GDG Prasad Raju, Sc F, CCE
CCE (RnD) Estates South Chandrayangutta Hyderabad - 05
Conversion of Mechanical Creep Drive to Electrical Creep Drive with VVVF Drivers for 20 TON Capacity Double EOT at Site-N, Nagarjuna Sagar
2022_DRDO_677996_1
CCEESTS/ENQ/345/15551721
Limited
Miscellaneous Works
Item Rate
365 days
Nagarjuna Sagar
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
Exempted
13 Apr 2022
9 Mar 2022
31 Mar 2022
9 Mar 2022
30 Mar 2022
9 Mar 2022
90 days
(i) DRAG CHAIN
(a) Dismantling of existing system and installation of drag chain system providing suitable supports for crane Length of Cable Carrier - 38.475 Mtrs No of links - 578 Nos Inner Width - 150 mm Outer Width - 172 mm Bending Radius - 140 mm Height - 44 mm Link - 60 mm Pitch - 66.5 mm
(b) Supply of End Carriers - 1 Set
(c) Supply of Glide Shoe on link - 1156 Nos
(d) Supply of Divers - 578 Nos
(e) Supply and fixing of Floating brackets/ Mounting Plate - 1 Nos
(f) Supply and fixing of Galvanised steel gliding - 75 Kgs
(ii) VVVF DRIVES
Supply and instalation of drives for all motions of the crane. 1No x20HP VFD for Hoist mechanism incluidng Brake Resisters SINAMICS G120 POWER WITHOUT FILTER WITH BUILT IN BRACKING CHOPPER 3AC380- 480V OUTPUT HIGH OVERLOAD LOW LOAD 1NOx2HP VFD for CT mechanism SINAMICS G120C POWER WITHOUT FILTER WITH BUILT IN BRACKING CHOPPER 3AC380-480V 47-63 HZ UNIFIED I/O INTERFACE 6DI, 2DO, 1AO, 1AO SAFE TORQUE OFF INTIGRATED FIELDBUS USS/MODBUS RTU WITH BOP-2 1NOx5HP VFD for LT mechanism SINAMICS G120C POWER WITHOUT FILTER WITH BUILT IN BRACKING CHPPER 3AC380-480V 47-63 HZ UNIFIED I/O INTERFACE 6DI, 2DO, 1AO, 1AO SAFE TORQUE OFF INTIGRATED FILEDBUS USS/MODBUS RTU WITH BOP-2 Make: ABB, Siemens, L&T
(iii) ELECTRICAL DRIVE PANEL
Dismantling of existing panel and supply of new panel with suitable Standard electrical Enclosure for crane Material sheet all round solid constructions Surface finish Dip coat Powder coated Protection as per IP66 Accessories 2 no's of Eye bolts, reinforcement plates
(iv) CABLES
Inspection Existing wiring and Removed/Replace the damaged cables for Hoist, Cross Travel & Long Travel of the crane. Cable sizes 2.0 Sq. mm x 3 Core Cable sizes 2.5 Sq. mm x 3 Core Cable sizes 6 Sq.mm x 4 Core. All cable will be provided suitably de-rated for grouping and higher ambient temperature. Cable laying and terminations will be done as site Existing Crane Space availability
(v) CABLE TRAY
Supply the cable tray for all motions of the crane. The cable tray supporting structures shall be of steel and galvanized. This supporting structure will comprise of two parts, which are Vertical support channels & Horizontal supporting arms. This Horizontal supporting arms. This Horzontal supporting arm will be welded as per space availability and site conditions
(vi) CRANE OVERHAULING
(a) MOTORS :- When checking slip ring brush holders it is necessary to remove metal and carbon dust from the box the rings are to be wiped with cotton if there is oil on ring the cloth should be soaked in pertrol. Scorched rings can be polished with fine emery paper - 4 Nos
(b) BRAKES :- All brakes a periodical and correct maintenance will ensure correct functioning of the brake, ensuring safety and increasing its lifetime after 150 operating hours or monthly. It is recommended to check a brake easy movement of brake linkage, cleanliness of contact surface, reserve stroke of thrustor, lining wear r (lining thickness) condition of the brake drum, brake spring tension (torque) and proper funcitioning of limit/Check the reserve stroke of the thruster when the brake drum is cool Check the thickness of the brake linings. When the thickness of the brake Linings s less than 3 mm at the lowest point in case of glued/bonded linings or is less than 5 mm in case of riveted linings, replace/change the brake shoes - 4 Set
(c) GEAR BOX :- All gear boxes are servicing including Oil and greasing & Dismantling of existing creep gear boxes from all mechanism of EOT crane - 4 Set
(d) ROPE :- Dismantling of existing rope checking, cleaning & Install with applying rope compund - 1 No
(e) ROPE DRUM :- Inspection and servicing of rope drum, greasing the bearings if required re-alignment of drum assly - 1 No
(f) BRG HOUSINGS :- Inspection and servicing of housing for CT< Motion - 8 Nos
(g) LT&CT WHEEL ASSLY :- Inspection and Realignment of all wheel assly of crane required facteners are changed accordingly- 16 Nos
(h) CRAB :- Inspection and Servicing total trolley and lying cable tray including suitable supports - 1 No
(j) COUPLING :- Inspection and Servicing of all couplings greasing - 11 Nos
ANJANI ELECTRICALS
Shri Sai Enterprises
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .