Loading…
Loading…
Tender ID
Tender Value
₹2.1 Cr
EMD Value
₹2.6 L
Closing Date
28 Jan 2026, 11:00 amClosed
Provision and construction of Limited Height Subways (LHS) in lieu of existing manned level crossings No. CT-29 at km 424/14-16, No. CT-65 at km 473/29-31, No. JB-12 at km 438/14-16, No. CT-42 at km 449/9-11 and at the trespassing location at km 140/29-31 in between various stations/sections of Khurda Road (KUR) Division, including EI works of Siemens make.
ST-OT-LHS-02-KUR-533~ECOR
ST-OT-LHS-02-KUR-533
Open
Works - General
12 Months
Khordha, Odisha
₹0
₹2.6 L
28 Jan 2026
6 Jan 2026
14 Jan 2026
A1-EXECUTION OF SIGNALLING WORKS: RATES ARE INCLUSIVE OF:1.All
A2-EXECUTION OF SIGNALLING WORKS: RATES ARE INCLUSIVE OF:1.All
B1-SUPPLY OF SIGNALLING MATERIALS: RATES ARE INCLUSIVE OF:1.All
B2-SUPPLY OF SIGNALLING MATERIALS: RATES ARE INCLUSIVE OF:1.All
B3-SUPPLY OF SIGNALLING MATERIALS: RATES ARE INCLUSIVE OF:1.All
C -SUPPLY & EXECUTION OF DRAWING WORK : RATES ARE INCLUSIVE
4.Transportation of released materials from one site to another site or store of concerned SSES/(In-
charge) or as advised by Sr.DSTE/KUR.
Item- 1 EXECUTION OF SIGNALLING WORKS
S No. Item Description of Item Unit Qty Rate Amount
KHURDA ROAD DIVISION-S AND T/ECOR
1 1 Installation/Alteration/Phase working, Wiring, Station 2.00 1314621.00 2629242.00
testing and commissioning of complete
Electronic Interlocking System
(Distributed/Centerlized Configuration
System with Hot Stand by feature) supplied
as per Item Nos. 01 of Schedule-B-I including
transportation from Consignee's depot to site
of work. This includes execution of labour
portion, Interface relay wiring, erection of
relay racks, fixing of relays and associated
work in relay room, proper fixing of Operator
VDU Terminals etc (The Relays for interface
relays wiring will be supplied by Railways.
The Contractor shall supply all other
materials required for installation, wiring,
testing and commissioning). NOTE:- 1)
Installation & commissioning of Electronic
Interlocking is as per Section-H , Chapter-08.
2) If it is phase working, other than initial
phase design, supply of application logic
required for phase working should be done
by the Contractor agianst this item. 3) The
work includes manufacture/ fabrication,
supply and installation of SM's console and
side table extension as per site requirement
and as advised by site Engineer to
accomodate VDUs, other S&T equipments
and SM's stationary for operation of VDUs
and execution of day to day work for
operation of trains.
2 2 Factory acceptance test (FAT) with ECoR Station 2.00 700837.00 1401674.00
officials, Only for Subsequent Phase working
not for Initial working.
3 3 Site Acceptance Testing(SAT) with ECoR Station 2.00 723923.00 1447846.00
officials, Only for Subsequent Phase working
not for Initial working.
Schedule A2-EXECUTION OF SIGNALLING WORKS: RATES ARE INCLUSIVE OF:1.All taxes., 2.Supply of
sundry materials like nuts, bolts, washers, sand, stone chips., 3.Transportation of materials to site.,
4.Transportation of released materials from one site to another site or store of concerned SSES/(In-
charge) or as advised by Sr.DSTE/KUR. (Item Directory - Not Applicable)
Item- 2 EXECUTION OF SIGNALLING WORKS
S No. Item Description of Item Unit Qty Rate Amount
1 1 Alteration of existing panel,wiring and testing Station 2.00 42357.40 84714.80
and commissioning of Control
Panel[Operation-cum-IndicationConsole] as
per Specn.No.S/36/87 amendment-2,
complete with termination of cable, painting
and lettering asrequired. Railway will
supplyControl Panel and multi core indoor
cables only. Tender shall supply Dominoes,
buttons, keys,counters, MS Angle/Flat,
Hylumsheet, MS clamps, Bolts andnuts, PVC
pipes, Screws,Sleeves, PVC cables, PVC
pipes,PBT terminals, Fuses, LEDs etcand all
other materials requiredfor the work at his
2 2 Alteration of wiring in existing Relay rack/ CT Numbers 6.00 28281.00 169686.00
rack/composite relay rack. This includes
supply of all types of wires, eyelets, nuts &
bolts, bunching material, ferrules, ARA
terminals, fuses & fuse blockes by the
contractor at his own cost. Lettering &
painting to be done by the contractor at his
own cost. Wire (RDSO Approved Sources) to
be inspected by the representative of
Railway before use.
KHURDA ROAD DIVISION-S AND T/ECOR
3 3 Wiring, testing and commissioning of overall Stn/IBH 3.00 140176.00 420528.00
circuits and ground gears of approved
interlocking arrangement as per approved
circuit diagram and Interlocking plan. This
also includes making corrections/alterations
in As Planned drawings and documents as
per the execution at site. This includes Free
home signal connection at site and SM's
office, telephone connection in the
tents/goomties and any other communication
arrangement for the Non interlocking at the
station or as decided by the representative of
Railway during non interlocking. The
materials required for preparation of Free
Home indication board will be supplied by the
tenderer.This also includes painting and
l e t t e r i n g of gears. Telephone , VHF
Sets/Walkie Talkie sets will be supplied by
railway. Note: In case of IBS : It includes
overall testing and commissioning of IBS and
both the end stations associated with IBS
4 4 Miscellaneous arrangement for NI period Station 3.00 149624.00 448872.00
comprising of Provision of water-proof
temporary goomty/tent at both side of the
station yard and at central panel building.
Each goomties to be furnished with one iron
table, six chairs, emergency light and
mosquito repellantcaps for NI staff, PA
system, crowbar men for operating point and
men for supplying water to tents.
5 5 Dismantling of existing LC gates and related Numbers 3.00 10461.00 31383.00
gears.This includes
dismantling,stacking,accountal of all the
materials including transportation of all the
released materials to the Railway store.
6 6 Transportation, excavation of pit, casting of Numbers 20.00 19438.00 388760.00
foundation, plastering and erection of Steel
Apparatus case (full size) with fixing of E-
Type lock, wiring, cable entry, termination
clamping, filling cable pit with sand, painting
and lettering etc., as per Drg.No.
S&T/CON/SK/16. This includes earth work
and/or masonry work required for securing
the apparatus case as per site condition.
Railway will supply apparatus case with 'E'
type lock only from Railway stores at.
Tenderer will supply all wiring materials, PBT
Terminals, fuses, fuse blocks, bus bars, hylum
sheet ISI mark [6mm thickness], wood plank
board of good quality [minimum 3/4" thick,
Cement and transport all the materials to site
of work at his own cost. The wiring materials
such as wire coils, PBT terminals, fuses, fuse
block, etc. should be used from RDSO
approved sources.
7 7 Alteration of wiring in existing apparatus Numbers 20.00 3583.00 71660.00
cases full/half. This includes supply of all
materials in connection with alteration in
wiring. All the materials shall be supplied by
the contractor at his own cost. This includes
entry of cables, sand filling and masonry
work involved. Lettering and painting to be
done by the contractor at his own cost.
Railway shall supply only relays and relay
KHURDA ROAD DIVISION-S AND T/ECOR
8 8 Transportation of signal posts for multiple Numbers 3.00 20931.00 62793.00
aspect colour light signals, complete with
signal units, bases, ladders and other fittings,
excavation of pit, casting of cement concrete
foundation, plastering as per Drg.No
Con/SK/T/12, erection and fixing of complete
fittings of the 2/3/4 aspect signal/signal posts
including termination of cables, wiring, LED
fixing, signal testing and focusing. Name
plate & marker and all other materials shall
be provided by the contractor at his own
cost. Required cement shall be supplied by
the contractor. Arrangement of Screening to
be provided by the contractor if required as
instructed by site Engineer. Contractor shall
prepare jointly with Railway Engineer at site
and submit Signal Sighting report and Signal
test report as per approved format of
Railway. NOTE: (i) 50 % Payment shall be
released after erection of signal post.
Balance 50 % shall be released after
termination of cable, wiring, painting, testing
& focusing of signal. (ii) If foundation is
available at site 30% of the cost is to be
9 9 Laying of Signalling/4 Quad/ 6 Quad/ Power Kilometre 36.50 24389.00 890198.50
Cable/Telecom cables/ Jelly filled cables of all
sizes in excavated trench, through
GI/RCC/DWC pipes etc. wherever required.
This includes transportation of cables from
the stores to work site and transportation of
empty cable drums with left over cables from
site to the stores at . The length of cable laid
includes the length of cable coil for
termination purpose. NOTE: The cables are to
be carefully handled during loading, un-
loading and transportation to work site. Any
damage found in the cable after final testing,
in view of mishandling of cables, shall be
made good by the Tenderer. Cable should be
maggered before and after laying and
recorded in a register and submitted to the
10 10 Excavation of trenches of following depth and Kilometre 5.50 88821.00 488515.50
width 0.3 Meter detailed below including
clearing of roots and trees etc. for all types of
s o i l . This work also includes covering of
c a b l e s l a i d in trench and backfilling,
ramming, consolidation o f s o i l as well as
disposal of extra soil after cable is laid as
specified in Guidelines on Signalling Cable
laying given by RDSO and any latest circular
i s s u e d by CSTE/ECoR/BBS.Note: Before
refilling of the trenches, the cable laid are to
be tested and recorded for its insulation
value and after satisfaction of site Engineer
the refilling process should start and after
monsoon the route is to be attended for
backfilling the rain cuts, wash out of soils
where ever found. [ii] 1.0 Meter
KHURDA ROAD DIVISION-S AND T/ECOR
11 11 Excavation of trenches of following depth and Kilometre 2.00 71060.00 142120.00
width 0.3 Meter detailed below including
clearing of roots and trees etc. for all types of
s o i l . This work also includes covering of
c a b l e s l a i d in trench and backfilling,
ramming, consolidation o f s o i l as well as
disposal of extra soil after cable is laid as
specified in Guidelines on Signalling Cable
laying given by RDSO and any latest circular
i s s u e d by CSTE/ECoR/BBS.Note: Before
refilling of the trenches, the cable laid are to
be tested and recorded for its insulation
value and after satisfaction of site Engineer
the refilling process should start and after
monsoon the route is to be attended for
backfilling the rain cuts, wash out of soils
where ever found. [iii] 0.8 Meter
12 12 Excavation of trenches of following depth and Kilometre 1.00 106669.00 106669.00
width 0.3 Meter detailed below including
clearing of roots and trees etc. for all types of
s o i l . This work also includes covering of
c a b l e s l a i d in trench and backfilling,
ramming, consolidation o f s o i l as well as
disposal of extra soil after cable is laid as
specified in Guidelines on Signalling Cable
laying given by RDSO and any latest circular
i s s u e d by CSTE/ECoR/BBS.Note: Before
refilling of the trenches, the cable laid are to
be tested and recorded for its insulation
value and after satisfaction of site Engineer
the refilling process should start and after
monsoon the route is to be attended for
backfilling the rain cuts, wash out of soils
where ever found. [i] 1.2 Meter
13 13 Fixing of cable route marker as per drawing Numbers 146.00 706.00 103076.00
in" section-H" at a distance of 100 mtrs.
Along the trench and at places where the
cable route has taken diversion as per
instruction of site Engineer, this includes
casting of foundation at site and fixing of the
marker in the foundation made earlier at site
as per railway directives and specifications,
this includes proper curing of the structure,
All materials required for this like cement,
sand 15 mm chips and steel rod of ISI marks
should be supplied by the tenderer.
14 14 Horizontal direction drilling/boring without Metre 1200.00 1515.72 1818864.00
damage of surface of road/track formation.
The bore shall be 150 mm dia. and shall be
at the proper depth as per site conditions
decided by Enginerin-charge. The ground
level shall be considered ignoring the
bankheight of the bank of the road. The
length of the bore shall be minimum 04 Mtrs
long. This include insertion of different dia.
DWC/GI/HDPE pipes coupling etc as per
direction of Engineer-in-charge. NOTE: The
cost of pipe is not included in this item.
Contractor shall provide all material required
for boring and adequate nos. of labourers for
proper laying of cables in to the bore. Cable
shall be laid cautiously so that it should not
get damage due to rough handling and
pressure on cable.
KHURDA ROAD DIVISION-S AND T/ECOR
15 15 Excavation of trenches in all kinds of soils Metre 290.00 335.00 97150.00
including soft rocky area and clearing of
track etc. to a depth of 1.0 M and width of
0.3 M for track crossing /pucca road/level
crossing gate/platform/station circulating
area or any other place as advised by site
Engineer including transportation and laying
of DWC/RCC/Split RCC/G.I. pipes with or
without coupler. This includes repairing of
track/pucca road/level crossing gate/
platform/station circulating area surface to
original position by ramming and concreting
wherever required soon after the work is
over. DWC/RCC/GI pipes shall be supplied by
the Railway. DWC pipes wherever required
shall be supplied in 6 Mtr. length and shall be
cut to size as per requirement. All other
materials including cement are to be supplied
by the contractor.
16 16 Excavation of trenches including clearing of Metre 660.00 255.00 168300.00
roots of trees etc., in rocky area up to a
depth to be indicated byRailway Engineer at
site as per the site condition [Minimum 0.6
meter] and width 0.3 Mts. at the bottom. This
includes concreting &plastering as per the
instructions of site Engineer andcomplete
backfilling by digging earth from a lead of 30
Mtr. In case 0.8 meter depth or higher is
achieved no concreting is required, otherwise
concreting up to 100 mm thickness should be
done. All materials required for the above
works shall be supplied by the Contractor.
17 17 Cable Duct behind the Relay room and Numbers 6.00 16729.00 100374.00
Goomties of size 1.8 M x1.8 M x 1.2 M to
keep cables entering into it consisting of
brick work of 254 mm thickness of proportion
1:6 with sand filling after coiling of cables.
The top of sand filling covered with
concreting of size 1.30 M x1.30 M and a
depth of 200 mm of proportion 1 :1.5 : 3
outside of the duct should be plastered with
cement mortar 1 : 6 to achieve smooth
finishing. All materials including cement and
chips of size 40mm. and second class bricks
etc. to be supplied by the contractor.
18 18 Cutting of masonary floor/walls at station Numbers 6.00 6108.00 36648.00
building/ signalgoomty/ Gate lodge at a
depth of 0.5 mtr. to 1.0 mtr a t places to be
indicated by site Engineer for entering of
cables inside the building. Only G.I pipes
supplied by Railway and all materials as
clamps, bolts & nuts as instructed by site
Engineer supplied by tenderer. This includes
repairing of masonary floors/walls after the
cables are taken inside. Cement, Sand
required for the work shall be supplied by the
tenderer and also transportation of G.I Pipe
from Store by the tenderer.
KHURDA ROAD DIVISION-S AND T/ECOR
19 19 Trenching and fixing of G.I. pipes of different Metre 110.00 533.00 58630.00
sizes/DWC pipes in hard rocky area up to a
depth of 0.3 M to 0.6 M or at places as per
instructionof site Engineer and concreting [1
:3 : 6] up to height of 100 mm above the
pipes. G.I. pipes with the socket/ DWC pipes
shall be supplied by the Railway. All other
materials required for the works shall be
supplied by the contractor. Note: [1] In case
of girder bridges, G.I. pipes shall be suitably
clamped by the contractor as advised by the
site Engineer. Clamps shall be supplied by
the contractor. [2] The work including
excavation of trenches in hard rock area up
to a depth of 0.3 M to 0.6 M and back filling,
ramming after completion of work where
ever required. [3] In case of concrete bridges
clearing of ballast for laying of pipes and re
arranging the Railway ballast after
completion of work shall be done by the
20 20 Supply, Transportation and Installation of Numbers 30.00 12306.00 369180.00
earth electrode (make TATA or Jindal as per
Rly. practice) including MS flat for signalling
equipments on lever frame, apparatus cases,
signal, relay racks, cable termination rack,
block instrument etc. (supply & installation of
earth electrode as per drawing no.
RE/S&T/DRG/Tender/SK/398/94 for apparatus
cases, signal post & other equipments as per
instruction on earthing of S&T equipment.
Laying of earth lead mild steel flat of size
35mmx6mm and fixing of lead MS flat (make
TATA/Jindal or Similar) to earth electrode and
lever frame, signal post & apparatus cases as
per Drg. No. CORE/S&T/ALD/SK/591/2008,
592/2008 and 593/2008 respectively and
instructions on earthing at S&T equipment
and providing cement enclosure for earth
electrode as per drawing no.
RE/S&T/Sig./Tender/SK/13/85 Alt. A) NOTE:
This includes testing of earth value and
indicating the same on the Earth enclosure
by paint. Inspection by representative of
21 21 Supply, installation, testing and Numbers 8.00 61717.00 493736.00
commissioning of Maintenance free and
permanent earth as per RDSO Specification
No. RDSO/SPN/197 Version 1.0 and Technical
Specification as per section H, Chapter 8,
Inspection by RDSO.
22 22 Fixing of relay bases and wiring, bunching, Per Relay 100.00 783.00 78300.00
fixing of relays, wiring in Old relay
racks/location box and also carrying out any
alteration in existing relay rack duly wiring
and connecting New to old and Old to old
relays by standard wires (RDSO Approved
Sources) as per Circuit diagram. Fuses of
bases, condensers, ND fuses, LED indicator &
its wiring for relay rack. All materials required
for this work will be supplied by the
contractor from RDSO Approved Sources.
Relays with accessories will be supplied by
KHURDA ROAD DIVISION-S AND T/ECOR
23 23 Hiring of JCB machine (in good condition) for Hour 62.00 845.61 52427.82
levelling and dressing ground/dismantling
structures including disposal of debris
through dumpers etc. with contractor's
labour, JCB machine, machine operator, fuel
etc. The contractor shall arrange road permit
for vehicle for all the states of operation as
per instruction of engineer-incharge and
vehicle shall not be more than three years
old. payment shall be made for actual
working hours at site.
24 24 Supply, fitting & fixing of ply board 19mm Sqm 220.00 1684.47 370583.40
thick for cupboard, partition wall etc.
Inspection by representative of Sr.DSTE/KUR.
25 25 Transportation of OFC from the store of to Kilometre 3.00 25563.00 76689.00
work site with care, and pushing/ pulling OFC
through the HDPE pipes sealing of the duct
by simple plugs. The cable is to be laid by
mechanised means. At inaccessible places
where mechanised laying is not possible, the
cable is to be laid manually by pulling
through pre inserted rope. Empty cable
drums with or without leftover cable should
be returned to the store. This also includes
testing of cable drums by OTDR in the store
premises before transportation and
submission of results thereof.
26 26 Transportation of HDPE pipe from the store to Kilometre 3.00 15746.00 47238.00
the work site, laying of the same ( with 4mm
nylon rope,pre inserted inside the HDPE pipe)
in excavated trench/already laid GI/RCC
pipe/tubes,jointing, levelling and end sealing
the pipes. HDPE pipe, couplers and end rope
shall be supplied by the railways, Nylon rope
shall be supplied by the contractor.
27 27 Transportation and jointing (straight through Numbers 32.00 1591.00 50912.00
and derivation) of PIJF/quad cables size TSF-
IV as per Specn No. IRS: TC-31/96 & IRS
30/97. Jointing kits shall be supplied by the
Railway. All other materials shall be supplied
by the tenderer.
28 28 Supply, transportation, and installation of Numbers 14.00 11156.00 156184.00
RCC joint chamber with two piece top cover
and bottom cover with hole for drainage and
cable entry as per drawing No.RCIL/ER/DRG-
02/06 (Section-H). This includes trenching for
joint pit, back filling and ramming of pit after
placing the joint closure and cable loop in the
chamber without causing damage to the
same and consolidation of soilas well as
disposal of excess soil. Inspection by
representative of Sr.DSTE/KUR.
29 29 Supply ,transportation& installation of Optical Numbers 12.00 18027.00 216324.00
Fibre cable joint enclosure and splicing of
OFC (24 Fibre) and testing. OFC splicing shall
be done in presence of Railway
Representative.
KHURDA ROAD DIVISION-S AND T/ECOR
30 30 Transportation, excavation of pit, casting of Numbers 12.00 9742.00 116904.00
foundation, plastering and erection of Steel
Apparatus case (Half size) with fixing of E-
Type lock, wiring, cable entry, termination
clamping, filling cable pit with sand, painting
and lettering etc., as per Drg.No.
S&T/Con/BBS/92/90. This includes earth work
and/or masonry work required for securing
the apparatus case as per site condition.
Railway will supply apparatus case with 'E'
type lock only. Tenderer shall supply all
wiring materials, PBT Terminals, fuses, fuse
blocks, bus bars, hylum sheet ISI mark [6mm
thickness], wood plank board of good quality
[minimum 3/4" thick, cement and any other
materials that are required for the work at his
own cost. Contractor has to transport all the
materials from store at his own cost to the
work site. The wiring materials such as wire
coils, PBT terminals, fuses, fuse block, etc.
should be used from RDSO approved sources.
1) Modification of inside arrangement of
Apparatus cases if required for fixing of
relays/transformers etc. shall be done by the
contractor. Extra shelf, if any, shall be
deposited to the Railway stores by the
contractor. 2) All cables shall be terminated
by providing copper eyelet of suitable size.
Note:-(i) If location box foundation is
available at site 20% of the cost is to be
deducted.(ii) 40% payment shall be released
after erection of location boxes.
31 31 Submission of the final cable route plan after Route 1.70 2111.00 3588.70
the cables are laid and commissioned Kilo
indicating clearly the exact position of the Meter
cable, joints, LB for emergency sockets and (RKM)
other critical materials with reference so
centre line of the nearest track. The final
cable route plan and drawings of the cable
terminations along with all relevant
particulars area to be submitted to the
Railways in original master form as well as 6
32 32 Hiring charges for 7.5 KVA DG Set including Job 6.00 1945.63 11673.78
manpower for operation and maintenance as
per direction of Engineer at site. Only HSD oil
is to be supplied by Railway. Remaining all
other materials including transportation of
the DG set to the site is to be borne by the
contractor. (1 JOB=1 DG set for 1 day)
commissioning & associated wiring for
temporary lighting with 1x28 Watt T5
FL/1X18 W or abo ve indoor type LED T8
fittings with lamp including manpower for
operation and maintenance as per direction
of Engineer at site. All materials including
fitting & wires etc. are to borne by the
contractor. (1 JOB= 1 Light for 1 day).
KHURDA ROAD DIVISION-S AND T/ECOR
34 34 Supply, transportation, erection, and grouting Numbers 6.00 96053.00 576318.00
of Composite Relay Racks / Relay Racks / CT
racks as per Drg.No. SK/DRG/OL/SER/192, SH-
1/2 (for Composite Relay Racks), Drg.No.
SK/DRG/OL/SER/192, SH-2/2 (for Relay Racks)
and Drg.No. S&T/CON/HQ/VSKP/95/92 (for CT
Racks) respectively, including fixing of racks,
PBT terminals 1-Way/6-Way, ND Fuses, Bus
Bars, Eyelets, Hylum strips of required
thickness [12 mm] as per length required at
site, condensers and resistances etc.,
wherever required as per directions of Site
Engineer. Inspection of Composite Racks /
Relay racks/CT racks by Representative of
Railway before use. Tenderer shall supply all
the materials from RDSO approved sources
such as PBT terminals 1-Way/6-Way, ND
Fuses, Fuse blocks, Bus Bars, Eyelets, Hylum
strips (12 mm thicknessn ISI Mark)
condensers and resistances etc., and any
other materials required for the work at his
own cost. Inspection by RITES.
35 35 Wiring and testing of complete Relay Rack / Numbers 6.00 158351.00 950106.00
CT Rack / Composite Relay Rack as per
wiring diagram for maximum number of plug
in type relay & shelf type relays of different
sizes or as directed by Railway Engineers at
site. This includes rack to rack wiring through
MS ladder fixed on the top of the relay rack,
crimping eyelets in the terminals fitted in the
cables termination rack, numbering by
ferrules 2.5 sq. mm, bunching of wires by
bunching Tape/Thread and buttons, painting
and lettering as required. Wiring of the racks
shall be done with PVC wire of size 16/0.2
mm and 3/0.75 mm. Tenderer shall supply all
wires & wiring materials purchased from
RDSO approved sources. Note: 1) Only relay
and relay bases will be supplied by the
Railway. Contractor has to supply all other
materials for the above work and make
arrangement for transportation of materials
supplied by Railway at his own cost. 2) Only
brass screws shall be used for fixing of relay
bases. 3) All types of wires and wiring
materials, eyelets of sizes (make: Dowell's or
similar), ferrules (2.5 sq.mm), resin core
solder, insulating tape, bunching belt &
buttons etc. are to be supplied by the
contractor. Wires will be procured from RDSO
approved sources only. and all other
components will be supplied by the
contractor as per requirement at site.
36 36 Shifting & adjustment of existing analog axle Numbers 6.00 103670.00 622020.00
counters/SSDAC as per the instruction of the
Railway representative.
KHURDA ROAD DIVISION-S AND T/ECOR
37 37 Transportation and fixing of perforated G.I. Metre 36.00 2653.00 95508.00
Pipes on bridges, culverts, drains or in
trenches or any other place as per instruction
of site Engineer with clamps at 1.5 mts.
interval on steel girder bridges or at places
advised by site Engineer. This includes
supplying of G.I. Pipes, 80/100/150 mm dia.
Specn. No. IS:1239/2004, or latest medium
gauge with threaded collars (Make -TATA
/JINDAL) by tenderer. This also includes 100
mm thick concreting on GI pipes as required
and instructed by site Engineer and all other
materials required for the work shall be
supplied by the tenderer. Note: The G.I. pipe
shall be perforated by drilling 7 mm dia holes
length wise in zig-zag manner staggered at a
distance of 300 mm. G.I. Pipes before and
after perforation and bridge fixtures supplied
by the tenderer will be inspected by
representative of Railway before use. The
bridge fixtures will be supplied by tenderer
for fixing of GI pipes on girder bridges only.
(ii) GI pipes of 100 mm Dia;
38 38 Painting, varnishing, numbering, lettering Station 1.00 38057.00 38057.00
and graphiting of all outdoor and indoor
signallingequipments over and above the
initial painting as per instruction of Railway
representative at site. This includes supply of
paints, varnish, graphites and any other
consumables by the contractor.
Schedule B1-SUPPLY OF SIGNALLING MATERIALS: RATES ARE INCLUSIVE OF:1.All taxes., 2.Supply of
sundry materials like nuts, bolts, washers, sand, stone chips., 3.Transportation of materials to site.,
4.Transportation of released materials from one site to another site or store of concerned SSES/(In-
charge) or as advised by Sr.DSTE/KUR. (Item Directory - Not Applicable)
Item- 3 SUPPLY OF SIGNALLING MATERIALS
S No. Item Description of Item Unit Qty Rate Amount
1 1 Supply of Steel Apparatus case 'large Size' as Numbers 20.00 42507.00 850140.00
per Drg. No - CON/SK/1/1/86 and Spec.No.
IRS:S-10/78 (adv) with latest amnd. with "E"
type lock and key of ward No-32 with handle.
Inspection by RITES.
2 2 Supply of 4.6 Mts CLS tubular steel post Numbers 3.00 11663.00 34989.00
specification No. IRS: S-6/81 with latest Amnd
to suit 140 mm dia base. Inspection by the
3 3 Supply of Signal Base 140 mm dia [Type Numbers 3.00 5024.00 15072.00
tube] Drg. No. S-2011/M. Inspection by the
4 4 Supply of double walled corrugated pipe 6 Numbers 50.00 4117.00 205850.00
mtr in length, 120 mm outer dia and 103 mm
inner dia, w i t h one suitable coupler
conforming to RDSO Specification No.
RDSO/SPN/204/2011 Version 1.1 Amdt 1 or
latest for under ground cable protection
.Colour-Orange. Inspection by representative
of Sr.DSTE/KUR. Note: If required, the DWC
pipe shall be supplied split in two halves;
5 5 Supply of Perforated G.I. pipe of 100 mm dia Metre 110.00 1889.00 207790.00
with socket. G.I. pipe of make TATA/JINDAL
shall be as per IS: 1239 part-I/2004
Specification for medium gauge and shall be
perforated by drilling 7 mm dia holes length
wise in zig-zag manner staggered at a
distance of 300 mm. Inspection by
representative of Sr.DSTE/KUR.
KHURDA ROAD DIVISION-S AND T/ECOR
6 6 Supply of Digital multimeter Fluke-287 or Numbers 1.00 114234.00 114234.00
latest higher version with testing lead
complete with case and spare set of
batteries.Inspection by representative of
7 7 Supply of cable route tracer with Integrated Numbers 3.00 451828.60 1355485.80
GPS and Bluetooth, Live GPS data transfer
with Mobile App, through BT, User
configurable frequency and Current direction
indication & 10W Transmitter with minimum
500mA output current and 90V visible on
display, with rechargeable Battery.
Specification as per section H. Make:
adiodetection (RD8200G) or similar. 3 years
OEM warranty. INSPECTION BY RITES.
8 8 Supply of Insulation resistance tester 500V Numbers 3.00 17857.00 53571.00
DC 500 Mega Ohms hand generator type
metal body to Spec. no. IS:2992 make
WACO.Inspection by representative of
9 9 Supply of AC/DC Digital clamp meter Fluke- Numbers 2.00 83661.00 167322.00
376 or similar.Inspection by representative of
10 10 Supply of Permanently lubricated two layer Kilometre 3.00 132496.00 397488.00
type HDPE duct, outer dia 40 mm, inner dia
33 mm with three end plugs and two
couplers for every Km length of pipe in
length of 500 m confirming to RDSO Spec.
No. RDSO/SPN/TC/45/2013.Rev.2.0
Amendment 2.0 or latest. Inspection by
RITES. Note: The HDPE Duct should be pre
inserted with 4 mm nylon rope, inside the
11 11 Supply of Thermo shrink jointing kit for Numbers 26.00 6143.00 159718.00
underground cable as per Specn No. IRS: TC-
77/2012 [Rev.3] Amd 3. (Cable jointing kit
shall be procured from RDSO approved
sources only). Inspection by RDSO.
12 12 Supply of Steel Apparatus case 'Half Size' as Numbers 12.00 25868.00 310416.00
per rg.No.S&T/CON/BBS/92/90 with 'E' type
lock & Key. Ward No. 32. Inspection by RITES
13 13 Supply of Hand Held 200 Khz Digital Numbers 4.00 40592.00 162368.00
Multimeter . MAKE- FLUKE/ YOKOWAGA
.MakeiBrand:- FLUKE 87V. Inspection by
representative of Sr.DSTE/KUR.
14 14 Supply of Signal colour light multi unit as per Numbers 3.00 19082.00 57246.00
specification No: IRS: S-26/64 with latest
amendment as per RDSO Spec No.
RDSO/SPN/153/2011 long range working on
110 V- AC 50 Hz complete 2-Aspect suitable
for 140 mm dia. post as per Drg.No:SA-23003
A/M [Adv]. Inspection by the RITES.
15 15 Supply of Ladder 4.5 meter for CLS post as Numbers 3.00 5745.00 17235.00
per Drg. No. SA: 23150 [Adv] Alt-1,
specification No. IRS: S-10/78 (with latest
Amendment) consisting of ladder base,
platform and guarding, ladder support
complete. Inspection by the RITES.
16 16 Supply of Insulated flexible wirerope steel Kg 500.00 411.87 205935.00
galvanized 7 X 7 strands.Inspection by
representative of Sr.DSTE/KUR.
17 17 Supply of optical fibre joint closure for Numbers 4.00 5669.00 22676.00
straight through joint with modification for 24
fibre as per RDSO Specn No.
RDSO/SPN/TC/68/2014, Revision 0.1 Amnd. 1
or latest.Inspection by representative of
KHURDA ROAD DIVISION-S AND T/ECOR
Schedule B2-SUPPLY OF SIGNALLING MATERIALS: RATES ARE INCLUSIVE OF:1.All taxes., 2.Supply of
sundry materials like nuts, bolts, washers, sand, stone chips., 3.Transportation of materials to site.,
Schedule 4.Transportation of released materials from one site to another site or store of concerned SSES/(In-
charge) or as advised by Sr.DSTE/KUR. (Item Directory - Not Applicable) (Item Directory - Not
Item- 4 SUPPLY OF SIGNALLING MATERIALS
S No. Item Description of Item Unit Qty Rate Amount
1 1 Supply of Relay AC Immune, plug-in type, Numbers 40.00 6428.00 257120.00
style 'QNA1', Neutral line, 24V DC 8F/8B
contacts, Front and back contacts metal to
carbon, complete with plug board, retaining
clip and connectors conforming to
BRS:931A,IRS : S - 60, IRS : S - 34, IRS : S - 23
(As applicable). Interlocking code : ABDGH.
Inspection by RDSO.
2 2 Relay plug in type, Style AC-LED: ALL aspect, Numbers 10.00 7878.00 78780.00
AC lamp proving Relay unit within built
current transformer type, slow release
neutral line relay, 4F/4B contact , front and
back contact metal to carbon shall be
suitable for working in series with 110V AC,
LED signal lamp rated at 15W conforming to
RDSO Spec No- STS/E/Relay/AC lit
LED/signal/09-2002, Amdt. 1, BRS : 941A ,IRS
: S :3 4 &IRS :S : 23 {as applicable}. The
interlocking code for this unit shall be
ABDHK. Inspection by RDSO.
Schedule B3-SUPPLY OF SIGNALLING MATERIALS: RATES ARE INCLUSIVE OF:1.All taxes., 2.Supply of
sundry materials like nuts, bolts, washers, sand, stone chips., 3.Transportation of materials to site.,
Schedule 4.Transportation of released materials from one site to another site or store of concerned SSES/(In-
charge) or as advised by Sr.DSTE/KUR. (Item Directory - Not Applicable) (Item Directory - Not
Applicable) (Item Directory - Not Applicable)
Item- 5 SUPPLY OF SIGNALLING MATERIALS
S No. Item Description of Item Unit Qty Rate Amount
1 1 Supply of LED signal lamps RED aspect for Numbers 5.00 8401.60 42008.00
main color light signals for railway signaling
as per RDSO.( Warranty Period :Upto 60
months from the date of supply). Inspection
2 2 Supply of Integrated LED Signal for YELLOW Numbers 5.00 8401.60 42008.00
aspect as per RDSO Specification No.
RDSO/SPN/199/2010Rev1.1 or latest. (
WarrantyPeriod :Upto 60 months from the
date of supply). Inspection by RDSO.
3 3 Supply of Integrated LED Signal for GREEN Numbers 5.00 9581.60 47908.00
aspect as per RDSO Specification No.
RDSO/SPN/199/2010Rev1.1 or latest. (
WarrantyPeriod :Upto 60 months from the
date of supply). Inspection by RDSO.
Schedule C -SUPPLY & EXECUTION OF DRAWING WORK : RATES ARE INCLUSIVE OF:1.All taxes.,
2.Supply of sundry materials like nuts, bolts, washers, sand, stone chips., 3.Transportation of
Schedule materials to site., 4.Transportation of released materials from one site to another site or store of
concerned SSES/(In-charge) or as advised by Sr.DSTE/KUR. (Item Directory - Not Applicable) (Item
Directory - Not Applicable) (Item Directory - Not Applicable)
Item- 6 SUPPLY & EXECUTION OF DRAWING WORK
S No. Item Description of Item Unit Qty Rate Amount
1 1 Compilation, preparation, correction, Per Page 300.00 25.00 7500.00
updating, printing and supply of Final station
working rules with contractor's stationery,
tools, plants and materials. Note: Final SWR
to be submitted in 2 sets for each station.
KHURDA ROAD DIVISION-S AND T/ECOR
2 2 Printing and supply of approved SWR with Per Page 500.00 4.00 2000.00
contractor's stationery, tools, plants and
materials. Note: Approved SWR to be
submitted in 6 copies for each station.
3 3 Compilation, preparation, printing, binding Per Page 100.00 25.00 2500.00
and supply of Draft station/Gate working
rules both in English and Hindi using MS word
software in computer on the basis of WRD,
RCC and Front plate diagram of Panel/VDU
with contractor's stationery, tools, plants &
4 4 Design of SIP & submission of Three paper Set 1.00 36520.00 36520.00
copies for approval.For a Four-Line Station
5 5 Design of SIP & submission of Three paper Set 1.00 76591.00 76591.00
copies for approval.For a Six-Line Station
6 6 Design of SIP & submission of Three paper Set 1.00 97667.00 97667.00
copies for approval. For a Eight-Line Station
7 7 Design of SWRD & submission of Three paper Set 1.00 17628.00 17628.00
copies for approval.For a Four-Line Station
8 8 Design of SWRD & submission of Three paper Set 1.00 36472.00 36472.00
copies for approval.For a six-Line Station
9 9 Design of SWRD & submission of Three paper Set 1.00 43015.00 43015.00
copies for approval. For a Eight-Line Station
10 10 Design of Cable Route Plan (Distant to Set 1.00 8815.00 8815.00
Distant) & submission of Three paper copies
for approval. For a Four-Line Station
11 11 Design of Cable Route Plan (Distant to Set 1.00 24619.00 24619.00
Distant) & submission of Three paper copies
for approval. For a six-Line Station
12 12 Design of Cable Route Plan (Distant to Set 1.00 29286.00 29286.00
Distant) & submission of Three paper copies
for approval. For a Eight-Line Station or more.
13 13 Supply of Original Tracing of SIP after Numbers 1.00 730.00 730.00
incorporating all the corrections. For a Four-
14 14 Supply of Original Tracing of SIP after Numbers 1.00 866.00 866.00
incorporating all the corrections. For a Six-
15 15 Supply of Original Tracing of SIP after Numbers 1.00 1013.00 1013.00
incorporating all the corrections.Fora Eight-
Line Station or more.
16 16 Supply of Original Tracing of SWRD after Numbers 1.00 528.00 528.00
incorporating all the corrections. For a Four-
17 17 Supply of Original Tracing of SWRD after Numbers 1.00 729.00 729.00
incorporating all the corrections. For a Six-
18 18 Supply of Original Tracing of SWRD after Numbers 1.00 916.00 916.00
incorporating all the corrections. For a Eight-
Line Station or more.
19 19 Supply of Original Tracing of Cable Route Numbers 1.00 1411.00 1411.00
Plan (Distant to Distant) after incorporating
all the corrections. For a Four-Line Station
20 20 Supply of Original Tracing of Cable Route Numbers 1.00 1752.00 1752.00
Plan (Distant to Distant) after incorporating
all the corrections. For a Six-Line Station
21 21 Supply of Original Tracing of Cable Route Numbers 1.00 1977.00 1977.00
Plan (Distant to Distant) after incorporating
all the corrections. For a Eight-Line Station or
22 22 Supply of Original Tracing of Location Box Station 1.00 2644.00 2644.00
Drawings (Including Contact Analysis, Fuse
Particulars etc) after incorporating all the
corrections. For a Four-Line Station
KHURDA ROAD DIVISION-S AND T/ECOR
23 23 Supply of Original Tracing of Location Box Station 1.00 3647.00 3647.00
Drawings (Including Contact Analysis, Fuse
Particulars etc) after incorporating all the
corrections. For a Six-Line Station
24 24 Supply of Original Tracing of Location Box Station 1.00 5491.00 5491.00
Drawings (Including Contact Analysis, Fuse
Particulars etc) after incorporating all the
corrections. For a Eight-Line Station or more.
25 25 Supply of Amonia Print of Approved SIP .For a Numbers 6.00 44.00 264.00
Four-Line Station
26 26 Supply of Amonia Print of Approved SIP .For a Numbers 6.00 46.00 276.00
Six-Line Station
27 27 Supply of Amonia Print of Approved SIP . For Numbers 6.00 46.00 276.00
a Eight-Line Station or more.
28 28 Supply of Amonia Print of Approved Numbers 11.00 44.00 484.00
SWRD.For a Four-Line Station
29 29 Supply of Amonia Print of Approved Numbers 11.00 46.00 506.00
SWRD.For a Six-Line Station
30 30 Supply of Amonia Print of Approved SWRD. Numbers 11.00 46.00 506.00
For a Eight-Line Station or more.
31 31 Supply of Amonia Print of Approved Cable Numbers 6.00 44.00 264.00
Route Plan(Distant to Distant). For a Four-
32 32 Supply of Amonia Print of Approved Cable Numbers 11.00 46.00 506.00
Route Plan(Distant to Distant). For a Eight-
Line Station or more.
33 33 Supply of Amonia Print of Approved Cable Numbers 11.00 46.00 506.00
Route Plan(Distant to Distant). For a Six-Line
Station or more.
34 34 Supply of Amonia Print of Approved Cable Station 6.00 46.00 276.00
Route Plan(mid section). For a Six-Line
35 35 Design of RCC & submission of Three paper Set 1.00 17628.00 17628.00
copies for approval.For a Four-Line Station
36 36 Supply of Original Tracing of RCC after Numbers 1.00 705.00 705.00
incorporating all the corrections. For a Four-
37 37 Supply of Amonia Print of Approved RCC. For Numbers 6.00 44.00 264.00
a Four-Line Station
38 38 Alteration of Existing Circuit Diagrams Sheet 450.00 350.00 157500.00
consisting of the items as mentioned below &
submission of Three paper copies for
approval. (i) Wiring Diagrams, (ii) Relay
Disposition Charts, (iii ) Contact Analysis and
Fuse Particulars, (iv) Panel Termination
Chart, (v) CT Rack Particulars & (vi) Input &
Output Bit Chart for EI Systems
39 39 Design of Cable Distribution Plan & Set 1.00 16589.00 16589.00
submission of Three paper copies for
approval. For a Six -Line Station
40 40 Design of Cable Distribution Plan & Set 1.00 23562.00 23562.00
submission of Three paper copies for
approval.Fora Eight-Line Station or more.
41 41 Supply of Original Tracing of Cable Numbers 1.00 1411.00 1411.00
Distribution Plan after incorporating all the
corrections. For a Four-Line Station
42 42 Supply of Original Tracing of Cable Numbers 1.00 1752.00 1752.00
Distribution Plan after incorporating all the
corrections. For a Six-Line Station
43 43 Supply of Original Tracing of Cable Numbers 1.00 1977.00 1977.00
Distribution Plan after incorporating all the
corrections. For a Four-Line Station
KHURDA ROAD DIVISION-S AND T/ECOR
44 44 Supply of Original Tracing of Goomty Station 2.00 3878.00 7756.00
Drawings (Including Relay Disposition Chart,
Contact Analysis, Fuse Particulars, CT Rack
Particulars and Floor Plan etc) after
incorporating all the corrections. For a Four-
45 45 Supply of Amonia Print of Approved Circuit Station 2.00 4583.00 9166.00
Diagrams consisting of the items as
mentioned below. (i) Wiring Diagrams, (ii)
Relay Disposition Charts, (iii ) Contact
Analysis and Fuse Particulars, (iv) Panel
Termination Chart & (v) CT Rack Particulars.
For a Four-Line Station
46 46 Supply of Amonia Print of Approved Station 2.00 705.00 1410.00
G o o m t y D r a w i n g s ((Including Relay
Disposition Chart, Contact Analysis, Fuse
Particulars, CT Rack Particulars and Floor
Plan etc). For a Four-Line Station
47 47 Supply of Amonia Print of Approved Station 1.00 1464.00 1464.00
G o o m t y D r a w i n g s ((Including Relay
Disposition Chart, Contact Analysis, Fuse
Particulars, CT Rack Particulars and Floor
Plan etc). For a Eight-Line Station or more.
48 48 Alteration of Existing Location Box Drawings Sheet 160.00 451.00 72160.00
(Including Contact Analysis, Fuse Particulars
etc) and submission of Three paper copies for
49 49 Alteration of Existing GoomtyDrawings Sheet 46.00 901.00 41446.00
(Including Relay Disposition Chart, Contact
Analysis, Fuse Particulars, CT Rack
Particulars and Floor Plan etc) and
submission of Three paper copies for
50 50 Supply of Original Tracing in A-3 Size. NOTE:- Sheet 650.00 71.00 46150.00
For Drawings larger than A-3 Size, payment
shall be made in multiples of A-3 Size.
51 51 Supply of Amonia Prints in A-3 Size. NOTE:- Sheet 1850.00 19.00 35150.00
For Drawings larger than A-3 Size, payment
shall be made in multiples of A-3 Size.
52 52 Design of Location Box Drawings (Including Station 1.00 1763.00 1763.00
Contact Analysis, Fuse Particulars etc) and
submission of Three paper copies for
approval. For a Four-Line Station.
53 53 Design of Location Box Drawings (Including Station 1.00 2735.00 2735.00
Contact Analysis, Fuse Particulars etc) and
submission of Three paper copies for
approval. For a Six-Line Station.
54 54 Design of Location Box Drawings (Including Station 1.00 3661.00 3661.00
Contact Analysis, Fuse Particulars etc) and
submission of Three paper copies for
approval. For a Eight-Line Station or more.
55 55 Supply of Amonia Print of Approved Cable Numbers 6.00 44.00 264.00
Distribution Plan. For a Four-Line Station.
56 56 Supply of Amonia Print of Approved Cable Numbers 6.00 46.00 276.00
Distribution Plan.Fora Eight-Line Station or
57 57 Supply of Amonia Print of Approved Cable Numbers 6.00 46.00 276.00
Distribution Plan.For a Six-Line Station or
58 58 Supply of Original Tracing of Circuit Diagrams Station 1.00 26442.00 26442.00
consisting of the items as mentioned below
after incorporating all the corrections. (i)
Wiring Diagrams, (ii) Relay Disposition
Charts, (iii ) Contact Analysis and Fuse
Particulars, (iv) Panel Termination Chart, (v)
CT Rack Particulars & (vi) Input & Output Bit
Chart for EI Systems. For a Four-Line Station
KHURDA ROAD DIVISION-S AND T/ECOR
59 59 Supply of Original Tracing of Circuit Diagrams Station 1.00 33736.00 33736.00
consisting of the items as mentioned below
after incorporating all the corrections. (i)
Wiring Diagrams, (ii) Relay Disposition
Charts, (iii ) Contact Analysis and Fuse
Particulars, (iv) Panel Termination Chart, (v)
CT Rack Particulars & (vi) Input & Output Bit
Chart for EI Systems. For a Six-Line Station
60 60 Supply of Original Tracing of Circuit Diagrams Station 1.00 41184.00 41184.00
consisting of the items as mentioned below
after incorporating all the corrections. (i)
Wiring Diagrams, (ii) Relay Disposition
Charts, (iii ) Contact Analysis and Fuse
Particulars, (iv) Panel Termination Chart, (v)
CT Rack Particulars, (vi) Input & Output Bit
Chart for EI Systems. For a Eight-Line Station
submission of Three paper copies for
approval, For a Six-Line Station
62 62 Design of Track Bonding Plan & submission of Set 1.00 6699.00 6699.00
Three paper copies for approval. For a Four-
63 63 Design of Circuit Diagrams consisting of the Station 1.00 132211.00 132211.00
items as mentioned below & submission of
Three paper copies for approval. (i) Wiring
Diagrams, (ii) Relay Disposition Charts, (iii )
Contact Analysis and Fuse Particulars, (iv)
Panel Termination Chart, (v) CT Rack
Particulars & (vi) Input & Output Bit Chart for
EI Systems. For a Four-Line Station
64 64 Design of Goomty Drawings (Including Relay Station 1.00 3525.00 3525.00
Disposition Chart, Contact Analysis, Fuse
Particulars, CT Rack Particulars and Floor
P l a n etc) and submission of Three paper
copies for approval, For a Four-Line Station.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC2022..pdf
ATTACHMENT
SpecialconditionAnnexure-BB.pdf
ATTACHMENT
NQRJB-12.pdf
ATTACHMENT
RJGRCT-29.pdf
ATTACHMENT
LISTOFANNEXURES.pdf
ATTACHMENT
SPECIALCONDITIONOFCONTRACT.pdf
ATTACHMENT
TENDERFORMSSECONDSHEET.pdf
ATTACHMENT
CHAPTER-8SECTION-H.pdf
ATTACHMENT
TENDERFORMSTHIRDSHEET_2.pdf
ATTACHMENT
TENDERFORMSFIRSTSHEET_1.pdf
ATTACHMENT
SCOPEOFWORK_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .