| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹35.0 L+₹2.1 L (6.35%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹35.1 L+₹2.2 L (6.70%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹35.7 L+₹2.8 L (8.58%)Rejected-Finance WZ 484 M S BLOCK HARI NAGAR NEW DELHI 110064 | NEW DELHI | NEW DELHI | DELHI | 110064 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹36.0 L+₹3.1 L (9.40%)Rejected-Finance 11A LAXMI VIHAR BANDHAN PALACE WALI GALI MODIPURAM MEERUT UTTAR PRADESH 250110 | MEERUT | UTTAR PRADESH | 250110 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
17 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE GAYA
Garrison Engineer Gaya Paharpur Mil Stn Gaya Bihar, PIN-823005
Repair/replacement of LT overhead lines, UG cables and other allied work at zone of Mil Stn Gaya
2024_MES_661290_2
8006/GE/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer Gaya Paharpur Mil Stn Gaya Bihar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GAYA
₹60,000
Yes
16 Nov 2024
2 Sept 2024
19 Sept 2024
2 Sept 2024
17 Sept 2024
4 Sept 2024
Amount
Taking down old UNSV ACSR conductor, any type and size from the poles and supply and fixing new ACSR conductor including stringing on LT poles complete including aluminium binding wires, jumpering, bindings at insulators etc, complete, all as specified and directed.
M&L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red color and fixed with MS clamps, bolts and nuts of approved size, for LT 20x15mm size.
M&L for anti-climbing device, spikes type fabricated out of MS bars (round,square and flat) including nuts, bolts, washer and welding in two halves made to shape to suit the cross section of the pole.
Supply and fixing of shock treatment chart as per E-in-C's pattern size 2 feet x 4 feet aluminium board with alluminium frame & glass with housing arrangments all as directed.
Supply and fixing in repairs end termination (Heat shrinkable) joint kit suitable for 1.1 KV UG XLPE cable of size 70 to 185 Sqmm 3.5 core.
Supply and fixing in repairs end termination (Heat shrinkable) joint kit suitable for 1.1 KV UG XLPE cable of size 185 to 300 Sqmm 3.5 core.
Taking down existing old unserviceable and supply and fixing PVC flat twin core LT cable size 4 Sqmm, 2 core keeping aside for reuse/removal from trenches/ wall/pole complete all as specified and directed.
Dismantling old unsv and S&F Stay assembly complete with accessories as shown in electrical plate No-1 (loop type insulator, stay clamps, excavation and concrete measured separately) with stay rod 16mm dia, MS plate 6mm thick size 230x230mm, complete, all as specified and directed.
Replacement old unsv and S&F Electric rubber hand gloves 33 KV
Taking down existing old unserviceable underground LT cableSupply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area 16 Sqmm 4 core complete all as specified and directed.
All as per item No. 10 here-in-before but for cross sectional area 25 Sqmm 3.5 core complete.
All as per item No. 10 here-in-before but for cross sectional area 50 Sqmm 3.5 core complete.
All as per item No. 10 here-in-before but for cross sectional area 70 Sqmm 3.5 core complete.
All as per item No. 10 here-in-before but for cross sectional area 95 Sqmm 3.5 core complete.
All as per item No. 10 here-in-before but for cross sectional area 120 Sqmm 3.5 core complete.
All as per item No. 10 here-in-before but for cross-sectional area 240 Sqmm 3.5 core complete.
All as per item No. 10 here-in-before but for cross-sectional area 400 Sqmm 3.5 core complete.
Supply and fix in replacement of MCB 4pole isolater TPN 80 Amps capacity AC 415 Volts complete all as specified and directed
Taking down old unsv solar light and Supply and fixing LED solar light fitting 24 watt including galvanized steel pole in built, lithium ion battery, solar panel charge controller with dusk down sensor complete
Supplying & Laying in replacement of synthetic rubber insulated mats 3.0mm thick for voltage upto 33 kv size 2 meter long 1 meter width (2x1m) as required at site complete all specified and directed.
Dismantling old unsv and Supply, installing, testing & commissioning of LT sheet metal enclosure outdoor type dust & Vermin proof (duly painted with powder coating 6 tank process). Cable lugs are to be used to terminate cables/wires, and necessary connections all as directed by Engineer-in-Charge, self supporting fabricated out of CRCA steel sheet 3.15 mm thick, of size (1000x700x350) with base mounted on angle iron frame (40x40x4 mm) incldg 4 Legs 60 cms long made of angle iron (40x40x4 mm) grouted 30 cms below ground with PCC 1:2:4, cubicle type comprising of following:- (a) Onload Changeover Switch 200 Amps, 4 pole - 01 Nos. (b) Digital Volt meter, AC, single phase 0-500 volt 48x96 mm, 3 1/2 digit, -03 Nos. (c) Digital Amp meter, AC, 0-100 Amps 48x96 mm, 3 1/2 digit incldg CT (100 : 5), -03 Nos. (d) Digital frequency meter, AC, single phase 50 Hz, 48x96 mm, 3 1/2 digit, -01 Nos. (e) Aluminium bus bar 400 amps rating
Supplying & fixing in replacement of connection/junction box made out of 1.6mm thick MS sheet front openable, weather & vermin proof including painting two coats of synthetic enamel paint over a coat of red primer connection box shall be suitable for housing & including aluminium bus bar 25 Amps cap - 2 Nos, MCB SP 6 Amps- 01 No and having provision of cable hole in bottom for two to three cables of size 16 Sqmm 4 core armoured cable connection box shall be fitted on street light pole and fixing arrangements i.e. MS clamps etc deemed to be provided by the contractor, size of box - 200 x 150 x 100mm, complete, all as directed.
Dismantling old unsv and Supplying & fixing in replacement of double walled corrugated HDPE duct pipe of 63 mm outer dia confirming to IS-14930 (Part-II) of approved colour with fittings for cable protection complete all as specified and direcetd.
Dismantling old unsv and Supply and erecting steel tubular swaged type pole 410 SP 31 (9 mtr long) including foundation complete with cast iron /MS base plate of size 300mmx300mmx6mm continously welded at the centre of the pole and MS cap at the top of the pole all as specified including factory painted with two coats of black bituminous paint internally throughout and externally for embedded portion and applying of two coats of aluminium paint over a coat of red oxide primer above 1.5 mtr from GL and making of size 30 cm wide of black and white synthetic enamel paint alternately upto 1.5 m from ground level complete all as specified.
M & L PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate as in foundation of poles.
M & L for PCC 1:3:6 type C2 using 40mm graded stone aggregate as in copping/collar of poles and foundation of stay assembly etc complete all as specified and directed.
M & L for PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in copping of poles including taking down old PCC copping of poles all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for foundation etc or for shafts, wells, cesspits, manholes, pier holes, etc n exc 10 sqm on plan and not exc 1.5m in depth and getting in hard/dense soil complete all as specified and directed by Engr-in-charge
Returning filling in with approved excavated soil including spreading levelling watering and well ramming in layers not exceeding 25cm thick, complete, all as specified and directed.
Removing of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
Burnt bricks sub class 'B' laid flat dry across the cable for cable protection all as specified and directed.
Sand cushioning to UG cable 8cm thick before laying the cable and 15cm above the cable, stretching and testing of cable complete all as specified and directed. Note:(i) Consolidated / Punned sand shall be considered for purpose of payment (ii) Sand shall be same as specified for plastering work.
Supply & fix in replacement of MCCB 4 Pole 'C' series 630 amps capacity AC 415 V,35kA complete all as specified and directed.
Supply and fix in replacement of MCCB 4 pole 400 Amps 36 KA capacity AC 415 Volts complete all as specified and directed.
Supply and fix in replacement of MCCB 4 pole 200 Amps 36 KA capacity AC 415 Volts complete all as specified and directed. .
Supply and fix in replacement of MCCB 4 pole 160 Amps 36 KA capacity AC 415 Volts complete all as specified and directed.
Supply and fix in replacement of MCCB 4 pole 100 Amps 25 KA capacity AC 415 Volts complete all as specified and directed
M&L for renewal of earthing of poles/system with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick, buried vertically in ground not less than 2.25 metres below ground level with top edge of the plate not less than1.5 mtr below ground level, connected to GI strip 32x6mm by means of nuts, bolts and washers and encased in and inclduing 40mm dia GI light grade pipe upto 2.4 mtr height from ground level fixed by MS flat iron clamp 40mmx5mm with nut, bolt and washers, GI strip fixed to base along pole and connected to existing system with alternate layers of charcoal dust, salt packed around plate 150mm thick including watering GI pipe, medium grade 20mm dia, 1.5mtr long fixed to funnel with wire mesh complete with PCC chamber and RCC chamber cover all as per electrical plate No. 3 SSR part I-2009 including excavation and earth work in any type of starta and testing on completion. (Note:- GI strip and GI pipe beyond 7.5M long shall be measured and paid separately)
S & F illuminated display board with name of Electric supply installations (sub station) of size 1.25m x 0.2m x 0.9m (LxBxH) with flex of light blue (MES Colour) colour of letters shall be white, outer side fabrication bordered with aluminium angle frame of 25mmx25mmx3mm thick, inner side fabricated with 12mm MS square bar, 50mm dia GI Pipe medium grade shall be fixed both side of board with 2 nos 30mmx4mm thick MS Flat of 2m length welded to GI Pipe and nut bolt and washer with display board not less than 3m and PCC 1:2:4 type B1 for foundation including all internal wiring and illuminated with LED 20W Tubelight fittings 02 Nos including its fixing arrangement and written letters in capital, size of letters proportion with overall size of board complete all as specified and directed . Note: (i) Before manufacturing boards drawing and design of board including colour of board shall be approved by Engr-in-Charge (ii) Each board display name shall be given seperately.
M/S VIKAS CONSTRUCTION CO. (BID ID -3092012)
BISHWNATH KUMAR BHARTI (BID ID -3092457)
MS HARI MOHAN GUPTA (BID ID -3092224)
SINGHAL ENTERPRISES (BID ID -3092188)
MAA BHAGWATI TELECOM LINK (BID ID -3092199)
BEHL ENGINEERS AND TRADERS (BID ID -3092065)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .