Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-AOC | L1 | Accepted-AOC Being the lowest | |
| 2 | L2₹30.4 L+₹8.0 L (35.8%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹32.7 L+₹10.3 L (46.0%)Rejected-Finance B 33 171 PATEL NAGAR GURUDASPUR ROAD PATHANKOT 145001 | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Not being lowest |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
17 Jan 2022, 6:00 pmClosed
GE, Minniebay Port Blair
GE, Minniebay, Junglighat (PO), Port Blair -744103
REPAIR / REPLACEMENT OF STREET LIGHT AND CONNECTED WORKS UNDER AGE E/M I AT GE MINNIEBAY, PORT BLAIR
2021_MES_488994_2
8102/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
GE, Minniebay, Junglighat (PO), Port Blair -744103
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE Minniebay Port Blair
₹58,000
Yes
22 Mar 2022
24 Dec 2021
25 Jan 2022
24 Dec 2021
17 Jan 2022
3 Jan 2022
Amount
M&L for taking down carefully defective street/security light fittings of any wattage any make from street light pole and re-fixing the light fittings in original position after repair /change of driver including necessary checking of connection and removing the oxidization from connection as required including testing complete all as specified and directed Note : Spare required for servicing shall be measured and paid separately as supply only
Supply only electronic LED Driver 150W complete all as specified and as directed
Supply only electronic LED Driver 90/72W complete all as specified and as directed
Supply only electronic LED Driver 36/40W complete all as specified and as directed
Supply only electronic LED Driver 24/25W complete all as specified and as directed
Taking down carefully defective flood light fittings of any wattage any make from shade /powerhouse building / Main Gate and re-fixing the light fittings in original position after repair /change of driver including necessary checking of connection and removing the oxidization from connection as required including testing complete all as specified and directed
Supply only electronic LED Driver 60/70W for flood light complete all as specified and as directed
Supply only electronic LED Driver 120/150W for flood light complete all as specified and as directed
Supply only electronic LED Driver 200W for flood light complete all as specified and as directed
Taking down carefully defective Gate light fittings of any wattage any make from gate/post and re-fixing the light fittings in original position after repair /change of driver including necessary checking of connection and removing the oxidization from connection as required including testing complete all as specified and directed
Supply only electronic LED Driver 35/40 suitable for gate lights complete all as specified and as directed
Taking down carefully defective Bollard light fittings of any wattage any make from garden and re-fixing the light fittings in original position after repair /change of driver including necessary checking of connection and removing the oxidization from connection as required including testing complete all as specified and as directed
Supply only electronic LED Driver 10/12W suitable for bollard light complete all as specified and as directed
Supply only electronic LED Driver 18W suitable for bollard light complete all as specified and as directed
M& L for preparation to internal and external old steel surface of LT Feeder Pillar Box/ Panel Boards of various size and completely removal of existing treatment by scraping or chemical and surface painted with DUCO paint with help of spray gun over a coat of red oxide primer complete all as specified and as directed
M& L for repair of LT Feeder Pillar Box/ Panel Boards made out of 2.00 mm thick mild steel sheet fixed to existing frame and painted with DUCO paint with help of spray gun over a coat of red oxide primer including taking out to existing warn out shutter frame and fixed with minimum two hinges to existing frame complete all as specified and directed.
Taking down of PCC any grade complete all as specified and as directed
M&L cement concrete in foundations filling and mass concrete of B1 grade with using 20 mm aggregate (1:2:4) complete all as directed.
M&L for PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in coping/collar of poles including necessary form work complete all as specified
S&F in replacement of MCB 40 Amps, TP, 415 volt, breaking capacity 16 KA conforming to IS 13647-II complete all as specified and as directed
S&F in repairs aluminium cable lugs for fixing of armored cables in panels complete all as specified and as directed for the following sizes of cables:-
S&F in repairs Copper cable lugs for fixing of armored cables in panels complete all as specified and as directed for the following sizes of cables :-
S&F in repairs Cable gland of LT UG cables in panels for complete all as specified and as directed for the following sizes of LT UG cables :-
Supply and laying in trenches, fixed on walls, passing through pipes, jointing and testing of electric LT cables, PVC insulated, PVC sheathed, galvanised steel strip or wire armored electric power cables with stranded aluminium conductors 1100 Volts grade including taking up / down old unsv cable complete all as specified and as directed for the following size :- Note: The rates should be includes in Cable lugs, Cable Gland and joint kit (if required).
4 Core 6 Sqmm
4 Core 10 Sqmm
4 Core 16 Sqmm
3.5 Core 25 Sqmm
Taking down / up and re-laying of serviceable cable of XLPE insulated, PVC bedded, Galvanized steel strip or wire armored underground heavy duty electric power cable with stranded aluminium conductor 1100 volts grade, laid in trenches / duct with saddling / on pole including all necessary fixing arrangement such as lugs, glands end termination etc of size 10 Sqmm to 25 Sq mm complete all as specified and as directed
Supply & Laying of DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 40 mm and inner dia 32 mm polyethylene including coupler & Bend with smooth internal and profiled external surface for non pressure under ground cable including taking down / up old unsv pipes complete all as specified and as directed
Taking down / up and re-laying of DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of 40 mm and inner dia 32 mm polyethylene including coupler & Bend with smooth internal and profiled external surface for non pressure under ground cable complete all as specified and as directed
S&F in replacement of GI pipe of medium grade 40 mm dia with all fitting / fixture for fixing on wall and road crossing etc. complete all as specified and as directed
Excavation in trenches any type of soil (soft/loose/hard/dense) not exc 1.5 mtr wide and not exc 1.5 mtr in depth for foundation, pipe, laying of cable etc not exc 10 Sqmtr on plan and not exc 1.5 mtr in depth and getting out complete all as specified and as directed
Returning filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil all as specified and as directed
Removing excavated surplus soil to a distance not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meters above the starting point all as specified and as directed
M&L for road cutting, removing of material , returning filling and PCC 1:2:4 using 20mm graded stone aggregate for laying of LT UG cable /Galvanised Iron Pipe/Rex Pipe all as specified and as directed
Fault finding of LT UG Cable including excavation , returning refilling after rectification of fault with fixing of Straight through joint kit, extra UG Cable and DWC (Double Wall corrugated) HDPE pipe complete all as specified and as directed Note:- LT UG Cable, Straight through joint kit and DWC (Double Wall corrugated) HDPE pipe measured and paid separately here and before of items.
S & F in repairs cable jointing kit for 1100Volt grade cable for Straight through, heat shrinkable type joint complete with jointing materials and accessories suitable for LT, XLPE armored aluminium conductor cable of size 10 to 25 Sqmm 3.5 core complete all as specified and as directed
Re-routing of power cable on wall /cable duct of size 10 to 25 Sqmm with saddling with aluminium pati with required size of screw complete all as specified and as directed
S&F in replacement IP 66/ 67 thermoplastic-polycarbonate cable junction box of size 205X255X92 with terminal which is totally shock proof, water proof, halogen free, silica and having internally embedded gasket technology fixing on pole / surface / frame with the help of GI clamp of size 25X3 mm ,one no of MCB SP 6 Amp and four way 32 Amp Connector complete all as specified and as directed
S&F in replacement IP 66/ 67 thermoplastic-polycarbonate cable junction box of size 130X180X77 with terminal which is totally shock proof, water proof, halogen free, silica and having internally embedded gasket technology fixing on pole / surface / frame with the help of GI clamp of size 25X3 mm ,one no of MCB SP 6 Amp and four way 32 Amp Connector complete all as specified and as directed
M&L for Painting to Steel tubular poles 9 m long with one coat of Synthetic enamel paint black/yellow combination Zebra marking up to 1 m from ground level / copping remaining Job portion painting with one coat of aluminium paint including preparation of old painted surfaces and painting the pole terminal etc. and numbering of pole with PVC printed round sheet containing one letter and one number and fixing with two nos of self drill GI Screw to pole complete all as specified and as directed
M&L for Painting to RCC poles 9 m long with one coat of Synthetic enamel paint black/yellow combination Zebra marking up to 1 m from ground level / copping remaining Job portion painting with one coat of aluminium paint including preparation of old painted surfaces and painting the pole terminal etc. and numbering of pole with PVC printed round sheet containing one letter and one number and fixing with two nos of self drill GI Screw to pole complete all as specified and as directed
S&F of GI tubular swaged poles complete with GI base plate finial taper plug, bolts, nuts and screws, with two holes for drawing conductor between pole box to street light fitting all as specified type 410 SP-31 of height 9M including necessary Earth work,PCC foundation copping etc and refixing of all existing fitting fixture exist in old electric pole complete all as specified and as directed
Supply and laying 2.5 Sq.mm (nominal area) PVC unsheathed multi stranded copper conductor PVC insulated 1100 volt FR grade twin core cable drawn through CPVC Pipe not less than 20 mm dia for connecting the street light fittings complete all as specified and as directed
Supply and fix GI bracket for street lights made out of medium grade GI pipe 40mm dia, 1.5 mtr long bend to shape as directed, fixed on poles with two Nos GI clamp of size 40 x 6mm flat iron suitable for steel tubular pole including suitable GI nuts and bolts washers complete all as specified and as directed
S&F in repairs energy efficient street light luminaries LED type 90 watts, IP66 ,230volts, 50 Hz , in deep drawn aluminium housing and cast aluminium pipe mounting attachment including suitable heavy duty electronic driver also driver should withstand 265 volts, 125 lumen/watt and complete accessories, pre-wired and connection complete with suitable size of stranded copper flexible conductor complete all as specified and as directed
S&F in repairs energy efficient solar street light all in one with lithium battery LED type of 30 watts, IP 65 in built motion sensor colour temp 6500, 125 lumen/watt complete all as specified and as directed
S&F in repairs energy efficient street light luminaries LED type 72 watts,IP66 ,230volts, 50 Hz , in Deep drawn aluminium housing and cast aluminium pipe mounting attachment including suitable heavy duty electronic driver also driver should withstand 265 volts, 125 lumen/watt and complete accessories, pre-wired and connection complete with suitable size of stranded copper flexible conductor complete all as specified and as directed
S&F in repairs service wire Al Conductor Weather Proof 6 Sqmm 2 core complete all as specified and as directed
S&F in repairs service wire Al Conductor Weather Proof 10 Sqmm 2core complete all as specified and as directed
S&F rubber insulation tape 25cm width 2.5 Mtr long fixing of connection make water proof outside the electrical equipments and also fixing the underground cable where crack arises outside complete all as specified and as directed
S&F in repairs LED 35 watt Post top energy saving environmental friendly ,design with symmetrical light distribution, spun aluminium landscape luminaries made in cast aluminium spigot housing and IP 65 protection, 125 lumen/watt including necessary connections complete all as specified and as directed
S&F in repairs LED 10 Watt, 125 lumen / watt Bollard light made in cast aluminium spigot housing withdecorativecleare opal arcylicdiffuser and IP 65 protection including necessary connections complete all as specified and as directed
S&F in repairs LED 40 watt Post top energy saving environmental friendly ,design with symmetrical light distribution,cleare landscape luminaries(CDL) made in cast aluminium spigot housing and IP 65 Protection, 125 lumen / watt including necessary connections complete all as specified and as directed
M & L for danger notice board of PVC sheet , printed with letters, figures ( English, Hindhi,Tamil) and conventional skull and bones in signal red colour and fixed with GI. clamps, bolts and nuts of approved size for LT/HT of suitable size including taking down old unsv notice boards complete all as specified and as directed
M&L for earthing with galvanised earth plate electrode 600 mm x 600 mm x 6 mm thick, buried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to galvanised iron strip 32 mm x 6 mm by means of GI Welding made out of galvanised iron mild steel and 40 mm dia GI pipe "light grade" for protection of earth lead and connected to control board or transformer neutral earth or as directed including earthing pit in PCC (1:3:6) type C-1, pre-cast reinforced cover with MS XPM Jalli, RCC 1:1.5:3 cover slab of size 300 x 300 x 100 mm with one handle made out of 8 mm dia round bar 20 mm dia GI pipe light grade for watering funnels , wire mesh and provided charcoal or coke of alternative layers of 15 cm including necessary earth work complete shown in electrical plated No 3 and testing complete including taking down old unsv earthing including necessary connections complete all as specified and as directed NOTE : (i) The earthing pit should be provided with proper earth pit and pit cover. Pit cover should be painted with synthetic enamel paint of approved colour and pit number to be marked on a GI plate above 45 cm from GL (ii) If the desired earth resistance is not achieved during testing as per IS, the complete earthing shall replaced by the contractor at his own cost and no extra claim shall be admissible.
S&F in repairs of Aluminium earth continuity conductor or main earthing lead fixed to wall above 11 mtr or rooftop of 3 rd floor or recess or any other indicated situation for loop earthing etc. as required for 25 mm x 3mm thick, aluminium using porcelain clit/post insulators, complete all as specified and as directed
S&F in repairs MCB SP 6 Amps including necessary connections and testing complete all as specified and as directed
S&F in repairs LED 50 watt flood light energy saving environmental friendly ,design with symmetrical light distribution, luminaries efficiency of 125 lumen/watt and IP 66 Protection, fixing on roof top of bldg / 11 mtr pole / high mast pole including necessary connections complete all as specified and as directed
S&F in repairs LED 80 watt flood light energy saving environmental friendly ,design with symmetrical light distribution, luminaries efficiency of 125 lumen/watt and IP 66 Protection fixing on roof top of bldg / 11 mtr pole / high mast pole including necessary connections complete all as specified and as directed.
S&F in repairs LED 100 watt flood light energy saving environmental friendly ,design with symmetrical light distribution, luminaries efficiency of 125 lumen/watt and IP 66 Protection fixing on roof top of bldg / 11 mtr pole / high mast pole including necessary connections complete all as specified and as directed
S&F in repairs LED 150 watt flood light energy saving environmental friendly ,design with symmetrical light distribution, luminaries efficiency of 125 lumen/watt and IP 66 Protection fixing on roof top of bldg / 11 mtr pole / high mast pole including necessary connections complete all as specified and as directed
S&F in repairs LED 200 watt flood light energy saving environmental friendly ,design with symmetrical light distribution, luminaries efficiency of 125 lumen/watt and IP 66 Protection fixing on roof top of bldg / 11 mtr pole / high mast pole including necessary connections complete all as specified and as directed
S&F in repairs LED 250 watt flood light energy saving environmental friendly ,design with symmetrical light distribution, luminaries efficiency of 125 lumen/watt and IP 66 Protection fixing on roof top of bldg / 11 mtr pole / high mast pole including necessary connections complete all as specified and as directed
S&F in repairs digital Timer with Analog time ,contactor pre wired Distribution Board complete time lite 40A 3 Pole 415 V complete as specified and directed
M&L for cutting vegetation and surface dressing not exceeding 15 cm deep including removing the materials to a distance not-exc 60 mtr complete all as specified and directed
M&L for welding of two MS/GI Sheet / Pipes on site including grinding the welded portion and made smooth surface complete all as specified and as directed
S&F in repair of SPD of 5 KV in junction box complete all as specified and as directed
M&L for wiring of unserviceable timer panel box complete and replacement of existing size of copper wire and copper lugs and testing complete all as specified and as directed
S&F in repairs contactors of capacity 40 A 3 Pole 415 V with 2NO+2NC complete all as specified and as directed
S&F in repair NO/NC of capacity 40A of 415 V complete all as specified and as directed
SHUSHANT ASSOCIATES
KAPOOR AUTOMOBILES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .