| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹53,421.70Accepted-AOC 2 ZUBER COMPLEX 4 AERODROME CIRCLE KOTA 324007 | KOTA | KOTA | RAJASTHAN | 324007 | L-1 | Accepted-AOC L1 | |
| 2 | L-1₹55,356.38Accepted-AOC F 236 A INDRAPRASTHA INDUSTRIAL AREA ROAD NO 5 KOTA KOTA RAJASTHAN 324005 | KOTA | RAJASTHAN | 324005 | L-1 | Accepted-AOC L1 | |
| 3 | L-1₹1.6 LAccepted-AOC 22 BEHIND MODERN PETROL PUMP BEHIND MODERN PETROL PUMP JHALAWAR ROAD KOTA KOTA RAJASTHAN 324007 | KOTA | RAJASTHAN | 324007 | L-1 | Accepted-AOC L1 | |
| 4 | L-1₹3.3 LAccepted-AOC | L-1 | Accepted-AOC L1 | |
| 5 | L-1₹3.8 LAccepted-AOC | L-1 | Accepted-AOC L1 |
Tender Value
₹24.3 L
Closing Date
27 Aug 2021, 11:00 amClosed
CE(CTPP)
ADM Building, Motipura Chowki, Chhabra
Procurement of MCB, MCCB, Fuse Link, SFU and RCCB for CTPP, Chhabra
2021_RRVUN_235810_1
1109/2021-22(MM)
Open Tender
Miscellaneous Goods
Item Wise
120 days
CTPP, RVUNL, Chhabra
As per uploaded our tender documents
2 documents required · 2 mandatory
₹590
Yes
Account Officer, CTPP, RVUNL, Chhabra
Exempted
23 Apr 2022
6 Aug 2021
27 Aug 2021
6 Aug 2021
27 Aug 2021
6 Aug 2021
MCB suitable for DIN rail type 2 Pole, 240VAC, breaking capacity= 10 kA, B curve, Ui ≥ 660 V, magnetic release setting = (5-10)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
6A MCB suitable for DIN rail type 2 Pole, 240VAC, breaking capacity= 10 kA, B curve, Ui ≥ 660 V, magnetic release setting = (5-10)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
MCB suitable for DIN rail type 2 Pole, 415VAC, breaking capacity= 10 kA, B curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
63 A MCB suitable for DIN rail type 2 Pole, 415VAC, breaking capacity= 10 kA, B curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
MCB suitable for DIN rail type 3 Pole, 415VAC, breaking capacity= 10 kA, B curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 10000 operations, IP20, confirming to IS/IEC60898-1-2002
4A MCB suitable for DIN rail type 3 Pole, 415VAC, breaking capacity= 10 kA, B curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 10000 operations, IP20, confirming to IS/IEC60898-1-2002
6A MCB suitable for DIN rail type 3 Pole, 415VAC, breaking capacity= 10 kA, B curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 10000 operations, IP20, confirming to IS/IEC60898-1-2002
10A MCB suitable for DIN rail type 3 Pole, 415VAC, breaking capacity= 10 kA, B curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 10000 operations, IP20, confirming to IS/IEC60898-1-2002
16A MCB suitable for DIN rail type 3 Pole, 415VAC, breaking capacity= 10 kA, B curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 10000 operations, IP20, confirming to IS/IEC60898-1-2002
20A MCB suitable for DIN rail type 3 Pole, 415VAC, breaking capacity= 10 kA, B curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 10000 operations, IP20, confirming to IS/IEC60898-1-2002
32A MCB suitable for DIN rail type 3 Pole, 415VAC, breaking capacity= 10 kA, B curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 10000 operations, IP20, confirming to IS/IEC60898-1-2002
63A MCB suitable for DIN rail type 3 Pole, 415VAC, breaking capacity= 10 kA, B curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 10000 operations, IP20, confirming to IS/IEC60898-1-2002
MCB suitable for DIN rail type 4 Pole, 415VAC, breaking capacity= 10 kA, B curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
6A MCB suitable for DIN rail type 4 Pole, 415VAC, breaking capacity= 10 kA, B curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
16A MCB suitable for DIN rail type 4 Pole, 415VAC, breaking capacity= 10 kA, B curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
32A MCB suitable for DIN rail type 4 Pole, 415VAC, breaking capacity= 10 kA, B curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
63A MCB suitable for DIN rail type 4 Pole, 415VAC, breaking capacity= 10 kA, B curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
MCB suitable for DIN rail type 1 Pole, 240 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (5-10)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
0.5 A MCB suitable for DIN rail type 1 Pole, 240 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (5-10)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
1A MCB suitable for DIN rail type 1 Pole, 240 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (5-10)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
2A MCB suitable for DIN rail type 1 Pole, 240 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (5-10)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
4A MCB suitable for DIN rail type 1 Pole, 240 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (5-10)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
6A MCB suitable for DIN rail type 1 Pole, 240 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (5-10)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
10A MCB suitable for DIN rail type 1 Pole, 240 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (5-10)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
16A MCB suitable for DIN rail type 1 Pole, 240 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (5-10)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
20A MCB suitable for DIN rail type 1 Pole, 240 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (5-10)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
25A MCB suitable for DIN rail type 1 Pole, 240 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (5-10)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
32A MCB suitable for DIN rail type 1 Pole, 240 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (5-10)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
MCB suitable for DIN rail type 2 Pole, 240 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (5-10)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
1A MCB suitable for DIN rail type 2 Pole, 240 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (5-10)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
2A MCB suitable for DIN rail type 2 Pole, 240 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (5-10)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
4A MCB suitable for DIN rail type 2 Pole, 240 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (5-10)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
6A MCB suitable for DIN rail type 2 Pole, 240 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (5-10)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
10A MCB suitable for DIN rail type 2 Pole, 240 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (5-10)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
16A MCB suitable for DIN rail type 2 Pole, 240 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (5-10)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
20A MCB suitable for DIN rail type 2 Pole, 240 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (5-10)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
25A MCB suitable for DIN rail type 2 Pole, 240 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (5-10)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
32A MCB suitable for DIN rail type 2 Pole, 240 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (5-10)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
MCB suitable for DIN rail type2 Pole, 415 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
6A MCB suitable for DIN rail type2 Pole, 415 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
16A MCB suitable for DIN rail type2 Pole, 415 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
MCB suitable for DIN rail type 2 Pole, 415 VAC, breaking capacity= 10 kA, C curve
4A MCB suitable for DIN rail type 2 Pole, 415 VAC, breaking capacity= 10 kA, C curve
6A MCB suitable for DIN rail type 2 Pole, 415 VAC, breaking capacity= 10 kA, C curve
16A MCB suitable for DIN rail type 2 Pole, 415 VAC, breaking capacity= 10 kA, C curve
MCB suitable for DIN rail type 3 Pole, 415 VAC, breaking capacity= 10 kA, C curve
3A MCB suitable for DIN rail type 3 Pole, 415 VAC, breaking capacity= 10 kA, C curve
4A MCB suitable for DIN rail type 3 Pole, 415 VAC, breaking capacity= 10 kA, C curve
6A MCB suitable for DIN rail type 3 Pole, 415 VAC, breaking capacity= 10 kA, C curve
10A MCB suitable for DIN rail type 3 Pole, 415 VAC, breaking capacity= 10 kA, C curve
20A MCB suitable for DIN rail type 3 Pole, 415 VAC, breaking capacity= 10 kA, C curve
63A MCB suitable for DIN rail type 3 Pole, 415 VAC, breaking capacity= 10 kA, C curve
MCB suitable for DIN rail type 4 Pole, 415 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
3A MCB suitable for DIN rail type 4 Pole, 415 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
4A MCB suitable for DIN rail type 4 Pole, 415 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
10A MCB suitable for DIN rail type 4 Pole, 415 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
16A MCB suitable for DIN rail type 4 Pole, 415 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
32A MCB suitable for DIN rail type 4 Pole, 415 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
50A MCB suitable for DIN rail type 4 Pole, 415 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
63A MCB suitable for DIN rail type 4 Pole, 415 VAC, breaking capacity= 10 kA, C curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
MCB suitable for DIN rail type 4 Pole, 415 VAC, breaking capacity= 10 kA, D curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
4A MCB suitable for DIN rail type 4 Pole, 415 VAC, breaking capacity= 10 kA, D curve, Ui ≥ 660 V, magnetic release setting = (3-5)In, Uimp = 4 kV, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-1-2002
MCB-DC suitable for DIN rail type 2 Pole, 220 VDC, breaking capacity= 10 kA, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-2-2003
2A MCB-DC suitable for DIN rail type 2 Pole, 220 VDC, breaking capacity= 10 kA, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-2-2003
4A MCB-DC suitable for DIN rail type 2 Pole, 220 VDC, breaking capacity= 10 kA, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-2-2003
6A MCB-DC suitable for DIN rail type 2 Pole, 220 VDC, breaking capacity= 10 kA, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-2-2003
10A MCB-DC suitable for DIN rail type 2 Pole, 220 VDC, breaking capacity= 10 kA, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-2-2003
16A MCB-DC suitable for DIN rail type 2 Pole, 220 VDC, breaking capacity= 10 kA, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-2-2003
25A MCB-DC suitable for DIN rail type 2 Pole, 220 VDC, breaking capacity= 10 kA, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-2-2003
MCB-DC suitable for DIN rail type 2 Pole, 250 VDC, breaking capacity= 10 kA, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-2-2003
20A MCB-DC suitable for DIN rail type 2 Pole, 250 VDC, breaking capacity= 10 kA, electrical/mechanical life > 30000 operations, IP20, confirming to IS/IEC60898-2-2003
MCB Rating- 2 Pole, 1A, 230VAC
MCB Rating- 2 Pole, 4A, 415VAC
MCB Rating- 2 Pole, 6A, 415VAC
MCB Rating- 2 Pole, 10A, 415VAC
MCB Rating- 2 Pole, 16A, 415VAC
MCB Rating- 2 Pole, 32A, 415VAC
MCB Rating- 2 Pole, 50A, 415VAC
Fuse Base and Fuse
15-32A, CLOSED TYPE FUSEBASE,415V,ESSEN
6A FUSE LINK,415V,STAGTAG,HRC
10A FUSE LINK,415V,STAGTAG,HRC
16A FUSE LINK,415V,STAGTAG,HRC
20A FUSE LINK,415V,STAGTAG,HRC
35A FUSE LINK,415V,STAGTAG,HRC
MCCB three pole, thermal magnetic trip, Ue = 415 VAC, 50 Hz, Icu = 25 kA, Ui = 750 V, Uimp = 8 kV, Ics = 100%Icu, adjustable overload and adjustable short circuit setting
32A MCCB three pole, thermal magnetic trip, Ue = 415 VAC, 50 Hz, Icu = 25 kA, Ui = 750 V, Uimp = 8 kV, Ics = 100%Icu, adjustable overload and adjustable short circuit setting
40A MCCB three pole, thermal magnetic trip, Ue = 415 VAC, 50 Hz, Icu = 25 kA, Ui = 750 V, Uimp = 8 kV, Ics = 100%Icu, adjustable overload and adjustable short circuit setting
63A MCCB three pole, thermal magnetic trip, Ue = 415 VAC, 50 Hz, Icu = 25 kA, Ui = 750 V, Uimp = 8 kV, Ics = 100%Icu, adjustable overload and adjustable short circuit setting
100A MCCB three pole, thermal magnetic trip, Ue = 415 VAC, 50 Hz, Icu = 25 kA, Ui = 750 V, Uimp = 8 kV, Ics = 100%Icu, adjustable overload and adjustable short circuit setting
125A MCCB three pole, thermal magnetic trip, Ue = 415 VAC, 50 Hz, Icu = 25 kA, Ui = 750 V, Uimp = 8 kV, Ics = 100%Icu, adjustable overload and adjustable short circuit setting
MCCB four pole, thermal magnetic trip, Ue = 415 VAC, 50 Hz, Icu = 25 kA, Ui = 750 V, Uimp = 8 kV, Ics = 100%Icu, adjustable overload and adjustable short circuit setting
TP&N 415 VAC-23A front handle operated switch disconnector fuse unit cubical type, without metallic enclosure, confirming to IS: 13947 P-III in existing panel (w/o HBC fuses) of following rating (PWD BSR (Elect.)-2013 code:E100400, group-1)
63A rating (E100402, Group-1)
100A rating (E100403, Group-1)
125A rating (E100403, Group-1)
TP&N 415 V side handle operated double break switch unit in sheet steel enclosure, confirming to IS: 13947 P-III and IS:4064 (w/o HBC fuses) including making connections with suitable lugs, testing etc. as required (PWD BSR (Elect.)-2013 code:E100300, group-1)
63A rating (E100301, Group-1)
100A rating (E100302, Group-1)
RCCB suitable for DIN rail type 2 Pole, Un = 240 VAC, 50 Hz, IP40, Residual operating current IΔn = 30 mA, Instantaneous tripping time at IΔn < 40 ms, Im = IΔm > 500 A, Inc = IΔc ≥ 6 kA, Insulation voltage > 660 VDC, Type A, power supply = top/bottom, Terminal capacity min/max = 1.5/25 mm², with test button, Confirming to IS 12640-1:2008
40 A RCCB suitable for DIN rail type 2 Pole, Un = 240 VAC, 50 Hz, IP40, Residual operating current IΔn = 30 mA, Instantaneous tripping time at IΔn < 40 ms, Im = IΔm > 500 A, Inc = IΔc ≥ 6 kA, Insulation voltage > 660 VDC, Type A, power supply = top/bottom, Terminal capacity min/max = 1.5/25 mm², with test button, Confirming to IS 12640-1:2008
63 A RCCB suitable for DIN rail type 2 Pole, Un = 240 VAC, 50 Hz, IP40, Residual operating current IΔn = 30 mA, Instantaneous tripping time at IΔn < 40 ms, Im = IΔm > 500 A, Inc = IΔc ≥ 6 kA, Insulation voltage > 660 VDC, Type A, power supply = top/bottom, Terminal capacity min/max = 1.5/25 mm², with test button, Confirming to IS 12640-1:2008
RCCB suitable for DIN rail type 4 Pole, Un = 415 VAC, 50 Hz, IP40, Residual operating current IΔn = 30 mA, Instantaneous tripping time at IΔn < 40 ms, Im = IΔm > 500 A, Inc = IΔc ≥ 6 kA, Insulation voltage > 660 VDC, Type A, power supply = top/bottom, Terminal capacity min/max = 1.5/25 mm², with test button, Confirming to IS 12640-1:2008
32 A RCCB suitable for DIN rail type 4 Pole, Un = 415 VAC, 50 Hz, IP40, Residual operating current IΔn = 30 mA, Instantaneous tripping time at IΔn < 40 ms, Im = IΔm > 500 A, Inc = IΔc ≥ 6 kA, Insulation voltage > 660 VDC, Type A, power supply = top/bottom, Terminal capacity min/max = 1.5/25 mm², with test button, Confirming to IS 12640-1:2008
63 A RCCB suitable for DIN rail type 4 Pole, Un = 415 VAC, 50 Hz, IP40, Residual operating current IΔn = 30 mA, Instantaneous tripping time at IΔn < 40 ms, Im = IΔm > 500 A, Inc = IΔc ≥ 6 kA, Insulation voltage > 660 VDC, Type A, power supply = top/bottom, Terminal capacity min/max = 1.5/25 mm², with test button, Confirming to IS 12640-1:2008
SAURABH UDYOG
sourabh engineers consultant
NEW AGE TRADE CENTRE
ABHISHEK ENTERPRISES
Power Controls
NEW AGE TRADE CENTRE
Power Controls
ABHISHEK ENTERPRISES
SAURABH UDYOG
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .