| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹5.8 LAdmitted-Finance | Admitted-Finance | |
| 2 | ₹5.9 LAdmitted-Finance | Admitted-Finance | |
| 3 | ₹5.9 LAdmitted-Finance | Admitted-Finance | |
| 4 | ₹5.9 LAdmitted-Finance | Admitted-Finance | |
| 5 | ₹5.9 LAdmitted-Finance | Admitted-Finance |
| Sl No | Description | Qty | Unit | Patiaya Enterprises | M/S PIONEER ENGINEERS | M/S SHANTI ELECTRICALS | M/S NEW TRIKUTA TECHNOCRATES | M/S DAYAL BUILD TECH | M/S KUNDAL ELECTRICAL WORKS AND SUPPLIERS | Noor Hussain and Sons | M/s Wazir Agencies | KULDEEP KUMAR SUDAN | M/S RAJ ELECTRICAL CONTRACTOR | JASMEET SINGH | M/s GCS Associates | M/S A A ENTERPRISES | M/S SWASTIC ELECTRICAL CONTRACTOR AND SUPPLIERS |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Auto-Transformers/Power Transformers :- A) Checking of Auto starting of fans, External cleaning of radiators,oil pumps, ONAF/OFAF cooling,Cleaning and checking of marshalling boxes of transformer and OLTC, (ii) Tightening of terminations, Checking of OLTC driving mechanism, Electrical checking/ testing of pressure relief device, Buchholz relay, OLTC surge relay/ checking of alarm/ trip and checking/ replacement of the gaskets of the terminal box, Checking / Tightning of earthing connections, Checking of earth resistance of Neutral, Replacement of Silca Gel of breathers and oil toping of transformers and tightning of bushing clamps on HV/IV/LV sides of Auto transformers and 50MVA Power transformers.Checking of space heater and illumination,etc.Required as per schedule of maintenance. | |||||||||||||||||
| 1.02 | 160 MVA , 220/132 KV | 1 | No. | 32,400 ₹32,400 | 29,700 ₹29,700 | 27,000 ₹27,000 Lowest | 55,000 ₹55,000 | 50,000 ₹50,000 | 28,000 ₹28,000 | 27,005 ₹27,005 | 27,000 ₹27,000 Lowest | 50,000 ₹50,000 | 29,000 ₹29,000 | 27,000 ₹27,000 Lowest | 29,900 ₹29,900 | 30,000 ₹30,000 | 27,000 ₹27,000 Lowest |
| 1.03 | 50 MVA , 132/33 KV | 1 | No. | 16,000 ₹16,000 | 13,970 ₹13,970 | 12,700 ₹12,700 Lowest | 55,000 ₹55,000 | 50,000 ₹50,000 | 13,000 ₹13,000 | 12,710 ₹12,710 | 12,700 ₹12,700 Lowest | 60,000 ₹60,000 | 15,000 ₹15,000 | 12,700 ₹12,700 Lowest | 14,000 ₹14,000 | 15,000 ₹15,000 | 12,700 ₹12,700 Lowest |
| 1.04 | 20 MVA , 132/33 KV | 1 | No. | 14,000 ₹14,000 | 4,400 ₹4,400 | 4,000 ₹4,000 Lowest | 45,000 ₹45,000 | 40,000 ₹40,000 | 4,000 ₹4,000 Lowest | 4,010 ₹4,010 | 4,000 ₹4,000 Lowest | 50,000 ₹50,000 | 4,200 ₹4,200 | 4,000 ₹4,000 Lowest | 11,100 ₹11,100 | 5,000 ₹5,000 | 4,000 ₹4,000 Lowest |
| 2.00Routine Maintenance of Auxilliary Transformers including checking of gaskets,checking and tightening of earthing connections,tightening of bushing clamps,replacement of Silica Gel,etc | |||||||||||||||||
| 2.02 | 250KVA, 33/0.440 KV Auxilliary Transformer | 1 | No. | 5,500 ₹5,500 | 3,025 ₹3,025 | 2,750 ₹2,750 Lowest | 40,000 ₹40,000 | 40,000 ₹40,000 | 2,800 ₹2,800 | 2,755 ₹2,755 | 2,750 ₹2,750 Lowest | 10,000 ₹10,000 | 2,750 ₹2,750 Lowest | 2,750 ₹2,750 Lowest | 3,350 ₹3,350 | 2,750 ₹2,750 Lowest | 2,750 ₹2,750 Lowest |
| 2.04 | Draning/ De-sludging of oil of transformers | 1 | per Kilo Ltr | 1,600 ₹1,600 | 935 ₹935 | 850 ₹850 Lowest | 10,000 ₹10,000 | 10,000 ₹10,000 | 900 ₹900 | 850 ₹850 Lowest | 850 ₹850 Lowest | 10,000 ₹10,000 | 850 ₹850 Lowest | 850 ₹850 Lowest | 1,150 ₹1,150 | 1,000 ₹1,000 | 850 ₹850 Lowest |
| 2.05 | Filling of oil, filtration and dehydration of transformer including carriage of filteration plant to be provided by the Department. | 1 | per Kilo Ltr | 1,600 ₹1,600 | 1,100 ₹1,100 | 1,000 ₹1,000 | 10,000 ₹10,000 | 10,000 ₹10,000 | 1,100 ₹1,100 | 995 ₹995 Lowest | 1,000 ₹1,000 | 20,000 ₹20,000 | 1,000 ₹1,000 | 1,000 ₹1,000 | 2,500 ₹2,500 | 1,100 ₹1,100 | 1,000 ₹1,000 |
| 2.06 | Reparing of cooling fans of transformers including replacement of damaged winding, bearing etc. | 1 | No. | 6,000 ₹6,000 | 2,613.6 ₹2,613.6 | 2,376 ₹2,376 Lowest | 20,000 ₹20,000 | 20,000 ₹20,000 | 2,376 ₹2,376 Lowest | 2,376 ₹2,376 Lowest | 2,376 ₹2,376 Lowest | 20,000 ₹20,000 | 2,376 ₹2,376 Lowest | 2,376 ₹2,376 Lowest | 3,700 ₹3,700 | 2,500 ₹2,500 | 2,376 ₹2,376 Lowest |
| 2.07 | Lifting of top lid of power transformer for complete physical inspection & replacement of gaskets. | 1 | No. | 8,000 ₹8,000 | 3,850 ₹3,850 | 3,500 ₹3,500 Lowest | 20,000 ₹20,000 | 20,000 ₹20,000 | 3,600 ₹3,600 | 3,505 ₹3,505 | 3,500 ₹3,500 Lowest | 20,000 ₹20,000 | 3,500 ₹3,500 Lowest | 3,500 ₹3,500 Lowest | 4,100 ₹4,100 | 3,500 ₹3,500 Lowest | 3,500 ₹3,500 Lowest |
Tender Value
Refer Docs
EMD Value
₹25,000
Closing Date
30 Apr 2025, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer, TLMD-VIII, JKPTCL, Jammu
Office of the Executive Engineer, TLMD-VIII, JKPTCL, Ambedkar chowk, Jammu.
Rate Contract for Preventive/ Routine / Breakdown maintenance for various 220/132/33 KV Grid stations falling under the jurisdiction of TLMD-VIII
2025_PDD_275180_1
e nit no TLMD-VIII/J/T/01 of 2025-26 dated- 03/04/2025
Open Tender
Electrical and Maintenance Works
Item Rate
7 days
poonch, rajouri, kalakote
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,000
Executive Engineer, TLMD-VIII, JKPTCL, Jammu
₹25,000
Office of the Executive Engineer,TLMD-VIII,JAMMU
19 Sept 2025
9 Apr 2025
2 May 2025
9 Apr 2025
30 Apr 2025
9 Apr 2025
16 Apr 2025
Auto-Transformers/Power Transformers :- A) Checking of Auto starting of fans, External cleaning of radiators,oil pumps, ONAF/OFAF cooling,Cleaning and checking of marshalling boxes of transformer and OLTC, (ii) Tightening of terminations, Checking of OLTC driving mechanism, Electrical checking/ testing of pressure relief device, Buchholz relay, OLTC surge relay/ checking of alarm/ trip and checking/ replacement of the gaskets of the terminal box, Checking / Tightning of earthing connections, Checking of earth resistance of Neutral, Replacement of Silca Gel of breathers and oil toping of transformers and tightning of bushing clamps on HV/IV/LV sides of Auto transformers and 50MVA Power transformers.Checking of space heater and illumination,etc.Required as per schedule of maintenance.
160 MVA , 220/132 KV
50 MVA , 132/33 KV
20 MVA , 132/33 KV
Routine Maintenance of Auxilliary Transformers including checking of gaskets,checking and tightening of earthing connections,tightening of bushing clamps,replacement of Silica Gel,etc
250KVA, 33/0.440 KV Auxilliary Transformer
Draning/ De-sludging of oil of transformers
Filling of oil, filtration and dehydration of transformer including carriage of filteration plant to be provided by the Department.
Reparing of cooling fans of transformers including replacement of damaged winding, bearing etc.
Lifting of top lid of power transformer for complete physical inspection & replacement of gaskets.
Replacement of damaged core bolts/Earthing strip etc.
Testing of Transformer:-
Tandelta testing of bushing/ winding and winding resistance of Transformer.
SFRA testing including arrangement of KIT by successful bidder.
Turn Ratio testing of Transformer.
IR Testing
BDV testing of transformer oil
Low voltage testing:
Magnetic balance test
short circuit test
DGA and PPM of Transformer from accredited laboratories (it include cost of collection of sample from site, its delivery to the testing labortary and depositing back the sampling bottle)
Replacement of damaged/outlived bushing having high tan delta including crane/ mechanical equipment if required.
220 KV Bushing
132 KV Bushing
33 KV Bushing
Overhauling of Circuit Breaker :- VCB/MOCB/SF6 Checking of oil/gas pressure drop during duty cycle operation check, Checking of auto-starting / stopping of oil pump,pressure switch setting,etc, Checking of healthiness of accumulator by checking the pre-charging pressure when building up pressure from zero, Checking of operation of safety valve, Cleaning of breaker units, checking of protection equipments and replacement of defective ones, i.e., complete inspection and testing of SF6/VCB/MOCB type circuit breakers inclusive of operating mechanism.Checking of driving mechanism, trip/closing circuits/ checking of spring charge motor and checking of tripping and closing coils.checking of equipment earthing and strucure earthing. Maintaning gas levels, venting of circuit breakers, replacement of o-rings , gas kets including circuit breaker analysis by Circuit breaker analyser.Checking of space heater and illumination.Required as per schedule of maintenance
220KV SF6 Breaker
132KV SF6 Breaker
33 KV VCB
Testing: VCB/MOCB/SF6 Testing of SF6/VCB/MOCB type circuit breakers by Circuit breaker analyser Test kit.
220KV SF6 Breaker
132KV SF6 Breaker
33 KV VCB
Replacement of damaged/defective pole of the circuit Breaker after thorough inspection, including its carriage from divisional store to the site of work and back carriage of the damaged/defective equiupment to the divisional store.
220KV SF6 Breaker
132KV SF6 Breaker
33 KV VCB
Replacement of damaged/defective operating mechanism box of the circuit Breaker after thorough inspection, including its carriage from divisional store to the site of work and back carriage of the damaged/defective equiupment to the divisional store.
220KV SF6 Breaker
132KV SF6 Breaker
CVT's /CT's /PT's :- Visual checking of earthing HF point (in case it is not being used for PLCC,Checking of any breakage or cracks in porclean insulator, Cleaning of CVT capacitor stacks and tightness of terminal connections,Checking and tightness of all connections including earth connections.Checking of healthiness of gaskets, Checking of neutral earthing in CVT, healthiness of all gaskets and oil level and its topping. Releasing of gas pressure if any.
CVT's /CT's /PT's :- Measurement of IR value, Tan delta, knee point value, burden etc. and tightening of all connections and droppers.
CVT's /CT's /PT's :- Primary injection test of CT/PT and tightening of all connections and droppers.
Replacement of damaged CT/PT including carriage of the Equipment from divisional store to the site of work and back carriage of the damaged equiupment to the divisional store. It also includes the replacement of damged cntrol cable if any and making connection at secondary winding and in M.K box.
Surge Arrestors :- Testing of counters and leakage current meters, Cleaning of insulators, Checking of earth connections between surge arrester,surge monitor and earth, Checking of leakage current after cleaning of porcelain surface, cleaning of LA insulators. Measurement of IR value and tightening of droppers.
Surge Arrestors :- Checking of leakage current(third harmonic resistive current)
Replacement of damaged Surge Arrestor including carriage of the Equipment from divisional store to the site of work and back carriage of the damaged equiupment to the divisional store.
Isolators :- Maintenance of linkages including transmission gears, stopper bolts. Cleaning of auxiliary switch contacts and greasing with silca grease, cleaning of support insulators, termination contacts, checking of electrical / mechanical interlocks with E/S and CB, mounting bolts, alignment, nuts, pins, space heater, illumination, healthiness of gaskets, auxiliary contacts, alignment of earthing blades, operation of earth switch, almunium / copper flexible conductor, earth connections of structures and MB. lubrication of operating mechanism, hinges lock joints, levers, bearings, main contacts, cleaning of post insulators, tightening of clamps.
Replacement of damaged Isolators including carriage of the Equipment from divisional store to the site of work and back carriage of the damaged equipment to the divisional store.
Reparing of Three phase motors of isolators including replacement of damaged winding and bearing.
Droppers/Jumpers Replacement of damaged / burnt droppers or jumpers of isolators/ breakers/transformers /CT/PT etc. 220/132/33 KV Yard.
Clamps: Replacement of damaged/burnt PG/ PAD/T/CT/Bushing clamp etc
Post Insulators :- Checking of insulators for cracks and cleaning of insulators.
Post Insulators :- Replacement of damaged/cracked Post Insulators.
Replacement of damaged Disc Insulators when lowering of conductor is necessary.
Illumination System :- Checking of healthiness of fittings in station buildings, outdoor switch yard, Tightening of terminals, etc.
Replacement of 90/200 watt LED in the outdoor switch yard
Replacement of LED/CFL along with fitting in the control room/ division building/office complex
Battery Bank: Checking and cleaning of battery cell terminals, application of petroleum gelly/anti rust spray if required and Checking of positive/Negative earth fault of dc.Terminal tightening.
Battery Bank: conduction of battery impendence test and discharge test checking voltage temperature, current, terminals voltage of individual cells, battery discharge testing etc.
Battery Charger :- Checking of control cards, measurement of test point voltage values, testing of DC earthfault and U/V relays, IR measurement of charger transformer, checking of earthing etc. Checking of charger panel / DCDB for electrical connections, cleanliness etc.
Protection System :- Checking of relays and application of CCl4 for cleaning, replacement of worn out / defunct relays, checking and replacement of control wiring, if required, primary & secondery injection testing,software settings etc.
Cleaning of cable trenches/ ducts including disposal of malba outside the premises of Grid Station.
sub main
Dressing of cables on trays/racks including repairing of trays/racks if required.
sub main
Repairing of damaged cable duct covers.
sub main
Gantry Columns and Beams :- Tightening of all nuts / bolts and providing of missing nuts / bolts and replacement of damaged members if required.
L.T. Transformer :- Testing of oil BDV, IR measurement, Testing /checking of OTI,WTI and Buchholz (if provided, Checking of healthiness of Pressure relief diaphragm, Checking healthiness of Buchholz relay.
L.T. Panel: Cleaning of panels,bus bar insulators etc. Relays Testing, Tightning of all electrical connections,Checking of indicating meters ,Check for change-over facility, if provided,Check operation /indications in OFF Load condition of MCCB,
Earthing Mat :- Measurment of earth resistivity, checking of electrical continuity of equipment earthings, tightening of earthing connectors, removal of rust from bolted earth connectors and tightening and additional earthing wherever required.
220/132 kV Transformer including allied equipment
132/33 KV Transformer including allied equipment
Replacement/repairing of Earthing of various Equipments.
DC Distribution Board :- Checking of connections, wiring, replacement of wiring if needed and checking of healthiness of all D/C and dc circuits of 220/132/33 KV yards
AC Distribution Board :- Checking of connections, wiring, replacement of wiring if needed, fuses, MCB, bus bar CT, relays, MFM, LT switchs etc and checking of healthiness of all connections and AC circuits of 220/132/33 KV yards
Control cables:- Replacement of damaged/outlived/burnt control cables of different cores icluding proper ferruling, thimbling and tagging and finally with all appropriate connections including lifting of duct covers
below 10 core
above 10 core
Marshelling kiosk:- checking and replacing if required of all Terminal blocks, space heaters, light illumination, checking of all connnections and its cleaning. Fixing of cable glands earthing and checking of all other electrical accessories. Fixing of damaged hinges/locks(including their cost if any) if required and plugging of holes if any.
BUS BAR :- Replacement of damaged ACSR Conductor along with its fittings.
220 KV yard
132 KV yard
33 KV yard
Automatic voltage regulator:- checking and tightening of connections, auto control unit, oil and its overhaulling
Diesel Generator set: Maintenance and checking of its operation.
Diesel Generator set: overhauling of DG set including all material required for it.
Deweeding of switch yard
Painting of outdoor equipments (Transformers, MK's, CT/PT/CVT, Protection wall, Circuit breaker, isolators, poles etc.
AC Units: Checking and Servicing of Installed AC unit inside control room (1- 3 Ton)
White-Washing of Control Room/Residencial Quarters/Office building at Grid Station.
Upkeep of Sanitary installed in the control room/ office building/division building/residential quarters/Toilets and replacement of any damaged item if required.
Upkeep of electrical accessories installed in the control room/ office building/division building/residential quaters/Toilets and replacement of any damaged item if required.
Providing of skilled/ semi skilled/ un skilled labour for the works which are not covered from s.no. 1 to 38
Skilled labour(Electrician/Fitter)
Semi- skilled labour(Asstt. Electrician/Asstt. Fitter)
Un skilled labour
Store handling:
Unloading of Material in the Divisional store
220/132/33 KV Breaker
220/132/33 KV CT's
220/132/33 KV PT's/CVT's
220/132/33 KV LA's
220/132/33 KV Isolator
220/132/33 KV Pannels
Angle Iron, MS Flat,Tar Steel, Tower Material
ACSR Conductor/Earth Wire/Control cables
Disc Insulator/Fiitings/Clamps/CGI Sheet T&P Items etc and Other Allied Materials
Cement/Crates
33KV/440 V Aux Transformer
Transformer Oil
Carriage of Material from Unloading site to stacking site and stacking the material properly
220/132/33 KV Breaker
220/132/33 KV CT's
220/132/33 KV PT's/CVT's
220/132/33 KV LA's
220/132/33 KV Isolator
220/132/33 KV Pannels
Angle Iron, MS Flat,Tar Steel, Tower Material
ACSR Conductor/Earth Wire/Control cables
Disc Insulator/Fiitings/Clamps/CGI Sheet T&P Items etc and Other Allied Materials
Cement/Crates
33KV/440 V Aux Transformer
Transformer Oil
Shifting of material to make the space for adjustment of material
220/132/33 KV Breaker
220/132/33 KV CT's
220/132/33 KV PT's/CVT's
220/132/33 KV LA's
220/132/33 KV Isolator
220/132/33 KV Pannels
Angle Iron, MS Flat,Tar Steel, Tower Material
ACSR Conductor/Earth Wire/Control cables
Disc Insulator/Fiitings/Clamps/CGI Sheet T&P Items etc and Other Allied Materials
Cement/Crates
33KV/440 V Aux Transformer
Transformer Oil
Carriage of material from divisional store to loading site
220/132/33 KV Breaker
220/132/33 KV CT's
220/132/33 KV PT's/CVT's
220/132/33 KV LA's
220/132/33 KV Isolator
220/132/33 KV Pannels
Angle Iron, MS Flat,Tar Steel, Tower Material
ACSR Conductor/Earth Wire/Control cables
Disc Insulator/Fiitings/Clamps/CGI Sheet T&P Items etc and Other Allied Materials
Cement/Crates
33KV/440 V Aux Transformer
Transformer Oil
Loading of material in the vechile.
220/132/33 KV Breaker
220/132/33 KV CT's
220/132/33 KV PT's/CVT's
220/132/33 KV LA's
220/132/33 KV Isolator
220/132/33 KV Pannels
Angle Iron, MS Flat,Tar Steel, Tower Material
ACSR Conductor/Earth Wire/Control cables
Disc Insulator/Fiitings/Clamps/CGI Sheet T&P Items etc and Other Allied Materials
Cement/Crates
33KV/440 V Aux Transformer
Transformer Oil
Sorting of Tower Material in the Divisional Store and Its Stacking at Proper Place including its Mannual Carriage within Store yard
Deweeding of store premises
Disposal of material/Mulba from the store to outside the store premises
Cleaning of Drainage/front area of store during Monsoon/Rainy season
Dismentaling of Old and Damged CGI Sheets
Fixing of New GI Sheets
Mechanical Carriage of T&P and Other Allied Material From Divisional Store to Site of Work and Back Carriage of T&P
Average Distance upto 40KM
Average Distance upto 60KM
Average Distance upto 80KM
Average Distance upto 200KM
Average Distance upto 300KM
Average Distance upto 400KM
Earth work
Excavtion of Earth
Disposal of excavated earth By manual uptp 500mtr
Disposal of excavated earth By MT upto 2 KM
M/S RAJ ELECTRICAL CONTRACTOR
Patiaya Enterprises
M/S A A ENTERPRISES
M/S SWASTIC ELECTRICAL CONTRACTOR AND SUPPLIERS
JASMEET SINGH
Noor Hussain and Sons
M/S KUNDAL ELECTRICAL WORKS AND SUPPLIERS
M/s Wazir Agencies
M/S SHANTI ELECTRICALS
KULDEEP KUMAR SUDAN
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .