Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.5 LAccepted-AOC PO LEKHAPANI DIST TINSUKIA PIN 786 180 ASSAM | 786180 | L1 | Accepted-AOC DUE TO L1 RATE | |
| 2 | L2₹22.9 L+₹1.3 L (6.10%)Rejected-Finance NO 1 RANGAJAN VILLAGE PO BOKULONI CHARIALI MAUZA TIPLING SUB DIVISION TENGAKHAT DIST DIBRUGARH ASSAM 786191 | DIBRUGARH | ASSAM | 786191 | L2 | Rejected-Finance DUE TO HIGHER RATE | |
| 3 | L3₹24.3 L+₹2.7 L (12.6%)Rejected-Finance | L3 | Rejected-Finance DUE TO HIGHER RATE | |
| 4 | L4₹24.4 L+₹2.8 L (12.9%)Rejected-Finance | L4 | Rejected-Finance DUE TO HIGHER RATE | |
| 5 | L5₹25.1 L+₹3.5 L (16.4%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | L5 | Rejected-Finance DUE TO HIGHER RATE |
Tender Value
₹23.9 L
EMD Value
₹47,800
Closing Date
1 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE LEKHAPANI
TINSUKIA, ASSAM
SPL REPAIRS TO ELECTRICAL LT POLES, CABLES AND ALLIED WORKS DUE TO STORM AT ZONE-IVB AT LEKHAPANI MIL STN UNDER GE LEKHAPANI
2022_MES_540339_2
8673/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE LEKHAPANI
Class E and category b (i)
4 documents required · 4 mandatory
₹500
GE LEKHAPANI
₹47,800
Yes
12 Oct 2022
17 Sept 2022
6 Oct 2022
17 Sept 2022
1 Oct 2022
24 Sept 2022
Amount
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m depth for laying of cables, pipes,foundations, etc and getting out in soft/loose soil complete all as specified and directed.
All as per item No. 1 above, but depth exceeding 1.5 mtr and not exceeding 3 mtr complete all as specified and directed.
Returning, filling, including spreading, levelling, watering and well ramming in layers not exc 25 cms of soil complete all as specified and directed.
Removing the surplus excavated materisl/soil to a distance not exc 50 mtrs and depositing, where directed at a level not exceeding 2.5 Mtr above the starting point all as specified and directed.
Supply and spread sand for cushioning of cables complete all as specified and directed. Note: Punned thickness only will be measured and paid.
Supply and lay old burnt sub class 'B' bricks as in trenches, complete all as specified and directed.
S&F GI tubing 80 mm bore, (light grade), galvanised, ISI marked with all specials for cable protection on road crossing/floor etc duly sealed at both ends complete all as specified and directed.
S&F GI tubing 50 mm bore, (light grade), galvanised, ISI marked with all specials for cable protection on road crossing/floor etc duly sealed at both ends complete all as specified and directed.
S&F GI tubing 40 mm bore, (light grade), galvanised, ISI marked with all specials for cable protection on road crossing/floor etc duly sealed at both ends complete all as specified and directed.
M&L Providing PCC (1:4:8) type D2 (using using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete in complete all as specified and directed.
M&L Providing PCC (1:3:6) type C1 (using 20 mm graded crushed stone aggregate) as in coping including necessary form work and finishing exposed surface/white washing complete all as specified and directed.
M&L Providing PCC (1:2:4) type BO (using 12.5 mm graded crushed stone aggregate) as in kerbs or mud stops, round or chamferred on edges complete all as specified and directed.
Supply,laying,testing and commissioning of XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 volts grade with glanded aluminium conductor of size 3.5 core 95 sqmm passing through pipe/wall/floor/trenches complete all as specified and directed.
All as per Item No. 13 above but size 3.5 core,50 sqmm complete all as specified and directed.
All as per Item No. 13 above but size 4 core,25 sqmm complete all as specified and directed.
All as per Item No. 13 above but size 2 core,6 sqmm complete all as specified and directed.
M&L for Providing Heat shrinkable LT straight through joining kit including materials all as required for LT cable of size 3.5 core 95 sqmm complete all as specified and directed.
All as per item No 17 above but of size 3.5/4 core 25 sqmm to 50 sqmm, complete all as specified and directed.
All as per item No 17 above but size 2/3.5/4 core,6/10 sqmm up to 16 sqmm, complete all as specified and directed.
S&F Cable route indicator oval shaped size 200mm x 150mm x 6mm thick CI with letter embossed as HT/LT UG cable fixed on 25mmx 25mmx 6mm MS angle iron of 50 cms long embedded in PCC block 200mmx 200mm x 200mm by using PCC (1:3:6) type C1 (using 20mm graded stone aggregate) including 2 coats of synthetic enamel paint over a coat of zinc chrome primer on exposed surface complete all as specified and as directed.
M&L for fabrication, testing and commissioning of factory made LT panel board made out of CRCA sheet 3.15 mm thick Outdoor type size 1000x1000x450mm, double door type totally enclosed with front opening hinged doors with canopy sloped top projected and Plinth mounted , weather and water proof as per IS-8623 Aluminium bus bar with phase and neutral, insulators suitable for 3 phase 4 wire LT AC, 50HZ, 433 volts, 300 Amps, capacity complete with necessary locking arrangement and measuring devices such as volt meter , ammeter, power factor meter including painting with two coats of synthetic enamel paint over a coat of primer red oxide internal electric connections as required with suitable size stainless steel cable glands for incoming and outgoing cables including taking down old unserviceable feeder pillar box of any size and provision of the following:- (a) MCCB 100 Amps, fixed thermal magnetic release type, 25 kA, AC 50 Hz, 4 pole - 01 No (Incoming) (b) MCCB 63A, fixed thermal magnetic release type, AC 50 Hz, 25KA , 4 pole - 3 Nos (outgoing) (c) MCB SPN 32 Amps, AC 50 Hz - 02 Nos (d) Indication lamp (R,Y,B), LED type, with toggle switches - Set of 3. (e) Multi-function meter, three phase, digital type, with parameters like voltage, ampere, Frequency, PF, KW, KVA etc, - 01 No.
M&L for fabrication, testing and commissioning of factory made Feeder Pillar Box made out of CRCA sheet 3.15 mm thick Outdoor type size 900x900x450mm, double door type totally enclosed with front opening hinged doors with canopy sloped top projected and Plinth mounted , weather and water proof as per IS-8623 Aluminium bus bar with phase and neutral, insulators suitable for 3 phase 4 wire LT AC, 50HZ, 433 volts, 200 Amps, capacity complete with necessary locking arrangement and measuring devices as given below, including painting with two coats of synthetic enamel paint over a coat of primer red oxide internal electric connections as required with suitable size stainless steel cable glands for incoming and outgoing cables incl taking down unsv old feeder pillar and provision of the following:- (a) MCCB 100 Amps, fixed thermal magnetic release type, AC 50 Hz, 10 KA, 4 pole - 01 No (Incoming) (b) MCCB, 63 Amps, 4 Pole, 415 Volts, AC, fixed thermal magnetic release type, breaking capacity 10 KA-02 Nos. (c) Digital type time switch-01 No connected with 01 x Contactor 40 Amps, 3 pole, 415 volts and 01 x auto/manual toggle switch. (d) Indication lamp (R,Y,B), LED type, with toggle switches - Set of 3. (e) Multi-function meter, three phase, digital type, with parameters like voltage, ampere, Frequency, PF, KW, KVA etc, - 01 No.
M & L for Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to GI earth strip size 25x4 mm as earth lead connected to earth plate by means of nut, bolts, check nut & washer of galvanized iron or of steel, GI earth wire will be protected by 40 mm dia GI pipe 'light grade', watering pipe 40 mm dia GI 'light grade', GI wire meshed funnel, alternate layer of char coal and salt on all side to earth plate upto thickness of 150 mm, filling of black cotton soil in earth pit upto ground level, PCC chamber recessed for and including RCC cover including all necessary excavation and earth work, earth wire connected to main switch board, testing the earthing after completion all as specified and shown in electric plate No 3 of MES SSR Part-I 2009,complete all as specified and as directed .
S&F Energy effecient LED street light fitting 60 watt complete with high power LEDs as light source with peanut lens for uniform distribution, prewired, and mounting GI pipe bracket of suitable size with 2 x clamp sets with nut/bolt/washers including taking down old light fittings complete all as specified and directed.
M & L for steel tubular swaged pole 410 SP-31 (9.0 metre long) including CI base plate, finial taper plug, bolts, nuts & screws as per IS 2713 Part -I & II including painting with two coats of aluminium paint over a coat of red oxide zinc chrome primer on exposed portion and making strips of width 30 cm upto 1.5 m from the ground level in black and yellow shade in alternate layer including numbering of poles using two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer and two coats of anticorrosive paint over a coat of red oxide primer to embedded portion of pole including making good to match existing area complete all as specified and as directed.
S&F FRP body loop in loop out enclosure of size 200 mm x 140 mm x 95 mm consisting of HD bakelite connector strip including MCB 6 Amps SPN fixing of enclosure with pole/wall using 40 x 6 mm size MS FI clamps of required shape with bolts, nuts and washers complete all as specified and directed.
S&F PVC insulated Aluminium conductor cable of twin core of size 2.5 sqmm drawn through and including PVC rigid conduit not less than 20 mm dia fixed along pole with suitable size clamps for connecting street light fittings from Junction box complete all as specified and directed.
Dismantling concrete poles/ struts, any size and transportation to store yard for stacking complete all as directed by Eng-in-charge.
Dismantling of ACSR conductors and jumpers from LT OH lines/structures complete all as directed by Eng-in-charge.
Dismantling cross-arms of M.S. channel or angle sections etc. complete all as directed by Eng-in-charge.
Dismantling LT insulators any type, any size complete all as directed by Eng-in-charge.
M&L Stay assembly complete with stay rod 16 mm dia and all accessories as shown in electrical plate No 1 of SSR Part I (2009) including 01 x loop type insulator and stay clamp all as specified and directed. Note :- Excavation and PCC will be measured and paid separately.
S & F Aluminium Bus bar chamber of capacity 63 Amps, four pole, 415 volts, AC supply, mounted on DMC type insulators, totally enclosed with Metal body/rigid PVC enclosure, complete including opening for cable entry,etc complete all as specified and directed. .
M&L Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of size 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
M/S SINGH TRADERS
RC CONSTRUCTION
AFTAB ENTERPRISES
STANDARD ELECTRIC WINDERS
M/s GANDHESWAR PHUKAN
FREEZCON
MAZUMDAR ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .