Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.4 LAccepted-AOC | 1 | Accepted-AOC lowest agency | |
| 2 | 2₹8.7 L+₹2.3 L (35.5%)Rejected-AOC | 2 | Rejected-AOC higher rate |
Tender Value
₹9.3 L
EMD Value
₹18,540
Closing Date
30 Jul 2020, 3:00 pmClosed
EE PHED Tosham
EE PHED Tosham
Providing sewerage scheme Bawani Khera
2020_HRY_136849_1
No. 7501-7557 dt. 21/07/2020
Open Tender
Civil Works
Works
Bawani Khera
Providing sewerage scheme Bawani Khera
2 documents required · 2 mandatory
₹1,000
EE PHED TOSHAM
₹18,540
Yes
19 Aug 2020
22 Jul 2020
30 Jul 2020
22 Jul 2020
30 Jul 2020
22 Jul 2020
22 Jul 2020 - 30 Jul 2020
Amount
Supply, Installation, testing and commissioning Electromagnetic Flow Meter INLET Model No: 151 MFM WR 4 2 2 0 N500 3D 1 2 6 1 4 2 8P W:Accuracy Class & Display:± 0.5% of measured flow; 2 Line LCD R:Indicator Converter Type: Remote, field mounted 4:Power Supply: Universal Power Supply 85 to 265VAC@45 to 65 Hz 2:Output:4 to 20mA 2:Communication Interface: RS 485 (MODBUS RTU) 0:Data Logger: Not Applicable N:Cable Entry:1/2"NPT 0300:Sensor Size (mm):18” : 450 mm 3:Pressure Rating(Kg/cm2):16 Kg/cm2 D:Design of the Measuring Sensor: Flanged-DIN 1:Flange Material: CS 2:Sensor Lining: PTFE 6:Electrode Material:SS316 1:Earthing ring: None. With built-in earthing electrode. 4:Measuring Tube:SS304 2:Coil Housing: CS 8:Protection Class for Sensor:IP68 P:Approval :Non Hazardous area Cable L=20 mtrs (As per Analysis) (Make – Forbes Marshall / ABB / Schumburger / Endress Hauser / YBL Yokogawa / Magnetrol/ SBEM/Unitech Including two year operation and maintenance
Supply, Installation, testing and commissioning Electromagnetic Flow Meter OUTLET Model No: 151 MFM WR 4 2 2 0 N500 3D 1 2 6 1 4 2 8P W:Accuracy Class & Display:± 0.5% of measured flow; 2 Line LCD R:Indicator Converter Type: Remote, field mounted 4:Power Supply: Universal Power Supply 85 to 265VAC@45 to 65 Hz 2:Output:4 to 20mA 2:Communication Interface: RS 485 (MODBUS RTU) 0:Data Logger: Not Applicable N:Cable Entry:1/2"NPT 0300:Sensor Size (mm):12” : 300 mm 3:Pressure Rating(Kg/cm2):16 Kg/cm`12 D:Design of the Measuring Sensor: Flanged-DIN 1:Flange Material: CS 2:Sensor Lining: PTFE 6:Electrode Material:SS316 1:Earthing ring: None. With built-in earthing electrode. 4:Measuring Tube:SS304 2:Coil Housing: CS 8:Protection Class for Sensor:IP68 P:Approval :Non Hazardous area Cable L=20 mtrs (As per Analysis) (Make – Forbes Marshall / ABB / Schumburger / Endress Hauser / YBL Yokogawa / Magnetrol/ SBEM/Unitech Including two year operation and maintenance
Supply, Fixing, testing & commissioning of Remote Terminal Unit with power analyzer having inbuilt GSM / GPRS modem. iRTU configuration is 6 Digital inputs, 2 Digital Outputs & 2 Anolog Inputs. iRTU nstallation inside a panel having isolation transformer. RTU suitable for multi parameter for transferring data to MCS complete in all respect. Make – Forbes Marshall / ABB / Schumburger / Endress Hauser / YBL Yokogawa / Magnetrol SBEM/Unitech/Cimcon Including two year operation and maintenance
Installation & accessories like Cabling as per site requirements, Panel Box etc.. Commissioning Charges of Flow Meter, Customization and programming of flow meter, Configurations as per site requirements & making connection with the existing SCADA software, Head Office, HSPCB & CPCB to the satisfaction of Engineering In‐charge, Including two year operation and maintenance
Ravinder sangwan
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .