Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Ref. No.
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹85.2 Cr | - | |
| 2 | Qualified 2ND FLOOR ASHOKA HOUSE ASHOKA MARG ASHOKA NAGAR NASHIK MAHARASHTRA 422011 | NASHIK | MAHARASHTRA | 422011 | Qualified | |
| 3 | Qualified | Qualified | |
| 4 | Qualified 626 6TH FLOOR DLF TOWER A DLF TOWER 626 6TH FLOOR DLF TOWER A JASOLA JASOLA SOUTH DELHI DELHI 110076 | HARIDWAR | SOUTH DELHI | DELHI | 110076 | Qualified | |
| 5 | Qualified | Qualified |
Tender Value
Refer Docs
Closing Date
19 Jul 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Kapil Mandil
Power Grid Corporation of India Limited Saudamini, 3rd Floor, Plot No.-2, Sector-29 Gurgaon (Haryana) - 122001.
Package ARP-DMS-05C for distribution works in Arunachal Pradesh under Comprehensive Scheme for Strengthening of Transmission & Distribution system in NER & Sikkim: Intra State - Arunachal Pradesh
CC-CS/1073-NER/REW-4246/3/G2
Open
Power/Energy Projects/Products
Works
Arunachal Pradesh
₹25,000
31 Aug 2021
4 Jun 2021
19 Jul 2021
4 Jun 2021
19 Jul 2021
4 Jun 2021
22 Jun 2021
Package Name Package ARP-DMS-05C for distribution works in Arunachal Pradesh under Comprehensive Scheme for Strengthening of Transmission & Distribution system in NER & Sikkim: Intra State - Arunachal Pradesh.
Package Code ARP-DMS-05C Bought-out
Specification No. Specification No.: CC-CS/1073-NER/REW-4246/3/G2
Specification No.: CC-CS/1073-NER/REW-4246/3/G2
1 Fill up only green shaded cells in Sch-1, Sch-2, Sch-3 and Bid Form 2nd Envelope.
2 All the cells in Sch-5, Sch-6 are auto filled, therefore no cell is required to be filled up there.
3 Instructions / error messages, if any, will be displayed automatically after selecting the cell.
4 After filling up all the schedues, save the file, take print out of all the schedules and Bid form and sign & stamp and submit them as hard copy of the 2nd envelope (Price part) of the bid. Also ensure to submit the soft copy of the the same file on CD/ DVD.
पावर ग्रिड कारपोरेशन ऑफ इण्डिया लिमिटेड
(भारत सरकार का उद्यम)
Power Grid Corporation of India Limited
(A Government of India Enterprises)
I While filling up the worksheets following may please be observed :
(i) Fill up only green shaded cells.
(ii) Certain data type entries have been restricted, such as Numeric values or limits of numeric values.
(iii) Select only the options provided in pull down menus.
(iv) Do not link any cell of this work book with any other work book.
(v) Do not use copy & paste or cut & paste options for filling up the data.
(vi) Do not reformat any of the cell of the work book.
II This Workbook consists of following worksheets :
Opening page of the workbook.
Names of Bidder :
● Select Sole Bidder or JV (Joint Venture) from the pull down menu. Do not leave this cell blank.
● Select nos. of the JV Partners other than the Lead Partner from drop down menu.
● In case of JV partners more than 2, enter details of 3rd & more partners along with details of 2nd partner.
● Fill up names and address of the Sole Bidder and /or Joint Venture.
● Fill up date in dd-mm-yyyy format from drop down menu.
● Click for Sch-1 given at the right top of the worksheet to go to Sch-1.
Sch-1 (Ex-works Prices) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
● Type Test charges if applicable shall appear automatically after filling up Sch-7 appropriately.
Sch-2 (Freight & Insurance Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-3 (Erection Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-4 (Training Charges) :
● Not applicable, hence no cell is required to be filled up.
Sch-5 (Summary of GST applicable on supply of Goods and Services) :
● Amount of GST shall be calculated automatically.
● Summary of all the Schedules without considering discount (mentioned in the work sheet discount) shall be displayed automatically.
● No cell is required to be filled in by the bidder in this worksheet.
Sch-7 (Type Test Charges) :
● Not applicable, hence no cell is required to be filled up.
● Total of this Sch-7 shall automatically appear in Sch-1.
Bid form 2nd Envelope :
● Fill up ref. no. as bidder's ref no. of this letter.
● This letter shall consider the net price as per Sch-6 (After Discount).
● Fill up names & Designation of the representatives of other JV partner(s) if the bidder is JV (Joint Venture) .
● Fill up additional information as required.
Happy Bidding !
Package ARP-DMS-05C for distribution works in Arunachal Pradesh under Comprehensive Scheme for Strengthening of Transmission & Distribution system in NER & Sikkim: Intra State - Arunachal Pradesh.
Specification No.: CC-CS/1073-NER/REW-4246/3/G2 Sole Bidder 1
JV (Joint Venture) 2 or more
Enter following details of the bidder
Specify type of Bidder [Select from drop down menu] 2 0
Name of Lead Partner
Address of Lead Partner
Name of other Partner - 1
Address of other Partner - 1
Name of other Partner - 2 (more, if any)
Address of other Partner - 2 (more, if any)
Specification No.: CC-CS/1073-NER/REW-4246/3/G2 SCHEDULE-1
Package ARP-DMS-05C for distribution works in Arunachal Pradesh under Comprehensive Scheme for Strengthening of Transmission & Distribution system in NER & Sikkim: Intra State - Arunachal Pradesh.
(SCHEDULE OF RATES AND PRICES)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services Direct
Name : Power Grid Corporation of India Ltd., Bought-out
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Plant and Equipment (including Mandatory Spares Parts) to be supplied , including Type Test Charges for Tests to be conducted:
All Prices are in Indian Rupees.
SI. No. PR No PR Line Item No Activity Description Material Code HSN Code Whether HSN in column ‘6’ is confirmed. If not indicate applicable the HSN code # Rate of GST applicable ( in %) Whether rate of GST in column ‘8’ is confirmed. If not indicate applicable rate of GST # Item Description Unit Qty. Unit Ex-works price (excluding GST) Total Ex-works price (excluding GST)
(I) PKG DMS WORKS: ARP-DMS-05C
1 7000014244 10 Substation Works 1000001109 85042200 18 2.5MVA, 33/11 kV power transformer with Cu winding along with allaccessories and oil EA 16 INCLUDED 0 0 0%
2 7000014244 20 Substation Works 1000004936 85042200 18 5MVA, 33/11 kV power transformer with Cu winding along with allaccessories and oil EA 7 INCLUDED 0 0 5%
3 7000014244 30 Substation Works 1000022797 85352122 18 Supply of 33 kV , 1250 Amp 25kA 3 phaseVaccum Circuit Breaker with structure(combined structure to facilitatemounting of CT's as per apprd drg)andall accessories as per TS EA 37 INCLUDED 0 0 12%
4 7000014244 40 Substation Works 1000002094 85353090 18 36 kV, 630A, 25 KA, 3-Phase DoubleBreak Isolator without E/S EA 53 INCLUDED 0 0 18%
5 7000014244 50 Substation Works 1000002095 85353090 18 36 kV, 630A, 25 KA, 3-Phase DoubleBreak Isolator with one E/S EA 14 INCLUDED 0 0 28%
6 7000014244 60 Substation Works 1000000001 85359090 18 Supply of 33 kV, 1 phase , 300-150/1-1 Amp Current transformer (longwithall accessories as per TS EA 111 INCLUDED 0 0
7 7000014244 70 Substation Works 1000020373 85354010 18 Supply of 30 kV, 1 phase, 10 KA porcelain housing ZnO LA with allaccessories as per TS EA 132 INCLUDED 0 0
8 7000014244 80 Substation Works 1000020375 85354010 18 Supply of 9 kV, 1 phase, 10 KA porcelain housing ZnO LA with allaccessories as per TS EA 144 INCLUDED 0 0
9 7000014244 90 Substation Works 1000000269 85359090 18 Supply of 33/?3 kV/110 /?3 Volts, 1 phase PT alongwith all accessoriesas per TS EA 111 INCLUDED 0 0
10 7000014244 100 Substation Works 1000044608 85462023 18 33 KV SOLID CORE BUS POST INSULATORS, FITTINGS AND ACCESSORIES SET 78 INCLUDED 0 0
11 7000014244 110 Substation Works 1000044609 85462023 18 45 KV SOLID CORE BUS POST INSULATORS, FITTINGS AND ACCESSORIES SET 9 INCLUDED 0 0
12 7000014244 120 Substation Works 1000028385 85042100 18 100 KVA, 33/0.433 KV, 3 PH, 50 HZ, ONAN, OUTDOOR STATION TRANSFORMERON DOUBLE POLE STRUCTURE ALONG WITH TRANSFORMER OIL AND ALLACCESSORIES AS PER TS. EA 7 INCLUDED 0 0
13 7000014244 130 Substation Works 1000022827 73089070 18 Galvanised STEEL TUBULAR POLE 540 MPA, SP64, 12 METER EA 58 INCLUDED 0 0
14 7000014244 140 Substation Works 1000044624 73089070 18 GALVANISED STEEL TUBULAR 12 MTS. 540,SP-64 POLE, MADE FROM STEELGRADE E410C EA 6 INCLUDED 0 0
15 7000014244 150 Substation Works 1000015954 73082011 18 Fabrication, galvanising and supply of Lattice Structures (MS Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 79.02 INCLUDED 0 0
16 7000014244 160 Substation Works 1000044621 73089040 18 GALVANISED FABRICATED STRUCTURE FOR 33 KV BUS & LINE GANTRY- GRADE CSTEEL STRUCTURE AS PER IS 2062 MT 8.8 INCLUDED 0 0
17 7000014244 170 Substation Works 1000022813 73089090 18 Fabrication and Supply of M.S. Galvanised items- Pole Top Bracket,V-Cross arm, Back Clamps for V-Cross arm , D P Channel, D P Channelclamp, Stay clamps angle, Stay clamps side, D P cross bracing &clamps,Guarding arm etc etc. complete as required. MT 31.82 INCLUDED 0 0
18 7000014244 180 Substation Works 1000044622 73089040 18 GALVANISED FABRICATED STRUCTURE FOR STATION TRANSFORMER, DP STRUCTUREFOR OUTGOING 11 KV FEEDERS, PORECLAIN LA, ISOLATOR, BUS COUPLERISOLATOR & BUS POST INSULATOR- GRADE C STEEL STRUCTURE AS PER IS 2062 MT 3.53 INCLUDED 0 0
19 7000014244 190 Substation Works 1000022819 73181500 18 nuts,bolts,foundation bolts and washer and other accessories forstructures. MT 12.32 INCLUDED 0 0
20 7000014244 200 Substation Works 1000022807 85462019 18 INSULATOR HARDWARE & ACCESSORIES ALL COMPLETE ALONG WITH 70 KN B&SDISC INSULATOR ( ONE SET CONSISTING OF 4NOS DISC INSULATOR) AS PERTECHNICAL SPECIFICATION. SET 186 INCLUDED 0 0
21 7000014244 210 Substation Works 1000030867 76141000 18 ACSR WOLF CONDUCTOR KM 1.702 INCLUDED 0 0
22 7000014244 220 Substation Works 1000037509 72125090 18 75X8 MS FLAT FOR EARTHING MT 42.56 INCLUDED 0 0
23 7000014244 230 Substation Works 1000029996 72125090 18 60X8MM GALVANISED FLAT FOR RAISER MT 6.4 INCLUDED 0 0
24 7000014244 240 Substation Works 1000012682 73063010 18 40mm x 3000 mm long GI Pipe earth electrode for earth pit alongwithclamping arrangement to connect GI Wire as per TS EA 236 INCLUDED 0 0
25 7000014244 250 Substation Works 1000004302 72159090 18 40 mm MS rod for Main Earthmat M 1400 INCLUDED 0 0
26 7000014244 260 Substation Works 1000028395 72149990 18 20 MM DIA., 3000 MM LONG GI ROD AND OTHER ACCESSORIES AS PER TECHNICALSPECIFICATION. SET 238 INCLUDED 0 0
27 7000014244 270 Substation Works 1000029987 85446090 18 SUPPLY OF 11 KV, XLPE INSULATED, ARMORED ALUMINIUM CABLE AS PERTS - 3CX400 SQ. MM M 350 INCLUDED 0 0
28 7000014244 280 Substation Works 1000029986 85446090 18 SUPPLY OF 11 KV, XLPE INSULATED, ARMORED ALUMINIUM CABLE AS PERTS - 3CX120 SQ. MM M 2050 INCLUDED 0 0
29 7000014244 290 Substation Works 1000029995 85479090 28 END TERMINATION KIT SUITABLE FOR TERMINATION IN CABLE BOX ON 11KVSIDE OF TRANSFORMER FOR 3CX400 SQ. MM CABLE SET 7 INCLUDED 0 0
30 7000014244 300 Substation Works 1000029994 85479090 28 END TERMINATION KIT SUITABLE FOR TERMINATION IN CABLE BOX ON 11KVSIDE OF TRANSFORMER FOR 3CX120 SQ. MM CABLE SET 16 INCLUDED 0 0
31 7000014244 310 Substation Works 1000029993 85479090 28 END TERMINATION KIT SUITABLE FOR TERMINATION IN 11 KV INDOOR VCBPANEL FOR 3CX400 SQ. MM CABLE SET 7 INCLUDED 0 0
32 7000014244 320 Substation Works 1000029991 85479090 28 END TERMINATION KIT SUITABLE FOR TERMINATION IN 11 KV INDOOR VCBPANEL FOR 3CX120 SQ. MM CABLE SET 39 INCLUDED 0 0
33 7000014244 330 Substation Works 1000029992 85479090 28 OUTDOOR END TERMINATION KIT (REQUIRED AT DOUBLE POLE STRUCTURE ) FOR11 KV 3CX120 SQ. MM. CABLE SET 24 INCLUDED 0 0
34 7000014244 340 Substation Works 1000000496 85446020 18 1.1kV grade 3.5Cx50 sqmm Armoured (PVC) Power Cable M 525 INCLUDED 0 0
35 7000014244 350 Substation Works 1000000512 85446020 18 1.1kV grade 4Cx16 sqmm (PVC) Power Cable M 1275 INCLUDED 0 0
36 7000014244 360 Substation Works 1000000476 85446020 18 1.1kV grade 2Cx10 sqmm Armoured (PVC) Power Cable M 645 INCLUDED 0 0
37 7000014244 370 Substation Works 1000000480 85446020 18 1.1kV grade 2Cx2.5 sqmm Control Cable M 2590 INCLUDED 0 0
38 7000014244 380 Substation Works 1000000520 85446020 18 1.1kV grade 5Cx2.5 sqmm Control Cable M 8880 INCLUDED 0 0
39 7000014244 390 Substation Works 1000000446 85446020 18 1.1kV grade 10Cx2.5 sqmm Control Cable M 4440 INCLUDED 0 0
40 7000014244 400 Substation Works 1000000450 85446020 18 1.1kV grade 12Cx2.5 sqmm Control Cable M 700 INCLUDED 0 0
41 7000014244 410 Substation Works 1000028408 85371000 18 33KV CONTROL & RELAY PANEL ALONGWITH E/F & O/C RELAYS, MIMIC DIAGRAM,VOLTMETER, AMMETER, ANNUNCIATION WINDOWS WITH ANNUNCIATION RELAYS ANDOTHER COMPONENTS ETC AS PER TS FOR CONTROLLING POWER TRANSFORMER 33 KVVCB WITH STATIC TRI-VECTOR ENERGY METER SET 16 INCLUDED 0 0
42 7000014244 420 Substation Works 1000022810 85371000 18 SUPPLY OF 33 KV TRF. C&R PANEL (WITH O/C & E/F PROTECTION ALONGWITHALL OTHER MANDATORY SYSTEM REQUIRED FOR 5 MVA, 33/11 KV TRF) EA 7 INCLUDED 0 0
43 7000014244 430 Substation Works 1000028406 85371000 18 33KV CONTROL & RELAY PANEL ALONGWITH E/F & O/C RELAYS, MIMIC DIAGRAM,VOLTMETER, AMMETER, ANNUNCIATION WINDOWS WITH ANNUNCIATION RELAYS ANDOTHER COMPONENTS ETC AS PER TS FOR CONTROLLING 33 KV FEEDER VCB WITHSTATIC TRI-VECTOR ENERGY METER SET 14 INCLUDED 0 0
44 7000014244 440 Substation Works 1000022778 85352121 18 Supply of 11 kV, 630 Amp C&R Cum VCBPanel for incoming 11 kV feeder withPT. EA 23 INCLUDED 0 0
45 7000014244 450 Substation Works 1000022776 85352121 18 Supply of 11 kV, 630 Amp C&R Cum VCBPanel for 11 kV Bus Coupler. EA 11 INCLUDED 0 0
46 7000014244 460 Substation Works 1000022777 85352121 18 Supply of 11 kV, 630 Amp C&R Cum VCBPanel for Out-Going 11 kV feeder EA 25 INCLUDED 0 0
47 7000014244 470 Substation Works 1000000571 85073000 28 110V, 150AH, Ni-Cd type Battery Set andall other accessories complete. SET 16 INCLUDED 0 0
48 7000014244 480 Substation Works 1000000567 85044030 18 110 V, Float-Cum-Boost Battery Chargerwith full wave, full controlrectification, 50Hz Input Voltage forcharging 110V, 150AH Battery alongwithinbuit DCDB, connectors etc. completeand conection with 110V, 150AH BatterySet and single phase AC input supply. SET 16 INCLUDED 0 0
49 7000014244 490 Substation Works 1000004303 85371000 18 415V AC Distribution Board (ACDB) as per Technical Specification SET 16 INCLUDED 0 0
50 7000014244 500 Substation Works 1000028787 85371000 18 BAY MARSHELLING KIOSK COMPLETE AS PER TS EA 24 INCLUDED 0 0
51 7000014244 510 Substation Works 1000022818 85371000 18 LIGHTING SYSTEM COMPLETE FOR SWITCHYARD INCLUDING MAINGATE &SUBSTATION BOUNDARY AS PER TS EA 7 INCLUDED 0 0
52 7000014244 520 Substation Works 1000022817 94054090 12 LIGHTING SYSTEM COMPLETE FOR CONTROL ROOM BUILDING AS PER TS EA 7 INCLUDED 0 0
53 7000014244 530 Substation Works 1000029990 76169990 18 CLAMP & CONNECTORS ETC FOR SUB-STATION HAVING 2 NOS. 33/11 KVTRANSFORMERS SET 1 INCLUDED 0 0
54 7000014244 540 Substation Works 1000022811 76169990 18 CLAMP & CONNECTORS ETC FOR SUB-STATION HAVING 2 NOS. 33/11 KVTRANSFORMERS, 1 NO. 33 KV LINE SET 4 INCLUDED 0 0
55 7000014244 550 Substation Works 1000029989 76169990 18 CLAMP & CONNECTORS ETC FOR SUB-STATION HAVING 2 NOS. 33/11 KVTRANSFORMERS, 2 NOS. 33 KV FEEDER. LOT 2 INCLUDED 0 0
56 7000014244 560 Substation Works 1000029988 76169990 18 CLAMP & CONNECTORS ETC FOR 1 NEW 33 KV LINE BAY IN EXISTING S/S LOT 2 INCLUDED 0 0
57 7000014244 570 Substation Works 1000033211 76169990 18 CLAMP & CONNECTORS ETC FOR 2 NEW 33 KV LINE BAY IN EXISTING S/S SET 2 INCLUDED 0 0
58 7000014244 580 Substation Works 1000033210 76169990 18 CLAMP & CONNECTORS ETC FOR 1 NEW 33/11 KV TRANSFORMER BAY INEXISTING S/S LOT 1 INCLUDED 0 0
59 7000014244 590 Substation Works 1000033209 76169990 18 CLAMP & CONNECTORS ETC FOR 1 NEW 33/11 KV TRANSFORMER BAY & 1REPLACEMENT OF EXISTING TRANSFORMER IN EXISTING S/S SET 3 INCLUDED 0 0
60 7000014244 600 Substation Works 1000033212 76169990 18 CLAMP & CONNECTORS ETC FOR REPLACEMENT OF 2 EXISTING TRANSFORMER INEXISTING S/S SET 1 INCLUDED 0 0
61 7000014244 610 Substation Works 1000022798 85359030 18 33 kV , 400 Amp, 3 phase , verticalmounted AB switch as per TS EA 7 INCLUDED 0 0
62 7000014244 620 Substation Works 1000028100 85049010 18 36 kV, 3-Ph Horn Gap Fuse as per Technical Specification EA 7 INCLUDED 0 0
63 7000014244 630 Substation Works 1000022782 85359030 18 11 kV , 400 Amp,3 phase , verticalmounted AB switch for Outgoing DP asper TS EA 25 INCLUDED 0 0
64 7000014244 640 Substation Works 1000012026 84241000 18 6Kg dry chemical powered type Portable Fire extinguisher EA 7 INCLUDED 0 0
65 7000014244 650 Substation Works 1000012022 84241000 18 4.5 kg CO2 type Portable Fire extinguisher EA 7 INCLUDED 0 0
66 7000014244 660 Substation Works 1000027449 84241000 18 22.5 kg CO2 type Portable Fire Extinguisher EA 7 INCLUDED 0 0
67 7000014244 670 Substation Works 1000025035 90303950 18 Digital IR Measurement Test Kit (2KV -10KV) with all necessary accessoriesas per Technical specification. EA 7 INCLUDED 0 0
68 7000014244 680 Substation Works 1000024644 90303100 18 Digital Multimeter for testing EA 14 INCLUDED 0 0
69 7000014244 690 Substation Works 1000024639 90303390 18 Digital Earth Tester-Battery (Rechargeable) Operated Earth Resistance/Resistivity Tester EA 7 INCLUDED 0 0
70 7000014244 700 Substation Works 1000025500 73239990 12 Supply Stainless Steel oil samplingbottles (one liter capacity) as perTechnical specification EA 14 INCLUDED 0 0
71 7000014244 710 Substation Works 1000033187 85471090 28 11 KV DISCHARGE ROD(1 SET OF 3 RODS) SET 7 INCLUDED 0 0
72 7000014244 720 Substation Works 1000033199 90303900 18 BATTERY VOLTAGE TESTER EA 14 INCLUDED 0 0
73 7000014244 730 Substation Works 1000033192 85471090 28 33 KV DISCHARGE ROD (1 SET OF 3 RODS) SET 7 INCLUDED 0 0
74 7000014244 740 33KV Line with ACSR Racoon Conductor 1000030863 76141000 18 ACSR RACOON CONDUCTOR KM 747.58 INCLUDED 0 0
75 7000014244 750 33KV Line with ACSR Racoon Conductor 1000022827 73089070 18 Galvanised STEEL TUBULAR POLE 540 MPA, SP64, 12 METER EA 4439 INCLUDED 0 0
76 7000014244 760 33KV Line with ACSR Racoon Conductor 1000044624 73089070 18 GALVANISED STEEL TUBULAR 12 MTS. 540,SP-64 POLE, MADE FROM STEELGRADE E410C EA 560 INCLUDED 0 0
77 7000014244 770 33KV Line with ACSR Racoon Conductor 1000022825 73089070 18 STEEL TUBULAR POLE 540 MPA, SP76, 14.5 METER EA 504 INCLUDED 0 0
78 7000014244 780 33KV Line with ACSR Racoon Conductor 1000044623 73089070 18 GALVANISED STEEL TUBULAR 14.5 MTS. 540,SP-76 POLE, MADE FROM STEELGRADE E410C EA 56 INCLUDED 0 0
79 7000014244 790 33KV Line with ACSR Racoon Conductor 1000022813 73089090 18 Fabrication and Supply of M.S. Galvanised items- Pole Top Bracket,V-Cross arm, Back Clamps for V-Cross arm , D P Channel, D P Channelclamp, Stay clamps angle, Stay clamps side, D P cross bracing &clamps,Guarding arm etc etc. complete as required. MT 376.03 INCLUDED 0 0
80 7000014244 800 33KV Line with ACSR Racoon Conductor 1000022819 73181500 18 nuts,bolts,foundation bolts and washer and other accessories forstructures. MT 37.6 INCLUDED 0 0
81 7000014244 810 33KV Line with ACSR Racoon Conductor 1000022795 85462033 18 33 KV PORCELAIN PIN INSULATOR WITH 900 MM CREEPAGE DISTANCE ALONGWITH10 KN PIN, NUT AND WASHERS COMPLETE AS PER TS SET 14235 INCLUDED 0 0
82 7000014244 820 33KV Line with ACSR Racoon Conductor 1000022806 85462019 18 INSULATOR HARDWARE & ACCESSORIES ALL COMPLETE ALONG WITH 70 KN B&SDISC INSULATOR ( ONE SET CONSISTING OF 3 NOS DISC INSULATOR) AS PER TS SET 4158 INCLUDED 0 0
83 7000014244 830 33KV Line with ACSR Racoon Conductor 1000022807 85462019 18 INSULATOR HARDWARE & ACCESSORIES ALL COMPLETE ALONG WITH 70 KN B&SDISC INSULATOR ( ONE SET CONSISTING OF 4NOS DISC INSULATOR) AS PERTECHNICAL SPECIFICATION. SET 1782 INCLUDED 0 0
84 7000014244 840 33KV Line with ACSR Racoon Conductor 1000022824 76052990 18 PREFORMED INSULATOR BINDINGS (SUITABLE FOR ACSR CONDUCTOR) FOR 33 KVPIN INSULATOR SET 14235 INCLUDED 0 0
85 7000014244 850 33KV Line with ACSR Racoon Conductor 1000022796 73089090 18 33 kV Stay set complete including Hardware, Stay wire (7/10 SWG), insulator etc as per TS SET 4780 INCLUDED 0 0
86 7000014244 860 33KV Line with ACSR Racoon Conductor 1000022814 85462050 18 GUY STRAIN INSULATORS DESIGNATION 'C' EA 9560 INCLUDED 0 0
87 7000014244 870 33KV Line with ACSR Racoon Conductor 1000022805 73121020 18 Stay wire (7/8 SWG) KG 42293.52 INCLUDED 0 0
88 7000014244 880 33KV Line with ACSR Racoon Conductor 1000032344 72171010 18 8SWG GI WIRE FOR PROTECTIVE GUARDING & EARTHING AS PER TS KG 70264.33 INCLUDED 0 0
89 7000014244 890 33KV Line with ACSR Racoon Conductor 1000012682 73063010 18 40mm x 3000 mm long GI Pipe earth electrode for earth pit alongwithclamping arrangement to connect GI Wire as per TS EA 888 INCLUDED 0 0
90 7000014244 900 Highway Crossing 1000001990 85446090 18 33 kV 3Cx300 sq.mm aluminium, armoured XLPE cable M 1200 INCLUDED 0 0
91 7000014244 910 Highway Crossing 1000008867 85446020 18 33 kV Outdoor Termination Kit suitable for 33 kV, 3Cx300 sq.mm XLPEcable SET 16 INCLUDED 0 0
92 7000014244 920 Highway Crossing 1000022798 85359030 18 33 kV , 400 Amp, 3 phase , verticalmounted AB switch as per TS EA 8 INCLUDED 0 0
93 7000014244 930 OPGW Works 1000030947 85447090 18 24 FIBRE (DWSM) OPGW FIBRE OPTIC CABLE (WITH CENTRAL FIBRE OPTIC UNITOF STEEL TUBE DESIGN ) KM 222 INCLUDED 0 0
94 7000014244 940 OPGW Works 1000020444 82057000 18 Suspension clamp assembly for 24 fibre OPGW EA 4420 INCLUDED 0 0
95 7000014244 950 OPGW Works 1000010558 82057000 18 Dead end Tension clamp for 24 fibre OPGW EA 16 INCLUDED 0 0
96 7000014244 960 OPGW Works 1000031039 82057000 18 TENSION FITTINGS ASSEMBLY FOR 24F OPGW INCLUDING ALL ACCESSORIES FORJOINT BOX (SPLICING) LOCATION SET 111 INCLUDED 0 0
97 7000014244 970 OPGW Works 1000017489 82057000 18 Passing Tension clamp for 24 fibre OPGW EA 777 INCLUDED 0 0
98 7000014244 980 OPGW Works 1000031041 82057000 18 TENSION FITTINGS ASSEMBLY ON SUSPENSION TOWER FOR 24F OPGW INCLUDINGALL ACCESSORIES AT JOINT BOX (SPLICING) LOCATION SET 20 INCLUDED 0 0
99 7000014244 990 OPGW Works 1000010817 82057000 18 Down Lead clamp Assembly for 24 fibre OPGW EA 1270 INCLUDED 0 0
100 7000014244 1000 OPGW Works 1000022417 82057000 18 Vibration Damper for 24 fibre OPGW EA 50 INCLUDED 0 0
101 7000014244 1010 OPGW Works 1000014198 85353090 18 Joint Box for 24 fibre OPGW EA 111 INCLUDED 0 0
102 7000014244 1020 OPGW Works 1000030834 85447090 18 24 FIBRE ADSS KM 20 INCLUDED 0 0
103 7000014244 1030 OPGW Works 1000034328 82057000 18 INSTALLATION HARDWARE SET FOR 24F ARIEL (ADSS) FIBRE OPTIC CABLINGINCLUDING ALL CABLE FITTINGS & ACCESSORIES EXCEPT JOINT BOX. SET 20 INCLUDED 0 0
104 7000014244 1040 OPGW Works 1000014198 85353090 18 Joint Box for 24 fibre OPGW EA 10 INCLUDED 0 0
105 7000014244 1050 OPGW Works 1000023470 85372000 18 OPGW Fibre Optic Distribution Panel (FODP): Indoor Type: 48F EA 11 INCLUDED 0 0
106 7000014244 1060 OPGW Works 1000023471 85372000 18 OPGW Fibre Optic Distribution Panel (FODP): Indoor Type: 96F EA 3 INCLUDED 0 0
107 7000014244 1070 OPGW Works 1000037545 85447090 18 24F (DWSM) APPROACH FIBRE OPTIC CABLE KM 9 INCLUDED 0 0
108 7000014244 1080 OPGW Works 1000013927 39269079 28 Installation hardware set for above 24 Fibre, Fibre Optic ApproachCable SET 9 INCLUDED 0 0
109 7000014244 1090 66KV S/C Line 1000015274 73082011 18 Fabrication, galvanising & supply of various types of towers & towerparts, tower/leg extensions (complete) excluding step bolt, stubs andbolts & nuts but including hangers, D-Shackles, pack washers etc.-MSSteel for Normal Towers MT 10.413 INCLUDED 0 0
110 7000014244 1100 66KV S/C Line 1000013391 73082011 18 Fabrication, galvanising & supply of various types of towers & towerparts, tower/leg extensions (complete) excluding step bolt, stubs andbolts & nuts but including hangers, D-Shackles, pack washers etc.-HTSteel for Normal Towers MT 6.023 INCLUDED 0 0
111 7000014244 1110 66KV S/C Line 1000015276 73082011 18 Fabrication, galvanising & supply of stubs with cleats for varioustypes of towers and tower extensions(complete) with packwashers excluding supply of bolts & nuts-MS Steel for Normal Towers MT 0.08 INCLUDED 0 0
112 7000014244 1120 66KV S/C Line 1000013393 73082011 18 Fabrication, galvanising & supply of stubs with cleats for varioustypes of towers and tower extensions(complete) with packwashers excluding supply of bolts & nuts-HT Steel for Normal Towers MT 1.112 INCLUDED 0 0
113 7000014244 1130 66KV S/C Line 1000013472 73181500 18 Supply of Hexagonal Bolts & Nuts for towers including Step Bolts, SpringWashers etc. MT 1.422 INCLUDED 0 0
114 7000014244 1140 66KV S/C Line 1000007847 73181500 18 Supply of Bolts & Nuts for Stubs including Spring Washers etc. MT 0.068 INCLUDED 0 0
115 7000014244 1150 66KV S/C Line 1000010003 73082011 18 Supply of Counterpoise type (120 m length) EA 8 INCLUDED 0 0
116 7000014244 1160 66KV S/C Line 1000032563 73082011 18 DANGER PLATE FOR 66 KV EA 8 INCLUDED 0 0
117 7000014244 1170 66KV S/C Line 1000034828 73082011 18 NUMBER PLATE FOR 66 KV TOWER EA 8 INCLUDED 0 0
118 7000014244 1180 66KV S/C Line 1000017508 73082011 18 Phase Plate (Set of three) SET 8 INCLUDED 0 0
119 7000014244 1190 66KV S/C Line 1000006779 73082011 18 Supply of Anti-Climbing Devices ofBarbed Wire Type SET 8 INCLUDED 0 0
120 7000014244 1200 66KV S/C Line 1000030857 76141000 18 ACSR DOG CONDUCTOR KM 5.25 INCLUDED 0 0
121 7000014244 1210 66KV S/C Line 1000034331 85469090 18 COMPOSITE LONGROD INSULATOR - 66KV - 45KN (LENGTH 1160 MM) EA 48 INCLUDED 0 0
122 7000014244 1220 66KV S/C Line 1000034337 73082011 18 SINGLE TENSION STRING-66KV ACSR DOG CONDUCTOR EA 48 INCLUDED 0 0
123 7000014244 1230 66KV S/C Line 1000015512 76169990 18 Mid Span Compression Joint for Conductor-ACSR Dog EA 4 INCLUDED 0 0
124 7000014244 1240 66KV S/C Line 1000018441 76169990 18 Repair Sleeve for Conductor-ACSR Dog EA 2 INCLUDED 0 0
125 7000014244 1250 66KV S/C Line 1000022429 73082011 18 Vibration Damper for Conductor-ACSR Dog EA 48 INCLUDED 0 0
126 7000014244 1300 Spare for OPGw works 1000030947 85447090 18 24 FIBRE (DWSM) OPGW FIBRE OPTIC CABLE (WITH CENTRAL FIBRE OPTIC UNITOF STEEL TUBE DESIGN ) KM 5 INCLUDED 0 0
127 7000014244 1310 Spare for OPGw works 1000020444 82057000 18 Suspension clamp assembly for 24 fibre OPGW EA 44 INCLUDED 0 0
128 7000014244 1320 Spare for OPGw works 1000010558 82057000 18 Dead end Tension clamp for 24 fibre OPGW EA 1 INCLUDED 0 0
129 7000014244 1330 Spare for OPGw works 1000031039 82057000 18 TENSION FITTINGS ASSEMBLY FOR 24F OPGW INCLUDING ALL ACCESSORIES FORJOINT BOX (SPLICING) LOCATION SET 1 INCLUDED 0 0
130 7000014244 1340 Spare for OPGw works 1000017489 82057000 18 Passing Tension clamp for 24 fibre OPGW EA 8 INCLUDED 0 0
131 7000014244 1350 Spare for OPGw works 1000031041 82057000 18 TENSION FITTINGS ASSEMBLY ON SUSPENSION TOWER FOR 24F OPGW INCLUDINGALL ACCESSORIES AT JOINT BOX (SPLICING) LOCATION SET 1 INCLUDED 0 0
132 7000014244 1360 Spare for OPGw works 1000010817 82057000 18 Down Lead clamp Assembly for 24 fibre OPGW EA 13 INCLUDED 0 0
133 7000014244 1370 Spare for OPGw works 1000022417 82057000 18 Vibration Damper for 24 fibre OPGW EA 10 INCLUDED 0 0
134 7000014244 1380 Spare for OPGw works 1000014198 85353090 18 Joint Box for 24 fibre OPGW EA 2 INCLUDED 0 0
135 7000014244 1390 Spare for OPGw works 1000030834 85447090 18 24 FIBRE ADSS KM 5 INCLUDED 0 0
136 7000014244 1400 Spare for OPGw works 1000034328 82057000 18 INSTALLATION HARDWARE SET FOR 24F ARIEL (ADSS) FIBRE OPTIC CABLINGINCLUDING ALL CABLE FITTINGS & ACCESSORIES EXCEPT JOINT BOX. SET 5 INCLUDED 0 0
137 7000014244 1410 Spare for OPGw works 1000014198 85353090 18 Joint Box for 24 fibre OPGW EA 2 INCLUDED 0 0
138 7000014244 1420 Spare for OPGw works 1000037545 85447090 18 24F (DWSM) APPROACH FIBRE OPTIC CABLE KM 2 INCLUDED 0 0
139 7000014244 1430 Spare for OPGw works 1000013927 39269079 28 Installation hardware set for above 24 Fibre, Fibre Optic ApproachCable SET 2 INCLUDED 0 0
Total Ex-Works Price 0.00 0 1 0
Total Type Test charges as per Schedule-7 0.00
Total Ex-works Price including Type Test charges 0.00
Note : # In case the bidder leaves the cell for confirmation of the HSN code and/or GST rate “blank”, the HSN code and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Date : -- Printed Name : 0
Place : 00-Jan-00 Designation : 0
Specification No.: CC-CS/1073-NER/REW-4246/3/G2 Schedule - 2
Package ARP-DMS-05C for distribution works in Arunachal Pradesh under Comprehensive Scheme for Strengthening of Transmission & Distribution system in NER & Sikkim: Intra State - Arunachal Pradesh.
(SCHEDULE OF RATES AND PRICES)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Local Transportation, In-transit Insurance, loading and unloading
All Prices are in Indian Rupees.
SI. No. PR No PR Line Item No Activity Description Material Code Description Unit Quantity Unit Freight, In-transit Insurance, loading & unloading Charges Total Freight, In-transit Insurance, loading & unloading Charges
(I) PKG DMS WORKS: ARP-DMS-05C
1 7000014244 10 Substation Works 1000001109 2.5MVA, 33/11 kV power transformer with Cu winding along with allaccessories and oil EA 16 INCLUDED
2 7000014244 20 Substation Works 1000004936 5MVA, 33/11 kV power transformer with Cu winding along with allaccessories and oil EA 7 INCLUDED
3 7000014244 30 Substation Works 1000022797 Supply of 33 kV , 1250 Amp 25kA 3 phaseVaccum Circuit Breaker with structure(combined structure to facilitatemounting of CT's as per apprd drg)andall accessories as per TS EA 37 INCLUDED
4 7000014244 40 Substation Works 1000002094 36 kV, 630A, 25 KA, 3-Phase DoubleBreak Isolator without E/S EA 53 INCLUDED
5 7000014244 50 Substation Works 1000002095 36 kV, 630A, 25 KA, 3-Phase DoubleBreak Isolator with one E/S EA 14 INCLUDED
6 7000014244 60 Substation Works 1000000001 Supply of 33 kV, 1 phase , 300-150/1-1 Amp Current transformer (longwithall accessories as per TS EA 111 INCLUDED
7 7000014244 70 Substation Works 1000020373 Supply of 30 kV, 1 phase, 10 KA porcelain housing ZnO LA with allaccessories as per TS EA 132 INCLUDED
8 7000014244 80 Substation Works 1000020375 Supply of 9 kV, 1 phase, 10 KA porcelain housing ZnO LA with allaccessories as per TS EA 144 INCLUDED
9 7000014244 90 Substation Works 1000000269 Supply of 33/?3 kV/110 /?3 Volts, 1 phase PT alongwith all accessoriesas per TS EA 111 INCLUDED
10 7000014244 100 Substation Works 1000044608 33 KV SOLID CORE BUS POST INSULATORS, FITTINGS AND ACCESSORIES SET 78 INCLUDED
11 7000014244 110 Substation Works 1000044609 45 KV SOLID CORE BUS POST INSULATORS, FITTINGS AND ACCESSORIES SET 9 INCLUDED
12 7000014244 120 Substation Works 1000028385 100 KVA, 33/0.433 KV, 3 PH, 50 HZ, ONAN, OUTDOOR STATION TRANSFORMERON DOUBLE POLE STRUCTURE ALONG WITH TRANSFORMER OIL AND ALLACCESSORIES AS PER TS. EA 7 INCLUDED
13 7000014244 130 Substation Works 1000022827 Galvanised STEEL TUBULAR POLE 540 MPA, SP64, 12 METER EA 58 INCLUDED
14 7000014244 140 Substation Works 1000044624 GALVANISED STEEL TUBULAR 12 MTS. 540,SP-64 POLE, MADE FROM STEELGRADE E410C EA 6 INCLUDED
15 7000014244 150 Substation Works 1000015954 Fabrication, galvanising and supply of Lattice Structures (MS Steel),to be designed during detailed engineering, for towers, beams andequipment support structure including pack plates / packwashers andgusset plates excluding fasteners and foundation bolts MT 79.02 INCLUDED
16 7000014244 160 Substation Works 1000044621 GALVANISED FABRICATED STRUCTURE FOR 33 KV BUS & LINE GANTRY- GRADE CSTEEL STRUCTURE AS PER IS 2062 MT 8.8 INCLUDED
17 7000014244 170 Substation Works 1000022813 Fabrication and Supply of M.S. Galvanised items- Pole Top Bracket,V-Cross arm, Back Clamps for V-Cross arm , D P Channel, D P Channelclamp, Stay clamps angle, Stay clamps side, D P cross bracing &clamps,Guarding arm etc etc. complete as required. MT 31.82 INCLUDED
18 7000014244 180 Substation Works 1000044622 GALVANISED FABRICATED STRUCTURE FOR STATION TRANSFORMER, DP STRUCTUREFOR OUTGOING 11 KV FEEDERS, PORECLAIN LA, ISOLATOR, BUS COUPLERISOLATOR & BUS POST INSULATOR- GRADE C STEEL STRUCTURE AS PER IS 2062 MT 3.53 INCLUDED
19 7000014244 190 Substation Works 1000022819 nuts,bolts,foundation bolts and washer and other accessories forstructures. MT 12.32 INCLUDED
20 7000014244 200 Substation Works 1000022807 INSULATOR HARDWARE & ACCESSORIES ALL COMPLETE ALONG WITH 70 KN B&SDISC INSULATOR ( ONE SET CONSISTING OF 4NOS DISC INSULATOR) AS PERTECHNICAL SPECIFICATION. SET 186 INCLUDED
21 7000014244 210 Substation Works 1000030867 ACSR WOLF CONDUCTOR KM 1.702 INCLUDED
22 7000014244 220 Substation Works 1000037509 75X8 MS FLAT FOR EARTHING MT 42.56 INCLUDED
23 7000014244 230 Substation Works 1000029996 60X8MM GALVANISED FLAT FOR RAISER MT 6.4 INCLUDED
24 7000014244 240 Substation Works 1000012682 40mm x 3000 mm long GI Pipe earth electrode for earth pit alongwithclamping arrangement to connect GI Wire as per TS EA 236 INCLUDED
25 7000014244 250 Substation Works 1000004302 40 mm MS rod for Main Earthmat M 1400 INCLUDED
26 7000014244 260 Substation Works 1000028395 20 MM DIA., 3000 MM LONG GI ROD AND OTHER ACCESSORIES AS PER TECHNICALSPECIFICATION. SET 238 INCLUDED
27 7000014244 270 Substation Works 1000029987 SUPPLY OF 11 KV, XLPE INSULATED, ARMORED ALUMINIUM CABLE AS PERTS - 3CX400 SQ. MM M 350 INCLUDED
28 7000014244 280 Substation Works 1000029986 SUPPLY OF 11 KV, XLPE INSULATED, ARMORED ALUMINIUM CABLE AS PERTS - 3CX120 SQ. MM M 2050 INCLUDED
29 7000014244 290 Substation Works 1000029995 END TERMINATION KIT SUITABLE FOR TERMINATION IN CABLE BOX ON 11KVSIDE OF TRANSFORMER FOR 3CX400 SQ. MM CABLE SET 7 INCLUDED
30 7000014244 300 Substation Works 1000029994 END TERMINATION KIT SUITABLE FOR TERMINATION IN CABLE BOX ON 11KVSIDE OF TRANSFORMER FOR 3CX120 SQ. MM CABLE SET 16 INCLUDED
31 7000014244 310 Substation Works 1000029993 END TERMINATION KIT SUITABLE FOR TERMINATION IN 11 KV INDOOR VCBPANEL FOR 3CX400 SQ. MM CABLE SET 7 INCLUDED
32 7000014244 320 Substation Works 1000029991 END TERMINATION KIT SUITABLE FOR TERMINATION IN 11 KV INDOOR VCBPANEL FOR 3CX120 SQ. MM CABLE SET 39 INCLUDED
33 7000014244 330 Substation Works 1000029992 OUTDOOR END TERMINATION KIT (REQUIRED AT DOUBLE POLE STRUCTURE ) FOR11 KV 3CX120 SQ. MM. CABLE SET 24 INCLUDED
34 7000014244 340 Substation Works 1000000496 1.1kV grade 3.5Cx50 sqmm Armoured (PVC) Power Cable M 525 INCLUDED
35 7000014244 350 Substation Works 1000000512 1.1kV grade 4Cx16 sqmm (PVC) Power Cable M 1275 INCLUDED
36 7000014244 360 Substation Works 1000000476 1.1kV grade 2Cx10 sqmm Armoured (PVC) Power Cable M 645 INCLUDED
37 7000014244 370 Substation Works 1000000480 1.1kV grade 2Cx2.5 sqmm Control Cable M 2590 INCLUDED
38 7000014244 380 Substation Works 1000000520 1.1kV grade 5Cx2.5 sqmm Control Cable M 8880 INCLUDED
39 7000014244 390 Substation Works 1000000446 1.1kV grade 10Cx2.5 sqmm Control Cable M 4440 INCLUDED
40 7000014244 400 Substation Works 1000000450 1.1kV grade 12Cx2.5 sqmm Control Cable M 700 INCLUDED
41 7000014244 410 Substation Works 1000028408 33KV CONTROL & RELAY PANEL ALONGWITH E/F & O/C RELAYS, MIMIC DIAGRAM,VOLTMETER, AMMETER, ANNUNCIATION WINDOWS WITH ANNUNCIATION RELAYS ANDOTHER COMPONENTS ETC AS PER TS FOR CONTROLLING POWER TRANSFORMER 33 KVVCB WITH STATIC TRI-VECTOR ENERGY METER SET 16 INCLUDED
42 7000014244 420 Substation Works 1000022810 SUPPLY OF 33 KV TRF. C&R PANEL (WITH O/C & E/F PROTECTION ALONGWITHALL OTHER MANDATORY SYSTEM REQUIRED FOR 5 MVA, 33/11 KV TRF) EA 7 INCLUDED
43 7000014244 430 Substation Works 1000028406 33KV CONTROL & RELAY PANEL ALONGWITH E/F & O/C RELAYS, MIMIC DIAGRAM,VOLTMETER, AMMETER, ANNUNCIATION WINDOWS WITH ANNUNCIATION RELAYS ANDOTHER COMPONENTS ETC AS PER TS FOR CONTROLLING 33 KV FEEDER VCB WITHSTATIC TRI-VECTOR ENERGY METER SET 14 INCLUDED
44 7000014244 440 Substation Works 1000022778 Supply of 11 kV, 630 Amp C&R Cum VCBPanel for incoming 11 kV feeder withPT. EA 23 INCLUDED
45 7000014244 450 Substation Works 1000022776 Supply of 11 kV, 630 Amp C&R Cum VCBPanel for 11 kV Bus Coupler. EA 11 INCLUDED
46 7000014244 460 Substation Works 1000022777 Supply of 11 kV, 630 Amp C&R Cum VCBPanel for Out-Going 11 kV feeder EA 25 INCLUDED
47 7000014244 470 Substation Works 1000000571 110V, 150AH, Ni-Cd type Battery Set andall other accessories complete. SET 16 INCLUDED
48 7000014244 480 Substation Works 1000000567 110 V, Float-Cum-Boost Battery Chargerwith full wave, full controlrectification, 50Hz Input Voltage forcharging 110V, 150AH Battery alongwithinbuit DCDB, connectors etc. completeand conection with 110V, 150AH BatterySet and single phase AC input supply. SET 16 INCLUDED
49 7000014244 490 Substation Works 1000004303 415V AC Distribution Board (ACDB) as per Technical Specification SET 16 INCLUDED
50 7000014244 500 Substation Works 1000028787 BAY MARSHELLING KIOSK COMPLETE AS PER TS EA 24 INCLUDED
51 7000014244 510 Substation Works 1000022818 LIGHTING SYSTEM COMPLETE FOR SWITCHYARD INCLUDING MAINGATE &SUBSTATION BOUNDARY AS PER TS EA 7 INCLUDED
52 7000014244 520 Substation Works 1000022817 LIGHTING SYSTEM COMPLETE FOR CONTROL ROOM BUILDING AS PER TS EA 7 INCLUDED
53 7000014244 530 Substation Works 1000029990 CLAMP & CONNECTORS ETC FOR SUB-STATION HAVING 2 NOS. 33/11 KVTRANSFORMERS SET 1 INCLUDED
54 7000014244 540 Substation Works 1000022811 CLAMP & CONNECTORS ETC FOR SUB-STATION HAVING 2 NOS. 33/11 KVTRANSFORMERS, 1 NO. 33 KV LINE SET 4 INCLUDED
55 7000014244 550 Substation Works 1000029989 CLAMP & CONNECTORS ETC FOR SUB-STATION HAVING 2 NOS. 33/11 KVTRANSFORMERS, 2 NOS. 33 KV FEEDER. LOT 2 INCLUDED
56 7000014244 560 Substation Works 1000029988 CLAMP & CONNECTORS ETC FOR 1 NEW 33 KV LINE BAY IN EXISTING S/S LOT 2 INCLUDED
57 7000014244 570 Substation Works 1000033211 CLAMP & CONNECTORS ETC FOR 2 NEW 33 KV LINE BAY IN EXISTING S/S SET 2 INCLUDED
58 7000014244 580 Substation Works 1000033210 CLAMP & CONNECTORS ETC FOR 1 NEW 33/11 KV TRANSFORMER BAY INEXISTING S/S LOT 1 INCLUDED
59 7000014244 590 Substation Works 1000033209 CLAMP & CONNECTORS ETC FOR 1 NEW 33/11 KV TRANSFORMER BAY & 1REPLACEMENT OF EXISTING TRANSFORMER IN EXISTING S/S SET 3 INCLUDED
60 7000014244 600 Substation Works 1000033212 CLAMP & CONNECTORS ETC FOR REPLACEMENT OF 2 EXISTING TRANSFORMER INEXISTING S/S SET 1 INCLUDED
61 7000014244 610 Substation Works 1000022798 33 kV , 400 Amp, 3 phase , verticalmounted AB switch as per TS EA 7 INCLUDED
62 7000014244 620 Substation Works 1000028100 36 kV, 3-Ph Horn Gap Fuse as per Technical Specification EA 7 INCLUDED
63 7000014244 630 Substation Works 1000022782 11 kV , 400 Amp,3 phase , verticalmounted AB switch for Outgoing DP asper TS EA 25 INCLUDED
64 7000014244 640 Substation Works 1000012026 6Kg dry chemical powered type Portable Fire extinguisher EA 7 INCLUDED
65 7000014244 650 Substation Works 1000012022 4.5 kg CO2 type Portable Fire extinguisher EA 7 INCLUDED
66 7000014244 660 Substation Works 1000027449 22.5 kg CO2 type Portable Fire Extinguisher EA 7 INCLUDED
67 7000014244 670 Substation Works 1000025035 Digital IR Measurement Test Kit (2KV -10KV) with all necessary accessoriesas per Technical specification. EA 7 INCLUDED
68 7000014244 680 Substation Works 1000024644 Digital Multimeter for testing EA 14 INCLUDED
69 7000014244 690 Substation Works 1000024639 Digital Earth Tester-Battery (Rechargeable) Operated Earth Resistance/Resistivity Tester EA 7 INCLUDED
70 7000014244 700 Substation Works 1000025500 Supply Stainless Steel oil samplingbottles (one liter capacity) as perTechnical specification EA 14 INCLUDED
71 7000014244 710 Substation Works 1000033187 11 KV DISCHARGE ROD(1 SET OF 3 RODS) SET 7 INCLUDED
72 7000014244 720 Substation Works 1000033199 BATTERY VOLTAGE TESTER EA 14 INCLUDED
73 7000014244 730 Substation Works 1000033192 33 KV DISCHARGE ROD (1 SET OF 3 RODS) SET 7 INCLUDED
74 7000014244 740 33KV Line with ACSR Racoon Conductor 1000030863 ACSR RACOON CONDUCTOR KM 747.58 INCLUDED
75 7000014244 750 33KV Line with ACSR Racoon Conductor 1000022827 Galvanised STEEL TUBULAR POLE 540 MPA, SP64, 12 METER EA 4439 INCLUDED
76 7000014244 760 33KV Line with ACSR Racoon Conductor 1000044624 GALVANISED STEEL TUBULAR 12 MTS. 540,SP-64 POLE, MADE FROM STEELGRADE E410C EA 560 INCLUDED
77 7000014244 770 33KV Line with ACSR Racoon Conductor 1000022825 STEEL TUBULAR POLE 540 MPA, SP76, 14.5 METER EA 504 INCLUDED
78 7000014244 780 33KV Line with ACSR Racoon Conductor 1000044623 GALVANISED STEEL TUBULAR 14.5 MTS. 540,SP-76 POLE, MADE FROM STEELGRADE E410C EA 56 INCLUDED
79 7000014244 790 33KV Line with ACSR Racoon Conductor 1000022813 Fabrication and Supply of M.S. Galvanised items- Pole Top Bracket,V-Cross arm, Back Clamps for V-Cross arm , D P Channel, D P Channelclamp, Stay clamps angle, Stay clamps side, D P cross bracing &clamps,Guarding arm etc etc. complete as required. MT 376.03 INCLUDED
80 7000014244 800 33KV Line with ACSR Racoon Conductor 1000022819 nuts,bolts,foundation bolts and washer and other accessories forstructures. MT 37.6 INCLUDED
81 7000014244 810 33KV Line with ACSR Racoon Conductor 1000022795 33 KV PORCELAIN PIN INSULATOR WITH 900 MM CREEPAGE DISTANCE ALONGWITH10 KN PIN, NUT AND WASHERS COMPLETE AS PER TS SET 14235 INCLUDED
82 7000014244 820 33KV Line with ACSR Racoon Conductor 1000022806 INSULATOR HARDWARE & ACCESSORIES ALL COMPLETE ALONG WITH 70 KN B&SDISC INSULATOR ( ONE SET CONSISTING OF 3 NOS DISC INSULATOR) AS PER TS SET 4158 INCLUDED
83 7000014244 830 33KV Line with ACSR Racoon Conductor 1000022807 INSULATOR HARDWARE & ACCESSORIES ALL COMPLETE ALONG WITH 70 KN B&SDISC INSULATOR ( ONE SET CONSISTING OF 4NOS DISC INSULATOR) AS PERTECHNICAL SPECIFICATION. SET 1782 INCLUDED
84 7000014244 840 33KV Line with ACSR Racoon Conductor 1000022824 PREFORMED INSULATOR BINDINGS (SUITABLE FOR ACSR CONDUCTOR) FOR 33 KVPIN INSULATOR SET 14235 INCLUDED
85 7000014244 850 33KV Line with ACSR Racoon Conductor 1000022796 33 kV Stay set complete including Hardware, Stay wire (7/10 SWG), insulator etc as per TS SET 4780 INCLUDED
86 7000014244 860 33KV Line with ACSR Racoon Conductor 1000022814 GUY STRAIN INSULATORS DESIGNATION 'C' EA 9560 INCLUDED
87 7000014244 870 33KV Line with ACSR Racoon Conductor 1000022805 Stay wire (7/8 SWG) KG 42293.52 INCLUDED
88 7000014244 880 33KV Line with ACSR Racoon Conductor 1000032344 8SWG GI WIRE FOR PROTECTIVE GUARDING & EARTHING AS PER TS KG 70264.33 INCLUDED
89 7000014244 890 33KV Line with ACSR Racoon Conductor 1000012682 40mm x 3000 mm long GI Pipe earth electrode for earth pit alongwithclamping arrangement to connect GI Wire as per TS EA 888 INCLUDED
90 7000014244 900 Highway Crossing 1000001990 33 kV 3Cx300 sq.mm aluminium, armoured XLPE cable M 1200 INCLUDED
91 7000014244 910 Highway Crossing 1000008867 33 kV Outdoor Termination Kit suitable for 33 kV, 3Cx300 sq.mm XLPEcable SET 16 INCLUDED
92 7000014244 920 Highway Crossing 1000022798 33 kV , 400 Amp, 3 phase , verticalmounted AB switch as per TS EA 8 INCLUDED
93 7000014244 930 OPGW Works 1000030947 24 FIBRE (DWSM) OPGW FIBRE OPTIC CABLE (WITH CENTRAL FIBRE OPTIC UNITOF STEEL TUBE DESIGN ) KM 222 INCLUDED
94 7000014244 940 OPGW Works 1000020444 Suspension clamp assembly for 24 fibre OPGW EA 4420 INCLUDED
95 7000014244 950 OPGW Works 1000010558 Dead end Tension clamp for 24 fibre OPGW EA 16 INCLUDED
96 7000014244 960 OPGW Works 1000031039 TENSION FITTINGS ASSEMBLY FOR 24F OPGW INCLUDING ALL ACCESSORIES FORJOINT BOX (SPLICING) LOCATION SET 111 INCLUDED
97 7000014244 970 OPGW Works 1000017489 Passing Tension clamp for 24 fibre OPGW EA 777 INCLUDED
98 7000014244 980 OPGW Works 1000031041 TENSION FITTINGS ASSEMBLY ON SUSPENSION TOWER FOR 24F OPGW INCLUDINGALL ACCESSORIES AT JOINT BOX (SPLICING) LOCATION SET 20 INCLUDED
99 7000014244 990 OPGW Works 1000010817 Down Lead clamp Assembly for 24 fibre OPGW EA 1270 INCLUDED
100 7000014244 1000 OPGW Works 1000022417 Vibration Damper for 24 fibre OPGW EA 50 INCLUDED
101 7000014244 1010 OPGW Works 1000014198 Joint Box for 24 fibre OPGW EA 111 INCLUDED
102 7000014244 1020 OPGW Works 1000030834 24 FIBRE ADSS KM 20 INCLUDED
103 7000014244 1030 OPGW Works 1000034328 INSTALLATION HARDWARE SET FOR 24F ARIEL (ADSS) FIBRE OPTIC CABLINGINCLUDING ALL CABLE FITTINGS & ACCESSORIES EXCEPT JOINT BOX. SET 20 INCLUDED
104 7000014244 1040 OPGW Works 1000014198 Joint Box for 24 fibre OPGW EA 10 INCLUDED
105 7000014244 1050 OPGW Works 1000023470 OPGW Fibre Optic Distribution Panel (FODP): Indoor Type: 48F EA 11 INCLUDED
106 7000014244 1060 OPGW Works 1000023471 OPGW Fibre Optic Distribution Panel (FODP): Indoor Type: 96F EA 3 INCLUDED
107 7000014244 1070 OPGW Works 1000037545 24F (DWSM) APPROACH FIBRE OPTIC CABLE KM 9 INCLUDED
108 7000014244 1080 OPGW Works 1000013927 Installation hardware set for above 24 Fibre, Fibre Optic ApproachCable SET 9 INCLUDED
109 7000014244 1090 66KV S/C Line 1000015274 Fabrication, galvanising & supply of various types of towers & towerparts, tower/leg extensions (complete) excluding step bolt, stubs andbolts & nuts but including hangers, D-Shackles, pack washers etc.-MSSteel for Normal Towers MT 10.413 INCLUDED
110 7000014244 1100 66KV S/C Line 1000013391 Fabrication, galvanising & supply of various types of towers & towerparts, tower/leg extensions (complete) excluding step bolt, stubs andbolts & nuts but including hangers, D-Shackles, pack washers etc.-HTSteel for Normal Towers MT 6.023 INCLUDED
111 7000014244 1110 66KV S/C Line 1000015276 Fabrication, galvanising & supply of stubs with cleats for varioustypes of towers and tower extensions(complete) with packwashers excluding supply of bolts & nuts-MS Steel for Normal Towers MT 0.08 INCLUDED
112 7000014244 1120 66KV S/C Line 1000013393 Fabrication, galvanising & supply of stubs with cleats for varioustypes of towers and tower extensions(complete) with packwashers excluding supply of bolts & nuts-HT Steel for Normal Towers MT 1.112 INCLUDED
113 7000014244 1130 66KV S/C Line 1000013472 Supply of Hexagonal Bolts & Nuts for towers including Step Bolts, SpringWashers etc. MT 1.422 INCLUDED
114 7000014244 1140 66KV S/C Line 1000007847 Supply of Bolts & Nuts for Stubs including Spring Washers etc. MT 0.068 INCLUDED
115 7000014244 1150 66KV S/C Line 1000010003 Supply of Counterpoise type (120 m length) EA 8 INCLUDED
116 7000014244 1160 66KV S/C Line 1000032563 DANGER PLATE FOR 66 KV EA 8 INCLUDED
117 7000014244 1170 66KV S/C Line 1000034828 NUMBER PLATE FOR 66 KV TOWER EA 8 INCLUDED
118 7000014244 1180 66KV S/C Line 1000017508 Phase Plate (Set of three) SET 8 INCLUDED
119 7000014244 1190 66KV S/C Line 1000006779 Supply of Anti-Climbing Devices ofBarbed Wire Type SET 8 INCLUDED
120 7000014244 1200 66KV S/C Line 1000030857 ACSR DOG CONDUCTOR KM 5.25 INCLUDED
121 7000014244 1210 66KV S/C Line 1000034331 COMPOSITE LONGROD INSULATOR - 66KV - 45KN (LENGTH 1160 MM) EA 48 INCLUDED
122 7000014244 1220 66KV S/C Line 1000034337 SINGLE TENSION STRING-66KV ACSR DOG CONDUCTOR EA 48 INCLUDED
123 7000014244 1230 66KV S/C Line 1000015512 Mid Span Compression Joint for Conductor-ACSR Dog EA 4 INCLUDED
124 7000014244 1240 66KV S/C Line 1000018441 Repair Sleeve for Conductor-ACSR Dog EA 2 INCLUDED
125 7000014244 1250 66KV S/C Line 1000022429 Vibration Damper for Conductor-ACSR Dog EA 48 INCLUDED
126 7000014244 1300 Spare for OPGw works 1000030947 24 FIBRE (DWSM) OPGW FIBRE OPTIC CABLE (WITH CENTRAL FIBRE OPTIC UNITOF STEEL TUBE DESIGN ) KM 5 INCLUDED
127 7000014244 1310 Spare for OPGw works 1000020444 Suspension clamp assembly for 24 fibre OPGW EA 44 INCLUDED
128 7000014244 1320 Spare for OPGw works 1000010558 Dead end Tension clamp for 24 fibre OPGW EA 1 INCLUDED
129 7000014244 1330 Spare for OPGw works 1000031039 TENSION FITTINGS ASSEMBLY FOR 24F OPGW INCLUDING ALL ACCESSORIES FORJOINT BOX (SPLICING) LOCATION SET 1 INCLUDED
130 7000014244 1340 Spare for OPGw works 1000017489 Passing Tension clamp for 24 fibre OPGW EA 8 INCLUDED
131 7000014244 1350 Spare for OPGw works 1000031041 TENSION FITTINGS ASSEMBLY ON SUSPENSION TOWER FOR 24F OPGW INCLUDINGALL ACCESSORIES AT JOINT BOX (SPLICING) LOCATION SET 1 INCLUDED
132 7000014244 1360 Spare for OPGw works 1000010817 Down Lead clamp Assembly for 24 fibre OPGW EA 13 INCLUDED
133 7000014244 1370 Spare for OPGw works 1000022417 Vibration Damper for 24 fibre OPGW EA 10 INCLUDED
134 7000014244 1380 Spare for OPGw works 1000014198 Joint Box for 24 fibre OPGW EA 2 INCLUDED
135 7000014244 1390 Spare for OPGw works 1000030834 24 FIBRE ADSS KM 5 INCLUDED
136 7000014244 1400 Spare for OPGw works 1000034328 INSTALLATION HARDWARE SET FOR 24F ARIEL (ADSS) FIBRE OPTIC CABLINGINCLUDING ALL CABLE FITTINGS & ACCESSORIES EXCEPT JOINT BOX. SET 5 INCLUDED
137 7000014244 1410 Spare for OPGw works 1000014198 Joint Box for 24 fibre OPGW EA 2 INCLUDED
138 7000014244 1420 Spare for OPGw works 1000037545 24F (DWSM) APPROACH FIBRE OPTIC CABLE KM 2 INCLUDED
139 7000014244 1430 Spare for OPGw works 1000013927 Installation hardware set for above 24 Fibre, Fibre Optic ApproachCable SET 2 INCLUDED
Total of Schedule-2 0.00
Date : -- Printed Name : 0
Place : 00-Jan-00 Designation : 0
Specification No.: CC-CS/1073-NER/REW-4246/3/G2 Schedule - 3
Package ARP-DMS-05C for distribution works in Arunachal Pradesh under Comprehensive Scheme for Strengthening of Transmission & Distribution system in NER & Sikkim: Intra State - Arunachal Pradesh. As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES ) AS per Percent #REF!
As per lum-sum on Sch-3 0.00%
Bidder’s Name and Address (Lead Partner) : To: As per Percent on Sch-3 #REF!
Contract Services Total Discount #REF!
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Sector-29, Multipackage lum-sum 0.00%
Gurgaon (Haryana) - 122001
Installation Charges : All Prices are in Indian Rupees. Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
SI. No. PR No PR Line Item No Activity Header PR Activity No Activity Description Service Code SAC (Service Accounting Codes) Whether SAC in column ‘8’ is confirmed. If not indicate applicable the SAC # Rate of GST applicable ( in %) Whether rate of GST in column ‘10’ is confirmed. If not indicate applicable rate of GST # Description Unit Quantity Unit Charges Total Charges Unit Erection Charges Total Erection Charges Unit Erection Charges Total Erection Charges
I PKG DMS WORKS: ARP-DMS-05C
1 7000014244 1260 60 10 Substation Works 150000001 998736 18 Installation, testing & commissioning of 2.5 MVA, 33/11 kV transformer along with all accessories complete as per TS SET 16 INCLUDED 0 0 0%
2 7000014244 1260 60 20 Substation Works 150000003 998736 18 Installation, testing & commissioning of 5 MVA, 33/11 kV transformer along with all accessories complete as per TS EA 7 INCLUDED 0 0 5%
3 7000014244 1260 60 30 Substation Works 150000089 995429 18 Dismantling of existing 1/1.6 MVA , 33/11 kV transformer along with all accessories EA 5 INCLUDED 0 0 12%
4 7000014244 1260 60 40 Substation Works 150000092 998736 18 Loading, transporting and unloading 1/1.6 MVA dismantled 33/11 kV transformer alongwith all accessories from location ofdismantling to designated store of DISCOM EA 5 INCLUDED 0 0 18%
5 7000014244 1260 60 50 Substation Works 150000005 998736 18 Erection with structure, testing & commissioning of new 33 kV , 1250 Amp VCBs EA 32 INCLUDED 0 0 28%
6 7000014244 1260 60 60 Substation Works 100007088 995421 18 Dismantling of existing 33 kV, VCB foundation manually/ by mechanical means including stacking of steel bars and disposal ofunserviceable material as per direction of Engineer - in- charge . EA 5 INCLUDED 0 0
7 7000014244 1260 60 70 Substation Works 150000105 995429 18 Replacement of existing 33 kV, VCB by the new 33 kV , 1250 Amp. VCB, testing & commissioning of new VCB as per TS. This includesdismantling of existing VCB structure & erection of new VCB structure on existing/modified foundation (Required if existing VCBneeds to be replaced) EA 5 INCLUDED 0 0
8 7000014244 1260 60 80 Substation Works 150000007 998736 18 Erection alongwith structure , testing & commissioning of new 33 kV , 630 Amp DBCR Isolator with earth switch EA 14 INCLUDED 0 0
9 7000014244 1260 60 90 Substation Works 150000009 998736 18 Erection alongwith structure , testing & commissioning of new 33 kV , 630 Amp DBCR Isolator without earth switch EA 47 INCLUDED 0 0
10 7000014244 1260 60 100 Substation Works 100007089 995421 18 Dismantling of existing 33 kV, isolator structure & erection of new isolator structure on existing/modified foundation(Required ifexisting isolator structure needs to be replaced) . EA 6 INCLUDED 0 0
11 7000014244 1260 60 110 Substation Works 150000118 995429 18 Dismantling of existing 33 kV, isolator structure & erection of new isolator structure on existing/modified foundation (Requiredif existing isolator structure needs to be replaced) EA 6 INCLUDED 0 0
12 7000014244 1260 60 120 Substation Works 150000123 995429 18 Replacement of existing 33 kV, isolator by the new 33 kV , 630 Amp DBCR isolator, testing & commissioning of new isolator (withoutearth switch) as per TS. (Required if existing isolator needs to be replaced) EA 6 INCLUDED 0 0
13 7000014244 1260 60 130 Substation Works 150000010 998736 18 Installation of 33 kV, 1 phase,300-150/1-1 Amp new Current Transformerincluding testing & commissioning (Tobe installed on combined VCB structure) EA 96 INCLUDED 0 0
14 7000014244 1260 60 140 Substation Works 150000112 995429 18 Replacement of existing 33 kV, 1 phase Current transformer by the new 33 kV, 1 phase Current transformer on existing structure,testing & commissioning of new CT as per TS. (Required if CT in existing transformer bay needs to be replaced. It is assumed theexisting CT foundation & structure is adequate. However, if some modification is required in existing structure to match withmounting base of new CT, the bidder will carry out the same at no extra cost to POWERGRID/DISCOM ) EA 15 INCLUDED 0 0
15 7000014244 1260 60 150 Substation Works 150000012 998736 18 Erection alongwith structure 33 kV, 1 phase, 10 KA new porcelain LA including testing & commissioning EA 54 INCLUDED 0 0
16 7000014244 1260 60 160 Substation Works 150000015 998736 18 Installation of 33 kV, 1 phase, 10 KA porcelain LA on line gantry including testing & commissioning for 33 kV line EA 42 INCLUDED 0 0
17 7000014244 1260 60 170 Substation Works 150000124 995429 18 Replacement of existing 30 kV LA by the new 33 kV , 1 phase porcelain LA on existing structure, testing & commissioning of newLA as per TS. (Required if LA in existing transformer bay needs to be replaced. It is assumed the existing LA foundation &structure is adequate. However, if some modification is required in existing structure to match with mounting base of new LA, thebidder will carry out the same at no extra cost to POWERGRID/DISCOM ) EA 15 INCLUDED 0 0
18 7000014244 1260 60 180 Substation Works 150000014 998736 18 Erection alongwith structure 11 kV, 1 phase, 10 KA new porcelain LA including testing & commissioning EA 54 INCLUDED 0 0
19 7000014244 1260 60 190 Substation Works 150000125 995429 18 Replacement of existing 9 kV LA by the new 9 kV , 1 phase porcelain LA on existing structure, testing & commissioning of new LAas per TS. (Required if LA in existing transformer bay needs to be replaced. It is assumed the existing LA foundation & structureis adequate. However, if some modification is required in existing structure to match with mounting base of new LA, the bidder willcarry out the same at no extra cost to POWERGRID/ DISCOM ) EA 15 INCLUDED 0 0
20 7000014244 1260 60 200 Substation Works 150000016 998736 18 Installation [33/Sqrt(3)] kV/[110 /sqrt(3)] Volts, 1 phase PT including testing & commissioning (To be mounted on Bus Gantry) EA 54 INCLUDED 0 0
21 7000014244 1260 60 210 Substation Works 150000115 998736 18 Installation [33/Sqrt(3)] kV/[110 /sqrt(3)] Volts, 1 phase PT alongwith structure including testing & commissioning EA 42 INCLUDED 0 0
22 7000014244 1260 60 220 Substation Works 150000117 995429 18 Replacement of existing PT with new [33/Sqrt(3)] kV/[110 /sqrt(3)] Volts, 1 phase PT on existing structure, testing &commissioning of new PT as per TS. (Required if PT existing PT needs to be replaced. It is assumed the existing PT foundation &structure is adequate. However, if some modification is required in existing structure to match with mounting base of new PT, thebidder will carry out the same at no extra cost to POWERGRID/DISCOM ) EA 15 INCLUDED 0 0
23 7000014244 1260 60 230 Substation Works 150000019 998736 18 Erection alongwith structure 33 kV post insulators assembly comprises 2 nos. of insulators along with all fittings and accessories EA 78 INCLUDED 0 0
24 7000014244 1260 60 240 Substation Works 100006923 995468 18 Erection alongwith structure 45 kV post insulators along with allfittings and accessories . SET 9 INCLUDED 0 0
25 7000014244 1260 60 250 Substation Works 150000154 998736 18 Replacement of existing 33 kV post insulator by new 33 kV post insulator on existing structure, testing & commissioning of newpost insulator as per TS. (Required if existing post insulator needs to be replaced. It is assumed the existing post insulatorfoundation & structure is adequate. However, if some modification is required in existing structure to match with mounting base ofnew post insulator, the bidder will carry out the same at no extra cost to POWERGRID/DISCOM ) EA 15 INCLUDED 0 0
26 7000014244 1260 60 260 Substation Works 150000020 998736 18 Erection, testing & commissioning of100 kVA, 33/0.415 kV, 3 ph, 50 Hz,ONAN, Outdoor Station Transformer ondouble pole steel tubular poleincluding PCC (1:2:4) foundation withfor pole,erection poles and all steelfabricated structures, installationof transformer and all accessories vizAB switch, HG fuse,LA etc complete inall respect EA 7 INCLUDED 0 0
27 7000014244 1260 60 270 Substation Works 150000150 995429 18 Loading, transporting & unloading the old VCB (all 3 poles)/Isolator (all 3 poles)/LA (3 No.)/CT (3No.)/PT (3 No.)/PI (3 No.) alongwith all accessories from site of dismantling to the designated stores of DISCOM (for this purpose any item for all the 3 phase makeone set e.g. 3 PI will make one set, similarly 3 PTs will make another set) SET 24 INCLUDED 0 0
28 7000014244 1260 60 280 Substation Works 150000021 995455 18 Erection of 33 kV bus gantry (consisting of 2 towers & 1 beam) as per approved drawing. This also includes the erection of onespike per gantry for lightning protection and its earthing EA 39 INCLUDED 0 0
29 7000014244 1260 60 290 Substation Works 150000023 995455 18 Erection of 33 kV line gantry (consisting of 2 towers & 1 beam) as per approved drawing. This also includes the erection of onespike per gantry for lightning protection and its earthing EA 6 INCLUDED 0 0
30 7000014244 1260 60 300 Substation Works 150000024 995455 18 Erection of 33 kV line gantry (Total 3 towers & 2 beams) as per approved drawing. This also includes the erection of one spikeper gantry for lightning protection and its earthing EA 4 INCLUDED 0 0
31 7000014244 1260 60 330 Substation Works 150000027 995468 18 Stringing of 33 kV Bus bar, Line bay & transformer bay, as required, including all droppers, jumpers and inter connection withall outdoor equipments using ACSR wolf conductor & insulator with hardware, clamps, connector etc complete in all respect M 1702.8 INCLUDED 0 0
32 7000014244 1260 60 340 Substation Works 150000028 998739 18 Laying of earth mat in switch yard using 75 x 8 mm MS flat as per approved drawing MT 42.56 INCLUDED 0 0
33 7000014244 1260 60 350 Substation Works 150000173 998739 18 Earthing structures/equipment in switch yard using 60 x 8 mm galvanize MS flat for raiser as per approved drawing MT 6.4 INCLUDED 0 0
34 7000014244 1260 60 360 Substation Works 150000030 998739 18 Earthing - using 40 mm dia 3000mm long pipe earth electrodes with test links, RCC pits, CI cover hinged to CI frame, Charcoal, Salt(Alternatively Calcium Bentonite clay & black soil as per TS) and other accessories required for connection with earth mat (including supply of all materials required for treated earth pit except supply items like 40 mm dia GI pipe with fixing arrangement) SET 236 INCLUDED 0 0
35 7000014244 1260 60 370 Substation Works 150000031 998739 18 Earthing - using 20mm dia, 3000mm long GI Rod as earth electrodes and other accessories etc. ( Untreated) to be buried below groundand other accessories required for connection with earth mat ( including supply of all materials required for untreated earth pitexcept supply items like 20 mm dia GI rod with fixing arrangement) SET 238 INCLUDED 0 0
36 7000014244 1260 60 380 Substation Works 150000032 998739 18 DRILLING OF HOLE IN ALL KINDS OF SOIL/BOULDER/ROCK UPTO 50 MTR DEPTH BELOW GROUND LEVEL AT 4 LOCATIONS FOR INSTALLATION OF 40 MM DIAMS ROD USING ANY SUITABLE METHOD AS PER IS STANDARD. THIS INCLUDES SUPPLY OF ALL MATERIALS (EXCLUDING 40 MM DIA MS ROD),EQUIPMENTS, LABOURS, TOOLS ETC REQUIRED FOR BORING AND PROTECTING THE SOIL FROM FALLING BACK INTO THE PIT DURING THE PROCESS ALLCOMPLETE AS PER TECHNICAL SPECIFICATION. THIS INCLUDES INSTALLATION OF 40 MM DIA ROD IN THE PIT AND BACK FILLING THE SAME WITHSOIL FREE FROM FOREIGN MATERIAL. M 1400 INCLUDED 0 0
37 7000014244 1260 60 390 Substation Works 150000033 998739 18 MOBILISATION /TRANSPORTATION CHARGES OF PLANT & MACHINERY,TOOLS & TACKLES,MEN & MATERIALS ETC. LS 7 INCLUDED 0 0
38 7000014244 1260 60 400 Substation Works 150000034 998739 18 LAYING OF 11 KV HT, XLPE CABLE IN GROUND INCLUDING TERMINATION IN CABLE BOX ON POWER TRANSFORMER ,INDOOR 11KV VCB PANEL AND 11KVOUTDOOR DP STRUCTURE- 3 CORE X 120 MM2 SINGLE RUN M 2050 INCLUDED 0 0
39 7000014244 1260 60 410 Substation Works 150000035 998739 18 LAYING OF 11 KV HT, XLPE CABLE IN GROUND INCLUDING TERMINATION IN CABLE BOX ON POWER TRANSFORMER ,INDOOR 11KV VCB PANEL AND 11KVOUTDOOR DP STRUCTURE- 3 CORE X 400 MM2 SINGLE RUN M 350 INCLUDED 0 0
40 7000014244 1260 60 420 Substation Works 150000036 998739 18 Erection of double pole structure usingsteel tubular pole including PCC(1:2:4) foundation for pole, erectionpoles and all steel fabricatedstructures along with allaccessories, viz LA, AB switch etccomplete in all respect for 11kVoutgoing feeder. EA 25 INCLUDED 0 0
41 7000014244 1260 60 430 Substation Works 150000037 998739 18 LAYING OF 1.1 KV GRADE PVC INSULATED, ARMORED 4C X 16 MM2 ALUMINUM CABLE INCLUDING ITS TERMINATION ALONG WITH SUPPLY &INSTALLATION OF ALL ACCESSORIES LIKE DOUBLE COMPRESSION TYPE CABLE GLANDS, FERULES, LUGGING ETC. AS PER APPROVED CABLE SCHEDULE. M 1275 INCLUDED 0 0
42 7000014244 1260 60 440 Substation Works 150000038 998739 18 LAYING OF 1.1 KV GRADE PVC INSULATED, ARMORED 3.5CX50 MM2 ALUMINUM CABLE INCLUDING ITS TERMINATION ALONG WITH SUPPLY &INSTALLATION OF ALL ACCESSORIES LIKE DOUBLE COMPRESSION TYPE CABLE GLANDS, FERULES, LUGGING ETC. AS PER APPROVED CABLE SCHEDULE. M 525 INCLUDED 0 0
43 7000014244 1260 60 450 Substation Works 150000039 998739 18 LAYING OF 1.1 KV GRADE PVC INSULATED, ARMORED 2C X 10 MM2 COPPER CABLE INCLUDING ITS TERMINATION ALONG WITH SUPPLY & INSTALLATIONOF ALL ACCESSORIES LIKE DOUBLE COMPRESSION TYPE CABLE GLANDS, FERULES, LUGGING ETC. AS PER APPROVED CABLE SCHEDULE. M 645 INCLUDED 0 0
44 7000014244 1260 60 460 Substation Works 150000040 998739 18 LAYING OF 1.1 KV GRADE PVC INSULATED, ARMORED 2C X 2.5 MM2 COPPER CABLE INCLUDING ITS TERMINATION ALONG WITH SUPPLY &INSTALLATION OF ALL ACCESSORIES LIKE DOUBLE COMPRESSION TYPE CABLE GLANDS, FERULES, LUGGING ETC. AS PER APPROVED CABLE SCHEDULE. M 2590 INCLUDED 0 0
45 7000014244 1260 60 470 Substation Works 150000041 998739 18 LAYING OF 1.1 KV GRADE PVC INSULATED, ARMORED 5C X 2.5 MM2 COPPER CABLE INCLUDING ITS TERMINATION ALONG WITH SUPPLY &INSTALLATION OF ALL ACCESSORIES LIKE DOUBLE COMPRESSION TYPE CABLE GLANDS, FERULES, LUGGING ETC. AS PER APPROVED CABLE SCHEDULE. M 8880 INCLUDED 0 0
46 7000014244 1260 60 480 Substation Works 150000042 998739 18 LAYING OF 1.1 KV GRADE PVC INSULATED, ARMORED 10C X 2.5 MM2 COPPER CABLE INCLUDING ITS TERMINATION ALONG WITH SUPPLY &INSTALLATION OF ALL ACCESSORIES LIKE DOUBLE COMPRESSION TYPE CABLE GLANDS, FERULES, LUGGING ETC. AS PER APPROVED CABLE SCHEDULE. M 4440 INCLUDED 0 0
47 7000014244 1260 60 490 Substation Works 150000043 998739 18 LAYING OF 1.1 KV GRADE PVC INSULATED, ARMORED 12C X 2.5 MM2 COPPER CABLE INCLUDING ITS TERMINATION ALONG WITH SUPPLY &INSTALLATION OF ALL ACCESSORIES LIKE DOUBLE COMPRESSION TYPE CABLE GLANDS, FERULES, LUGGING ETC. AS PER APPROVED CABLE SCHEDULE. M 700 INCLUDED 0 0
48 7000014244 1260 60 500 Substation Works 150000044 998736 18 Installation (including foundation, as per approved drawing, alongwith supply of all foundation material), testing & commissioningof 33 kV C&R panel for Power trf. EA 19 INCLUDED 0 0
49 7000014244 1260 60 510 Substation Works 150000128 995429 18 Replacement of existing 33 kV Trf. C&R panel with new 33 kV Trf. C&R panel , testing & commissioning of new C&R panel as per TS.(Required if existing C&R panel is not suitable for new trf.)This includes all activities required to complete the work. EA 4 INCLUDED 0 0
50 7000014244 1260 60 520 Substation Works 150000045 998736 18 Installation (including foundation, as per approved drawing, alongwith supply of all foundation material), testing & commissioningof 33 kV C&R panel for 33 kV line EA 14 INCLUDED 0 0
51 7000014244 1260 60 530 Substation Works 150000046 998736 18 INSTALLATION (INCLUDING FOUNDATION, AS PER APPROVED DRAWING, ALONG WITH SUPPLY OF ALL FOUNDATION MATERIAL) , TESTING &COMMISSIONING OF NEW 11 KV, 630 AMP C&R CUM VCB INCOMER FEEDER PANELS AS PER APPROVED DRAWING. THIS INCLUDES ALL INTER-PANELCONNECTIONS (ALL MATERIAL EXCEPT CABLE REQUIRED FOR THIS PURPOSE WILL BE INCLUDED IN THIS ITEM.) EA 19 INCLUDED 0 0
52 7000014244 1260 60 540 Substation Works 150000047 998736 18 INSTALLATION (INCLUDING FOUNDATION, AS PER APPROVED DRAWING, ALONG WITH SUPPLY OF ALL FOUNDATION MATERIAL) , TESTING &COMMISSIONING OF NEW 11 KV, 630 AMP C&R CUM VCB BUS COUPLER PANELS AS PER APPROVED DRAWING. THIS INCLUDES ALL INTER-PANELCONNECTIONS (ALL MATERIAL EXCEPT CABLE REQUIRED FOR THIS PURPOSE WILL BE INCLUDED IN THIS ITEM.) EA 11 INCLUDED 0 0
53 7000014244 1260 60 550 Substation Works 150000048 998736 18 INSTALLATION (INCLUDING FOUNDATION, AS PER APPROVED DRAWING, ALONG WITH SUPPLY OF ALL FOUNDATION MATERIAL) , TESTING &COMMISSIONING OF NEW 11 KV, 630 AMP C&R CUM VCB OUT GOING FEEDER PANELS AS PER APPROVED DRAWING. THIS INCLUDES ALL INTER-PANELCONNECTIONS (ALL MATERIAL EXCEPT CABLE REQUIRED FOR THIS PURPOSE WILL BE INCLUDED IN THIS ITEM.) EA 25 INCLUDED 0 0
54 7000014244 1260 60 560 Substation Works 150000129 995429 18 Replacement of existing 11 kV C&R cum VCB panel with new 11 kV C&R cum VCB panel for in-coming/out-going/Bus Coupler panels ,testing & commissioning of new panel as per TS. (Required if existing C&R cum VCB panel is not suitable). This includes allactivities required to complete the work and to deposit the dismantled panel to the designated store of DISCOM. EA 4 INCLUDED 0 0
55 7000014244 1260 60 570 Substation Works 150000049 998736 18 Installation, testing & commissioningof 110V, 150 AH, Ni-Cd type Battery Setalongwith supply & installation ofaccessories SET 16 INCLUDED 0 0
56 7000014244 1260 60 580 Substation Works 150000050 998736 18 Installation, testing & commissioningof 110V, Float-Cum-Boost BatteryCharger & in-built DCDB alongwithsupply & installation of allaccessories to complete the DC powersystem ( with 110V, 150 AH Battery)as per TS. EA 16 INCLUDED 0 0
57 7000014244 1260 60 590 Substation Works 150000051 998739 18 Installation of (floor/wall mounted including supply of all material required for installation), testing & commissioning of 415Volts AC Distribution board/panel alongwith supply & installation of all accessories to complete auxiliary AC power supply systemas per TS. EA 16 INCLUDED 0 0
58 7000014244 1260 60 600 Substation Works 150000052 998739 18 Installation of Bay Marshalling Kiosk (including foundation, as per approved drawing, along with supply of all foundationmaterial) , testing & commissioning complete with cabling as per TS EA 24 INCLUDED 0 0
59 7000014244 1260 60 610 Substation Works 150000053 998739 18 Installation of all fittings & fixtures as per approved layout complete with cabling, switch boards etc for switchyard LightingSystem , main-gate & substation boundary as per TS SET 7 INCLUDED 0 0
60 7000014244 1260 60 620 Substation Works 150000054 998739 18 Installation of all fittings & fixtures as per approved layout complete with cabling, switch boards etc for control room buildinglightng as per TS SET 7 INCLUDED 0 0
61 7000014244 1260 60 630 Substation Works 100001324 995433 18 Excavation in all types of soil and rock including backfilling disposal etc. for all leads and lifts M3 11035 INCLUDED 0 0
62 7000014244 1260 60 640 Substation Works 100001325 995454 18 Providing and laying of Plain Cement Concrete (PCC) (1:4:8) M3 496 INCLUDED 0 0
63 7000014244 1260 60 650 Substation Works 100001326 995454 18 Providing and laying of Plain Cement Concrete (PCC) (1:2:4) M3 50.167 INCLUDED 0 0
64 7000014244 1260 60 660 Substation Works 100001754 995454 18 Providing and laying of Reinforced Cement Concrete 1:1.5:3 including pre cast, shuttering, Grouting of pockets & underpinning butexcluding steel reinforcement M3 1667 INCLUDED 0 0
65 7000014244 1260 60 670 Substation Works 100001327 995454 18 Providing and laying of Reinforced Cement Concrete M25 mix including pre cast, shuttering, Grouting of pockets & underpinning butexcluding steel reinforcement M3 417 INCLUDED 0 0
66 7000014244 1260 60 680 Substation Works 100001329 995454 18 Steel Reinforcement MT 146 INCLUDED 0 0
67 7000014244 1260 60 690 Substation Works 100001331 995455 18 Misc. Structural steel including rails, embedments, edge protection angles, gratings etc. but excluding the reinforcement steel andsteel for lattice and pipe structures. MT 4.41 INCLUDED 0 0
68 7000014244 1260 60 700 Substation Works 100003114 995454 18 External finishing / painting of fire wall (water proofing cement paint) (DSR 13.44.1) M2 362 INCLUDED 0 0
69 7000014244 1260 60 710 Substation Works 100015232 995441 18 Construction of Septic tank ( Inside dimensions are 2.3 X 1.1 X 1.80 Mtr) and soak pit of 2.5 Mtr Diameter and 3.00 Mtr. High forCRB as per approved drawing and technical specifications EA 7 INCLUDED 0 0
70 7000014244 1260 60 720 Substation Works 100007101 995414 18 Design, engineering and construction of New Control Room Building including indoor cable trench - All civil works as per drawing andspecifications complete, including - brickwork, finishing(external and internal), windows , structural steel etc. However,excavation, PCC,RCC and reinforcement shall be paid separately as per BPS. . M2 1120 INCLUDED 0 0
71 7000014244 1260 60 730 Substation Works 100007102 995414 18 Design, engineering and Modification of Existing Control Room Building including indoor cable trench - All civil works as perdrawing and specifications complete, including - brickwork, finishing(external and internal), windows , structural steel etc.However, excavation, PCC,RCC and reinforcement shall be paid separately as per BPS. . M2 35 INCLUDED 0 0
72 7000014244 1260 60 740 Substation Works 150000055 995432 18 Soil Investigation & Contour Survey of Substation area (New Sub-station) EA 7 INCLUDED 0 0
73 7000014244 1260 60 750 Substation Works 100007091 995454 18 Gravel filling in switchyard area excluding road, trenches etc. Including Antiweed Treatment after neatly levelled and compactedtheground (All completed as per TS) . M3 665 INCLUDED 0 0
74 7000014244 1260 60 760 Substation Works 150000174 995454 18 Construction of Boundary Wall ( including supply of all material) with fixing of MS angle & Barbed Wire fencing all along theboundary wall including supply and fixing of main gate - complete with painting etc all as per approved drawing & TS (Measurementfor this purpose will include length of gate along boundary wall) M 1260 INCLUDED 0 0
75 7000014244 1260 60 770 Substation Works 150000061 995477 18 CONSTRUCTION (INCLUDING SUPPLY OF ALL MATERIAL) ERECTION OF SECURITY FENCING WITH TOE WALL ALONGWITH ONE SWITCHYARD GATE AS PERAPPROVED DRAWINGS & TS. M 385 INCLUDED 0 0
76 7000014244 1260 60 780 Substation Works 100007092 995462 18 Construction of Drainage System in the Substation premises all complete as approved Drawing and Specification. Cross section ofdrainshould be at least 450 X 600 MM. . M 1204 INCLUDED 0 0
77 7000014244 1260 60 790 Substation Works 150000175 995421 18 Construction of 3.75 meter wide RCC Approach Road (including supply of all material) all complete as per approved drawing & TS. M 700 INCLUDED 0 0
78 7000014244 1260 60 800 Substation Works 100007093 995454 18 Construction (including supply of all material) of Cable Trench along with pre-cast RCC Trench Cover, RCC base and wall whereverrequired all complete as approved Drawing & TS outside the control roombuilding. - 0.5 Meter wide Trench. . M 210 INCLUDED 0 0
79 7000014244 1260 60 810 Substation Works 100007094 995454 18 Construction (including supply of all material) of Cable Trench along with pre-cast RCC Trench Cover, RCC base and wall whereverrequired all complete as approved Drawing & TS outside the control roombuilding. - 0.75 Mtrs wide Trench. . M 245 INCLUDED 0 0
80 7000014244 1260 60 820 Substation Works 100007095 995454 18 Construction (including supply of all material) for extension of trench in existing control room required for installation of new C&R panels as per approved drawing - 0.5 Mtrs wide Trench . This item will be executed if no trench is available in control roomforplacing new panels . M 14 INCLUDED 0 0
81 7000014244 1260 60 830 Substation Works 100007096 995454 18 Construction (including supply of all material) for extension of trench in existing control room required for installation of new C&R panels as per approved drawing - 0.75 Mtrs wide Trench . . M 10.5 INCLUDED 0 0
82 7000014244 1260 60 840 Substation Works 150000067 998739 18 Sinking of Tubewell and installation of motor operated submersible pump of suitable capacity and reputed make (All items to besupplied by the contractor. Make of motor/pump to be approved by POWERGRID) EA 7 INCLUDED 0 0
83 7000014244 1260 60 850 Substation Works 150000068 995429 18 Dismantling of existing security fencing & depositing the dismatled material to the designated store of DISCOM including itloading, un-loading & transportation M 49 INCLUDED 0 0
84 7000014244 1260 60 860 Substation Works 100006920 995456 18 Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6coarse sand : 12 graded stone aggregate 20 mm nominal size) uptoplinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) . M3 1400 INCLUDED 0 0
85 7000014244 1260 60 870 Substation Works 100006921 995456 18 Random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up withcement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) at window sills, ceiling level andthe like.:Cement mortar 1:6 (1 cement : 6 coarse sand) . M3 1050 INCLUDED 0 0
86 7000014244 1260 60 880 Substation Works 100015233 995428 18 Providing and fixing in weep holes of retaining walls unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A,including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.:110mm diameter. RM 350 INCLUDED 0 0
87 7000014244 1260 60 890 Substation Works 100007097 995454 18 Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete including construction of 600 mm high and230 mm wide cement concrete (1:3:6) (1 cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) toe wall atthe lowest portion of stone pitching area etc. completed as per theinstruction of Engineer-In-Charge. . M2 700 INCLUDED 0 0
88 7000014244 1260 60 900 Substation Works 100007098 995454 18 Earthwork in excavation and filling in PSS site, all types of soil in open areas/ nallas/ channels, to the required slopes, shapes,levels, elevations and profile, including trimming of bottom and slopes of excavation, bailing out rain (dewatering), pumping,removal of slush, preparing embankments/ marginal banks, loosening, dressing, spreading material in layers not exceeding 200mm, asper directions of Engineer-in-charge, water flooding, compacting to achieve 95 percent consolidation at optimum moisture content,finishing etc. all complete, for all leads within the leveling boundary and all lifts, with all labour, material, tools, tackles andequipment, safeguards and incidentals, as necessary, as per drawings, specification anddirections of Engineer-in-Charge. . M3 7000 INCLUDED 0 0
89 7000014244 1260 60 910 Substation Works 100007099 995454 18 Earthwork in excavation in PSS site, all types of soil in open areas/ nallas/ channels, to the required slopes, shapes, levels,elevations and profile, and disposal of excess excavated earth upto a lead of2.0 KM or as directed by Engineer-in-charge. All kinds of soil . M3 7000 INCLUDED 0 0
90 7000014244 1260 60 920 Substation Works 100007100 995454 18 Earth work in PSS site with ordinary soil (vide classification of soil item - A) obtained from borrow pits free from logs, stumps,roots, rubbish or any other ingredients likely to deteriorate or affect the stability of the site surface including breaking theclods maximum to 60 mm. cube, placing the earth in layers not exceeding 225 mm in loose thickness, rough dressing including cost ofcutting and removing shrubs, roots falling in borrow area all complete as per approved design, as per technical specification. (Mode of Measurement:Sectional measurement after required compaction.) . M3 2100 INCLUDED 0 0
91 7000014244 1270 70 10 33KV Line with ACSR Racoon Conductor 150000069 998344 18 Route survey and pole spotting of 33 KV line as perTS. KM 222 INCLUDED 0 0
92 7000014244 1270 70 20 33KV Line with ACSR Racoon Conductor 150000070 998739 18 Erection of 12 mts. long steel tubular including concrete foundation as per approved drawing & TS. This includes supply offoundation material EA 4999 INCLUDED 0 0
93 7000014244 1270 70 30 33KV Line with ACSR Racoon Conductor 150000152 998739 18 Erection of 14.5 mts. long steel tubular pole(540 SP76) including concrete foundation as per approved drawing & TS. This includessupply of foundation material EA 560 INCLUDED 0 0
94 7000014244 1270 70 40 33KV Line with ACSR Racoon Conductor 150000071 995468 18 Stringing of 3- ph 3-wire 33 kV S/C linewith ACSR Racoon conductor includinginstallation of all fabricatedmaterial, insulators, hardwarefittings, guarding along the line (inbusy area and at various crossings),continous earth wire along the line &jumpering etc. as per TS. This shallalso include supply and installation ofmid span joints, repair sleeves PGclamps, danger plate & anti-climbingdevice. Danger plate & anti-climbingdevice will be installed on allDouble/three/four Pole structuresand poles on both side of variouscrossings. Cost of the Danger plate &anti-climbing device is to be includedin this item. The stringing of one runof Optical Ground Wire (OPGW ) fibreoptic cable including all associatedhardware fittings, its splicing,installation of joint box etc isalso included in this item. KM 203.25 INCLUDED 0 0
95 7000014244 1270 70 50 33KV Line with ACSR Racoon Conductor 150000190 995468 18 Stringing of 3- ph 3-wire 33 kV D/C line with ACSR Racoon conductor including installation of all fabricated material, insulators,hardware fittings, guarding along the line (in busy area and at various crossings), continous earth wire along the line &jumpering etc. as per TS. This shall also include supply and installation of mid span joints, repair sleeves PG clamps, dangerplate & anti-climbing device. Danger plate & anti-climbing device will be installed on all Double/three/four Pole structuresadn poles on both side of various crossings. Cost of the Danger plate & anti-climbing device is to be included in this item. Thestringing of one run of Optical Ground Wire (OPGW ) fibre optic cable including all associated hardware fittings, its splicing,installation of joint box etc is also included in this item. KM 17 INCLUDED 0 0
96 7000014244 1270 70 60 33KV Line with ACSR Racoon Conductor 150000072 995455 18 33 kV Stay Set complete in all respect as per TS SET 4780 INCLUDED 0 0
97 7000014244 1270 70 70 33KV Line with ACSR Racoon Conductor 150000073 998739 18 Earthing of pole using 40 mm dia 3000 mm long pipe as earth electrodes in the pit treated with Charcoal & Salt as per TS. Thisincludes supply of all materials required for completion of job except supply of 40 mm dia GI pipe which is included in supplyportion. SET 888 INCLUDED 0 0
98 7000014244 1270 70 80 33KV Line with ACSR Racoon Conductor 150000074 995455 18 Erection 33 kV railway / road crossing complete in all respect as per TS. This also includes supply of 2 nos. GI Pipes of 1.5times the dia of cable required for two seperate ducts as per TS. EA 4 INCLUDED 0 0
99 7000014244 1280 80 10 OPGW Works 170000540 998336 18 Installation of 24F (DWSM) Aerial (ADSS) Fibre Optic Cable including all hardware fittings & accessories except joint box. KM 20 INCLUDED 0 0
100 7000014244 1280 80 20 OPGW Works 170000265 998716 18 Installation of Joint box above ground (Including Splicing & Testing) : 24 fibres EA 10 INCLUDED 0 0
101 7000014244 1280 80 30 OPGW Works 170000355 998336 18 Fibre Optic Distribution Panel (FODP): Indoor Type: FC Coupling and mounted on ETSI 19 INCH rack or slimline rack: Type 1 (48Fibre) EA 11 INCLUDED 0 0
102 7000014244 1280 80 40 OPGW Works 170000356 998336 18 Fibre Optic Distribution Panel (FODP): Indoor Type: FC Coupling and mounted on ETSI 19" rack or slimline rack: Type 2 (96 Fibre) EA 3 INCLUDED 0 0
103 7000014244 1280 80 50 OPGW Works 100002882 998336 18 Fibre Optic Approach cabling: Including installation hardware like ties/clips/cleats, conduits, ducts, supports, fittings,accessories etc.: 24 Fibre KM 9 INCLUDED 0 0
104 7000014244 1280 80 60 OPGW Works 100003445 998336 18 Survey of Transmission Line (for live line Installation of OPGW) KM 20 INCLUDED 0 0
105 7000014244 1290 90 10 66KV S/C Line 100001244 998342 18 Detailed soil investigation: All kinds of soils except fissured rock and hard rock EA 1 INCLUDED 0 0
106 7000014244 1290 90 20 66KV S/C Line 100001245 998342 18 Detailed soil investigation: Fissured Rock EA 1 INCLUDED 0 0
107 7000014244 1290 90 30 66KV S/C Line 100001248 995455 18 Erection of various types of towers, tower extensions (complete), bolts & nuts, hangers, d-shackles, step bolts, pack washers etc.including tack welding & supply & application of zinc rich paint : Normal towers MT 17.86 INCLUDED 0 0
88 7000014244 1290 90 40 66KV S/C Line 100001252 995432 18 Benching: All kinds of soils except fissured rock,hard rock and sandy soil M3 266.66 INCLUDED 0 0
89 7000014244 1290 90 50 66KV S/C Line 100001253 995432 18 Benching: Fissured Rock M3 213.34 INCLUDED 0 0
90 7000014244 1290 90 60 66KV S/C Line 100001255 995433 18 Excavation : Dry Soil M3 75.33 INCLUDED 0 0
91 7000014244 1290 90 70 66KV S/C Line 100001257 995433 18 Excavation: Dry Fissured Rock M3 97 INCLUDED 0 0
92 7000014244 1290 90 80 66KV S/C Line 100001258 995433 18 Excavation: Wet Fissured Rock M3 43 INCLUDED 0 0
93 7000014244 1290 90 90 66KV S/C Line 100001260 995454 18 Concreting (including all associated works related to foundation not covered in excavation and reinforcemt steel works : concreting(1:1.5:3) M3 35.67 INCLUDED 0 0
94 7000014244 1290 90 100 66KV S/C Line 100001261 995454 18 Concreting (including all associated works related to foundation not covered in excavation and reinforcemt steel works : LeanConcrete (1:3:6) M3 4.67 INCLUDED 0 0
95 7000014244 1290 90 110 66KV S/C Line 100001262 995454 18 Reinforcement Steel : Supply and placement MT 2.47 INCLUDED 0 0
96 7000014244 1290 90 120 66KV S/C Line 100001263 995455 18 Installation of stub including bolts and nuts : For Normal Towers MT 1.26 INCLUDED 0 0
97 7000014244 1290 90 130 66KV S/C Line 100001270 995468 18 Installation of earthing of towers: Counterpoise type (120 m length) EA 8 INCLUDED 0 0
98 7000014244 1290 90 140 66KV S/C Line 100001274 995444 18 Installation of tower accessories : Danger Plate EA 8 INCLUDED 0 0
99 7000014244 1290 90 150 66KV S/C Line 100001275 995444 18 Installation of tower accessories: Number Plate EA 8 INCLUDED 0 0
100 7000014244 1290 90 160 66KV S/C Line 100001276 995444 18 Installation of tower accessories: Phase Plate (Set of three) SET 8 INCLUDED 0 0
101 7000014244 1290 90 170 66KV S/C Line 100001277 995444 18 Installation of tower accessories: Anti-Climbing Devices EA 8 INCLUDED 0 0
102 7000014244 1290 90 180 66KV S/C Line 100004415 995468 18 Installation of insulator strings complete with arcing horns and necessary hardware, installing and stringing of ACSR Dog conductorincluding fixing of conductor accessories, installing and stringing of OPGW including fixing of OPGW accessories for the 66kV S/Cline KM 1.75 INCLUDED 0 0
Total of Schedule-3 0.00 0 1.00 0.00 0.00
# In case the bidder leaves the cell for confirmation of the SAC and/or GST rate “blank”, the SAC and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Date : -- Printed Name : 0
Place : 00-Jan-00 Designation : 0
Specification No.: CC-CS/1073-NER/REW-4246/3/G2 Schedule - 4
Package ARP-DMS-05C for distribution works in Arunachal Pradesh under Comprehensive Scheme for Strengthening of Transmission & Distribution system in NER & Sikkim: Intra State - Arunachal Pradesh.
(SCHEDULE OF RATES AND PRICES )
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Training Charges :
SI. No. PR No Line Item No Activity Header PR Activity No Activity Description Service Code SAC (Service Accounting Codes) Rate of GST applicable ( in %) Description Unit Quantity Unit Charges Total Charges
Total for Training Charges [Total Schedule 4] 0
Date : -- Printed Name : 0
Place : 00-Jan-00 Designation : 0
Specification No.: CC-CS/1073-NER/REW-4246/3/G2 Schedule - 5
Package ARP-DMS-05C for distribution works in Arunachal Pradesh under Comprehensive Scheme for Strengthening of Transmission & Distribution system in NER & Sikkim: Intra State - Arunachal Pradesh.
(SUMMARY OF TAXES & DUTIES )
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Sl. No. Item Nos. Total Price (INR)
1 TOTAL GST on Goods 0.00
Total GST for Supply of Goods (inter-alia including Type Test Charges) between the Contractor and the Employer (identified in Schedule 1') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable.
2 TOTAL GST on Services 0.00
Total GST on Installation Services (indentified in Schedule-3) and Training to be imparted in India (identified in Schedule-4) which are not included in the Installation and Training charges as per the provision of the Bidding Documents, as applicable
GRAND TOTAL [1+2] 0.00
Date : -- Printed Name : 0
Place : 0 Designation : 0
Specification No.: CC-CS/1073-NER/REW-4246/3/G2 Schedule - 5
Package ARP-DMS-05C for distribution works in Arunachal Pradesh under Comprehensive Scheme for Strengthening of Transmission & Distribution system in NER & Sikkim: Intra State - Arunachal Pradesh.
(SUMMARY OF TAXES & DUTIES )
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Sl. No. Item Nos. Total Price (INR)
1 TOTAL GST on Goods 0.00
Total GST for Supply of Goods (inter-alia including Type Test Charges) between the Contractor and the Employer (identified in Schedule 1') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable.
2 TOTAL GST on Services 0.00
Total GST on Installation Services (indentified in Schedule-3) and Training to be imparted in India (identified in Schedule-4) which are not included in the Installation and Training charges as per the provision of the Bidding Documents, as applicable
GRAND TOTAL [1+2] 0.00
Date : -- Printed Name : 0
Place : 0 Designation : 0
Specification No.: CC-CS/1073-NER/REW-4246/3/G2 Schedule - 6
Package ARP-DMS-05C for distribution works in Arunachal Pradesh under Comprehensive Scheme for Strengthening of Transmission & Distribution system in NER & Sikkim: Intra State - Arunachal Pradesh.
(GRAND SUMMARY)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1 0.00
Ex-works price of Plant and Equipment including Type Test Charges
2 TOTAL SCHEDULE NO. 2 0.00
Local Transportation, In-transit Insurance, loading and unloading
3 TOTAL SCHEDULE NO. 3 0.00
Installation Charges
4 TOTAL SCHEDULE NO. 4 - (NOT APPLICABLE) 0.00
Training Charges
5 TOTAL SCHEDULE NO. 5 0.00
Taxes and Duties
6 TOTAL SCHEDULE NO. 7 - (NOT APPLICABLE) 0.00
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2+3+4+5] 0.00
Date : -- Printed Name : 0
Place : 00-Jan-00 Designation : 0
Specification No.: CC-CS/1073-NER/REW-4246/3/G2 Schedule - 6 After Discount
Package ARP-DMS-05C for distribution works in Arunachal Pradesh under Comprehensive Scheme for Strengthening of Transmission & Distribution system in NER & Sikkim: Intra State - Arunachal Pradesh.
(GRAND SUMMARY)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1 0.00
Ex-works price of Plant and Equipment including Type Test Charges
2 TOTAL SCHEDULE NO. 2 0.00
Local Transportation, In-transit Insurance, loading and unloading
3 TOTAL SCHEDULE NO. 3 0.00
Installation Charges
4 TOTAL SCHEDULE NO. 4 - (NOT APPLICABLE) 0.00
Training Charges
5 TOTAL SCHEDULE NO. 5 0.00
Taxes and Duties
6 TOTAL SCHEDULE NO. 7 - (NOT APPLICABLE) 0.00
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2+3+4+5] 0.00
Date : -- Printed Name : 0
Place : 00-Jan-00 Designation : 0
Specification No.: CC-CS/1073-NER/REW-4246/3/G2 Schedule 7
Package ARP-DMS-05C for distribution works in Arunachal Pradesh under Comprehensive Scheme for Strengthening of Transmission & Distribution system in NER & Sikkim: Intra State - Arunachal Pradesh. As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES ) AS per Percent #REF!
As per lum-sum on Sch-7 0.00%
Bidder’s Name and Address (Lead Partner) : To: As per Percent on Sch-7 #REF!
Contract Services Total Discount #REF!
Name : Power Grid Corporation of India Ltd.,
Address : "Saudamini", Plot No.-2
Sector-29, Multipackage Discount 0.0000%
Gurgaon (Haryana) - 122001
Type Test Charges for Type Tests to be conducted:
Sl. No. PR No Line Item No Activity Description Code HSN Code Whether HSN in column ‘ 2 ’ is confirmed. If not indicate applicable the HSN code * Rate of GST applicable ( in %) Whether rate of GST in column ‘4’ is confirmed. If not indicate applicable rate of GST * Description of Test Unit Quantity Unit Charges Total for Type Test charges 0% Total Test Charges After Discount (Rs.) Dis Alert Total Test Charges After MPD (Rs.)
I Extn.of Kanpur S/s incl series Reactor 18%
1 7000009657 310 9000000434 998346 18 TYPE TEST ON AIR CORE REACTOR LOT 1 INCLUDED 0 0 28%
II Extn.of Bhiwani S/s incl Series reactor
2 7000009657 800 9000000434 998346 18 TYPE TEST ON AIR CORE REACTOR LOT 1 INCLUDED 0 0
TOTAL TYPE TEST CHARGES 0 0 1 0
Date : -- Printed Name : 0
Place : 00-Jan-00 Designation : 0
Note : Bidder should indicate the name of test laboratories where type tests are proposed to be conducted
Specification No.: CC-CS/1073-NER/REW-4246/3/G2
Package ARP-DMS-05C for distribution works in Arunachal Pradesh under Comprehensive Scheme for Strengthening of Transmission & Distribution system in NER & Sikkim: Intra State - Arunachal Pradesh. 0 0
(SCHEDULE OF RATES AND PRICES ) 0 0
Bidder’s Name and Address (Lead Partner) :
Sl. No. Whether HSN in column ‘ 2 ’ is confirmed. If not indicate applicable the HSN code * #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
This letter of discount is optional. Bidder may / may not offer any discount.
Specification No.: CC-CS/1073-NER/REW-4246/3/G2 Letter of Discount Schedule 1 0.00
Schedule 2 0.00
LETTER OF DISCOUNT Schedule 3 0.00
To: Schedule 7 0 1 Schedule 4
Contract Services Schedule 1 0.00 1 Schedule 7
Power Grid Corporation of India Ltd., Schedule 2 0.00 1 Total 0.00
"Saudamini", Plot No.-2 Schedule 3 0.00 1
Sector-29, (near IFFCO Chowk) Total Bid Price 0.00 1
Gurgaon (Haryana) - 122001
Subject : Package ARP-DMS-05C for distribution works in Arunachal Pradesh under Comprehensive Scheme for Strengthening of Transmission & Distribution system in NER & Sikkim: Intra State - Arunachal Pradesh.
With reference to the subject tender, we hereby offer unconditional discount on the prices quoted by us as per details given here below : Sch 1 Sch 2 Sch 3 Sch 7 Final Discount Factor Sch-1 Sch-2 Sch-3 Sch-4 Sch-7
1 Discount on lum-sum basis on total price quoted by us without Taxes & Duties. [The discount shall be proportionately applicable on all the items of all the Schdules i.e. Sch-1 (without type test charges), Sch-2, Sch-3, Sch-4 & Sch-7] In Rs. 0.00 0.00 0.00 0.00 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!
2 Discount on percent basis on total price quoted by us without Taxes & Duties. [The discount shall be proportionately applicable on all the items of all the Schdules i.e. Sch-1 (without type test charges), Sch-2 , Sch-3, Sch-4 & Sch-7] In Percent (%) 0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
3 Discount on lum-sum basis on the Schedules as given below : [The discount shall be proportionately applicable on all the relevent items of the respective Schdules.] In Rs.
Schedule-1 : Ex works prices In Rs. 0.00 Schedule-1 : (Direct Only) 0.0000000000% 0.00 X X X X
Schedule-2 : Freight & Insurance In Rs. 0.00 Schedule-2 : Freight & Insurance 0.0000000000% X 0.00 X X X
Schedule-3 : Erection Charges In Rs. 0.00 Schedule-3 : Erection Charges 0.0000000000% X X 0.00 X X
Schedule-4 : Training Charges (NOT APPLICABLE) In Rs. 0.00 X X X 0.00 X
Schedule-7 : Type Test Charges (NOT APPLICABLE) In Rs. Schedule-6 : Type Test Charges 0.0000000000% X X X X 0.00
4 Discount on percent basis on the Schedules as given below : [The discount shall be proportionately applicable on all the relevent items of the respective Schdules.] In Percent (%)
Schedule-1 : Ex works prices In Percent (%) 0 0.00 X X X X
Schedule-2 : Freight & Insurance In Percent (%) 0.00 X 0.00 X X X
Schedule-3 : Erection Charges In Percent (%) 0.00 X X 0.00 X X
Schedule-4 : Training Charges (NOT APPLICABLE) In Percent (%) 0 X X X 0.00 X
Schedule-7 : Type Test Charges (NOT APPLICABLE) In Percent (%) X X X X 0.00
Discount(s) offered at sl. No. 1 to 4 will get displayed and accounted for automatically in the respective items of the Schedules. 0.00 0.00 0.00 0.00
5 We hereby offer Multi-package discount as given below:
Multi-Package Discount(s) offered at sl. No. 5 will not get automatically accounted for in the respective items of the Schedules. The same shall be worked out saparately for evaluation.
Please consider this letter of discount as the integral part of our price bid. 0 0 0 0
Thanking you, we remain, 1 1 1 1 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!
0 0 0 0 #DIV/0! #DIV/0! #DIV/0! #DIV/0! #DIV/0!
Yours faithfully,
For and on behalf of
Date : -- Printed Name : 0
Place : 00-Jan-00 Designation : 0
Details of Octroi
Sl No. Description of Items Amount on which Octroi is applicable Rate of Octroi Octroi
Details of Entry Tax
Sl No. Description of Items Amount on which Entry Tax is applicable Rate of Entry Tax Entry Tax
Details of Other Taxes & Duties
Sl No. Description of Items Amount on which Other Taxes & Duties are applicable Description of Taxes & Duties Rate of Taxes & Duties Amount of Taxes & Duties
Specification No.: CC-CS/1073-NER/REW-4246/3/G2 Bid Form 2nd Envelope Sole Bidder 1 st 1 January
0 2 nd 2 February
BID FORM (Second Envelope) 3 rd 3 March
Bid Proposal Ref. No. 5 th 5 May
Date : -- 6 th #VALUE! 6 June
7 th #VALUE! 7 July
To: 8 th #VALUE! 8 August
9 th #VALUE! 9 September
Power Grid Corporation of India Ltd., 10 th 10 October
"Saudamini", Plot No.-2 11 th 11 November
Sector-29, 12 th 12 December
Gurgaon (Haryana) - 122001 13 th
Name of Contract : Package ARP-DMS-05C for distribution works in Arunachal Pradesh under Comprehensive Scheme for Strengthening of Transmission & Distribution system in NER & Sikkim: Intra State - Arunachal Pradesh. 15 th
Dear Ladies and/or Gentlemen, 16 th
Schedule 1 Plant and Equipment (Including Mandatory Spare Parts) to be supplied, including Type Test Charges. 21 st
Schedule 2 Local Transportation, In-transit Insurance, loading and unloading. 22 th
Schedule 3 Installation Charges. Sole Bidder 23 th
Schedule 4 Training charges for training to be imparted. 24 th
Schedule 5 Taxes and Duties 25 th
Schedule 6 Grand Summary [Schedule 1to 6] 26 th
Schedule 7 Break-up of Type Test Charges for Type Tests to be conducted 27 th
2.5 We declare that items left blank in the Schedules will be deemed to have been included in other items. The TOTAL for each Schedule and the TOTAL of Grand Summary shall be deemed to be the total price for executing the Facilities and sections thereof in complete accordance with the Contract, whether or not each individual item has been priced. 31 st
3.0 We confirm that except as otherwise specifically provided our Bid Prices in this Second Envelope include all taxes, duties, levies and charges as may be assessed on us/our Associate (applicable for Foreign Bidder), our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
3.1 100% of applicable Taxes and Duties i.e GST, which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
3.4 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN , in all the states where the project is located and the states from which we shall make our supply of goods.
4.0 # (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions. 2
5.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of
Date : -- Printed Name : 0
Place : 0 Designation : 0
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2 : Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
Total Ex-Works Price Direct 0.00
Total Ex-Works Price Bought Out 0.00
Total Ex-Works Price 0.00
Total Type Test charges as per Schedule-7 #REF!
Total Ex-works Price including Type Test charges #REF!
Note : Specify amount of Excise Duty, Sales Tax/'VAT and other taxes payable on the transaction between the Contractor and the Employer and octroi/entry tax as applicable for destination site/state on all items of supply including bought-out finished items (to be identified in the Contract), which shall be dispatched directly from the sub-vendor’s works to the Employer’s site (sale-in-transit), separately in Schedule-5. Excise Duty, Sales tax and other levies for all the bought-out items are to be included in the EXW Price (Col. No. 5) only and not to be indicated in Schedule-5.
^ If the item(s) quoted/considered as "Bought-out" in the bid are manufactured at Bidder's works and confirmed to be supplied under “Direct transaction” by the bidder, then the taxes and duties on such items shall be paid/reimbursed by POWERGRID in line with the provisions of Bidding Documents. For this purpose, at the time of award, the Ex-works price (exclusive of taxes & duties) shall be arrived at from the quoted Ex-works price (inclusive of taxes ad duties) by excluding taxes and duties applicable on such items, as on date of Bid opening, in case of supplies from manufacturer proposed in the bid. During contract execution, the taxes and duties on such items shall be paid/reimbursed at actuals, limited to the rates prevailing on date of Bid opening.
Place : Printed Name : --
Total F&I Price (=SUM(I16:I27))
Date : (='Sch-1'!B43)
Place : (='Sch-1'!B44) Printed Name : (='Sch-1'!E44)
Designation : (='Sch-1'!E45)
Total Installaiton Charges #REF!
Date : (='Sch-1'!B43)
Place : (='Sch-1'!B44) Printed Name : (='Sch-1'!E44)
Designation : (='Sch-1'!E45)
Date : (=IF('Sch-1'!B43=0,"", 'Sch-1'!B43)) (="Printed Name : " & IF('Sch-1'!E44=0,"",'Sch-1'!E44))
Place : (=IF('Sch-1'!B44=0,"", 'Sch-1'!B44)) (="Designation : " & IF('Sch-1'!E45=0,"",'Sch-1'!E45))
TOTAL TYPE TEST CHARGES (=SUM(I17:I18))
Date : (='Sch-1'!B43) (="Printed Name : " & 'Sch-1'!E44)
Place : (='Sch-1'!B44) (="Designation : " & 'Sch-1'!E45)
Note : Bidder should indicate the name of test laboratories where type tests are proposed to be conducted
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html
01_First Envelope Attachments and Bid Form-DMS-05C.xls
xls • 4.75 MB
02_Attachment-3_Qualification Requirement data.doc
doc • 0.12 MB
03_Attachment-8_Manufacturer Authorization Form.doc
doc • 0.03 MB
04_Attachment-18_SAFETY PACT-rev1.docx
docx • 0.04 MB
05_Attachment-20_KMP Declaration.doc
doc • 0.04 MB
06_Attachment-21_E-RA Compliance.docx
docx • 0.02 MB
07_Attachment-22_Declaration.docx
docx • 0.03 MB
08_Attachment 23- authorization certifacte issued by Domestci Manufacturer.docx
docx • 0.02 MB
09_Attachemnt-24- Affidavit for self-certifictaion.docx
docx • 0.02 MB
10_attachment 25- certifacte by bidder as per DOE.docx
docx • 0.02 MB
11_Attachemnt-26- Affidavit for self-certifictaion PPP-MII.DOCX
docx • 0.02 MB
12_Attachment 27- certifacte by Auditor PPP-MII.docx
docx • 0.02 MB
13_Attachment 28-Bid securing Declaration.docx
docx • 0.02 MB
14_Second Envelope Price Schedules-DMS-05C.xlsx
xlsx • 0.58 MB
Appendix I _ Guidelines for Approach cable installation.pdf
pdf • 1.27 MB
Appendix_F_1_ TYPE TEST PROCEDURE FOR OPTICAL FIBRE.pdf
pdf • 0.62 MB
Appendix_F_2_ Type Test procedure OPGW Cable.pdf
pdf • 1.52 MB
Appendix_F_3_ OPGW HARDWARE FITTINGS TYPE TEST PROCEDURE.pdf
pdf • 0.49 MB
Appendix_F_4_ GENERAL TYPE TEST PROCEDURE-VIBRATION DAMPER.pdf
pdf • 0.29 MB
Appendix_F_5 Type Test Procedure for Joint Box.pdf
pdf • 0.28 MB
Appendix_H_1 SAT Procedure.pdf
pdf • 1.70 MB
Appendix-A UGFO Specifications.doc
doc • 0.47 MB
Appendix-E-Splicing_guideline.pdf
pdf • 1.02 MB
Appendix-G_1_ FAT Procedure for OPGW.pdf
pdf • 0.52 MB
Appendix-G_2_ FAT Procedure for OPGW Fitting, JB & FODP.pdf
pdf • 0.71 MB
Appendix-G_3 FAT Procedure for Vibration Damper.pdf
pdf • 0.22 MB
Appendix-G_4_ FAT procedure of Approach Cable.pdf
pdf • 0.43 MB
GTR Forms for OPGW manufacturer.docx
docx • 0.03 MB
Section VI - Appendix-B_ DRS.doc
doc • 0.55 MB
Section VI - Chapter-02 Testing requirements-fin.doc
doc • 0.52 MB
Section VI - Chapter-03 Installation requirements-fin.doc
doc • 0.18 MB
Section VI - Chapter-04 Aerial Fibre Optic Cabling requirement-fin.doc
doc • 0.17 MB
Section VI - Chapter-05-Documentation-fin.doc
doc • 0.19 MB
Section VI - Chapter-06-Project Mgmt-fin .doc
doc • 0.20 MB
Section VI- Chapter-01 General & OPGW Cable-fin.doc
doc • 0.29 MB
Section IV Chapter-10 (Fire Protection).doc
doc • 0.13 MB
Section IV Chapter-11 (BMK).doc
doc • 0.13 MB
Section IV Chapter-12(ENERGY METER).doc
doc • 0.22 MB
Section IV Chapter-13 (Cables and Jointing Kit).doc
doc • 0.17 MB
Section IV Chapter-14 ( HG Fuse ).doc
doc • 0.16 MB
Section IV Chapter-15 (Cable laying and Erection).doc
doc • 0.45 MB
Section IV Chapter-16 (Rail Pole & RS Joist).doc
doc • 0.13 MB
Section IV Chapter-17 (PSC Pole).doc
doc • 0.16 MB
Section IV Chapter-18 (Steel tubular poles).doc
doc • 0.16 MB
Section IV Chapter-19 (Hardware Fittings).doc
doc • 0.15 MB
Section IV Chapter-2 (VCB).doc
doc • 0.66 MB
Section IV Chapter-20 (ACSR Conductor).doc
doc • 0.23 MB
Section IV Chapter-21 (G.I Wire for Guarding and Lacing).doc
doc • 0.13 MB
Section IV Chapter-22 (PG clamp).doc
doc • 0.12 MB
Section IV Chapter-23 (Insulator).doc
doc • 0.23 MB
Section IV Chapter-24 (Mid span compression joint & Repair sleeve).doc
doc • 0.34 MB
Section IV Chapter-25 (Stay Set).doc
doc • 0.15 MB
Section IV Chapter-26 (66 kV Tower).doc
doc • 0.40 MB
Section IV Chapter-27 (AB Switch).doc
doc • 0.13 MB
Section IV Chapter-3 (C&R Panel).doc
doc • 0.20 MB
Section IV Chapter-4 (Isolators).doc
doc • 0.17 MB
Section IV Chapter-5 ( Instrument Transformer).doc
doc • 0.16 MB
Section IV Chapter-6 (LA).doc
doc • 0.28 MB
Section IV Chapter-7 (Battery & Battery Charger).doc
doc • 0.20 MB
Section IV Chapter-8 (ACDB & DCDB).doc
doc • 0.15 MB
Section IV Chapter-9 (Station Lighting).doc
doc • 0.22 MB
Section V ( Project Management).doc
doc • 0.30 MB
SLD One transformer.pdf
pdf • 1.11 MB
SLD Two transformer.pdf
pdf • 0.57 MB
APP-II_SFQP Transmission Line, Revision 06.pdf
pdf • 2.80 MB
APP-III_SMQP Rev-5.pdf
pdf • 3.40 MB
INDEX.doc
doc • 0.05 MB
Section I( Introduction and General Technical Requirements).docx
docx • 0.17 MB
Section II (Civil works and Soil Investigation) R1.doc
doc • 2.98 MB
Section III( Construction Details).doc
doc • 0.22 MB
Section IV Chapter-1 (Transformer).doc
doc • 0.32 MB
~$1- IFB.doc
doc • 0.00 MB
~$-Annexure-A (BDS).doc
doc • 0.00 MB
~$-Section - III_BDS.docx
docx • 0.00 MB
01- IFB.doc
doc • 0.12 MB
02-Section - II ITB SSTE S&I Rev 5-DCB-Mjn.pdf
pdf • 1.95 MB
03-Section - III_BDS.docx
docx • 0.08 MB
04-Annexure-A (BDS).doc
doc • 0.10 MB
04-Annexure-B to BDS.docx
docx • 0.03 MB
04-Annexure-C to BDS.docx
docx • 0.03 MB
05-Section - IV GCC -S&I Rev 3-DCB.pdf
pdf • 1.93 MB
06-Section - V_SCC.doc
doc • 0.16 MB
07-Appendix -I to SCC.doc
doc • 0.17 MB
08-Annexure-I to Section-V (SCC).docx
docx • 0.02 MB
09-Sample Forms and Procedures-AIS.doc
doc • 0.57 MB
Bid_Sub_Extn_LETTER.doc
doc • 0.22 MB
Letter for Clarification No-IV.docx
docx • 0.17 MB
Letter for Clarification No-III.docx
docx • 0.17 MB
OBD_EXTN-II_LETTER.docx
docx • 0.16 MB
Letter for Amendment No-II & Clarification No-II.docx
docx • 0.17 MB
OBD_EXTN-I_LETTER.docx
docx • 0.17 MB
Letter for Errata no-I.docx
docx • 0.16 MB
Letter for Amendment No.-I & Clarification No-I.docx
docx • 0.17 MB
link_for_Pre-Bid_meeting.docx
docx • 0.16 MB
Remarks.docx
docx • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .