Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.0 LAccepted-AOC | ₹47.0 L | L1 | Accepted-AOC L1 offerer |
| 2 | L2₹47.0 L+₹177 (<0.01%)Rejected-Finance NO 25 9 DR NATESAN ROAD 1ST LANE TRIPLICANE CHENNAI 05 | CHENNAI | TAMIL NADU | 600005 | ₹47.0 L+₹177 (<0.01%) | L2 | Rejected-Finance L2 |
| 3 | L3₹47.9 L+₹87,503 (1.86%)Rejected-Finance NO 16 THIRUVALLUVAR SALAI CHINNATHIRUPATHI SALEM 638 008 | SALEM | SALEM | TAMIL NADU | 638008 | ₹47.9 L+₹87,503 (1.86%) | L3 | Rejected-Finance L3 |
| 4 | L4₹49.2 L+₹2.3 L (4.83%)Rejected-Finance NO 1 PPS COMPLEX METTUR MAIN ROAD OMALUR TALUK SALEM 636455 | SALEM | SALEM | TAMIL NADU | 636455 | ₹49.2 L+₹2.3 L (4.83%) | L4 | Rejected-Finance L4 |
| 5 | Rejected-Technical | - | - | Rejected-Technical They have not complied eligiblity criteria clause 1.2,1.6,1.7 |
Tender Value
Refer Docs
EMD Value
₹49,400
Closing Date
30 May 2023, 3:00 pmClosed
The DGM (CIVIL)
TCMPF Limited , ,Aavin illam,Nandanam-35
CONSTRUCTION OF COMPOUND WALL GAS STATION AND LAYING PAVER BLOCK IN STATE CENTRAL LAB MADAVARAM
2023_TCMPF_315935_1
4163/Engg.2/2023
Open Tender
Civil Works
Lump-sum
120 days
Madavaram
Refer tender document
7 documents required · 7 mandatory
₹0
₹49,400
Yes
TCMPF Limited ,Aavin illam,Nandanam-35
9 Aug 2023
16 May 2023
31 May 2023
16 May 2023
30 May 2023
23 May 2023
16 May 2023 - 30 May 2023
22 May 2023
Amount
Earth work narrow excavation for foundation in all soils and sub soils and to full depth as may be directed except hard rock requiring blasting inclusive of shoring, shuttering and baling out water where ever necessary, refilling the sides of foundations with excabvated earth in layers of not more than 15cm thk watered, well rammed , consolidated and depositing the surplus earth on bank with initial lead of 10m and initial lift of 2m, clearing and leveling the site etc., complete as directed by the federation officers and as per standard specifications.
Earth work open excavation for foundation in all soils and sub soils and to full depth as may be directed except hard rock requiring blasting inclusive of shoring, shuttering and baling out water where ever necessary , refilling the sides of foundations with excabvated earth in layers of not more than 15cm thk watered, well rammed , consolidated and depositing the surplus earth on bank with initial lead of 10m and initial lift of 2m, clearing and leveling the site etc., complete as directed by the federation officers and as per standard specifications.
Supply and filling with M Sand for foundation and basement to required thickness and in layers of not more than 15 cm thick, watered, well rammed and consolidated etc., complete as directed by the Federation Officers and as per standard specifications.
Supplying and filling with conveyed Gravel from approved source of supply for foundation and basement to required thickness and in layers on not more than 30 cm thick, watered ,well rammed and consolidated etc., complete as directed by the Federation officers and as per the technical Specifications.
Plain Cement Concrete 1:4:8 using 40 mm size HBG stones for foundation including de-watering if found necessary and laid in layers of not more than 15 cm thick for flooring including rendering the top surface rough to take floor finish including side shuttering if required and compaction ,curing etc., complete as directed by the Federation officers and as per the technical Specifications
Brick work in CM 1:5 (one cement & five sand) using II class ground moulded bricks of size 9" x 4½" x 3" including finishing, curing,etc., complete as directed by the federation officers and as per standard specifications.
Supply, fabricating and placing in position of reinforcement grills for all RCC works including cost of steel rods, binding wires, labour for bending, cutting and tying etc., complete as as directed by the federation officers and as per standard specifications.
Supplying, erecting steel centering using M.S. Sheet of size 90X60cm and BG 10 gauge stiffened welded with M.S. angel of size 25X25X3mm laid over silver osk/country wood joist of size 10X6.5cm spaced at about 90cm centre to centre and supported by casurinaprops of 10 to 13cm dia spaced at 75cm center to centre for all type of RCC roof slab, lintel beam,T,L,beam landing slab plinth beam, grade beam, column footing, column , sunshade, facia, sloped roof, waist slab, etc., Including necessary supports with all cross bracings filling slits and holes in the surfaces(the retrieved materials should be taken back by the contractor) and side shuttering etc., complete as directed by the Federation officers and as per standard specification-Upto Basement (plain surface)
Upto Basement (column surface)
above basement(column surface)
above basement(plain surface)
Reinforced Cement Concrete 1:1 1/2:3 (One Cement, One and half hard broken stone jelly and three part m.sand) using 20 mm gauge machine crushed hard broken granite stone jelly for all RCC items of works excluding cost of reinforcement grill and fabricating charges, centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc. complete complying with standard specification and as directed by the departmental officers -Upto Basement
above Basement
Plastering the surface of walls with Cement Mortar 1:5 (One cement and Five M sand), 12mm thick in all floors including scafolding , curing etc., complete complying with standard specification and as directed by the departmental officers.
Supply and Painting ( Exterior / Interior) two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, scaffolding wherever required etc., complete complying with standard specification.
Supplying, fabricating and erection of MS Trusses complying with standard specifications. including anchor & connection bolt as specified in the deawing, welding as per IS 816, of approved quality and colour after sand blasting with necessary hire charges of crane, hoisting, equipments, rope charges etc, complete in all respects as directed by the federation officers.
Supply and painting new iron work with 2 coats of anti-corrosive synthetic enamel paint of approved quality and colour over priming coat etc..complete complying with standard specification and as directed by the departmental officers.
Supply and fixing of a concrete ring for a size of 0.90 m dia and height 0.30 m with 1 no of concrete cover slab with a size of 0.9 m dia, 10 cm thickness etc., it including material, labour charges etc.,Complete as directed by the federation engineers and as per standard specification
Supply and fixing of RCC Man hole cover (1000 mm dia) its including labour, transportation charges etc.,complete as directed by the Federation Engineers and as per standard specification.
Supply and fixing 100mm PVC pipe (having working pressure 6 kg. / sq.cm) with necessary specials etc. etc, complete as directed by the federation officers and as per standard specification
Supplying and laying interlocking Paver Block of 83mm thick approved design made out of 6 - 10mm thick HBGS chips in cm 1:2:4 properly occurred to attain the required strength laying the Rubber Moulded Paver Block over a sand cushion of 10cm thick and well compacted using 1-3 tonne capacity of manufacturing the inter locking blocks , loading, transportation , unloading and other incidential charges etc. complete complying with standard specification
Clearing the bushes, debris in the adjacent sides and rear side of the qc laboratory and levelling the site by using earth movers Machine, including cost of driver batta, disel charges,machine charges, transportation etc... complete as directed by the Federation Engineers and as per standard specification.
Dismantling brick work by using power drilling machine and clearing the debris away from our campus etc… complete as directed by the federation officers and as per standard specification
Brick partition wall in CM 1:3 (one part cement and three parts sand), Including labour charges etc complete as instructed by the federation engineers and as per standard specification.
Supply and fixing in position with powder coated MS roofing sheet 0.47mm thick corrugated of approved make for roofing with air vent . The rate including the laps with necessary bolt nut screw etc complete as instructed by the federation engineers and as per standard specification.
Supplying and fixing of Aluminium Sliding doors with partially panelled / Glazed with necessary fixtures hinges,rubber gasket, screws and fixing clips etc., including necessary filling up of gaps at junctions, at top, bottom and sides with sealent etc., Bottom 900mm height shall be with Prelaminated both side Bison lam sheet (Cement Particle Board) fixed to shutter. The door shall be provided with Aluminium handle, door closer, stopper, towerbolt, locking arrangement etc., The cost and conveyance of all materials to site and all labour charges etc., complete as instructed by the federation engineers and as per standard specification.
Hire charges of crane for removing and re arranging of existing concrete slab in the entrance of state central laboratory building for an area of 37.50sqm it include machinery charges,labour and transport charges etc...complete as instructed by the federation engineers and as per standard specification.
GST (Note: The tenderer should quote the amount towards Goods and Service tax (GST) in the appropriate columns in terms of percentage (%). If not quoted, it will be considered that the rate quoted is inclusive of GST.)
SAI AJAY BUILDERS
SAI SAKTHI AND CO
PPSandCo
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .