Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.3 LAccepted-Finance | L1 | Accepted-Finance Being lowest | |
| 2 | L2₹36.2 L+₹93,544.92 (2.65%)Rejected-Finance 34 1 12 2F SAINIK VIHAR DEORI ROAD AGRA UP 282007 | AGRA | UTTAR PRADESH | 282007 | L2 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹66,888
Closing Date
2 Mar 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Maj Dinoop Kumar
GE (W) Agra
PROVN OF CERTAIN SANCTIONED WORKS UNDER AGE E/M (W) OF GE (W) AGRA
2025_MES_696367_1
8012/1061/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Agra
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE (West) Agra
₹66,888
Yes
7 Mar 2025
4 Feb 2025
5 Mar 2025
4 Feb 2025
2 Mar 2025
11 Feb 2025
Amount
Supply and install hi wall Split units indoor/outdoor complete unit with cooling and heating function of capacity 1.5 TR complete , single phase, 50 Hz, 230 volts, compressor High BER rotary, Remote operated and R22 refrigerant gas with minimum 5 star rating complete with cordless remote control and 3 core coppper conductor cable lead upto 1.5 mtrs long of size 4.0 Sqmm and making opening in existing brick work wall for installation of split type AC of capacity 1.5 TR including making opening air tight by providing insulating material such as PUF insulation sheet etc complete all as specified and directed by Engr-in-Charge
Supply and fix ceiling fan, 1200mm sweep, minimum 220 CFM, 230 V, BEE 5 star rated, BLDC (brushless direct current motor ) type complete with standard accessories i.e (three blade, 02 Nos canopy, electronic type modular fan regulator 90 to 100 W, down rod of length 1.5 mtr to 2.0 mtr long, 01 No. fan hock, 02 Nos hanging clamps with rubber real insulator, nuts, lock nuts, bolts, washers, split locking pins etc), double ball bearing, copper wound with synchronous motor, including electrically connecting from ceiling rose to fan connector with 0.5 Sqmm strandard copper conductor 3 core flexible cable cord complete all as specified and directed by Engr-in-Charge.
Supply only desert cooler electric driven (single phase), 230 volts, 50 Hz AC supply of having nominal air flow capacity of minimum 5000 CuM per hour (or nearest higher size) Plastic/ PVC Body with minimum 45 ltr water tank having exhaust fan kit 400 to 450 mm copper bound self supported with universal rolling wheel suitable for a bearing load of desert cooler to esay sifting with 3 core connection cord of size 2.5 sqmm coppler conductor of length minimum 2.0 Mtrs with molded 3 pin plug top of suitable capacity including speed control regulating switch, water circulating pump switch & water level indicator etc complete all as specified and directed by Engr-in-Charge.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4.0 KVA complete all as specified and directed by Engr-in-Charge.
S & F Desert cooler stand of made out of angle iron 25mm x 25mm x 3mm including welding, cutting and grouting on wall as required as per site requirement and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
M&L for point wiring concealed type with 1.50 sqmm PVC FRLS insulated, unsheathed, single core, multi stranded copper conductor cable 1100 volts grade including 1.5 sqmm FRLS PVC insulated unsheathed stranded copper conductor cable as earth continuity conductor drawn in and including rigid PVC conduit of suitable size but not less than 20mm dia with its accessories, sunken type pressed steel terminal box made of 1.2mm thick MS sheet/ anodised steel box painted with one coat of red oxide primer including 3.0 mm thick ISI marked plastic laminated sheet cover for fixing switches/ socket/regulators etc including cutting chases in wall as per standard engineering practice & making good the disturbed surfaces to match with existing for the one Light/Fan/Point controlled by one 1 way switch complete all as specified & directed. NOTE- (i) The quoted rates shall be deemed to be inclusive for cutting chases in brick walls/pillers etc for concealing the conduits to required depth & making good the disturbed surfaces in cement mortar 1:4 including finishing the surface to match with the existing surface.The portion of point wiring at RCC Coloumns/Beams/Ceilings etc shall be in surface conduit of suitable size fixed on surface with using PVC rawl plug and provision of covering terminal boxes/junction boxes of any shape and size with 3 mm thick bakelight laminated sheet fixed with suitable GI screws and cup washers. (ii) Fittings like switches,sockets regulators,lamp holders,light foittings shall be measured and paid for separately under appropriate item of schedule A. (iii)The size of conduits shall be determined on permissible no of runs of wires as specified in SSR part-I clause 19.125 (B).However minimum size of conduit shall be 20 mm dia (medium grade)
Supply and fix switch piano, flush type, single pole, 5/6 Amps one way, 230 volts complete all as specified and directed by Engr-in-Charge
S&F for ceiling rose surface bakelite 62.5 x 25 mm size 3 terminalscomplete all as specified and directed by Engr-in-Charge.
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 4.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 4.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed. Notes:- Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacement, single pole and neutral sheet metal enclosure (AC box) with a two pin & earth plug and socket with one no. MCB SP of capacity 20 Amps 240 volts IK-08 As per IEC 61439-3 complete all as specified and directed by Engr-in-Charge
Supply & fix MCB SP, 6 to 32 Amps, 'C' curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified and directed by Engr-in-Charge.
Supply laying, commisioning & testing cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 sqmm 4 core complete all as specified and directed by Engr-in-Charge
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in soft/loose/ soil for taking out/laying Cable & gradient for CI/GI pipe line and getting out soft/loose soil complete all as specified and as directed by Engineer-in-Charge.
Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick layers complete all as specified and as directed by Engineer-in-Charge.
Removal of excavated material n.exc 50 mtr away and depositing where directed at a level n.exc 1.5 mtr above from starting point complete all as specified and as directed by Engineer-in-Charge.
Supplying and laying un-rainforced precast concrete cable cover LV type-I flat size 250 mm x 150 mm x 40 mm in trenches for protection of cable complete all as specified and directed by Engr-in-Charge.
M&L for sand cushioning dry fine for cable cushioning below and above the cable complete all as directed at site by Engr- in-Charge.
Supply and fixing in replacement GI Pipe 40mm Light grade , for cable protection laid in trench under road or path or fixed on pole or wall with clamps with all fittings complete all as specified and directed by Engr-in-Charge.
Supply, laying and jointing for the 15 mm bore in trenches/on floor/wall with the help of GI Saddle/GI Hook, Galvanized steel tubing medium grade including ISI marked GI fittings, including cutting to reducing length, screwing and connecting with existing line including fix existing connection with required size of Tee or MS clamp with rubber bush complete all as specified and directed by Engr-in-Charge. Note : The rates also include cutting through walls, floor etc and making them good.
All as per item No. 19 above but of size 20 mm dia complete all as specified and directed by Engr-in-Charge.
All as per item No. 19 above but of size 25 mm dia complete all as specified and directed by Engr-in-Charge.
All as per item No. 19 above but of size 40 mm dia complete all as specified and directed by Engr-in-Charge.
All as per item No. 19 above but of size 50 mm dia complete all as specified and directed by Engr-in-Charge.
All as per item No. 19 above but of size 80 mm dia complete all as specified and directed by Engr-in-Charge.
All as per item No. 19 above but of size 100 mm dia complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete (unreinforced) in ground floor and paving n. exc. 15 cm thickness below or above the ground level complete all as specified and directed by Engr-in-Charge
M&L PCC 75 mm thick (1:3:6) type C-1 using 20 mm graded aggregate, plinth protection complete all as specified and directed by Engr-in-Charge.
S&F in repair GM gate valve of size 20mm with iron wheel ISI marked IS-778 screwed down for iron pipe or ferrule including fittings such as union , socket, nipple , check nut etc including cutting of existing GI pipe and fixing properly complete all as specified and directed by Engr-in-Charge.
All as per item No. 28 above but of size 25mm dia complete all as specified and directed by Engr-in-Charge.
All as per item No. 28 above but of size 40 mm dia complete all as specified and directed by Engr-in-Charge.
All as per item No. 28 above but of size 50mm dia complete all as specified and directed by Engr-in-Charge.
Taking up or down for 25 mm bore old kitech pipe and connections complete all as specified and directed by Engr-in-Charge.
All as per item No-32 above but 20 mm bore complete all as specified and directed by Engr-in-Charge.
All as per item No-32 above but 15 mm bore complete all as specified and directed by Engr-in-Charge.
Taking up or down for 40mm bore old GI pipe and connections complete all as specified and directed by Engr-in-Charge.
All as per item No-35 above but 50mm bore complete all as specified and directed by Engr-in-Charge.
All as per item No-35 above but 80mm bore complete all as specified and directed by Engr-in-Charge. .
All as per item No-35 above but 100mm bore complete all as specified and directed by Engr-in-Charge..
M & L in repairs 80mm bore Cast Iron sluice valve both ends flanged PN-1.6 with iron wheel (ISI Marked including nuts, bolts, washer and 3 mm thick rubber insertion sheet complete all as specified and directed by Engr-in-Charge.
All as per item No- 39 above but of size 100mm bore complete all as specified and directed by Engr-in-Charge.
S&F Ball valves ISI marked, 20 mm dia high pressure of PTMT with epoxy coated alumium rod and high density plastic ball screwed for iron pipe (minimum weight 210 Gm) complete all as specified and directed by Engr-in-Charge..
S&F in repairs circular cover for water storage tank, any capacity made out of 1 mm thick GI sheet PVC water storage tank fix with suitable screws (indoor to protact monkey menance) design and size as per sample kept in GE office or as approved by Engr-in-Charge complete all as specified.
M&L for brick work with old size sub class 'B' brick straight or curved on plan, exc. 6M mean radius in cement mortor 1:6 for repairing of valve pit/disturbed wall of well complete all as specified and directed by Engr-in-Charge.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces of wall in cement mortar 1:6 complete all as specified and directed by Engr-in-Charge.
M&L for PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete, complete all as specified and directed by Engr-in-Charge.
M&L for boring of holes under road, pavement, hard standing by trenchless technology using necessary machinery and labour for laying underground pipe GI/DI up to size 300mm complete all as specified and directed at site. Note : Pipes will be measured and paid separately.
M & L for road cutting for laying of pipe line and making good after laying to match with surrounding area with PCC 1:2:4 type B-1 using 20 mm graded stone aggregate for a depth of 30 cm from top and balance portion shall be filled with approved earth complete all as specified and directed by Engr-in-Charge.
M&L for Mild steel, plain, black sheet 1.25mm thick in hearths; covering to door shutters; covering to door chowkats (frames); chullah hoods; water tanks; water troughs; ducts; urinal troughs and funnels, Wall Pit etc. cut to size edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required complete all as specified and directed by Engr-in-Charge..
M/S OM Enterprises (BID ID -3249269)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .