GE Sri Ganganagar
Garrison Engineer Sri Ganganagar, Military Engineer services , Sri Ganganagar Cantt Rajasthan-335001
REPAIRS AND MAINT OF WATER COOLER AND AIR CONDITIONER AND REFRIGERATOR AND DEEP FREEZER AND WINTER APPLIANCES AND ALLIED WORKS AT MILITARY STN SRI GANGANAGAR
2022_MES_526731_1
GE SGNR/ TOK-12 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Sri Ganganagar
E Class c(i) for un-enlisted, refer NIT para 8
6 documents required · 6 mandatory
₹500
GE Sri Ganganagar
₹20,000
Yes
7 Jul 2022
27 May 2022
27 Jun 2022
27 May 2022
25 Jun 2022
4 Jun 2022
Amount
Disconnecting, dismantling and taking out existing burnt out compressor from the water cooler and S & F of new Hermetic sealed unit compressor along with OLP & starting relay of capacity 1 ton suitable for water cooler of cooling capacity 150 litres per hour including necessary gas charging complete all as specified and directed by Engineer-in-Charge. Make : KIRLOSKAR/ CARRIER/ TECUMESH)
Disconnecting, dismantling and taking out existing burnt out compressor from the water cooler and S & F of new Hermetic sealed unit compressor 1/2 HP along with OLP & starting relay of capacity 1 ton suitable for water cooler of cooling capacity 60 litres per hour including necessary gas charging complete all as specified and directed by Engineer-in-Charge. Make : KIRLOSKAR/ CARRIER/ TECUMESH)
Disconnecting, dismantling and taking out existing burnt out compressor from the water cooler, S & F of new Hermetic sealed unit compressor 1/3 HP along with OLP & starting relay of capacity 1 ton suitable for water cooler of cooling capacity 40 litres per hour including necessary gas charging complete all as specified and directed by Engineer-in-Charge. Make : KIRLOSKAR/ CARRIER/ TECUMESH)
S& F in replacement fan motor with Capacitor starter and blade, single phase, AC, 50 HZ suitable for water cooler of cooling capacity 40/60 litres per hour including fittings on existing MS plate and making connection complete all as specified and directed by Engineer-in-Charge. . Make : POLAR/KHAITAN/COOL HOME.
S& F in replacement fan motor with Capacitor starter and blade, single phase, AC, 50 HZ suitable for water cooler of cooling capacity 150 litres per hour including fittings on existing MS plate and making connection complete all as specified and directed by Engineer-in-Charge. Make : POLAR/KHAITAN/COOL HOME.
M&L for rewinding of fan motor with super enameled copper winding wire of adequate size and gauge as per existing winding including insulating material, varnish drying, baking etc for water cooler of capacity 150 litres per hour complete all as specified and directed by Engineer-in-Charge.
M&L for rewinding of fan motor with super enameled copper winding wire of adequate size and gauge as per existing winding including insulating material, varnish drying, baking etc for water cooler of capacity 40 litres per hour complete all as specified and directed by Engineer-in-Charge.
S& F in replacement push cock CP brass 15 mm dia bore suitable for water cooler complete all as specified and directed by Engineer-in-Charge.
Cleaning/ flushing the unit with N2 gas and supplying and recharging the refrigerant gas in water cooler capacity 150 litres per hour including replacement of strainer complete all as specified and directed by Engineer-in-Charge.
Cleaning/ flushing the unit with N2 gas and supplying and recharging the refrigerant gas in water cooler capacity 40/60 litres per hour including replacement of strainer complete all as specified and directed by Engineer-in-Charge.
S& F in replacement starting relay suitable for water cooler of capacity 150 litres per hour complete all as specified and directed by Engineer-in-Charge.
S& F in replacement starting relay suitable for water cooler of capacity 40/60 litres per hour complete all as specified and directed by Engineer-in-Charge.
S& F in replacement copper tubing size3/5 mm dia for suction & discharge lines in water cooler complete all as specified and directed by Engineer-in-Charge.
S& F in replacement running capacitor 25 MFD oil filled suitable for water cooler of capacity 150 litres per hour complete all as specified and directed by Engineer-in-Charge. Make -USHA / KELTRON / SEATRON
S& F in replacement running capacitor 10/20 MFD oil filled suitable for water cooler of capacity 40/60 litres per hour complete all as specified and directed by Engineer-in-Charge. Make -USHA / KELTRON / SEATRON
S& F in replacement starting capacitor 80/100 MFD oil filled suitable for water cooler of capacity 150 litres per hour and making necessary electric connection complete all as per specified and directed by Engineer- in-Charge. Make :USHA / KELTRON/ SEATRON
S& F in replacement starting capacitor 40/60 MFD oil filled suitable for water cooler of capacity 40/60 litres per hour and making necessary electric connection complete all as per specified and directed by Engineer- in-Charge. Make :USHA / KELTRON/ SEATRON/Tib CAP
S & F in replacement thermostat switch complete with plate and screw suitable for water cooler of cooling capacity 150/60/40 litres per hours and making necessary electric connection complete all as specified and directed byEngineer -in-Charge. Make:RENUTROL/ DANFOSS/ HONEYWELL
S& F in replacement copper wiring kit complete suitable for water cooler of capacity 40/60/150 litres per hour and making necessary electric connection complete all as specified and directed by Engineer-in-Charge.
M&L for spray painting to water cooler of capacity 150 litres per hour with one coat of synthetic enamel paint including preparing the existing painted surface. Colour shall be as per existing shade complete all as specified and directed by Engineer -in-Charge.
M&L for spray painting to water cooler of capacity 40/60 litres per hour with one coat of synthetic enamel paint including preparing the existing painted surface. Colour shall be as per existing shade complete all as specified and directed by Engineer -in-Charge.
S& F in replacement PVC drain pipe25/ 32 mm bore heavy duty including clamp for water cooler complete all as specified and directed by Engineer-in-Charge.
M&L for welding and patch repair of bottom and side panel of water coolers including replacement of bottom MS Sheet of 16 gauge for mounting compressor and blower motors complete all as specified and directed by Engineer-in-Charge.
Disconnecting, dismantling and taking out existing burnt out compressor from the machine and S & F Hermetic sealed unit compressor along with OLP & starting relay as per existing model & make suitable for refrigerator of capacity 165/170 litres, suitable for operation on 280 volt AC supply including necessary gas charging complete all as specified and directed by Engineer-in-Charge.
Disconnecting, dismantling and taking out existing burnt out compressor from the machine and S & F Hermetic sealed unit compressor along with OLP & starting relay as per existing model & make suitable for refrigerator of capacity 280/300/310 & 320 litres of deep freezer, suitable for operation on 280 volt AC supply including necessary gas charging complete all as specified and directed by Engineer-in-Charge.
M&L for cleaning / Flushing the gas system with N2 gas and supplying and recharging the refrigerator of capacity 165 to 310 litres with refrigerant gas including replacement of strainer and compressor oil and rectification of leakage in the entire system complete all as specified and directed by Engineer- in- Charge.
S& F in replacement over load protector suitable for 310 / 286 / 165 litres capacity refrigerator & 300/320 litres deep freezer complete all as specified and directed by Engineer -in-Charge. Make : RENUTROL/ WHIRLPOOL / CLASSIC.
S& F in replacement thermostat switch with knob, plate and screws for automatic defrosting device suitable for 310/ 286/165 litres capacity refrigerator & 300/320 litres deep freezer complete all as specified and directed by Engineer-in-Charge. Make : INDFOS/ WHIRLPOOL/ KIRLOSKAR.
S& F in replacement of door gasket suitable for 310/286/165 capacity refrigerator & 300/320 litres capacity deep freezer complete all as specified and directed by Engineer -in-Charge.
M&L for spray painting to refrigerator of capacity 165 to 310 litres with one coat of synthetic enamel paint including preparing the existing painted surface complete all as specified and directed by Engineer -in- Charge.
M&L for welding and patch repair of bottom and side panels of refrigerators including replacement of bottom sheet 16 gauge for housing compressor all as specified and directed by Engineer -in-Charge.
S & F in replacement freezer including necessary capillary suitable for 165 litre capacity refrigerator complete all as specified and directed by Engineer -in-Charge.
S & F in replacement freezer including necessary capillary suitable for 286 to 300 litre capacity refrigerator complete all as specified and directed by Engineer -in-Charge.
S & F in replacement freezer including necessary capillary suitable for 310 to 325 litre capacity refrigerator complete all as specified and directed by Engineer -in-Charge.
S& F in replacement condenser coil/Tube set suitable for 310/ 286 litres capacity refrigerator and 300/320 litres capacity deep freezer complete all as specified and directed by Engineer -in-Charge.
S& F in replacement replacement condenser coil/Tube set suitable for 165/ 175 litres capacity refrigerator complete all as specified and directed by Engineer -in-Charge.
S & F in replacement of condenser coil set suitable for Window Type Air Conditioner of capacity 1.5 Ton as per existing size complete all as specified and directed by Engineer -in-Charge.
Disconnecting, dismantling and taking out existing burnt out compressor from the machine and S & F Hermetic sealed unit compressor of capacity 1.5/2 Ton including necessary gas charging complete all as specified and directed by Engineer-in-Charge. Make : KIRLOSKAR/CARRIER/TECUMESH
Disconnecting, dismantling and taking out existing burnt out compressor from the machine and S & F Hermetic sealed unit compressor of capacity 1.0 Ton including necessary gas charging complete all as specified and directed by Engineer-in-Charge. Make : KIRLOSKAR/CARRIER/TECUMESH)
M&L for rewinding of blower motor of any make single phase for exhaust fan fitted in window type air conditioner of capacity upto 1/1.5/2 ton with supper enameled copper winding wire of gauge & weight equal to existing and replacing gun metal bushes including taking out from the air conditioner and refixing in its original position after rewinding complete all as directed by Engineer -in- Charge.
Taking out air conditioner upto 1.5 ton capacity from its position, checking , removing the leakage from refrigeration and charging the refrigerant gas including replacement of strainers and injecting anti moisture dose, fixing in position after testing complete all as specified and directed by Engineer - in charge.
S& F in replacement starting relay suitable for window type air conditioners upto 1.5 ton capacity including making necessary connections and testing complete all as specified and directed by Engineer - in -Charge.
S& F in replacement over load protector suitable for window type air conditioners upto 1.5 ton capacity including making necessary connections and testing complete all as specified and directed by Engineer - in- Charge. Make : RENUTROL/USHA/ SHRIRAM
S& F in replacement starting capacitor 6 MFD oil filled, 230 volts for blower fan motor including making necessary connections complete all specified and directed by Engineer- in-Charge. Make : KELTRON/USHA/ TIBCAP
S& F in replacement thermostat switch protector suitable for window type air conditioners upto 1.5 ton capacity including making necessary connections and testing complete all as specified and directed by Engineer - in- Charge.
S& F in replacement copper wiring kit suitable for window type air conditioner upto 1/1.5/2 ton capacity and making necessary connections with brass thimbles complete all as specified and directed by Engineer - in- Charge.
S& F in replacement air filter for window type air conditioner as per sample suitable for capacity upto 1.5 ton complete all as specified and directed by Engineer - in- Charge.
S& F in replacement front grill of window type air conditioners upto 1.5 ton capacity as per model of the air conditioner complete all as specified and directed by Engineer - in- Charge.
Maintenance, servicing and testing of split type air conditioners of capacity 1 to 2 ton of any make by cleaning all dust and stand practice, then apply one coat of cleaning solution and clear with nylon brush over cooling coil of entire AC unit with pressure water in order to remove dust on cooling coil, condenser fins, blowing off dust from machines & air filters, checking and de-carbonizing all electric system, oiling, greasing of blower motor, checking and removing any vibration and leakage device for winter / summer to ensure cutting of compressor / heater in case of failure of blower motor and testing after fixing at site complete all as directed by Engineer - in- Charge.
Maintenance, servicing and testing of window type air conditioners of capacity 1 to 2 ton of any make by cleaning all dust and stand practice, then apply one coat of cleaning solution and clear with nylon brush over cooling coil of entire AC unit with pressure water in order to remove dust on cooling coil, condenser fins, blowing off dust from machines & air filters, checking and de-carbonizing all electric system, oiling, greasing of blower motor, checking and removing any vibration and leakage device for winter / summer to ensure cutting of compressor / heater in case of failure of blower motor and testing after fixing at site complete all as directed by Engineer - in- Charge.
Taking out unserviceable copper cable by disconnecting all the electrical connections and supply and fix new PVC sheathed copper cable 3 core 1.5 sqmm complete all as directed by Engineer - in- Charge. MAKE: FINECAB / FINOLEX / PLAZA.
S& F in replacement industrial type sheet metal enclosure with metal clad plug and socket single phase with a two pin and earth plug & socket complete rated 240V 30 Amps capacity controlled by and including 01 No 30 Amps MCB SP 9 KA rupturing capacity complete all as directed by Engineer - in- Charge.
Taking down the unserviceable printed circuit board (PCB) disconnecting of electrical connection and supply and fix new printed (PCB) of 1.5/2TR capacity and reconnecting the same with electrical connections for split type AC complete all as directed by Engineer - in- Charge.
Taking down the unserviceable printed circuit board (PCB) disconnecting of electrical connection and supply and fix new printed (PCB) of 1.5/2TR capacity and reconnecting the same with electrical connections for window type AC complete all as directed by Engineer - in- Charge.
S& F in replacement copper pipe 1/2" capacity suitable for 1.5 TR window type Air conditioners complete all as directed by Engineer - in- Charge.
S& F in replacement copper pipe 3/8" capacity suitable for 2.0 TR window type Air conditioners complete all as directed by Engineer - in- Charge.
S& F in replacement copper pipe for 1/4" capacity suitable for 3.0TR window type Air conditioners complete all as directed by Engineer - in- Charge.
Taking down unserviceable metallic fan blade of blower motor for split type air conditioners of 1.5 / 2 TR capacity complete all as directed by Engineer - in- Charge.
Taking down electric water heaters (geysers) of capacity 25 Litres storage type, disconnecting of electric and water connections, taking out inner shell from outer cover, removing the thermostat switch, geyser element and geyser assembly, cleaning the inner shell (copper) with Mack solution including thermostat, geyser assembly and heating element, testing the inner tank for any leakage and rectification by soldering / brazing. Re - assembling the geyser and mounting on the grouted bolts and connecting with electric and water supply system and testing complete all as specified and directed by Engineer-in-Charge. (Note : Inner Shell, outer Cover, thermostat switch, geyser element and geyser assembly, bottom covers shall be measured and paid as supply only separately , if replaced as required).
Taking down electric water heaters (geysers) of capacity 50 Litres storage type, disconnecting of electric and water connections, taking out inner shell from outer cover, removing the thermostat switch, geyser element and geyser assembly, cleaning the inner shell (copper) with Mack solution including thermostat, geyser assembly and heating element, testing the inner tank for any leakage and rectification by soldering / brazing. Re - assembling the geyser and mounting on the grouted bolts and connecting with electric and water supply system and testing complete all as specified and directed by Engineer-in-Charge. (Note : heating plate assembly, heating element, thermostat switch and glass wool shall be measured and paid as supply only separately , if replaced as required).
Supply only, heating plate assembly apparatus plate with PVC rubber ring suitable for 25 litres capacity water heater complete all as specified and directed by Engineer-in-Charge. (Make : As per model of Geyser.)
Supply only, heating plate assembly apparatus plate with PVC rubber ring suitable for 50 litres capacity water heater complete all as specified and directed by Engineer-in-Charge. (Make : As per model of Geyser.)
Supply only, heating element round/triangle type, 1500 watt of suitable shape and size, confirming to ISI with rubber washers, with clamps complete all as specified and directed by Engineer-in-Charge. (Make : DASPASS / THERMOKING /MICRON/HOT TOP.
Supply only, heating element round/triangle type, 2000 watt of suitable shape and size, confirming to ISI with rubber washers, with clamps complete all as specified and directed by Engineer-in-Charge. (Make : DASPASS / THERMOKING /MICRON/HOT TOP.
Supply only, thermostat switch suitable for storage type geysers complete all as specified and directed by Engineer-in-Charge. (Make :BAJAJ/SPHEREHOT/RACOLD / TTE.
S & F in replacement, heating element push type, 1500 watt of suitable shape and size, conforming to ISI with rubber washers, with clamps complete all as specified and directed by Engineer-in-Charge. (Make :DASPASS / THERMOKING /MICRON/HOT TOP.
S & F in replacement, heating element push type, 2000 watt of suitable shape and size, conforming to ISI with rubber washers, with clamps complete all as specified and directed by Engineer-in-Charge.(Make :DASPASS/THERMOKING /MICRON/HOT TOP.
S & F in replacement thermostat switch suitable for storage type geysers complete all as specified and directed by Engineer-in-Charge. (Make :BAJAJ/SPHEREHOT/RACOLD / TTE.
M & L for glass wool for insulation and packing around the inner shell of geysers complete all as specified and directed by Engineer-in-Charge.
S & F in replacement, PVC connection wire woven 15mm size with nickel plated brass adapter, both sides threaded, in standard length of 450mm to suit the size of geysers complete all as specified and directed by Engineer-in-Charge.
M & L for spray painting to geysers of 25 litres capacity with one coat of synthetic enamel white paint externally after preparation of surfaces including writing MES numbers with black paint in 25mm font size letters, complete all as specified and directed by Engineer-in-Charge.
M & L for Spray painting to geysers of 50 litres capacity with one coat of synthetic enamel white paint externally after preparation of surfaces including writing MES numbers with black paint in 25mm font size letters, complete all as specified and directed by Engineer-in-Charge.
S & F in replacement, 3 core flexible copper conductor cable of size 2.5 sq mm complete all as specified and directed by Engineer-in-Charge. (Make : HAVELLS/ FINOLEX/ NICCO/ L& T/ANCHOR/RR CABLE/KEI
S & F in replacement, solar plate made out of toughened glass of size 200cm x 103cm, thickness 6mm as per existing model complete all as specified and directed by Engineer-in-Charge.
S & F in replacement, solar heating element with inbuilt thermostat of 3000 Watt as per existing model complete all as specified and directed by Engineer-in-Charge.
S & F in replacement, air release valve (weight type) as per existing model suitable for solar water heater complete all as specified and directed by Engineer-in-Charge.
M & L for lagging to 15mm bore galvanized iron tubing used in internal water supply or plumbing all round with 25mm thick banded mineral wood preformed “SNAPON” pipe sections of density 144 Kg/Cum conforming to IS-9842 including provision of chicken wire mesh netting 25 gauge, 20mm mesh and finally covered with 0.01mm aluminium foil complete all as specified and directed by Engineer-in-Charge.
M & L for lagging to 20mm bore galvanized iron tubing used in internal water supply or plumbing all round with 25mm thick banded mineral wood preformed “SNAPON” pipe sections of density 144 Kg/Cum conforming to IS-9842 including provision of chicken wire mesh netting 25 gauge, 20mm mesh and finally covered with 0.01mm aluminium foil complete all as specified and directed by Engineer-in-Charge.
S&F Voltage Stablizers for automatic operation single phase naturally air cooled indoor type & designed for input varition between 90 V to 300 V with output voltage satbilized at 230 v with accuracy of +/- 2.5 % can operate upto 12 Amp and above of capacity 5.0 KVA complete all as specified and directed by Engineer-in-Charge.
Dismantling and opening up the defective Voltage Stablizers of capacity 5.0 KVA single phase 220 V relay type of different makes, rewinding the main transformers with super enamelled copper wire best quality as per existing pattern with necessary insulating material complete, refixing, reconnecting and reassembling complete all as specified and directed by Engineer-in-Charge.
Dismantling and opening up the defective Voltage Stablizers of capacity 3.0 KVA single phase 220 V relay type of different makes, rewinding the main transformers with super enamelled copper wire best quality as per existing pattern with necessary insulating material complete, refixing, reconnecting and reassembling complete all as specified and directed by Engineer-in-Charge.
Dismantling and opening up the defective Voltage Stablizers of capacity 2.0 KVA single phase 220 V relay type of different makes, rewinding the main transformers with super enamelled copper wire best quality as per existing pattern with necessary insulating material complete, refixing, reconnecting and reassembling complete all as specified and directed by Engineer-in-Charge.
Dismantling and opening up the defective Voltage Stablizers of capacity 1.0/0.5 KVA single phase 220 V relay type of different makes, rewinding the main transformers with super enamelled copper wire best quality as per existing pattern with necessary insulating material complete, refixing, reconnecting and reassembling complete all as specified and directed by Engineer-in-Charge.
S & F in replacement, buck/boost relay rating 25 Amps as per existing pattern suitable for voltage stabilizers 5.0/3.0 KVA complete all as specified and directed by Engineer-in-Charge.
S & F in replacement, buck/boost relay rating 8/5 Amps as per existing pattern suitable for voltage stabilizers 1.0/0.5 KVA complete all as specified and directed by Engineer-in-Charge.
S & F in replacement, PCB assembly complete with necessary accessories suitable for 5.0/3.0 KVA capacity voltage stabilizers as per existing model complete all as specified and directed by Engineer-in-Charge.
S & F in replacement, Neon lamp indicator red colour in circular/rectangular shape as suitable and as per existing model complete all as specified and directed by Engineer-in-Charge.
S&F in replacement sheet steel powder coated paint enclosures, Single pole and earth, metal plug and socket including MCB, SP30 Amp 'B' curve 240 volts complete all as specified and directed by Engineer-in-Charge.
S&F MCB single pole 16 Amp (B-16) 240 volt with rupturing capacity not less than 10 KA complete all as specified and directed by Engineer-in-Charge.
S&F MCB single pole 32 Amp (B-32) 240 volt with rupturing capacity not less than 9 KA complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Non return Gun metal valve of 15mm bore ISI marked complete all as specified and directed by Engineer-in-Charge.
S & F in replacement GI union of 15mm bore, ISI marked complete all as specified and directed by Engineer-in-Charge.
S & F in replacement pressure release CP brass valve of 15mm bore ISI marked complete all as specified and directed by Engineer-in-Charge.
S&F in replacement, fastener mild steel 100 mm long x 10mm dia with pin and bolts complete for hanging of geyser and making good the disturbed surfaces including plastering and white washing complete all as specified and directed by Engineer-in-Charge.
S&F in replacement, fastener mild steel 150 mm long x 10mm dia with pin and bolts complete for hanging of geyser and making good the disturbed surfaces including plastering and white washing complete all as specified and directed by Engineer-in-Charge.
S&F in replacement, Rotational moulded polyethylene water storage tank 300 ltrs capacity (Cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed by Engineer - in - Charge. (Note : PVC tanks shall be ISI marked and having two layers and white colour )
S&F in replacement, Rotational moulded polyethylene water storage tank 500 ltrs capacity (Cylindrical vertical with closed top) hoisted and fixed in position complete all as specified and directed by Engineer - in - Charge. (Note : PVC tanks shall be ISI marked and having two layers and white colour )
S&F in replacement, GI tubing medium grade 15 mm bore laid in floor/roof including all GI fittings and cutting the existing pipe and making connection with new pipe including proper clamping with MS hooks complete all as specified and directed by Engineer - in - Charge. Make- TATA/JINDAL/BST
S&F in replacement, chromium plated Stop cock 15 mm dia external threaded complete all as specified and directed by Engineer - in - Charge.
S&F in replacement, chromium plated bib tap 15 mm dia complete all as specified and directed by Engineer - in - Charge.
S&F in replacement heavy duty rubber hose pipe 50mm dia 3mm thick 1.2m long suitable for solar water heater application complete all as specified and directed by Engineer - in - Charge. Make :- FLEX/POLY TUBE /ARSEN
M & L for painting to mellatic desert cooler any capacity with one coat of synthetic enamel paint inside and black bitumenus paint in side of bottom of water starage tank and balance portion synthetic enamel paint over a coat of red oxide primer including preparing the existing painted surface as per required patching works . Colour shall be as per existing shade complete all as specified and directed by Engineer -in-Charge.
M & L in replacement of old/burnt wiring for connection of equipments load bearable upto 1.5 Sqmm conductor with PVC conduit complete all as specified and directed by Engineer -in-Charge.
M & L in replacement of old/burnt wiring for connection of equipments load bearable upto 2.5 Sqmm conductor with PVC conduit complete all as specified and directed by Engineer -in-Charge.
Taking down copper/aluminium point wiring(light, fan, socket or power) complete, includingfixture and fittings such as switches, ceilingroses, pendants, regulators,socket, light fitting etc.removing materials to store for keeping in safe custodyor for taking credit (credit for above items should be made as perconditions separately) and making good disturbed surfaces of walls, floors, etc.complete all as specified and directed by Engineer -in-Charge.
M & L in replacement of UNSV/burnt One 3 Pin socket outlet 15 amps, independent with cables 4 Sqmm size. Make: Anchor or equivalent as approved by GE
S & F of sub-main wiring with two single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FR/FRLS stranded copper conductor drawn in and including steel dia 20mm “medium quality” conduit including 6 Sq mm (Nominal Area) copper cable as earth continuity conductor after chasing in wall and making good the disturbed surfaces and white wash or existing colour , necessary junction box and covers including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed by Engineer - in - Charge.
S&F cooler pad made of Khas-Khas suitable for desert coolers including taking out unserviceable pad complete all as specified and directed by Engineer - in - Charge.
Note : Amount of credit of Rs 49340.00 for retrieved materials is mentioned in Sch 'A' Section-II of tender documents in pdf form which will be deducted while acceptance of tender offline.
Ganganagar Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .