| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.4 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹25.8 L+₹1.3 L (5.21%)Rejected-Finance 229 CHANDEL MARKET HARJINDER NAGAR KANPUR 208007 | KANPUR | KANPUR | UTTAR PRADESH | 208007 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹29.0 L+₹4.5 L (18.2%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹29.8 L+₹5.3 L (21.5%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹34.1 L+₹9.6 L (39.1%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹96,000
Closing Date
26 Oct 2020, 6:00 pmClosed
GE (AF) E/M CHAKERI KANPUR
GE (AF) E/M CHAKERI KANPUR 208008
COMPREHENSIVE MAINT OF INTERNAL ELECTRIFICATION OF TECHNICAL AREA AT AFS CHAKERI KANPUR
2020_MES_381485_1
8421/E8
Open Tender
Civil Works
Item Rate
274 days
GE (AF) E/M CHAKERI KANPUR
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) E/M CHAKERI
₹96,000
26 Nov 2020
28 Sept 2020
31 Oct 2020
28 Sept 2020
26 Oct 2020
12 Oct 2020
Amount
Receiving complaints from concern Incharge of Internal section (Power House) lodged by the occupants of Internal electrification nature, taking down tube light / CFL fitting/Bracket fittings/Flameproof tube light fittings/ bulkhead flameprrof fittings any wattage from roof /wall and PVC Cables for light/fan/bell/light or power socket complete repairs to the extent by removing connections from the system removing faults in wires, battens, conduit, suck boxes, juction boxes, main switches, MCBs/DBs utility light fitting, lamp holders AC ceiling/exhaust fans and other connected fixtures of the internal electrification including providing of petty stores such as wires of appropriate size and conductor matching to existing one upto the length of 1 mtr including insulation tap, screws, nuts as required to rectifing the fault with record to the complaint lodged and refixing of fittings, fixture to their position as dismantled complete all as directed at site to the entire satisfaction of Engr-in-charge/users. dismantling at site testing of unserviceable item and serviceable and replacement the same and tightening the connections,replacement of unserviceable connecting wire and ensuring the the earth wire is properly connected to earth wire and metallic part of fitting, cleaning of fittings externally and internally after ensuring the serviceablity of fittings & refixing the same at same place or as directed place testing complete all as specified and directed. Note - (i) Any spares required to be replaced to make light fittings serviceable shall be measured and aid for separately as consider under respective itmes. (ii) Attennding compliant including taking down/ refixing of flourescent tube light fitting and repair shall be measured under this items.
Supply and fix in repair Compact flourescent lamp (CFL ) 4 Pin type 1 x 36W , 230V complete all as specified and directed. Make :Philips/Wipro/CG
Supply and fix in repair ballast 1 x 28W , 230V complete all as specified and directed. Make :Philips/Wipro/Havells
Supply and fix in repair ectronic ballast 1 x 36W, 230V complete all as specified and directed. Make :Philips/Wipro/Havells
Supply and fix in repair Electronic ballast 1 x 18/20W 230V complete all as specified and directed. Make :Philips/Wipro/Havells
Supply and fix in repair Electronic ballast but 2x28W, 230V complete all as specified and directed.
Supply and fix in repair Electronic ballast but 2x 36W, 230V complete all as specified and directed. Make :Philips/Wipro/Havells
Supply and fix in repair Heavy duty VPIT copper ballast for FTL 40 Watt complete all as specified and directed. Make : Philips/Wipro/Havells
Supply and fix in repair Heavy duty VPIT copper ballast for FTL 18/20 Watt complete all as specified and directed. Make : Philips/Wipro/Havells
Supply and fix in repair Master LED Tube 1200mm 30 Watt complete all as specified and directed Make - Philips/wipro/Havells
Supply and fix in repair Master LED tube 1200 mm 18 Watt complete all as specified and directed. Make - Philips/wipro/Havells
Supply and fix in repair Metal Clad socket industrial 2 pin & earth plug top 20 A230 V suitable for AC box complete all as specified and directed.
Supply and fix in repair Metal Clad socket industrial 2 pin & earth plug socket 20 A230 V suitable for AC box complete all as specified and directed.
Taking down old unserviceable/deteriorated batten/MS conduit point wiring from existing place i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets, ceiling rose, pendants, Holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar (1 : 3) or plaster of Peris and to match / finish new surface as the existing surface either by using same colour distemper, Putti or white / colour wash complete all as specified and directed.
Taking down main switch/DB/ changeover/AC box of any capacity including fixing accessories complete all as specified and directed.
M & L for concealed point wiring on wall and surface wiring on ceiling/roof/trusses with necessary fixing arrangements with stranded PVC-FRLS insulated and unsheathed copper stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including 16 gauge stove enameled rigid steel conduit (metallic) not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.0 mm with earth dolly and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators with brass screw and cup washers including PVC-FRLS insulated and unsheathed copper stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces complete all as specified and directed. For one light, fan, call bell point controlled by one switch. Make of wire : Polycab/Havells/Plaza Make of conduit: - Kalinga/AKG/plaza
All as per item No. 16 but 5Amp independent socket point controlled by one switch.
all as per iten No 16 for one socket point controlled by one switch on same board
all as per iten No 16 for One light point controlled by two, two way switch.
All as per item No 16 here-in-before but for power point wiring with 2.5 Sqmm PVC-FR insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 2.5 Sqmm PVC-FR insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
M & L for concealed point wiring on wall and surface wiring on ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and Bakelite laminated sheet 3mm thick ISI marked for fixing of switches / sockets, fan regulators with brass screw and cup washers including PVC-FRLS insulated and unsheathed copper stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces complete all as specified and directed. For one light, fan, call bell controlled by one switch. Make of wire :- polycab/plaza/Havells Make of conduit: Plaza/AKG/Kalinga
All as per item No. 21 but 5Amp independent socket point controlled by one switch.
All as per item No. 21 but For one socket point controlled by one switch on same board
All as per item No 21 here-in-before but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
All as per item No 21 here-in-before but in existing concealed/surface conduit(Steel/PVC) for one light, fan, call bell point controlled by one switch.
All as per item No.21 but 5Amp independent socket point controlled by one switch.
All as per item No.21but For one socket point controlled by one switch on same board
All as per item No 21 here-in-before but for power point wiring in existing concealed/surface conduit with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
M & L for surface point wiring on wall and surface on ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including casing caping 20 / 25 mm white / ivory with all accessories/ fittings such as junction boxes, bends, tee, elbow etc including PVC / Polycarbonate gang box of appropriate size for fixing of switches / sockets, fan regulators, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing complete all as specified and directed for the following :- For one light, fan, call bell. Make of Wire : Polycab/Havells/Finolex. Make of Casing Caping : Plaza/Kalinga/AKG
All as per item No.29 but 5Amp independent socket point controlled by one switch.
Ditto -all as per item No 29 here-in-beforebut for one socket point controoled by one switch on same board
M&L , in replacement for Modular switch 1 Way 6 Amps, 240 Volt all as specified and directed.
M&L , in replacement for Modular switch 1 Way 16 Amps, 240 Volt all as specified and directed.
M & L Modular Socket 6/2 pin Combined 2 module complete all as specified and directed.
M&L Modular socket 6A/16Amp -2/3 pin Combined 2 module complete all as specified and directed.
M & L, in repair, for switch flush type single pole one way 5 Amps, 240 volts, white finish ISI Marked complete all as specified and directed. Make : Leader /Anchor/Havells
M & L, in repair for switch flush type single pole two way 5 Amps, 240 volts, white finish ISI Marked complete all as specified and directed. Make : Leader /Anchor/Havells
M & L, in repair , for switch flush type 15 Amps, 240 Volts single pole white finish complete ISI Marked complete all as specified and directed. Make : Leader /Anchor/Havells
M&L, in repair , for socket outlet 5 pin, 5 Amps flush type white finish complete conforming/ ISI Marked complete all as specified and directed. Make : Leader /Anchor/Havells
S&F, in repair , socket outlet 2 in 1, 3 pin, 5/15 A, flush type universal, 240 V white finish complete conforming/ ISI Marked complete all as specified and directed. Make : Leader /Anchor/Havells
M&L, in repair , for bell push, flush type 5 Amps white finish completeconforming/ ISI Marked complete all as specified and directed. Make : Leader /Anchor/Havells
S&F, in repair for electronic socket size, rotary, 5 speed step type regulator, 120-230 V white finish complete conforming/ ISI Marked complete all as specified and directed. Make : Leader /Anchor/Havells
S& F, in repair for Call bell multi music type 230V, single pole conforming/ ISI Marked complete all as specified and directed. Make : Leader /Anchor/Havells
S&F, in repair , for ceiling rose, surface backlite, 65 x 20 mm three terminalconforming/ ISI Marked complete all as specified and directed. Make : Leader /Anchor/Havells
S&F, in repair , for lamp holder insulated body with back plate suitable for angle / batten fitting conforming/ ISI Marked complete all as specified and directed. Make : Leader /Anchor/Havells
S&F in repair ,for sheet metal enclosure TPNL MCCB DB 4way, 415 V (vertical type) with bus bar double door type IP 43 - IK 09 for DB when MCBs & MCCB 125 Amps (as incomer) to be used, fixed properly on / in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs for cables/wires complete all as specified and directed. Make - Legrand/Scheinder/L&T
S&F for in repair double door metallic sheet metal enclosure for DB when MCBs to be used TPNL, 4 ways, 415Volts (horizontal type) with 200 Amps rated bus bar suitable for TPN MCB/ 4 pole Isolator fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs for cables/wires complete all as specified and directed. Make - Legrand/Scheinder/ABB
S&F, in repair for double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and directed. Make - Legrand/Scheinder/ABB
All as per item No 49 above but 4ways & - do -
All as per item No 49 above but 2ways without busbar & - do -
S&F in repair for testing and commissioning of MCB SP 240 volt 6 Amp to 32 amp 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed. Make - Legrand/Scheinder/ABB
All as per item No 52 above but SP 40-63 Amps -do-
All as per item No 52 above but SPN 16-32 Amps -do-
All as per item No 52 above but SPN 40-63 Amps -do-
All as per item No 52 above but TP 40-63 A 415V -do-
All as per item No 52 above but TPN 40-63 Amps, -do-
S&F in repar for MCCB 125 Amps, 4 Pole, 415V, 25KA
S&F in repair for sheet metal enclosure , 20A single pole and neutral with a two pin and earth plug and socket complete in metal clad board (Industrial type) with one single pole MCB 32 Amp fixed properly on in concealed position complete all as specified and directed. Make - Legrand/Scheinder/L&T
S&F in repair metal clad socket industrial 2pin & earth plug top 32A, 230V suitable for AC Box complete all as specified and directed. .
S&F in repair metal clad socket industrial 2pin & earth plug socket 32A, 230V suitable for AC Box complete all as specified and directed.
S&F in repair for sheet metal enclosure , 32A, 415 Volts triple pole neutral & earth with a three pin and earth plug and socket complete in metal clad board (Industrial type) with one TP MCB 32 Amp fixed properly on / in concealed position complete all as specified and directed. Make - Legrand/Scheinder/ABB
S&F in repair for sheet metal enclosure , 63A, 415 Volts triple pole neutral & earth with a three pin and earth plug and socket complete in metal clad board (Industrial type) with one TPN MCB 63 Amp fixed properly on / in concealed position complete all as specified and directed. Make - Legrand/Scheinder/ABB
M&L sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 2.5 sqmm drawn in PVC Conduit with 2.5 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete including taking down old unserviceable submain wiring complete all as specified and directed. Note - PVC Conduit pipe will be measured and paid separately Make of wire : Plaza/polycabe/Havells Make of conduit :- AKG/Kalinga/finolex
M&L sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 2.5 sqmm drawn in MS Conduit with 2.5 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete including taking down old unserviceable submain wiring complete all as specified and directed. Note - MS Conduit pipe will be measured and paid separately Make of wire : Plaza/polycabe/Havells Make of conduit :- AKG/Kalinga/finolex
M&L sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 4 sqmm drawn in MS conduit with 4.0 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete including taking down old unserviceable submain wiring complete all as specified and directed. Note - PVC Conduit will be measured and paid separately Makr wire : Plaza/polycabe/Havells Make of conduit :- AKG/Kalinga/finolex
M&L sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 4 sqmm drawn in MS conduit with 4.0 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete including taking down old unserviceable submain wiring complete all as specified and directed. Note - MS Conduit will be measured and paid separately Makr wire : Plaza/polycabe/Havells Make of conduit :- AKG/Kalinga/finolex
M&L sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 6 sqmm drawn in PVC conduit with 6 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete including taking down old unserviceable submain wiring complete all as specified and directed. Note : PVC conduit will be measured and paid separately Makr wire : Plaza/polycabe/Havells Make of conduit :- AKG/Kalinga/finolex
M&L sub main wiring with two single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 6 sqmm drawn in MS conduit with 6 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete including taking down old unserviceable submain wiring complete all as specified and directed. Note : M S Conduit will be measured and paid separately Makr wire : Plaza/polycabe/Havells Make of conduit :- AKG/Kalinga/finolex
M&L sub main wiring with four single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 6 sqmm drawn in MS conduit with 2 run of 6 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete including taking down old unserviceable submain wiring complete all as specified and directed. Note : M S Conduit will be measured and paid separately. Mak of wire : Plaza/polycabe/Havells Make of conduit :- AKG/Kalinga/finolex
M&L sub main wiring with four single core PVC-FRLS insulated unsheathed multi stranded copper conductor cable of size 10 sqmm drawn in MS with 2 run of 10 Sqmm PVC-FRLS insulated unsheathed multi stranded copper conductor as a continuous earth wire complete including taking down old unserviceable submain wiring, rigid stove enameled steel conduit complete all as specified and directed. . Note : M S Conduit will be measured and paid separately Make wire : Plaza/polycabe/Havells Make of conduit :- AKG/Kalinga/finolex
S&F rigid metallic medium 20mm dia stove enameled steel conduit ISI marked in concealed position inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, saddlers, pipe hooks etc fixed properly on as in concealed position complete all as specified and directed.
All as per item No. 72 above but metallic medium 25 mm dia stove enameled steel conduit ISI marked -do-
All as per item No. 72 above but metallic medium 32 mm dia stove enameled steel conduit ISI marked -do-
S&F rigid metallic medium 20mm dia PVC conduit ISI marked in concealed position inclusive all fitting such as tee, bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock, nuts, saddlers, pipe hooks etc fixed properly on as in concealed/Surface position complete all as specified and directed. Make wire : Plaza/polycabe/Havells Make of conduit :- AKG/Kalinga/finolex
All as per item No. 75 above but metallic medium 25 mm dia PVC conduit ISI marked -do-
All as per item No. 75 above but metallic medium 32 mm dia PVC conduit ISI marked -do-
Cutting chases in brick walls, pinning in at the depth of 30 mm, making good to facings where required and pointing in cement mortar 1:3 cutting chases for concealed conduit wiring,submain wiring etc and making good and palstering the surface with cement or plaster of peris and matching with same colour scheme, cutting exceeding 10cm but not exceeding 30cm girth complete all as specified and directed.
M&L for earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the earth plate not less than 1.5M below normal GL, connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 15 mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I, 2009 specification complete all as specified and directed.
Extension to earth connection with 4 mm dia GI wire fixed on surface in wall or in recess or drawn in conduit for loop earthing complete all as specified and directed.
M&L for cutting / boring of PCC/hard standing at a depth not more than 15 cm deep and 15 cm in breadth for passing earthing conductor and making good the disturbed surfaces with PCC (1:2:4) type B-0 or cement mortar (1:3) complete all as specified and directed.
Supply and fixing of GI pipe light grade of size 15 mm bore for laying in trenches/floors or walls including all fittings for fixing complete all as specified and directed.
M&L for testing of old earthing using calibrated earth tester & submitting result to engr -in -charge. Earthing which showing much more results as specified in IS rule and disconnetivity should be replaced with new earthing items are considered as below complete all as specified and directed. Note : (i) Watering of earthing with 2 Buckets (30Ltrs) water mixed with salt (total 5 Kg) shall be carried out one day before the testing & the cost of the same shall deemed included in unit rate quoted.
M&L for painting on wall with synthetic enameled paint of black colour of 200 x 150 mm size and writing work for earth test result with date & year complete all as specified and directed.
Material & Labour in repair for Recess LED 36 Watt 600x600mm fitting made of CRCA powder quoted finish with Fully Covered by PMMA Acrylic Lumio Diffuser, LED Used shall be SMD type and fixture should have minimum efficacy at System level (Not Chip Level) >=100lumens/watt, Life of fixture 50000hrs@L70% Lumen maintenance, CCT up to 6500, CRI >80, PF >0.95, an operating Voltage Range of 140 - 270 V.Minimum Internal Surge Protection 2.5KV The fixture should comply with the parameters as per IS10322 and IEC60598, EMC / EMI compliance, Maximum Wattages 37W, Minimum system Lumens 3400 complete all as specified and directed. Make: Philips Models RC380B LED36S 6500 G4L60W60PSUODWNOC or Equvilanet in WIPRO / Havells
Supply and Fix in repair for LED 4ft Batten 40 Watt with a nominal system lumen output of 2000 lumens and a minimum system efficacy of 105 lm/W. The luminaire shall have a rated system lifetime of 40,000 burning hours at L70. The luminaire should have a color temperature of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.95. The luminaire housing should made of CRCA with a PC glossy diffuser. The total power consumption should not exceed 19W (including driver) complete all as specified and directed. Make: Philips Make ENDURALED BATTEN "BN 100C LED 40S-6500 PSU L120 GR or Equvilanet in WIPRO/Havells
Supply and fix in repair LED Recessed 36 Watt Luminaire with a nominal system lumen output of 3250 lumens and a minimum system efficacy of 90 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70. The luminaire should have a color temperature of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD<10% and PF >0.9 and an operating Voltage Range of 140 - 270 V. The luminaire housing should made of powder coated metallic CRCA with high efficiency opal diffuser. The total power consumption should not exceed 36W (including driver) complete all as specified and directed. Make: Philips Make FULLGLOW 1x4 RC 380B LED 36S - 6500 G5 L3 W12 PSUOD equivlent in WIPRO/Havells
S & F in repair for energy saver LED light fitting 40 watt, 230 Volts, single tube mounting including LED Tube/ LED blocks 36 Watt ,Lumen OUTPUT NOT LESS THEN 115 lM /WATT with 50000 burning Hours, PF = 0.95 complete with electronic driver LED Printed board, end cover, connector box etc and accessories, prewired, LED including required fixing arrangements and electrical connection three core copper cable from ceiling rose to led light fitting complete all as specified and directed. Make PHILIPS BN 108C LED 40S PSU CDL WH OR EQUIVALENT IN WIPRO/HAVELLS
Supply and fix in reapir for High Pressure Die Cast Aluminium (LM6) Alloy hosuing SMD LED High Bay Luminaire of 120watt 14500 system lumen specially designed heat sinks dust free, product with Compnay LOGO Engraved.system wattage Max 120watt. narrow beam optics with 2*30 degree Rotational symmetry beam (for high ceiling heights) also Having beam Angle 110/120Degree,PMMA material Penuts Lenses for effective light distribution, Luminious flux (Lumen)14300.Corelated Color Temp 6500k,CRI>80,Maintenance of lumen L70 (Hrs) 50K@L70,Ambient temperature (Ta) 45Degree,optics widebeam optics,optical cover glass.Aluminium PDC Housing. Protection of Fixture:- IP65,IK08,Class I,Line Frequency 50/60 HZ,power factor >0.95,Deriver Efficiency >90%,Surge protection 2KV,Votage range 120-277V AC complete all as specified and directed. Make :Philips Models BY415P LED145S CW NB FG PSD GR SS or Equvilanet in WIPRO/Havells
Supply and fixing in repair for LED Post top made in die -cast aluminum with innovative glare free indirect lightining distribution and IP -65 protection prewired with all accessories comlete all as specified and directed. Make: Havells Endura Spring 6 PT 35 W LED 757PSYMTOTG or equivallent WIPRO/PHILIPS
M & L in repair of on load change over 4 pole ,415 volt 100 Amp including connecting material, nut bolts washer, lugs etc complete all as specified and directed. Make: L&T /Legrand/ABB
M & L in repair of on load change over 4 pole ,415 volt 250 Amp including connecting material, nut bolts washer, lugs etc complete all as specified and directed. Make: L&T /Legrand/ABB
Excavation in trenches in soft/loose soil not exceeding 1.5 m wide and n.exc 1.5 mtr in depth for laying of under ground electric cable and getting out complete all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in any type of soil complete all as specified and directed.
Removing excavated surplus materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Supply and spreading ganga sand dry, clean in trenches as cushioning to underground electric cable provided with a layer of 80mm deep before laying and 150mm over cable laid in trenches complete all as specified and directed.
Supply and laying dry bricks over cable laid in trenches as mechanical protection to cable with width equal to the length of bricks with well burnt sub class 'B' bricks complete all as specified and directed.
Supply and laying or fixing or passing through pipe, commissioning and testing 1100 volts grade XLPE insulated armoured heavy duty cable with aluminum conductor of cross sectional area 25 sqmm 3.5 core using stranded conductor complete all as specified and directed. Make - Havells/Polycab/Grandly
All as per item No. 98 but size 16 sqmm 4 core
All as per item No. 98 but size 10 sqmm 2 core
S & F in repair of LED building security light 110 watt of aluminium PDC housing glass cover with IP 66 protection complete all as specified and directed . Make: Cat Part No -410 LED 110CW HE MR FG S2PSUGR or equvalent Havells /wipro
M& L in repair for GI pipe light grade of size 40/50 mm bore,1.5 Mtr heavy grade base PCC work 1:2:4 of size300mmx300mm duly fixed with necessary nuts bolts and washers complete all as specified and directed .
S & F I n repair for 63A RCCB protection for double pole for 30 mA capacity and connected with suitable lugs in the e3lectric circuit complete all as specified and directed . Make: Legrand/ABB/Indoasia
S & F in repair for Highbay light fitting 150 watt with high pressure Die cast Alumenium (LM6) Alloy Housing smd led High Bay luminaries of 7o watt 7200 system lumen product with company logo enggrave system wattage 70 watt max symmetry beam ( For high ceilling heights) also having beam angle 110/120 degree, PMMA materials penutes lenses for effective light distribution, luminous flux (lumen L 70 (hours) ambient temp 45 degree optics wide beam optics optical glass cover glass alumenioum PDC housing IP 65IK-09 Class -1 Power factor .95, Driver efficiency 90% including fixing arrangment complete all as specified and directed. Make - Philips Cat Part No By 400 VLED 145S CW SKPSUS2FGWHor equivalent in wipro/C&S
M &L in repair for surface Mounted LED light having 20Watt out Put 1000 lumunes with burning temp 6500K with electric driver end cover connector box and all connected accessories all as directed at site complete all as specified and directed. Make: Philips - SM-251C LED 20S-6500 PSU WH or equvalent Havells/wipro
M & L in repair for LED spot light fitting,230 Volt with suitable mounting and accessories etc includingrequired fixing arrangments and electrcal connection including taking down existing light fitting complete all as specified and directed Make - Philips Cat Part no BGP310 3XLED -HP/WW 220-240 volt121 or equivalent in wipro/Havells
M & L in repair for SMD LED Flood light with minimum 21000 Lumens (at system level) with C clamp mounting and LM6 Pressure die cast housing with higher efficiency Glass cover Lens PMMA Impact resisitance IK 05,sysytem Power: 170 watt,Driver Efficacy >90% life L70 50K hrs, color temp cool white Luminaire efficacy >100 lumen /watt at system level LED Drive Current: Not more than 750mA and shopuld of single current rating (option of variation of drive current through hard ware/switches is not required) Junction temp:( at the soldring point should not exceed 55 degree C, Heat dissipation/heat sink : well designed thermal management system with PDC aluminium heat sink complete all as specified and directed. Make: Philips: BVP 192LED 110CWHONBFG GR PSU or equivalent or Havells/wipro
S&F in repair for LED 14watt spiral suitable for bulkhead type 230 volts complete all as specified and directed. Make - Havells/Philips/surya
A.B.Enterprises
S B ENTERPRISES
PAWAN COOL CORPORATION
kushwaha brothers
SRI SAI CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .