIOIN OF 125 KVAR APFC PANEL 2 NOS Dismantling of defective capacitor units from the APFC panel after suitably discharging the left-over charge on capacitors to ensure safety of the working persons along with dismantling of Capacitors, APFC relay, indications lights, meters, A/M switches including dismantling of terminations and existing hardware and rusted parts and various other items requiring change in the panel as required at site. | 2 | Jobs | 80 | ₹160 |
| 1.02 | Replacement of defective Super Heavy Duty Capacitor units of various capacities with new capacitor units, rated at 440 V, 3 phase, 50 Hz system complete with terminal cover, cable end entry, mounting structure and hardware etc. -Make Standard | 75 | kvar | 80 | ₹6,000 |
| 1.03 | Banking of capacitors of various capacities with multistrand copper wires & lugs /aluminium bus bars and mounting arrangement for parallel connection to form suitable rating capacitor bank. | 75 | kvar | 80 | ₹6,000 |
| 1.04 | Replacement of defective APFC relay, with new microprocessor based APFC Relay having digital display of power factor and other parameters to sense power factor through control CT and give phased impulses to contactor coils for switching ON-OFF required number of capacitors as per requirement to achieve target power factor. Make Standard | 2 | Nos | 80 | ₹160 |
| 1.05 | Programming of APFC relay for target power factor including setting of various parameters and keeping updated indications of the efficiency of electrical power usage, and improving it for reducing the power losses and avoid penalties from utility companies. Replacement of defective capacitor duty contactors suitable for 25 KVAr capacitor with new capacitor duty contactor. Make Standard/EPCOS Replacement of defective capacitor duty contactors suitable for 15 KVAr capacitor with new capacitor duty contactor. Make Standard/EPCOS | 2 | Jobs | 80 | ₹160 |
| 1.06 | Supply of Push buttons for replacement of defective push buttons to switch ON and OFF capacitor banks in manual mode- make FTC/Standard/L&T Replacement of defective triple pole MCB of 63 A capacity with new MCB for operation and safety of individual capacitor bank - make L&T/EPCOS/Standard Replacement of defective triple pole MCB of 32 A capacity with new MCB for operation and safety of individual capacitor bank - make L&T/EPCOS/Standard | 2 | Nos | 80 | ₹160 |
| 1.07 | Replacement of defective/burnt out LED indication lights of various colours with new indication lights, make -Standard/L&T | 15 | Nos | 80 | ₹1,200 |
| 1.08 | Power wiring with 10 sq. mm multistrand copper wires for connection between capacitors and bus bar using copper lugs and necessary hardware etc. as required at site. | 2 | Jobs | 80 | ₹160 |
| 1.09 | Installation of all above components in the existing capacitor banks with suitable fabrication work to accommodate new items in the existing enclosure / structure for alignment of components and ease of termination, complete with hardware on the mounting structure and termination of existing cables with lugs, tapes etc. complete with earthing of the capacitor banks, touching the rusted parts of the panel structure with paint for protection from moisture etc. as required at site | 2 | Jobs | 80 | ₹160 |
| 1.1 | Servicing of APFC panels including complete dusting of the panel, cleaning of contact points, Decarbonising of joints, alignment of doors, checking of all nuts & bolts, control circuit and power circuit wiring dressing and renovation of control and power terminations etc. as required at site | 2 | Jobs | 80 | ₹160 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.81 MB
BOQ_397192.xls
BOQ • 0.27 MB
C13.pdf
PDF • 0.47 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .