| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAccepted-AOC 32 H 8 3 MAHENDRA ROY LANE TOPSIA KOLKATA 700046 | KOLKATA | KOLKATA | WEST BENGAL | 700046 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹4.9 L+₹13,175 (2.78%)Rejected-Finance 210 14 R B AVENUE KOL 29 | KOLKATA | KOLKATA | WEST BENGAL | 700029 | L2 | Rejected-Finance High rate | |
| 3 | L3₹5.8 L+₹1.1 L (22.3%)Rejected-Finance 24C GOABAGAN LANE KOLKATA 700 006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L3 | Rejected-Finance high rate |
Tender Value
Refer Docs
EMD Value
₹11,861
Closing Date
23 Oct 2024, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Executive Engineer,CKHED,PWDte
Office of The Executive Engineer,CKHED, P-12, CIT Road.
Repairing and Renovation of Seminar room and dressing room for Plastic and Reconstructive Surgery department at 1st floor of Baker Building under the NRSMCH, Kolkata.
2024_WBPWD_750334_1
WBPWD/EE-II/CKHED/eNIT-41/ 24-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
NRSMCH Kolkata
As per NIT
4 documents required · 4 mandatory
₹11,861
P-12, CIT Road, Kol-14
8 Oct 2025
12 Sept 2024
25 Oct 2024
12 Sept 2024
23 Oct 2024
19 Sept 2024
17 Sept 2024
Amount
Distn. Wiring in 22/0.3 (1.5 sqmm) single core standard 'FR' PVC insulated & unsheathed single core standard copper wire (Finolex/Havells/RR/Kable Unilay) in 19 mm core, 3 mm thick polythyn pipe complete with all accesorries embedded in wall to light/fan/call bell points with modular type switch (Brand approved by EIC) fixed on modular GI switch board with top cover place flushed in wall incl. mending good damages to original finish. (Average run 8 mtrs.)
a) On board [Vide page no-E-24,item no-3(a)]
b) Average run 10 mtr [Vide page no-E-25,item no-5(e)]
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20/25mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required.. [Vide page No E-14, Item No-1(a) ]
a) 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC [Vide page No E-14, Item No-1(a). iii ](For Power plough and Computer point)
b) 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC [Vide page no-E-9,item no-1(a1)]
c) 2x6 sqmm+1x 4 sqmm ECC) [ TPNDB to SPNDB ] [Vide page No E-14, Item No-1(a). iv ]
d) 4 x 16 sqmm + 2 x 10 sqmm ECC) [ VTPN to TPNDB ] [Vide page No E-9, Item No-1(g1) ] & E-16, 7(b)
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.[Vide page No F-5, Item No-9 (i)& (ii)]
a) 2x2.5 sqmm+1x 1.5 sqmm ECC
b) 2x6 sqmm+1x 4 sqmm ECC) [ TPNDB to SPNDB ]
d) 4 x 16 sqmm + 2 x 10 sqmm ECC) [ VTPN to TPNDB ]
Supplying & Fixing 240 V AC/DC superior type Ding-Dong Call Bell (Anchor) on HW board incl. S&F HW board. [Vide page No D-13, Item No-20a ]
Supply & Fixing 240 V, 3 nos. 16 A, 3 pin Modular type plug socket with 3 nos. 16A Modular type switch (Brand approved by EIC), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 12 Module GI Modular type switch board with 2 row 12 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-18,13]
Supply & Fixing 240 V, 4 nos. 6/16 A, 5 pin Modular type plug socket with 4 nos. 16A Modular type switch, 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-19,15 ] (Make:- Legrand/Cabtree)(Four number room for Computer point)
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. Incoming - 230V,40A, DPMCB Isolator (1-nos) Outgoing - 10KA, (C-characteristics) 6-32A, SPMCB - (12-nos)
2+12 way [Legrand/ L&T/ ABB/siemens]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment [D-10, 14] Incoming - 415V,63A, FPMCB Isolator (1-nos) Outgoing - 10KA, (C-characteristics) 6-32A, SPMCB - (18-nos)
6 way [Legrand/ L&T/ ABB/]
S & D 48″ sweep, 230V 1-Ph. AC ceiling fans incl. all accss. The capacitor of fan must be P-2 type brust proof & must have safety wire directly linked from fan hook to stator of fan. 1200 mm Sweep [Make:Crompton-Aura Metallic/Orient-Quassar/Rivera hispeed) --- Color-Brown], as directed by EIC.
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. [ C-3,21a ]
S & F of recessed mounted 2x2 LED luminaries down light LED fittings [make- Crompton Cat no LCTLRNE-36-FO-CDL or equivalent cat of Bajaj/Phillips] directly suspended from the ceiling with S & F of 2x2 LED luminearies frame incl. connecting the length of PVC insulated wire and mending good damages to original finish and painting as directed by EIC.
Supply and Fixing Single LED T/L fittings( Philips TMC 501 P 1xT-LED 22W P3241) incl. 1x MAS LED tube (PC body) 1200mm 18W865 T8 I --2100 lm.)
Supply and fixing Twin LED T/L fittings( Philips TMC 501 P 2xT-LED 22W P3242) incl. 2x MAS LED tube (PC body) 1200mm 18W865 T8 I --2100 lm.)
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “U” type MS clamp whose both side fixed on ceiling with suitable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 3x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. ][Vide page No C-2, Item No-17]
Supply & Fixing 240 V, 25 A, Modular type starter and 2 Module GI Modular type switch board with 2 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Make:- Legrand/Cabtree) [E-19,20(a)&2(a)]
Supply of 250V 450 mm sweep H D Wall fan complete fully (Metal Body) 18” Air Circulator (EPC)
Supplying & Fixing of 250 volts, 50Hz, sweep 1420 R.P.M. heavy duty exhaust fan complete with all accessories after making hole on wall and mending good damages as per practicable incl.(Make-EPC) as to GS.
a) 300 MM (12”)(Toilet)
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) [D-14,32 ]
300 MM (12”) for Al [D-14,32(a)]
Labour cost for dismantling the worn out and defunct portion of the wiring scattered position through out the 1st floor by trained electrician on running line keeping utiliity system un-interrupted.
Supply 2 TR capacity concealed type Split Air Conditioner of rated cooling capacity of 24000 BTU/hr. with rotary compressor,one no IDU of rated power supply-230V-1ph-50Hz. , 1no. ODU. Air-flow/per IDU:- 1200CFM. ( Make: Hitachi/O-general/ Mitsubishi-Electric)
Copper Refrigeration pipe line for liquid and suction line with fittings, elbows, bends, supports & brackets (Make-Ryoku)
a) Liquid Line (3/8" OD with 0.6 mm thick)
b) Suction Line (5/8" OD with 0.7mm thick)
Supply & Fixing Pipe Insulation in liquid & suction line with 9mm nitrile rubber tube (Accoflex)
a) Liquid Line (3/8" OD with 0.6 mm thick)
b) Suction Line (5/8" OD with 0.7mm thick)
Control copper Cabling from Condensing Unit to control panel (Make: KEI/polycab/ finolex)
a) 4 core 2.5 sq.mm communication cable
Erection & Commissioning Charges incl. refrigerant R-410A / R-22 for 4TR concealed type Split Air Conditioner.
S & L of Drain Water piping work out of PVC / HDPE hard pipes of following sizes incl. fitting, accessories, bends, elbows, tees, flanges, tapings,wall sleeves, hangers, supports, anchors.
a) 25 mm dia
Charges for scaffolding arrangement incl. lifting for outdoor & indoor units
Supply and fixing flexible canvass connection for concealed split air-conditioners.
charges for trap door of 1600 mm x 600 mm and 9 mm thickness made of aluminium channel & ply wood for IDU maintenance.
Supply and Fixing AL power Coated countintuous girll (Make-Premier)
Supplying, fabrication & fixing M.S u-channel of 6 mm thick of size (50 mm x 50 mm x 6 mm) for making platform for installation of outdoor unit of 2 TR Concealed split and cassette AC incl. drilling 2 nos holes in each channel including cutting holes into the wall & grouting the same with cement concrete (1:1 ½ :3) etc. fabricated with horizontal angle of 25 mm x 25 mm x 6 mm including supporting angle 40 mm x40mm x 6 mm in each platform in outer edge for transmitting the load centrally through 2Nos. (50 mm x 50 mm x 6 mm) Angle inserted into the exiting wall. The entire structure should be barricaded & safe for ODU maintenance. Area of the platform is 2Mtr. x 1.2Mtr.or as per Machine configuration & load with adequate service access as per direction of EIC Structural design should be approved by E.I.C.
Supplying, fitting & fixing in position suspended boxing for return air arrangement & indoor units of concealed split airconditioner with frame work of aluminium hollow section of size 50mm x25mm (2.0mm thickness) combined with aluminium corners of size 38mm x 25mm, suspended by aluminium hollow tube section of size 38mm x 25mm ,25mm x 25mm powder coated wall angle with aluminium composit panel of thickness 3.0mm comprising of protective film, polyester coating, primer, aluminium coil, adhesive film, polyethylene core again with one layer adhesive film, aluminium bottom coating and finally service coating as per manufacturer's specification finished with aluminium screw and silicon sealent including suitable arrangement for grill fixing complete in all respect as per direction of EIC.
Cutting iron windows and macking door there for passage for outdoor installation, fixing and provision for future maintenance purpose. Including charges of welding , masonary charges, labour charges and materials charges for sand ,cement , chipes etc.
Rate should be quoted incl. of all taxes and cess.
Defect Liability period : 1)1 year
OVERSEAS TRADING AND SUPPLIES CORPORATION (BID ID -5656494)
ALPHA ELECTRICALS (BID ID -5685114)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .