Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹56.1 LAccepted-AOC 306 SHIV BARI MARG PANCHVATI NAGAR BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | ₹56.1 L | L1 | Accepted-AOC L1 |
| 2 | L2₹56.5 L+₹31,948.09 (0.57%)Rejected-AOC | ₹56.5 L+₹31,948.09 (0.57%) | L2 | Rejected-AOC L2 |
| 3 | L3₹59.1 L+₹2.9 L (5.23%)Rejected-AOC | ₹59.1 L+₹2.9 L (5.23%) | L3 | Rejected-AOC L3 |
| 4 | L4₹62.7 L+₹6.6 L (11.7%)Rejected-AOC H NO 17036 9 STREET NO 5 A AGGARWAL COLONY BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | ₹62.7 L+₹6.6 L (11.7%) | L4 | Rejected-AOC L4 |
| 5 | L5₹62.8 L+₹6.6 L (11.8%)Rejected-AOC 18969 A 1 SHRI GURU TEG BAHADUR NAGAR BIBIWALA ROAD STREET NO 15 BATHINDA 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | ₹62.8 L+₹6.6 L (11.8%) | L5 | Rejected-AOC L5 |
Tender Value
₹80 L
EMD Value
₹1.4 L
Closing Date
22 Jun 2020, 6:00 pmClosed
CWE (AF) BHISIANA
HQ CWE(AF) BHISIANA
PROVN OF SECONDARY BARBED WIRE FENCING ALONGWITH PERIMETER WALL AND ENERGY SAVING SECURITY LED LIGHTS AT FEROZEPUR UNDER GE(AF) BHISIANA
2020_MES_345901_1
CWE(BHI)/BHI-05/2020-21
Open Tender
Civil Works
Item Rate
270 days
GE AF BHISIANA
Please ref Tender documents
7 documents required · 7 mandatory
₹1,000
Yes
GE (AF) BHISIANA
₹1.4 L
Yes
30 Jun 2020
19 May 2020
24 Jun 2020
19 May 2020
22 Jun 2020
10 Jun 2020
20 May 2020 - 26 May 2020
Amount
Excavation in post holes each n exc 0.6 cum getting out returning filling in and removing earth or broken rubble mixed with earth around in layers not exc 25 cm watering and removing surplus soil to a distance not exc 50m and making good surface as in soft /loose soil and complete all as specified.
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out soft /loose soil and complete all as specified.
M & L cement concrete in foundation filling and mass concrete type C-2 1:3:6 (40 mm graded stone aggregate) and complete all as specified.
Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point and complete all as specified.
75 mm thick cement concrete 1:3:6 type C2 as in floors over and including 75mm thick cement concrete 1:4:8 type D2 in subbase and complete all as specified.
Forming construction (Dummy) joints 65 mm deep and 10 mm wide, filled with grade 'A' sealing compound and complete all as specified.
Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165( Angle post size ISA 75 x 75 x 6 mm thick) and complete all as specified.
Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. and complete all as specified (each line wire to be measured)
S&F Galvanised punched tape concertina coil laying over swan neck fencing post ( Y neck post)(coil dia 610 mm in closed position and 50 turns per coil) complete having galvanised spring steel core with wire of 2.60mm dia, cold drawn, steel galvanised punched tape of low carbon steel having series of sharp barbs uniformily punched along its length having pitch 35+ 1mm and barb length 24+1 mm,width of barb 13 mm and 0.5 mm thickness of tape0.50mm , crimped on steel spring core with galvanised wire clips, GI steel wire handles hooked to coil for handling MS square bars, spike hooked with coil having pointed face for anchorage coil including spreading of each coil 6 to 8 mtr length adequately tied to GI barbared wire fencing with GI wire of not less than 16 gauge at every 500mm spacing tying of handles of succeding coil with preceding coil with GI wire not less than 16 Gauge and complete all as specified.
preparation of new steel surfaces and applying 2 coats of synthetic enamel paint over a coat of red oxide zinc chrome primer primer and complete all as specified..
Excavation in trenches not exc. 1.5 m wide and not exceeding 1.5m depth for foundation of poles/laying of cables/stay/strut etc not exceeding 10 Sq m on plan and getting out in soft/loose soil and complete all as specified..
Returning, filling including spreading, leveling watering and well ramming in layers not exceeding 25 cm and complete all as specified.
Supply, spreading & gently punning fine, dry, clean river sand for cable cushioning all as specified and directed.
M&L for brick protection cover of UG cable by old size bricks common burnt clay building bricks sub class `B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent brick not exceeding 10mm complete all as specified and directed
Make bore to road width for providing GI pipe medium grade both end socketed for passing armoured cable complete all as specified.
M&L for 50 MM bore galvanized steel tubing light garde (ISI marked) protection of cable fixed to pole/walls or laid in floors, road crossing ducts with all necessary fittings and fittings and fixed with clamps, bolts, nuts and washers etc complete all as specified and directed.
M&L cement concrete 1:3:6 type C1 using 20mm graded stone aggregate for foundation of pole/stay/strut etc complete all as specified.
M & L cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for pole pedestal (PCC) including necessary form work etc complete all as specified.
Supply, laying, jointing and testing LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade,heavy duty with aluminium conductor 25 Sqmm 4 core laid in ducts/through pipes, in floor, on poles, in trenches complete all as specified.
Supply, laying, jointing and testing LT cable XLPE insulated, armoured and PVC bedded 1100 volts grade,heavy duty with aluminium conductor 50 Sqmm 3.5 core laid in ducts/through pipes, in floor, on poles, in trenches complete all as specified.
Supplying and fixing 1100 Volts grade heavy duty cable PVC insulated aluminium conductor , served with inner sheathing of PVC Tape and overall PVC sheathed flat or circular of size 4 Sqmm 2 core complete all as specified and directed.
Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) with pole painting upto 1.20 mtr in black and yellow of 30 cm strips and Pole Number alloted complete with CI base plate and finial and single swan neck and all as complete.
Supply and fix 90 watt LED based street light luminaries new generation energy saving & environment friendly light fitting high power LEDs as light sources.LED luminous efficiency should be > 80Lm/w.It should have active power factor correction (APFC) electronic gear (electronic driver).Luminaire housing shall be of pressure die-cast aluminium alloy LM24 for gear and extruded aluminium lamp housing (Heat shrink for better heat transmission.It shall have epoxy powder coated grey finish phosphochromate treatment,IP-66 protection class I operating voltage range should be fron 120 volt to 270 volt AC and frequency range 50Hz.fitting should be suitable for an ambient temperature from -40°C to 50 °C and humidity level 10% to 90% including connection with PVC unsheathed wire aluminium conductor 3 x 1.5 sqmm with cable on pole to light and complete all as specified. . Note:- cost of GI bracket of suitable size and clamps with fixing accessories are to be included on quoted cost.
Supply, installing, testing and commissioning factory made street light junction box Outdoor type platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system all as specified and directed having bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 mm CRCA MS sheet with front opening type with double door shutter and locking arrangement (including provn of lock with 2 keys), powder coated finish (over a coat of red oxide), primer on outside and two coats of red oxide primer on inside surface with TPN aluminium bus bar of rating not less than 200 Amps including 1 No MCB SPN 06 Amps on suitable foundation and complete all as specified.
Supply and fix timer switch switches three phase of 40 Amp rating with contactor, MCB fitted inside steel enclosure complete all as specified and directed.Note:- Fixing of panel on wall/pole to be included in quoted cost
Supply, installing, testing and commissioning factory made LT feeder pillar box outdoor type platform mounted, suitable for 415 volts 3.5 phase 4 wire, 50 Hz AC supply system all as specified and directed having bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 mm CRCA MS sheet with front and rear opening type with double door shutter and locking arrangement (including provn of lock with 2 keys), powder coated finish (over a coat of red oxide), primer on outside and two coats of red oxide primer on inside surface. The panel is including platform with PCC 1:4:8 type D-2 with 40mm crushed stone aggregate 20cm in thick in foundation and of height upto 0.5 mtr all as directed at site . All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN copper bus bar of rating not less than 200 Amp and should be insulated with shrinkable PVC sleeves. The MCCB should be adjustable type. The scope of work includes provision of following Note: All MCCBs should have adjustable thermal and magnetic settings (i) ON Load change over switch upto 63 Amp-01 Nos (ii) MCCB 4 pole 40 amps 16 kA - 01 Nos (incoming) (iii) MCCB 4 Pole 25 Amp 16 kA - 01 Nos (out going) (iv) MCCB 4 Pole 25 Amp 16 kA - 01 Nos (spare) (v ) Digital Voltmeter & Ammeter with necessary CT's and wirinng.Make : AE/Conserve/Rishabh (vi) Phase indiacting lamps (R-Y-B) - 01 set. NOTE -drawing shall be approved by GE
Earthing complete with galvanised steel earth plate electrode 600 × 600× 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised strip 32 x 6mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thic in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,40 mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed
M&L in repair earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected to and including galvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earthing test point and earth dolly all as shown in electrical plate No 3 of MES SSR part I and testing on completion including necessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thick in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,15mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc all as specified and as directed.
Supply & install outdoor LT Bus Bar Chamber 4 way box double door with phase indicating lam p3.15 mm thick CRCA Sheet weather and vermin proof CPRI approved with Aluminium bus bar not less than 200 Amps suitable for LT cable 11KV, 4 core of size upto 120 sqmm including provision of cable entries with glands locking arrangements and angle iron frame and legs of 90 cm long using 60x60x6 mm size MS angle iron fixed in floor in PCC 1:4:8 type D2 base of appropriate size including neccessary excavation earth work including fencing with lockable gate complete all as specified.
Aman Enterprises
AABIA CONSTRUCTION
M/s MITTAL CONSTRUCTIONS
SHARDA ENTERPRIES
Marwaha Builders
M/S SURINDER KUMAR MAHAJAN
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .