Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹34.3 L+₹2.0 L (6.12%)Rejected-AOC S NO 279 1 1A PLOT NO 113 KUTWAL COLONY SASTHE WASTI LOHEGAON PUNE 411 047 | PUNE | MAHARASHTRA | 411047 | L2 | Rejected-AOC L2 | |
| 3 | L3₹35.6 L+₹3.3 L (10.2%)Rejected-AOC | L3 | Rejected-AOC L3 |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
2 Jul 2020, 6:00 pmClosed
GE Panaji
GARRISON ENGINEER SV ROAD PANAJI GOA 403001
REPAIR/ REPLACEMENT OF EXTERNAL WATER SUPPLY DISTRIBUTION NETWORK INCLUDING REPLACEMENT OF OLD UNSERVICEABLE CI/GI PIPES, REPLACEMENT OF SLUICE VALVES, REPAIRS TO VALVE CHAMBERS AND CONNECTED WORKS AT BAMBOLIM MILITARY CAMP AND ALTINHO UNDER GE PANAJ
2020_MES_344121_2
8651/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE Panaji
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE Panaji
₹70,000
Yes
25 Jul 2020
11 Jun 2020
4 Jul 2020
11 Jun 2020
2 Jul 2020
18 Jun 2020
11 Jun 2020 - 15 Jun 2020
Amount
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of pipe line etc, and getting out in soft/ loose soil complete all as specified and directed.
Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in hard/ dense soil complete all as specified and directed.
Removing excavated surplus hard/ dense soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Taking up or down steel/PVC tubing and connections, for 15mm dia bore of pipes complete all as specified and directed.(Note: Excavation and earthwork shall be measured and paid for separately under relevant item of Schedule 'A').
All as per item No. 4 above but 20mm dia bore pipes
All as per item No. 4 above but 25mm dia bore pipes
All as per item No. 4 above but 32/40/50mm dia bore pipes
All as per item No. 4 above but 63/80/90mm dia bore pipes
All as per item No. 4 above but 100/110mm dia bore pipes
Refixing old steel/PVC tubing any length and connections in new or old position (walls, ceilings, floors or trenches), including replacing all the fittings with new as per site requirement for 15mm dia bores of pipes etc all as specified and directed.
All as per item No. 10 above but 20mm dia bore pipes
All as per item No. 10 above but 25mm dia bore pipes
All as per item No. 10 above but 40/50mm dia bore pipes
All as per item No. 10 above but 80mm dia bore pipes
All as per item No. 10 above but 100mm dia bore pipes
Supply and laying 20mm dia(outer) un-plasticised PVC water pipes of pressure rating 10 kgf/Sq cm. with and including all pipe fittings such as bends, elbows, tees, unions, reducing tees, adaptors, sockets, plugs, hose clips, nipples, short lengths etc. as required at site, laid in to walls, ceilings or in floors etc complete all as specified and directed.
All as per item No. 16 above but 25mm dia(outer) pipes
All as per item No. 16 above but 40mm dia(outer) pipes
All as per item No. 16 above but 50mm dia(outer) pipes
Supply and laying in repairs galvanized iron steel water tubing of medium grade 15mm dia bore with and including all fittings such as bends, elbows, tees, unions, nipples, short pieces etc as required at site, fixed to wall/ceiling etc complete all as specified and directed.
All as per item No. 20 above but 20mm dia bore pipes
All as per item No. 20 above but 25mm dia bore pipes
Supply and laying in repairs galvanised iron steel water tubing of medium grade 25mm dia bore with and including all fittings such as bends, elbows, tees, unions, nipples, short pieces etc as required at site, laid in trenches etc complete all as specified and directed.
All as per item No. 23 above but 40mm dia bore pipes
All as per item No. 23 above but 50mm dia bore pipes
All as per item No. 23 above but 80mm dia bore pipes
All as per item No. 23 above but 100mm dia bore pipes
Supply and fix gunmetal gate valves(heavy duty) 15mm dia bore, ISI marked with iron wheel head screwed at both ends for iron pipes including necessary fittings complete all as specified and directed.
All as per item No. 28 above but 20 mm dia bore pipes
All as per item No. 28 above but 25mm dia bore pipes
All as per item No. 28 above but 40mm dia bore pipes
All as per item No. 28 above but 50mm dia bore pipes
Supply and fix in repair Bib taps, cast copper alloy, chromium plated fancy type with crutch handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete including necessary GI fixing accessories like sockets, nipples, reducers, bends etc for 15 mm dia complete all as specified and directed
Supply and fix in repairs Ball brass valves, high pressure, with polythene float and flynut, aluminium rod screwed both ends and connected to ball complete, screwed for iron pipe or brass ferrule and fixed and tested complete suitable for 20 mm dia including necessary GI fittings required at site complete all as specified and directed.
All as per item No. 34 above but 25mm dia .
Burning out lead joint in position including removing old lead from 80mm bore of pipes complete all as specified and as directed.
All as per item No. 36 above but 100mm dia bore pipes
All as per item No. 36 above but 150mm dia bore pipes
All as per item No. 36 above but 200mm dia bore pipes
Material and labour for lead joint for CI pipe/DI pipe of 80mm bore dia including spun yarn etc for spigot & socket pipes and fittings complete all as specified and directed.
All as per item No. 40 above but 100mm dia bore pipes.
All as per item No. 40 above but 150mm dia bore pipes.
All as per item No. 40 above but 200mm dia bore pipes.
Supply and fixing in repairs sluice valves of 80mm dia both ends flanged with CI body and brass spindle with clamps and check nuts, operating wheel etc. non rising type ISI marked IS:14846 class PN 1.6 including connecting and testing , jointing materials complete all as specified and directed.
All as per item no. 44 above but 100mm dia bore pipes.
All as per item no. 44 above but 150mm dia bore pipes.
All as per item no. 44 above but 200mm dia bore pipes.
M & L for Construction of PCC solid Masonry valve chamber of size 1000 X 1000 X 1000 mm (Internal dimensions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate 150 mm thick and 150 mm wide off sets alround over 100 mm thick hard core , 200 mm thick PCC solid block walls built in CM 1:6, 50 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, without using extra cement internally including top of floor including necessary earth work excavation in hard/Dense soil, 3 mm thick MS sheet cover fixed on 25 mm X 25 mm X 6 mm thick angle iron frame work with hold fasts embedded in PCC coping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer ,disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
Taking up defective cast iron water mains (including all fittings) with spigot and socket ends and lead joints including burning out joints and recovering lead or flange ends etc of overhead/underground reservoir complete of size 150 mm dia pipes all as directed.
Taking up defective cast iron water mains (including all fittings ) with spigot and socket ends and lead joints including burning out joints and recovering lead or flange ends etc of overhead/underground reservoir complete of size 100 mm dia pipes all as directed.
Supply and fix 100 mm dia bore ductile iron pressure pipes, class K7, centrifugally cast with socket spigot ends as per following conforming to IS 8329/2000 with cement mortar lining inside the pipes with outside zinc coating suitable for push-on-joint (rubber gasket jointing) in any length including all jointing materials like tyton joints, gaskets etc required at site complete and making good for disturbed surfaces of roads, path ways etc while laying the pipe line at site, site clearance for route of pipe line, welding, cutting the existing CI/DI/MS pipe line of any size up to 200 mm dia for inserting branch connections etc all as specified and directed. Note: (i) Lead Joints / D-Joints will be measured and paid separately. (ii) Contractor is responsible for repair/replacement of any damages to the existing structures etc during the course of execution.
All as per item No. 51 above but 150mm dia bore pipes.
Material and labour for fittings for spigot and socket pipes such as Bends (any type, radius and angle), Tapers any type (straight, bend, increasing , decreasing or double socket etc), Tee pieces angle branch, cross (all sockets or socket & spigot collars, caps and plugs for joining up to 150 mm bore CI pipe complete all as specified and directed.
Material and labour for dismantling of defective sluice valve of 80mm dia for repairs, including repairs such as repacking stuffing box of sluice valve spindle, refacing, grinding, stuffing and threading of spindle, replacement of worn out check nut, repairs to gate assembly etc, replacement of jointing materials such as rubber sheets, nuts, bolts & washers, gland rope etc and refixing in its original position, testing etc and refixing in its original position, testing etc complete all as specified and directed.
All as per item No. 54 above but 100mm dia bore pipes.
All as per item No. 54 above but 150mm dia bore pipes.
All as per item No. 54 above but 200mm dia bore pipes.
Shree Ram Enterprises
Manak landmarks
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .