Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical 790 STREET NO 1 PATEL NAGAR HISAR 125001 | HISAR | HISAR | HARYANA | 125001 | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical KATTHAL ROAD NEAR PNB BANK AMARHERI JIND 2025R21311 | JIND | JIND | HARYANA | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical 209 210 AGGARWAL TOWER PLOT NO 2 SECTOR 5 ROHINI NORTH WEST DELHI DELHI 110085 | DELHI | NORTH WEST DELHI | DELHI | 110085 | Admitted-Fee/PreQual/Technical |
| 4 | Admitted-Fee/PreQual/Technical DSS 194 POCKET A SEC 14 125001 | HISAR | HARYANA | 125001 | Admitted-Fee/PreQual/Technical |
Tender Value
₹5.6 L
EMD Value
₹11,200
Closing Date
26 Nov 2025, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AMIT GOYAL
ED - Rohtak
Pdg. Fire Alarm System
2025_HRY_484426_1
202570174970 AE1A 4889 AE81 B4D74583EEE2667BAR
Open Tender
Electrical Works
Works
90 days
DHAKLA
Technical documents as per approved DNIT conditions.
3 documents required · 3 mandatory
₹1,000
₹11,200
Yes
22 Jan 2026
19 Nov 2025
27 Nov 2025
19 Nov 2025
26 Nov 2025
19 Nov 2025
[23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate]
SITC of Micro processor based wire fault tolerant, networkable type fire alarm / detection control panel ( having nos. of 1 loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 character L C D unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80LED Indicators. The Panel shall have 3 Serial Ports. The panel shall have a built in power supply and battery charger along with maintenance free 24 AH,2 x 12 volt SMF lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS/ as per specifications complete in all respect up to the entire satisfaction of Engineer-in – charge of work Makes : Honeywell Morley/ Siemens cerberus/ GST .
Supply Installation Testing and Commissioning of addressable multisensor detector with a combination of Optical and Thermal including mounting base, auto addressing feauture as required. Detetctor should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54/ VDs/UL certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module after 20 devices) Make: Honeywell Morley / Siemens Cerberus / GST
Supply Installation Testing and Commissioning of intelligent Analog Addressable type Manual Call Point having Surface or flush mounting option fully compliat to EN 54 having Rotary Decade switches for addressing with back box for mounting as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make: Honeywell Morley / Siemens Cerberus / GST
Supply Installation Testing and Commissioning of Addressable Loop powered sounder with strobe / flasher complete with mounting base as required conforming to BS5839 standards and duly approved by EN54/UL/VDS required to complete the job in all respect up to the entire satisfaction of Engineer – in Charge of work. Make: Bosch / Siemens Cerberus / GST
Supply Installation, Testing and Commissioning of Glow Type Exit Sign Board photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class - I material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener Managed Type including cost of labour and material required to complete the job in all respect. Make Omex/ Savmax/Fyrmax/Firesec
Supply Installation Testing and Commissioning of Addressable Monitor Module for monitoring of a line with EOL resistor/ Potential free contact/ voltage monitoring shall be EN54/UL/VDS approved. (In case of 2 monitoring features in one module (points) each point shall be consider separately for payment). Make: Honeywell Morley / Siemens Cerberus / GST
Supply Installation Testing and Commissioning of Addressable Control Relay Module with flexible network structures with a maximun switching current of 1A @ 30V DC. Shall be EN54/UL/VDS Certification Make: Honeywell Morley / Siemens Cerberus / GST
Supply Installation Testing and Commissioning of UL/EN54/LPCB listed and FM Approved Line Isolator for Isolating the section of circuit in case of short in the addressable Loop wiring Make: Honeywell / Siemens Cerberus / GST
Supply Installation Testing and Commissioning of minimum 1000 Mtr. Range Siren provided at the roof of the building with separate power supply, relay etc. with all accessories required to complete the job in all respect up to the entire satisfaction of engineer in charge. Make: National/Kheraj
Supply of 9U rack for switch Mounting with Fan and power Strip, PDU, Hardware Mounting Kit (Excluded GST) Make: Netrack/Comrack/D-Link/C PLUS.
SITC of 250 Watt Class D type Power/Booster Amplifier. Amplifier should work on Mains Power Supply of Universal type with PFC, 85~265 Volts AC with a frequency of 45Hz to 65Hz. Power Amplifier should have SMPS of 280 Watt RMS with a Frequency range of 20 Hz - 20 kHz ( plus 0/-0.25 dB) 8O load, 3 dB below rated power. SNR of 119 dB and Balanced Line input and speaker output of 100 V through connectors of phoenix type. Amplifier should have a protection of Short circuit protections like - DC protection, under voltage protection, temperature protection, overload protection and should work in Temperature range of -10°c to 50°c @ 90% relative humidity (non condensing) with Natural dissipation through heat sink and temperature-controlled fan for cooling purpose to protect the amplifier from heating. Approved Make Honeywell / AHUJA / SHURE.
`Supply, Installation, Testing and commissioning of Wall Mount/Ceiling Speaker with operation 15 Watts to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. Make Honeywell / AHUJA / SHURE.
Supply Installation Testing and Commissioning of Speaker Cable 2 Core 1.5 sqmm. Make: Finolex/ Polycab/HAVELLS.
Supply and erection of PVC Insulated and PVC round sheathed multi core annealed bare copper conductor industrial flexible cables for voltage grade 1100 Volts conforming to IS: 694:2010 complete in all respect upto the entire satisfaction of Engineer in charge of the work i 2 core PVC round sheathed copper size 1.5 sq mm Make Polycab/Havells/RR Kabel etc..
stage.html
html • 0.03 MB
technical_562443.pdf
cancelled_1.pdf
pdf • 0.47 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.13 MB
BOQ_562443.xls
BOQ • 0.29 MB
AD0141114.pdf
Additional Documents • 2.41 MB
OT0141114.pdf
Other Document • 1.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .