GARRISON ENGINEER I GOS
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
REPAIR/MAINT OF CENTRIFUGAL PUMP SETS MONOBLOCK PUMP SETS SUBMERSIBLE PUMP SETS FILTRATION PLANTS DESALINATION PLANT INCLUDING CERTAIN BR WORKS AT GMS UNDER GE I GOS
2021_MES_443925_1
8000/04/21-22/0903/E8
Open Tender
Civil Works
Item Rate
180 days
GOPALPUR ON SEA
PLEASE REFER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER I GOS
₹90,000
Yes
6 Aug 2021
19 May 2021
14 Jun 2021
19 May 2021
11 Jun 2021
4 Jun 2021
Amount
Demolition of cement concrete un reinforced in ground floor and paving n exc 15cm thick (below or above ground level) complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring average 25 mm thick surface finished even and rough (as in levelling course) to receive the topping layer complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off premises complete all as specified and directed.
M&L for non skid ceramic coloured tiles of design as approved 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed.
M&L for non skid ceramic coloured tiles of design as approved 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed.
M&L for glazed ceramic coloured tiles 350 x 250 x 7 mm / 450 x 350 x 7 mm thick on vertical surface such as dado / skirting / risers to steps etc jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including rendering 10 mm thick in cement mortor 1:4 complete all as specified and directed. Note- (i) The size of tiles (except thickness) may be varied during execution without any price adjustment.
M & L coloured vitrified tiles Light shade 10 mm thick (square/rectangular) polish area of each tiles n exc 0.36 Sqm coloured cut to required size set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles as in floor incl 15 mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L coloured vitrified tiles 10 mm thick (square/rectangular) polish area of each tiles n exc 0.36 Sqm coloured cut to required size set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles but in vertical surfaces incl 10 mm thick rendering in CM 1:3 complete all as specified and directed.
Taking down cement or cement lime plaster, of any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) complete all as specified and directed.
M&L for rendering 5 mm thick in CM 1:3 on RCC ceiling surface and finished even and smooth with out using extra cement complete all as specified and directed .
M&L for applying 2mm thick Birla / JK Putty in two layers on newly plastered walls surfaces making absolutely even and smooth, rubbing with sand paper complete all as specified and directed
M&L for applying two coats of oil bound distemper on wall or concrete surfaces over & including a coat of primer on prepared surfaces including, rubbing with sand paper complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying three coat of white wash complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceilings and applying three coat of white wash complete all as specified and directed.
M & L for two coats of cement based paint over a coat of primer on new plastered surface of walls including preparation of surface complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs /blankets, any thickness, including cover fillets complete all as specified and directed.
S&F 12 mm thick plain Gypsum Board False Ceiling with GI frame including all necessary drilling cutting to fix electric items complete all as specified and directed with following:- (a) GI Grid channel 30x25x20 mm of 24 gauge fixed with rawl plug and screw 450 mm centre to centre alongwith perimeter walls. (b) GI channel made to shape 50x40x40 mm of 24 gauge placed @ 600 mm centre to centre from perimeter at wall except long wall (in one span). (c) GI intermediate runners of size 45x10x10 mm of 24 gauge fixed @ 1200 mm centre to centre leaving frame of one side walls (in other span). (d) GI sheet 25 mm wide and 20 mm gauge suspended fixed with steel fastner to roof ceiling and 1200 mm centre to centre including pluging of RCC Slab. (e) 12 mm thick gypsum board filling joints with POP and finishing complete with two coat of plastic emulsion paint over one coat of primer on ceiling.
S&F in replacement of MCCB 3 pole , 415 V , fixed type 25 to 100 Amp with breaking capacity 16 KA , panel mounting type , AC complete all as specified and directed. Make – CG/HAVELL’S/ L&T/C&S or equivalent
S&F in replacement of MCCB 3 pole , 415 V , fixed type 160 Amp with breaking capacity 36 KA , panel mounting type , AC complete all as specified and directed. Make – CG/HAVELL’S/ L&T/C&S or equivalent
S&F in replacement of MCCB 4 pole , 415 V , fixed type 160 Amp with breaking capacity 36 KA , panel mounting type , AC complete all as specified and directed. Make – CG/HAVELL’S/ L&T/C&S or equivalent
S&F in repair Star Detla Timer 0-30 Seconds duration complete all as specified and directed. Make : L&T/Havell's/C&S or equivalent
S&F in replacement CT Coil 60/5 Amps complete all as specified and directed. Make : L&T/AE or equivalent
S&F in replacement CT Coil 30/5 Amps complete all as specified and directed. Make : L&T/AE or equivalent
S&F in replacement of MCB TP 40 amps, complete all as specified and directed. Make – CG/HAVELL’S/ L&T/C&S or equivalent
S&F in replacement gun metal NRV of size 50 mm dia complete all as specified and directed. Make : Kirloskar/Leader/Upadhyay or equivalent
Carrying out Chemical analysis test of water collected from bore wells through Govt approved lab complete all as specified and directed.
M&L for 5 micron 20 inch long jumbo micron catridge filter complete all as specified and directed .
M & L for Overhauling/Backwash & cleaning of the Desalination Plant at GMS with Citric Acid-10 kgs and 5 Micron Catridge Filter-04 nos complete all as specified and directed . NOTE: Every Overhauling/Backwash will be measured separately as each Job
S&F in replacement of low/high voltage monitoring device 440 volts, 3 phase complete all as specified and directed. Make- EAPL/L&T./Minilec or equivalent
S&F in replacement of phase monitoring device 440 volts, 3 phase complete all as specified and directed. Make- EAPL / L&T/Minilec or equivalent
S&F in replacement of Dry run & over load protection with phase failure relay alongwith suitable CTS complete all as specified and directed. Make : EAPL/MINILEC or equivalent
S&F in replacement of electronic adjustable cyclic timer complete all as specified and directed. Make : EAPL /L&T/Minilec or equivalent
S&F in replacement of Voltmeter digital type (0-500V) complete all as specified and directed. Make : AE/L&T/HPL or equivalent
S&F in replacement Ammeter digital type (0- 100 Amps) complete all as specified and directed. Make : AE/L&T/HPL or equivalent
Taking down old unserviceable and Supply and fixing submersible pump, electric driven 415 v, TP suitable for 200/250 mm dia bore well (Casing pipe size 200/250 mm)supply and install 3 HP, 40 mtr Head,105 LPM, 38mm outlet (Model KS4C- Series Make :Kirloskar/CRI including lowering by manpower & mechanicalcomplete all as specified and directed. NOTE: The Unsv. Pumpsets will be Deposited to the AGE E/M Store yard .
Taking down old unserviceable and Supply and fixing submersible pump, electric driven 415 v, TP suitable for 200/250 mm dia bore well (Casing pipe size200/250mm)supply and install 5 HP, 75 mtr Head,180LPM, 50mm outlet (Model KS6B- Series Make :Kirloskar/CRI including lowering by manpower & mechanical complete all as specified and directed. NOTE: The Unsv. Pumpsets will be Deposited to the AGE E/M Store yard .
Dismantling the power supply of electric motor any type including dismantling from pump and taking to workshop with necessary transportation and opening the complete motor and rewinding the rotor with super enameled copper wire as per the existing gauge with necessary insulation, sticks and varnishing, including replacement of shaft bearing 02 Nos and motor terminals plate/cable ducts complete of capacity 30 HP including painting complete all as specified and directed.
All as per Item No. 39 above but of capacity 20 to 25 HP electric motor any type.
All as per Item No. 39 above but of capacity 10 to 15HP electric motor any type.
All as per Item No. 39 above but 5 to 7.5 HP electric motor any type.
All as per Item No. 39 above but 1 to 3 HP electric motor any type. Note : for item No 39-43 :- Pump/Motor shall be dismantled and winding shall be tested continuity at site if winding fail/burnt is established than winding shall be cut at site before issuing gate pass. The quoated rate deemed to included .
Dismantling of submersible motor upto 7.5 HP 3 phase from pump house at any location in GMS area under AGE E/M GOS Yard, transporting to contractors workshop, dismantling and carrying out necessary repairs/replacement of motor as per the following :- (a) Cutting out existing winding of starter of submersible motor of any make and rewinding with same size of copper winding wire as existing as directed by the EIC. (b) Straightening the slot of starter of submersible motor of any make (c) Replacement of thrust washer and bearing complete of submersible motor of any make. (d) Replacement of worn-out bushes of submersible motor as per manufacturers design and specification. (e) Replacement of sand guard (f) Providing of sleeves in end plate of submersible motor (g) Replacement of cable gormmet (h) Replacement of water seal (i) Replacement of studs with nuts (j) Lathe work of motor shaft, turning to bring it to original size and shape and plastering of shaft of submersible motor for smooth functioning on described amps
All as per Item No.44 above but of capacity upto 5 HP
All as per Item No.44 above but of capacity upto 3 HP Note for item No 26 to 28 :- Pump/Motor shall be dismantled and winding shall be tested continuity at site if winding fail/burnt is established than winding shall be cut at site before issuing gate pass. The quoted rate deemed to included .
Dismantling of submersible pump upto 7.5 HP capacity from pump house at any location in GMS area under AGE E/M GOS Yard, transporting to contractors workshop, dismantling and carrying out necessary repairs/replacement of pumps/Testing as per the following:- (a) Replacement of coupling complete (b) Overhauling of submersible pump and carrying out the following repairs. (c) Lathe work including balancing of pump shaft and cutting of key slots (d) Re-threading of worn-out studs holes and providing over size studs with nuts (e) Replacement of bowel bushes (f) Replacement of neck ring (g) Replacement of steel distance pieces (h) Replacement of bowel (j) Replacement of head extension
S&F in Replacement of impeller upto 7.5 HP of submersible pump set complete all as specified and directed.
Dismantling complete Centrifugal /Mono Block pump set of any type and overhauling the pump re-threading of wornout holes of studs and providing over size studs with nuts & washers. Rematlling and balancing of shaft, replacement of gunmetal bush bearing and gland packing of pump set. and refitting the same after the repair/replacement duly complete all as specified and tested for smooth functioning of capacity 30 HP
All as per Item No. 49 above but capacity 20 to 25 HP
All as per Item No. 49 above but capacity 10 to 15 HP
All as per Item No. 49 above but capacity 5 to 7.5 HP
All as per Item No. 49 above but capacity 1 to 3 HP
Disconnecting the electric connection and taking out the submersible pump set from bore / open well upto 7.5 HP including GI column pipe complete and lowering down repaired motor with column pipe, welding joints and connecting electrical connection as directed and transportation of submersible pump set upto 7.5 HP 3 phase from pump house to any location in GMS area to contractors work shop repaired pump set for relowering, dismantling and carrying out necessary repairs complete aii as specified and directed
S&F in Replacement of old rusted GI Column Pipe heavy grade of size 65 mm dia in pieces of 3.3 metre long , lathe m/c threaded both ends in the bore/open wells complete all as specified and directed. Make –Tata/Jindal or equivalent
All as per Item No. 55 above but of 50 mm dia
S&F in Replacement of old rusted heavy grade GI socket of size 65 mm dia complete all as specified and directed.
All as per Item No. 57 above but of 50 mm dia
S&F in repair PVC insulated submerssible cable water proof flate type 3 core with standed copper conductor cable, 4 Sqmm, 1100 volts grade including cable lugs/joints, connection to submerssible motor and other end to aluminium armoured cable including jointing complete all as specified and directed. Make: Finolex /Polycab/Plaza or equivalent
S&F in repair HDPE Borecaps of size 200/250mm dia complete all as specified and directed.
S&F in repair of steel rope in submersible bore wells from motor to top edge of the bore well of size 6 mm dia(multi wire stainless steel) for holding of submersible pump motor set complete all as specified and directed.
Supply and replacement of contactor 16 Amps capacity 2 NO + 2 NC, AC 3 phase 415 Volts, 50 HZ complete all as specified and directed. Make – CG/L&T/BCH/ HAVELL’S/Seimens or equivalent
All as per Item No. 62 above but 25 Amps capacity.
All as per Item No. 62 above but 32/35 Amps capacity.
All as per Item No. 62 above but 40/50 Amps capacity.
Taking down old unserviceable and Supply and fixing Monoblock pump sets , electric driven ,Three phase suitable for suction and delavery line size 100x100 mm, supply and install 30 HP (22KW ), (Model SRF 3085/3095 , Make : kirloskar complete fitting and testing ,alignment of motor , complete all as specified and directed. NOTE: The Unsv. Pump sets will be Deposited to the AGE E/M Store yard .
Taking down old unserviceable and Supply and fixing submersible pump, electric driven 230 v, single phase suitable for 200/250 mm dia bore well (Casing pipe size200/250mm)supply and install 1 HP ( 0.75 KW ), 80 mtr Head,0.6 cum/hr, 38mm outlet (Model CORA 75 + UMAI ( S ) of size 20B / 15 + 0.75 / 22 Make :KSB or in Eqvt including lowering by manpower & mechanical complete all as specified and directed. NOTE: The Unsv. Pumpsets will be Deposited to the AGE E/M Store yard .
Taking down old unserviceable and Supply and fixing submersible pump controller single phase 1 HP , 240 V , 50/60 HZ , start capacitor : 120-150 MFD , Coil voltage 240 V , Run capacitor : 1 x 36 MFD and relay range : 6-10 A of Cat No . SS97721 of L&T Make or Eqvt including necessary connections complete all as specified and directed.
S&F in replacement of DOL starter for submersible pump set type MK-I and relay range 9-14 amps with contactor complete all as specified and directed. Make : C&S/L&T/CG or equivalent
S&F in replacement thermal over load relay of range 6.5 to 10 Amps complete all as specified and directed. Make- CG/L&T/ BCH/C&S or equivalent
All as per Item No. 70 above but 15 to 22 Amps capacity.
All as per Item No. 70 above but 24 to 34 Amps capacity.
S&F in replacement of indicating lamp set (RYB) LED type complete all as specified and directed.
S&F in replacement FRP Sand /Activated carbon vessel,size 36"x72",volume 1020 ltrs capacity make PENTAIR/TATA/ULTIMA as per suitable at site complete all as specified and directed. Note :- Supply only for various sizes of Sand filter Media is paid and Measured separately .
Supply only Sand filter Media of size 3/4 - 1/2 inch of mesh size
Supply only Sand filter Media of size 4 - 8 inch of mesh size
Supply only Sand filter Media of size 8 - 16 inch of mesh size
Supply only Sand filter Media of size 16 - 32 inch of mesh size
Supply only Carbon filter Media of size 3/4 - 1/2 & 4-8 inch of mesh size
Supply only Carbon filter Media of size 8 - 16 inch of mesh size
Supply only Activated Carbon
S&F in replacement of FRP Membrane housing , size 4080 2E(Double element) complete all as specified and directed. Make : PENTAIR/ULTIMA/SHARK or equivalent
S&F in replacement of TOP Fitting for vessel of size 36"x72", complete all as specified and directed.
S&F in replacement of BOTTOM Fitting for vessel of size 36"x72", complete all as specified and directed.
S&F in replacement of PRESSURE GAUGE 0-10 KG Pressure,complete all as specified and directed. Make : warree/fibig/shark or equivalent
S&F in replacement of PRESSURE GAUGE ,21 KG Pressure,complete all as specified and directed. Make : warree/fibig/shark or equivalent
S&F in replacement of Online conductivity / TDS meter ,complete all as specified and directed. Make : Astral or equivalent
S&F in replacement of CI Victalic Coupling size 25 mm , complete all as specified and directed.
S&F in replacement of Air Release Valve, complete all as specified and directed.
S&F in replacement of Flow indicator of size 25 mm range -10-5000 ltrs , complete all as specified and directed.
S&F in replacement of Micron Catridge Filter housing complete all as specified and directed.
S&F in replacement of UPVC Pipe line of size 50 mm bore complete all as specified and directed.
S&F in replacement of UPVC Pipe line of size 40 mm bore complete all as specified and directed.
S&F in replacement of UPVC Pipe line of size 25 mm bore complete all as specified and directed.
S&F in replacement of UPVC Pipe line of size 15 mm bore complete all as specified and directed.
S&F in replacement of gate valve of size 50 mm bore complete all as specified and directed.
S&F in replacement of gate valve of size 40 mm bore complete all as specified and directed.
S&F in replacement of gate valve of size 25 mm bore complete all as specified and directed.
S&F in replacement of gate valve of size 15 mm bore complete all as specified and directed.
Dismantling the power supply of High Speed electric motor for Desalination including dismantling from pump and taking to workshop with necessary transportation and opening the complete motor and rewinding the rotor with super enameled copper wire as per the existing gauge with necessary insulation, sticks and varnishing, including replacement of shaft bearing 02 Nos and motor terminals plate/cable ducts complete of capacity 30 HP high speed motor including painting complete all as specified and directed.
Dismantling complete Centrifugal Plunger high speed pump set capacity 30 HP of any type and overhauling the pump re-threading of wornout holes of studs and providing over size studs with nuts & washers , Rematlling and balancing of shaft, replacement of gunmetal bush bearings and gland packing of pump set including changing of sleeves , packing , oil seal and water seal and refitting the same after the repair/replacement duly by the changing of plungers , pistons rod assembly and replacing of gear oil complete all as specified and tested for smooth functioning of capacity 20 TPD Desalination plant Note :- Supply only for Plungers and Piston rod assembly,Oil seal ,Gland packing is paid and Measured separately .
Supply only plungers suitable size and as per required at site
Supply only Piston rod assembly as suitable size and as per required at site
Supply only Oil Seal as suitable size and as per required at site
Supply only Gland packing as suitable size and as per required at site
Discoonecting and Taking down Sand Pressure filter system from Water supply Installation for removing old media of various sizes / type and cleaning completely by using brushes , rectified of any leakage by new technology method , providing of new insulation at internal / externally , checking of foundation / vibration , using of painting and Refixing in same position and also filling of new media for the following sizes / type including providing new pipe line / fittings of any type & size and operating system handle unit complete all as specified and directed. Note :- Supply only for various sizes of Sand filter Media is paid and Measured separately .
M/S JAGANNATH SASMAL
M/s Bapujee Builders and Traders
M/s MAA BHAIRABI ENTERPRISES
M/s Ats Electricals
M/S K MURALIDHARA PATRA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .