| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.5 LAccepted-Finance | ₹11.5 L | L1 | Accepted-Finance Accepted |
| 2 | L2₹11.9 LAccepted-Finance A 6 MANDAWALI UNCHEPAR DELHI 110092 | SHAHDARA | DELHI | 110092 | ₹11.9 L | L2 | Accepted-Finance Accepted |
| 3 | L3₹12.5 LAccepted-Finance | ₹12.5 L | L3 | Accepted-Finance Accepted |
| 4 | L4₹14.2 LAccepted-Finance | ₹14.2 L | L4 | Accepted-Finance Accepted |
| 5 | L5₹17.7 LAccepted-Finance IST FLOOR PLOT NO 2 BUILDING NO FLAT NO UNIT NO 165 VARDHMAN CROWN MALL SECTOR 19 DWARKA NEW DELHI 110075 | SOUTH WEST | DELHI | 110075 | ₹17.7 L | L5 | Accepted-Finance Accepted |
Tender Value
₹19.8 L
EMD Value
₹39,648
Closing Date
9 Jan 2026, 3:00 pmClosed
Executive Engineer (E)
O/o EE (E), HPED, PWD, Yamuna Western Bank, Lok Nayak Setu, ITO, New Delhi-02
SITC of Retrofit Emission Control Device in the existing 750KVA capacity DG Set installed at Lal Bahadur Shastri Hospital Khichripur Delhi
2025_PWD_282681_2
11/EE(E)/HPED/PWD/2025-26
Open Tender
Electrical Works
Percentage
30 days
Lal Bahadur Shastri Hospital, Khichripur
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹39,648
Yes
30 May 2026
29 Dec 2025
9 Jan 2026
29 Dec 2025
9 Jan 2026
29 Dec 2025
Supplying, Installation, Testing & Commissioning of Retrofit Emission Control Device in the existing 750 KVA DG sets to reduce Particulate Matter (PM), Hydrocarbon and Carbon Monoxide emission by at least 70%. Adhering to this, Device should be 'Type Approved' as per the System and Procedure of Central Pollution Control Board for Emission Compliance Testing of Retro-fit Emission Control Devices (RECD) For Diesel Power Generating Set Engines, Dated 01/02/2022, wide Pollution Control Series PCLS/12/2021-22. Adhering to this, RECD should be 'Type Approved' for equivalent KVA rating from any one of the four Central Pollution Control Board, Govt. of India,recognized/approved test agencies/laboratories. The RECD device should be equipped with a remote data Monitoring system certified by ICAT/ARAI providing essential information recorded at every 15 minutes, including but not limited to : i. Energy consumption ii. Running hours iii.Warnings related to ECD diagnosis for the following conditions: 1. Complete loss of particulate capture function. 2. Removal of the ECD system. 3. Failure of the ECD system. 4. Detection of exhaust bypass, temporary or permanent, as part of field/operating, tempering. .RECD should not accumulate any soot, during the emission control process/NO addition device requirement for the disposal of soot.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 7.20 MB
Revisednit.pdf
Tender Documents • 7.06 MB
BOQ_375245.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].