Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.0 LAccepted-AOC AT PO SURYA NAGAR HATATOTA TALCHER DIST ANGUL ODISHA PIN 759100 | TALCHER | ANGUL | ODISHA | 759100 | L1 | Accepted-AOC techno-commercially eligible L1 bidder | |
| 2 | Rejected-Technical AT FCI LAXMI BAZAR TALCHER DIST ANGUL ODISHA | TALCHER | ANGUL | ODISHA | 759117 | - | Rejected-Technical REJECTED FOR NOT BEING L1 | |
| 3 | Rejected-Technical AT SINGH SAHI PO TALCHER TOWN DIST ANGUL ODISHA PIN 759107 | TALCHER TOWN | ANGUL | ODISHA | 759107 | - | Rejected-Technical REJECTED FOR NOT BEING L1 | |
| 4 | Rejected-Technical AT KUMUNDA PLOT NO 6233 8830 PRAGATI NAGAR ANGUL ODISHA | ANGUL | ANGUL | ODISHA | 759143 | - | Rejected-Technical REJECTED FOR NOT BEING L1 |
Tender Value
₹43.3 L
EMD Value
₹54,200
Closing Date
15 Mar 2024, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Staff Officer(EnM), Jagannath Area, MCL
Jay Prakash, Staff Officer(EnM), Jagannath Area, MCL PH 06760-269717, 06670-269751(Extn)2023 Fax 06760-269527 E-mail so-enm-jaga.mcl(at)coalindia.in
Day to day work for 11 kV. 3.3 kV and LT over head line erection/maintenance work of with erection / dismantle of light fitting as required mounted on poles / structures etc. at Surface area of Ananta OCP Jagannath Area for a period of Two years
2024_MCL_303299_1
GM(JA)/EnM/e-Tender/ 23-24/E-628/54 DTD. 01/03/24
Open Tender
Electrical and Maintenance Works
Item Rate
730 days
ANANTA OCP, JAGANNATH AREA
AS PER NIT
4 documents required · 4 mandatory
₹54,200
11 May 2024
1 Mar 2024
18 Mar 2024
2 Mar 2024
15 Mar 2024
2 Mar 2024
2 Mar 2024 - 7 Mar 2024
Amount
Engagement of manpower to perform the following Surface area works: 1. Erection/Dismantling of ACSR/aluminum OH conductor, Cradle guard, G.I wire, angle iron/ channel iron cross arms, LV/MV shackle/pin insulators, weather proof Al. wire, AB cable etc. 2. Installation/Dismantling of ICTPN/ICTP/ICDP of different rating. 3. Installation/Dismantling of Light fittings on pole/ structure / Tower safely as required. 4. Collection of light fittings from store (materials to be supplied departmentally). 5. Dismantling/Installation and connection of PVC/ XLPE cable from Over Head lines to transformer. 6. Fault finding and alignment of lights on tower/pole. 7. Tree trimming as required. 8. Any other works as required for surface lighting work as per instruction of EIC or his representative. Deployement of manpower is as follows:
02 nos skilled electricians per day having suitable Electrical Workman’s permit issued by ELBO and ability to perform aforesaid works having proper tools and tackles.Manpower deployed = 1 in 1st shift and 2 is in 2nd shift.
2 no Semi-skilled Electrical Helper per day.
Dismantling of pole/street light standard/strut embedded in cement concrete foundation etc. as required.
Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required.
Supplying and erection of stay set complete (galvanized) with 19/20mm dia X 1.8 metres long stay rod, anchor plate of size 45cm X 45cm X 7.5mm thick, thimble, stay clamps, bow tightener, 7/3.15mm dia G.I stay wire and strain insulator etc. in cement concrete 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc as required.
Supplying and erection of 11 KV pin insulator 5 KN polymer type complete with large steel head G.I. pin, nuts, washers etc. as required.
Supplying and erection of 11 KV disc insulator 90 KN polymer type for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 2 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required .
Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required .
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required .
Supplying of 50 mm X 8 mm M.S. flat iron pole top bracket/ cross arm for single 11/22/33 KV over head line conductor complete with fixing clamps, bolts, nuts and washers drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required
Supplying and erection of a set of cross bracing frame work for 11 KV over head line double pole structure having four members fabricated out of 50 mm X 50 mm X 6 mm angle iron to form a rectangle of minimum size 1400 mm width X 2500 mm height , complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required .
Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
Supply of 400 Amp horizontal type GOAB male & female contact 3 nos for 1 GOAB.
Supply of Mechanism ball bearing for GOAB operating rotor
Supply of GOAB operating long pipe with necessary arrangement as required.
Supply of G.I wire 6 /8 SWG
Supplying of Shackle insulator (100 mm X 110 mm) with G.I. bolts and nuts.
Supplying of G.I. strap for shackle insulator
Supplying of Pin insulator (100 mm X 80 mm) with G.I. spindle and nuts
Supply of 1.1 kv 25 Sqmm 4 core pvc sheathed armoured aluminium cable.
Laying and fixing of one number pvc insulated and pvc sheathed /XLPE power cable of 1.1 kv grade of following size on wall surface as required. Up to 35 Sqmm
Total impact of GST for the purpose of CTC
M/S. JAY MAA HINGULA
J.N. RAY
Sachin Kumar Pradhan
techsummary_314189.pdf
PDF • 0.30 MB
finsummary_314189.pdf
PDF • 0.30 MB
LOAE628.pdf
PDF • 2.00 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .