Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 CrAccepted-AOC | ₹9.7 Cr | L1 | Accepted-AOC Low Rate |
| 2 | L2₹10.0 CrRejected-Finance | ₹10.0 Cr | L2 | Rejected-Finance High Rate |
Tender Value
₹11.6 Cr
EMD Value
₹21.6 L
Closing Date
17 Nov 2022, 12:00 pmClosed
SE Kanpur Circle PWD Kanpur
SE Kanpur Circle PWD Kanpur
Construction of Residential /Non-residential building of Fire Station at Bithoor Constituency in District Kanpur Nagar
2022_CEKNP_747435_1
5576C/131C-KV/2022-23 Dt. 11.10.2022
Open Tender
Civil Works - Buildings
540 days
Kanpur Nagar
Please refer tender Documents
3 documents required · 3 mandatory
₹6,260
₹21.6 L
Yes
SE Kanpur Circle PWD Kanpur
12 Dec 2022
11 Nov 2022
17 Nov 2022
11 Nov 2022
17 Nov 2022
11 Nov 2022
14 Nov 2022
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the (All kinds of soil.) 0.00 to 1.50m
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. (All kinds of soil) 1.50m to 3.00m
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. (All kinds of soil) 3.00m to 3.65m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 1km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. (Add Extra on Item No. 2.25 (a) above for 5 Km. Carted earth)
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm (nominal size)
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but including the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). All works Upto plinth Level
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but including the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/recoverable separately). All works above plinth & upto Terrace
Centering and shuttering including strutting, propping etc. and removal of form for : Lintels, beams, plinth beams, girders, bressumers and cantilevers
Centering and shuttering including strutting, propping etc. and removal of form work for (Upto 5th Floor) : Foundations, footings, bases for columns
Centering and shuttering including strutting, propping etc. and removal of form work for (Upto 5th Floor) : Columns, piers, abutments, pillars, posts and struts
Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick
Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick
Centering and shuttering including strutting, propping etc. and removal of form work for (Upto 5th Floor) : Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
Providing and laying in position ready mixed M-30 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. Upto plinth Level.
Providing and laying in position ready mixed M-30 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. Above plinth Level.
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Brick work with common burnt clay (non modular) bricks of class-150 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay (non modular) bricks of class -150 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry with common burnt clay (non modular) bricks of class -150 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1 cement :3 coarse sand)
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil.
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece
Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge.
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary
Add Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 250x16 mm
Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 250x10 mm
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 125 mm
Mild Steel Iron Grill & Staircase railing of a approved qualitiy and drawing including supply of all materials, fabrication, labour, T&P in all respect as per direction of Engineer-in-charge for proper completion of work at site.
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65mm.
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand)
Extra for Plastering exterior walls of height more than 10 mtr from ground level for every additional 3m height.(Scaffolding and sundries) (10 to 13 M)
Extra for Plastering exterior walls of height more than 10 mtr from ground level for every additional 3m height.(Scaffolding and sundries) (13 to 16 M)
12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
Making grooves 10 to 12mm wide x 8mm deep in plaster of the wall or in ceiling vertically or horizontally as required.
Making drip course in sunshade or FACIA as per direction as Engineer-In-Charge including supply of all material, labour etc. required for proper completion of work.
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate
Providing and fixing 18 mm thick Granite (gang saw cut), mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. (Slab area upto 0.50 Sq.M.)
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
Finishing walls with Putty approved brand and manufacture and of required shade on undacorated wall surface to give even shade over including curing and cost of all material, labour, T&P etc. required for proper completion of work.
Distempering (first coat) with oil bound distemper of approved brand and manufacture and of required shade on undercoated wall surface to give an even shade over & including a priming coat with cement primer of approved brand and manufacture such as Berger, J&N, Shalimar, Asian, paints after thoroughly brushing the surface free from mortar droppings and other foreign matter and also including preparing the surface even with plaster of approved synthetic material and sand papered smooth including cost of all materials.
Finishing walls with exterior emulsion paint (Apex) of approved brand and manufacture and of required shade on undacorated wall surface to give even shade over @ 1.25 Ltr/10sqm including one coat of primer applid @ 0.75Ltr/10sqm coat curing and cost of all material, labour, T&P etc. required for proper completion of work.for two coat.
Painting 1st coat over priming coat (but excluding cost of priming coat) on steel and other metal surfaces upto 10cm width or girth or small articles not exceeding 0.10 Sq.M. in area with superior synthetic enamel such as Luxol 3, Hi gloss Apcolite, Superlac, Dulux specified brushing to give and even shade and including the cleaning the surface of all dirt, dust and other foreign matter sand papering and scrapping including cost of all materials, labour, tools and plants etc. required for proper completion of work.
Applying priming coat over new steel and other metal surface upto 10cm. In width or girth or small not exceeding 0.10 Sq.M. area after and including preparing the surface by thoroughly clearing oil, grease, dirt and other foreign matter and scoured with wire brushed, fine steel/wood. Scrapper, sand papering and knotting including cost of all materials, labour T&P etc. required for proper completion of work. (a) Same as in item 1 above but on new wood surfaces.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
P/L 25mm OB brick Ballast under floor of toilet sunken roofs
Add for using extra cement in th Items of Design Mix over and above the specified Cement Content In M-25 Concrete 400Kg/cum cement instead of 330 Kg/cum
Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, upto 25 metre height, above ground level, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works
Providing and fixing Indian type glazed earthen ware W.C. pan of approved quality size 580mm Orisa pan with 100 mm Sand Cast Iron P or S trap,P.V.C. Flush pipe including supply of all materials, labour and T&P etc for the proper completion of the work including removal of old pan etc. if so required.
Supply and fixing of P.V.C low level cistern 10 litre capacity with all internal fittings P.V.C. Connection 450 mm long, C.P. angle valve 15mm dia, brass ball cock complete including suplly of all material, labour, T&P etc. required for proper completion of the work.
Supply and fixing of White Glazed earthen ware wash hand basin (Jaquar ESSCO, cera,hindware) with C.P. jali, angle valve (L&k,Jaquar ESSCO or equiv.), PVC waste pipe,pillar cock (L&k,Jaquar ESSCO or equiv.),bracket, pvc connection pipe 15mm dia 450mm long etc complete including supply of all materials,Labours,T&P etc.required for proper completion of the work (22"X16"size)
Providing and fixing white vitreous china flat back or wall corner type Flat back or angular front lipper urinal basin of white glazed earthen ware 580x380x350 mm (Jaquar ESSCO, cera,hindware) with CP angle valve, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required: Single half stall urinal with 5 litre PVC. automatic flushing cistern
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 225 mm
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete
Providing and fixing of glass shelf thick 600x120x5 mm size with C.P. Guard standard size and bracket including supply of all material labour T&P required for proper completion of the work
Providing and fixing soil, waste and vent pipes : 100 mm dia Sand cast iron S&S pipe as per IS: 1729 required for proper completion of the work.
Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including cost of cutting holes and making good the walls etc (100mm dia)
Providing and fixing HCI heel rest sanitary bend 100 mm dia Sand cast iron S&S as per IS - 1729
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100 mm dia Sand cast iron S&S as per IS - 1729 (HEP Make)
Providing and fixing terminal guard. 100 mm. Sand cast iron S&S as per IS - 1729. HEP MAKE
Providing and fixing collar 100 mm. Sand cast iron S&S as per IS - 1729. HEP MAKE
Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter. 100 mm.
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: 100 mm inlet and 100 mm outlet Sand cast iron S&S as per IS: 3989
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture
Providing and fixing PTMT. Soap dish, Jaquar ESSCO, cera,hindware with concealed fitting including supply of all material , labour T&P etc. complete.
Providing and fixing PTMT towel rail 750x20mm together with pair of CP brass brackets to fit the towel rail complete
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall, 20mmdia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 25mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 32mmdia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 40mmdia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 50mmdianominal bore
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : : 15 mm dia nominal bore
Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall : 20 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 40mmdia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 50mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 65mmdia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 80mmdia nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25mm dia nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32mmdia nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40mmdia nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 50mmdianominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 65mmdia nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 80mmdia nominal bore
Providing and fixing C.P. brass shower heavy quality (Jaquar ESSCO,cera,Hindware) with Over Head brass Shower Arm 240 mm long with wall flange (Jaquar ESSCO,cera, Hindware) 15mm inlet:100 mm diameter
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : 20mmdia nominal bore
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : 25mm dia nominal bore
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : 32mmdia nominal bore
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : 40mmdia nominal bore
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work : 50mmdianominal bore
Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 40mmdia nominal bore
Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 50mm dia nominal bore
Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 65mmdia nominal bore
Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 80mmdia nominal bore
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 40mmdia nominal bore
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 50mm dia nominal bore
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 65mmdia nominal bore
Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 80mmdia nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 15mm dia nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 20mmdia nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 25mm dia nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 32mmdia nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 40mmdia nominal bore
Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 50mmdianominal bore
Supply and Fixing C.P. brass bib cock heavy quality short body of 15mm. dia.(L&K,Jaquar Essco)
Providing and fixing C.P. brass long body bib cock of (L&K,jaquar essco) conforming to IS standards 15 mm nominal bore
Providing and fixing C.P Angle valve 15mm dia (L&k,Jaquar ESSCO or equiv.) for geyser points of approved quality 15 mm nominal bore.
Providing and fixing CP Jalli heavy quality. Circular type - 100 mm nominal dia
Close timbering in trenches including strutting, shoring and packing cavities (wherever required) complete (Measurements to be taken of the face area timbered). (Depth not exceeding 1.5 m.)
Laying cement concrete 1:5:10 in haunching S.W. pipes including concrete for bedding necessary form work and curing complete. 150 mm diameter R.C.C pipes
Laying cement concrete 1:5:10 in haunching S.W. pipes including concrete for bedding necessary form work and curing complete. 200 mm diameter R.C.C pipes
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 150 mm diameter R.C.C pipes
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 250 mm diameter R.C.C pipes
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Fisnihed with a floating coat of neat cement complete as per standard design : (a) Inside size 900 x 800mm and 500mm deep including C.I. Cover frame.
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Fisnihed with a floating coat of neat cement complete as per standard design : (b) Inside size 1200 x 1200mm and 1.0meter deep including C.I. Cover frame.
Extra over Item No. 24.27 for every additional depth of 0.10 metre or part there of main hole. (a) Size 900 x 800 mm
Extra over Item No. 24.27 for every additional depth of 0.10 metre or part there of main hole. (b) Size 1200 x 900mm
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter.
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC and compacting with smooth wheel roller to achieve the desired density, complete as per technical specification clause 401
Providing, laying, spreading and compacting (7.5 cm compacted thickness) stone aggregates of 22.4-53 mm sizes to water bound macadam (WBM-3) specification including spreading of in uniform thickness hand packing, rolling with smooth wheeled roller 8-10 kN in stages to proper grade and camber, applying and brooming, stone screening (Type-B)/ binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading-3 as per Technical Specification clause 405.
Construction of un-reinforced, dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days,
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer- in-charge).
15 mm cement plaster on rough side of single or half brick wall of mix: 1:4 (1 cement: 4 coarse sand)
Providing and laying cement concrete in retaining walls, return walls, walls (anythickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:1½:3 (1 cement : 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm (nominal size).
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. (400 mm Dia)
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. (400 mm Dia)
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. (200 mm Dia)
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with.ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. (200 mm Dia)
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:.200 mm cap
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge.
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.200 mm clamp .
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. of: 100 mm Dia .
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). of: 200 mm Dia
Nylon mesh for filter.
Plastic Rope.
Solvent Cement.
3'' G.I. Elbow.
3'' X 6'' G.I. Nipple.
7.5 HP 9 Stage submersible pump of ISI mark with automatic panel.
4 sqm submersible cable.
2'' MS socket.
Supportng wire with plastic coated.
Finishing walls with water proofing cement paint of approved make such as Super snowcem, Durocem, Robiance, Guttucem, Supercem quality and of required shade on under coated wall surface (Two coat) over and including one coat white cement primer to give and even shade after thoroughly after brushing the surface .
Disinfecting C.I. water mains by flushing with water containing bleaching powder @ 0.5 gms per litre of water and cleaning the same with fresh water, operation to be repeated three times including getting the sample of water from the disinfected main tested in the municipal laboratory. 80 mm diameter C.I. pipe
Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : 100 mm diameter Class II
Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg
Supplying, filling, spreading & leveling stone boulders of size 45-90 range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge
supply of Stainless steel Jali wire guage (Grade-304) aperture 1.4 mm and 0.50 mm dia wire
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level.
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 100 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with.ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I)..100 mm dia .
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.110 mm diameter.
Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit concealed in wall with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit GP Box , Modular type switch & ceiling rose/ angle/batten holder on 3 mm thick phenolic laminated backelite sheet etc., complete in all respect.
Wiring point for two way light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit concealed in wall with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit GP Box , Modular type switch & ceiling rose/ angle/batten holder on 3 mm thick phenolic laminated backelite sheet etc., complete in all respect.
Wiring point for plug/Computer/TV/Aquqgaurd with 1.5 sqmm FRLSH P.V.C. insulated multistrand single core copper conductor cable in P.V.C. conduit concealed in wall with one no. 1.5 sq MM FRLSH PVC insulated multistraine cu. conducter cable as earth Wire drawn inside the conduit with modular type switch & socket etc. complete in all respect as directed including matching colour wash.
Wiring point for fan/fresh air fan with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit concealed in wall with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit GP Box , modular type switch & ceiling rose/ angle/batten holder on 3 mm thick phenolic laminated backelite sheet etc., complete in all respect.
Wiring point for exhaust fan with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit concealed in wall with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit GP Box , 15Amp. modular type switch & ceiling rose/ angle/batten holder on 3 mm thick phenolic laminated backelite sheet etc., complete in all respect.
Wiring point for call bell with 1.5 sqmm FRLSH P.V.C. insulated multistrand single core copper conductor cable in P.V.C. conduit concealed in wall with one no. 1.5 sq MM FRLSH PVC insulated multistraine cu. conducter cable as earth Wire drawn inside the conduit with modular type bell push or 2 pin socket etc. complete in all respect.
Wiring point for H.P.M.V./ Sodium Vapour lamp with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit concealed in wall with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit GP Box , 15Amp. modular type switch & ceiling rose/ angle/batten holder on 3 mm thick phenolic laminated backelite sheet etc., complete in all respect.
Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit concealed in wall with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit GP Box , piano type switch & ceiling rose/ angle/batten holder on 3 mm thick phenolic laminated backelite sheet etc., complete in all respect.
Wiring point for two way light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit concealed in wall with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit GP Box , piano type switch & ceiling rose/ angle/batten holder on 3 mm thick phenolic laminated backelite sheet etc., complete in all respect.
Wiring point for fan/fresh air fan with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit concealed in wall with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit GP Box , piano type switch & ceiling rose/ angle/batten holder on 3 mm thick phenolic laminated backelite sheet etc., complete in all respect.
Wiring point for plug/Computer/TV/Aquqgaurd with 1.5 sqmm FRLSH P.V.C. insulated multistrand single core copper conductor cable in P.V.C. conduit concealed in wall with one no. 1.5 sq MM FRLSH PVC insulated multistraine cu. conducter cable as earth Wire drawn inside the conduit with piano type switch & socket etc. complete in all respect as directed including matching colour wash.
Wiring point for call bell with 1.5 sqmm FRLSH P.V.C. insulated multistrand single core copper conductor cable in P.V.C. conduit concealed in wall with one no. 1.5 sq MM FRLSH PVC insulated multistraine cu. conducter cable as earth Wire drawn inside the conduit with piano type bell push or 2 pin socket etc. complete in all respect.
Wiring point for exhaust fan with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit concealed in wall with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit GP Box , 15Amp. piano type switch & ceiling rose/ angle/batten holder on 3 mm thick phenolic laminated backelite sheet etc., complete in all respect.
Add for inverter wiring point light/fan /plug with 1.5 sq mm cu wire.
Supply & Fixing of power plug with 20Amp./ 250 V flush type modular socket switch on concealed MS box including supply of all material, labour T&P etc. Required for proper completion of work complete in all respect.
Supply and fixing of power plug with 15A/250 volt flush type switch and 5 pin 15A/250V flush type universal socket in suitable M.S. box of 175mm x 100mm x 50mm size with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer.
Supply and fixing of electronic fan regulator 120-280 V. ISI marked, on the existing switch board including making connections, required material, labour T&P etc. for proper completion of work to the satisfaction of Engineer in charge of work.
S&F of Sheet enclosure surface/flush mounting fitted with 30 amp 2 pin and metal clad scrapping earth plug and socket complete in all respect
Supply and fixing sheet steel enclosure surface/Flush mounting fitted with 20Amp. 2Pin and earth metal clad scraping earth plug and socket complete in all respect. as directed at site by Engineer in charge.
S/f of LED tube light with metal body heavy duty box type batten light fitting 1x22 watt. suitable for up to 22 watt LED polycarbonate tube light complete suitable for both surface & suspended complete in all respect. 2200 system lumens, 110Im/W, PF>0.95, THD<10% CRI>80, Tube with aluminium heat .
S/F of call bell of app. Make complete.
Supply and fixing of LED street light fitting with mandatory driver set having die cast aluminium body and lenses suitable for 75watt to 90 watt, confirming to IP 66 protection having company LOGO engraved complete in all respect including labour. CAT-AA 7500-9000 system lumens, Mid Power LED with lenses, 100 Im/W, PF>0.95, THD<10% at full load CRI>70, driver set (Not Circuitory) .
Supply and fixing of LED street light fitting with mandatory driver set having die cast Al. body and lenses suitable for 45 watt to 50 watt. Confirming to IP 65/66 protection having company logo engraved complete in all respect including labour. 4500-5000 system lumens, mid power LED with lenses, 100lm/W, P.F>0.95, THD<10%, at full load, CRI>70, driver set(not circuitory).
Supply and fixing of water tight oblong 10 Watt LED bulkhead luminaire with driver set confirming to IP 65 and above Protection . complete in all respect. CAT-AA 1000 system lumens, 100 Im/W, PF>0.95,.
Supply and fixing of single light wall bracket 3 to 6 Watt on matching M.D.F.E.G. Board base etc. complete in all respect. Cat-AAA 330-660 System lumens, 110Lm/W, P.F.>.95.
Supply & Installation of split Direct Expansion air-conditioner with D.C. Inverter Technology suitable for operation on A/C supply single phase 50 Hz 230 Volts with hermetically scaled compressor with air cooled condensor with , motor capicitor and start run capacitor, relay and over load protector internal unit, will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube. (High wall chorded/cordless) suitable capacity 3 core sheathed /PVC copper cable and a battery operated wireless remote unit.
S/F of Copper pipe @ 5 mtrs. Per A.C.
S/F of power lead from inner to outer unit of A.C. @ 5 mtr. Per A.C.
S/F of drain pipe 1.25" @ 20 mtrs. Per A.C. Including TEE, Elbow , Clamp etc.
S/F of MS stand for outdoor unit of Split AC.
S/Fof Wall mounting Voltage Stablizer Suitable for upto 2T capacity AC (Range 130-280 Volt) (V Guard, Microtek, Luminous)
Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130 mm and base plate 12mm thik) having 3mm thikness with Double arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect.
S&F of 32 Amp. 240 V DP metal clad rewireable type switch fuse unit on M.D.F.E.G. / Teak wood board complete in all respect.
Erection and testing of ceiling fan and regulator etc. exculding supply oa down rod, complete in all respect.
Supply of ceiling fans with fan motor of A.C. permanent insulation, capacitor rating conforming BEE 5 star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment. The rated voltage 220/240 volts, 50 Hz, 1-Ph AC the fan assemble should consists of down rod blades, shackle canopies etc and with double ball bearing system. BEE 5 Star rated-1200 mm sweep.
Erection and testing of Fesh air/exhaust fan on existing hole with suitable size of rag bolts, nuts and washers etc. complete.
Supply and fixing of 16 SWG M.S. drum with luvers duly painted including making hole in the wall for exhaust fan and finishing properly complete in all respect.
Making hole in the wall for exhaust fan and finishing properly complete in all respect.
Supply and fixing of electronic fan regulater (modular) 120-280V ISI marked on the existing switch bourd including making connection complete in all respect.
S/W of 2 number 2.5 sq mm P.V.C. insulated 1100 v grade FRLSH multistrand single core copper conductor cable in 20 mm dia heavy (2 mm thick) P.V.C. conductor with no. 1.5 sq. mm FRLSH PVC insulated copper conductor cable as earth continuity wire including matching colour wash etc. complete in all respect.
S/W of 2 number 4 sq mm P.V.C. insulated 1100 v grade FRLSH multistrand single core copper conductor cable in 20 mm dia heavy (2 mm thick) P.V.C. conductor with no. 2.5 sq. mm FRLSH PVC insulated copper conductor cable as earth continuity wire including matching colour wash etc. complete in all respect.
S/W of submain 2 number 6 sq mm FRLSH P.V.C. insulated 1100 v grade multistrand single core copper conductor cable in 25 mm dia heavy (2 mm thick) P.V.C. conductor with one no. 4 sq. mm FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including matching colour wash etc. complete in all respect.
S/W of submain 2 number 10 sq mm FRLSH P.V.C. insulated 1100 v grade multistrand single core copper conductor cable in 25 mm dia heavy (2 mm thick) P.V.C. conductor with one no. 6 sq. mm FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire including matching colour wash etc. complete in all respect.
S/W of submain 4 number 16 sq mm FRLSH P.V.C. insulated 1100 v grade multistrand single core copper conductor cable in 50 mm dia heavy (2 mm thick) P.V.C. conductor with two no. 16 sq. mm FRLSH PVC insulated copper conductor cable as earth continuity wire including matching colour wash etc. complete in all respect.
Supply and wiring of submain with 4 Nos. 25.0 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 50 mm dia heavy (2mm thick) PVC conduit with 2 number 16.0 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor as earth continuity wire drawn inside the conduit as earth continuity wire etc. including matching colour wash etc. complete in all respect.
S/f of surface/flush mounting 12 Way SPN DB. With additional metal door without MCB complete in all respect.
Supply and fixing surface/flush mounting 8ways SPN distribution board with additional metal door without MCB complete in all respect, as directed by Engineer in charge.
Supply and fixing surface/Flush mounting 4 ways TPN distribution board with additional metal door without MCB complete in all respect, as directed at site by Engineer in charge.
S/f of surface/flush mounting 6 Way TPN DB. With additional metal door without MCB complete in all respect.
S & F surface/Flush mounting 4ways V TPN distribution board with additional metal door without MCB complete in all respect,as directed at site by Engineer in charge.
S/f of 6 Amp. To 32 Amp. SPMCB (10 KA).
S/f of 40 Amp. SPMCB (10 KA).
S/f of 40 Amp. D.P. Isolator.
S/f of 63 Amp. 4 pole Isolator.
Supply and fixing of 100 Amp. 4 pole Isolater.
S&F of 63 Amp 4 pole MCCB (16 KA) Thermal Magnetic release
S&F of 125 Amp 4 pole MCCB (16 KA) Thermal Magnetic release
Supply and fixing single pole MCB blanking plate
Supply and fixing of 63 Amp. 415 V metal clad TPN HRC type switch fuse unit complete with HRC fuse on angle iron bracket complete in all respect.
Supply and fixing of 100 Amp. 415 V metal clad TPN HRC type switch fuse unit complete with HRC fuse on angle iron bracket complete in all respect.
S/Fixing of 63A/415 V kit kat fuse (Anchor or Equivalent) Complete in all respect.
S/Fixing of 100A/415 V kit kat fuse (Anchor or Equivalent) Complete in all respect.
S&F of 400 Amp. 415 V Heavy duty double break HRC fuse type metal clad TPN complete with HRC fuse etc. on angle iron frame complete in all respects.
S&F of 400 Amp. four pole change over switch on 50mm x 50mm x 6mm angle iron frame, including the cost of labour, T&P, painting and other material required for proper completion of the work as per direction and satisfaction of Engineer in charge.
Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Make: As approved in U.P. P.W.D., & C.P.R.I. Certified.
Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified.
Supply and laying of 25mmx3mm GI strip from earth electrode directly in ground as required complete in all respect.
Supply and fixing of 2 Nos. number 8 SWG G.I. Wire in 15mm dia.G.I. pipe for earthing , laid in ground or in wall duly concealed including the cost of cement , sand , labour, T&P other material required for proper completion of the work as directed at site.
Supply and laying of following size aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts gradecet a dopth of 750 mm below ground level cover acushion of 75 mm thick sand alround and protected with bricks on surface the cable run shall be fixed on M.S. clamp etc. of suitable size. the armouring of the cable shall be properly connected with earth conductor by clamps etc complete. (i) 400 Sq. mm 3½ core.
(ii) 50 Sq. mm 3½ core.
(iii) 10 Sq. mm 2 core.
Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed under ground cable including ruber ring etc complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-in-charge. (i) 400 Sq. mm 3½ core.
(ii) 50 Sq. mm 3½ core.
Supply and fixing of plain or in type copper Tin plated cable socket (Lug) to the cable leads, insulatin with tape & making connection etc complete in all respect as per direction of Engineer-in-charge. (i) 400 Sq. mm
(ii) 240 Sq. mm
(iii) 50 Sq. mm
(iv) 25 Sq. mm
Supply and fixing fire extingusher, ABC type 4 kg. capacity (I.S.I Mark IS: 15683 and TAC Approved) complete with initial charge and wall bracket aling with supply of all materials & Labour for copper compilition of work
Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work.
Supply and fixing fire bucket, round botton made of G.I. Sheet 9-11 Ltr. Capacity duley painted as per fire brigade design, supported on hanging braket chained & locked, initiall filled with find river sand, water as per directions of engineer-in-charge.
Supply and Laying of 1800 mm x 900 mm x 12mm. Thick chequred rubber matting of tested quality.
Supply and fixingof shock treatment chart (Prescribed under I. E. rules) duly frame with glass & supported from back with hard board or soft board with supply of all material Labour T & P for copper compression of work.
Supply and fixing of danger board fabricated from 10 gauge M.S. Sheet as per IE rule.
Cost of LED Bulb 10 Watt
Cost of Fresh Air Fan 250 mm. Sweep.
Cost of Exhaust Fan 300 mm. Sweep.
MHPL INDIA PRIVATE LIMITED
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid