Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAccepted-AOC 53 13 A OUTER CIRCULAR ROAD KILPAUK GARDEN COLONY CHENNAI 600 010 | CHENNAI | CHENNAI | TAMIL NADU | 600010 | L1 | Accepted-AOC Being the lowest tenderer | |
| 2 | L2₹27.8 L+₹5.6 L (25.1%)Rejected-Finance NO 42 SIVAN STREET SRI VENKATESAPERUMAL NAGAR VALASARAVAKKAM CHENNAI 600087 | CHENNAI | CHENNAI | TAMIL NADU | 600087 | L2 | Rejected-Finance Not being the lowest tenderer |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
8 Nov 2021, 6:00 pmClosed
GE Chennai
Garrison Engineer Fort Saint George Chennai - 600009
REPAIRS TO FINS FASCIAS CHAJJAS GI PIPE LINE RAIN WATER PIPE LINE SWR PIPE LINE AND WATER TANKS WITH CONNECTED ITEMS IN ZONE B and E AREA UNDER GE CHENNAI
2021_MES_478170_1
8553/E8
Open Tender
Civil Works
Item Rate
183 days
Fort Saint George
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE Chennai
₹50,000
Yes
24 Nov 2021
27 Sept 2021
13 Nov 2021
27 Sept 2021
8 Nov 2021
11 Oct 2021
Amount
BOQ UPLOADED ON 27 SEP 2021
Supply only PIDI PROOF LW liquid water proofing compound conforming to IS: 2645-2003 all as specified and directed.
M&L for reinforced cement concrete, M-30 (Design mix), using 20mm and below graded stone aggregate as in roof beams, cantilevers, bressummers, lintels over 1.5m span all as specified and directed.
M&L for reinforced cement concrete, M-30 (Design mix), using 20mm and below graded stone aggregate as in chajjas etc. complete all as specified and directed.
M&L for reinforced cement concrete, M-30 (Design mix), using 20mm and below graded stone aggregate as in fins, fascias, louvers, parapets, railing exc. 60cm in height, newels, balustrade and the like complete all as specified and directed.
M&L for cement concrete (1:1½:3) type A-1 using 20mm graded aggregate as in water tank base slab including necessary formwork complete all as specified and directed.
M&L for brick work straight or curved on plan exceeding 6 metre mean radius using old size fly ash bricks built in cement mortar (1:6) all as specified and directed.
Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, including supports, overhangs, etc. also splays between floors and beams complete of flat for rough finished surfaces of concrete all as specified and directed.
Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exc. 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc. 10cm but not exc. 20cm wide flat for rough finished surfaces of concrete all as specified and directed.
Use and waste of formwork to chullah hoods, chajjas, troughs and similar items including edges of flat for rough finished surfaces of concrete all as specified and directed.
Use and waste of formwork to fins, louvers, fascias, and similar items for rough finished surfaces of concrete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Taking down cement plaster on brick work or stone walls etc. including racking out of joint, hacking for key, scrubbing down with water etc. and removing the debris outside MD land complete all as specified and directed.
M&L rendering 15mm thick in cement mortar (1:4) on fair faces of brick/ concrete surface mixed with water proofing compound and surface finished even and smooth without using extra cement complete all as specified and directed. Note: Supply only of water proofing compound shall be measured and paid for separately.
M&L for preparation of new surface and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/ litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm complete all as specified and directed.
M&L for preparation of old treated surface of walls and applying two coats of weather proof exterior acrylic emulsion paint (Apex Ultima of Asian or equivalent of other specified makes) of shade as approved complete all as specified and directed.
S&F galvanised steel water tubing 15mm bore medium grade including provision of all pipe fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc. fixed to walls, concealed in walls/ ceilings or laid in floors etc. including taking up or down the existing GI tubing complete all as specified and directed.
All as per item No. 16.00 above but 20mm bore.
All as per item No. 16.00 above but 25mm bore.
Taking up or down the existing GI water tubing 15mm bore medium grade and re-fixing in same or other location using new fittings such as bends, tees, elbows, reducers, unions, plugs, sockets etc. fixed to walls, concealed in walls/ ceilings or laid in floors etc. complete all as specified and directed.
All as per item No. 19.00 above but 20mm bore.
All as per item No. 19.00 above but 25mm bore.
S&F 500 ltr capacity three layered rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position including dismantling existing OHT complete all as specified and directed.
S&F 1000 ltr capacity three layered rotational moulded polyethylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position including dismantling existing OHT complete all as specified and directed.
Disconnecting existing overhead tanks of capacity exceeding 250 litres and not exceeding 500 litres, setting aside (or lowering if required) for repairs and cleaning, removing all scale and dirt etc., from tanks and from mouths of circulating pipes etc. and hoisting, reconnecting and re-fixing in position including writing date of cleaning & due date of cleaning complete all as specified and directed.
Disconnecting existing overhead tanks of capacity exceeding 500 litres and not exceeding 1000 litres, setting aside (or lowering if required) for repairs and cleaning, removing all scale and dirt etc., from tanks and from mouths of circulating pipes etc. and hoisting, reconnecting and re-fixing in position including writing date of cleaning & due date of cleaning complete all as specified and directed.
S&F gun metal, globe or gate valve confirming to IS 778-1984 with iron wheel head, screwed both ends for 20mm bore iron pipe and fixed in repairs complete all as specified and directed.
S&F gun metal, globe or gate valve confirming to IS 778-1984 with iron wheel head, screwed both ends for 25mm bore iron pipe and fixed in repairs complete all as specified and directed.
S&F in repairs ball brass valve for 20mm bore pipe high pressure with polyethylene high density float and fly nut complete screwed for iron pipe complete all as specified and directed.
S&F in repairs cover for rotational moulded polyethylene water storage tank of any capacity with locking arrangement and fixed in position complete all as specified and directed.
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall etc. including demolition and breaking up existing pipe complete all as specified and directed.
S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall etc. including demolition and breaking up existing pipe complete all as specified and directed.
S&F in repairs 32mm bore unplasticised PVC pipes of pressure rating 10 kgf/cm² fixed complete to walls, ceilings or in floors etc. including all pipe fittings such as ends, elbows, unions, tees, reducing tees, adaptors, sockets, plugs, hose clips etc. complete all as specified and directed.
S&F PVC (SWR) bend any radius with access door suitable for 110mm dia pipes complete all as specified and directed.
S&F PVC (SWR) bend any radius suitable for 110mm dia pipes complete all as specified and directed.
S&F PVC (SWR) bend any radius with access door suitable for 75mm dia pipes complete all as specified and directed.
S&F PVC (SWR) bend any radius suitable for 75mm dia pipes complete all as specified and directed.
S&F in repairs PVC (SWR) branch piece single (single 'Y') equal or unequal 110mm bore with access door complete all as specified and directed.
S&F in repairs PVC (SWR) branch piece single (single 'Y') equal or unequal 75mm bore with access door complete all as specified and directed.
S&F PVC (SWR) junction single (single 'T') equal or unequal 110mm bore with access door complete all as specified and directed.
S&F PVC (SWR) junction single (single 'T') equal or unequal 75mm bore with access door complete all as specified and directed.
S&F in repairs 110mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F in repairs 75mm bore PVC (SWR) vent cowl complete all as specified and directed.
M&L chipping off loose concrete, broken plastering in chajjas, ceiling, fins and fascia carefully and applying one coat of DR FIXIT rust remover and then one coat of DR FIXIT PIDICRETE concrete MPB bonding agent and 20mm thick rendering in cement mortar (1:4) in two coats of 10mm thick each coat complete all as specified and directed.
Demolition of brick masonry built in cement mortar including all quoins/ arches/ pillars etc. but excluding ashlars facings, dressed stone work, precast concrete articles and disposing off the rubbish outside MD land complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any situation not otherwise specifically provided for complete all as specified and directed.
SWIFTTECH ENGINEERS INDIA PVT LIMITED
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .