| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.0 CrAccepted-AOC | ₹3.0 Cr | 1 | Accepted-AOC Lowest bidder |
| 2 | 2₹3.1 Cr+₹9.5 L (3.18%)Rejected-Finance RAVI KIRAN MARKET JIWAJI CHOWK BADA LASHKAR GWALIOR M P 474001 | GWALIOR | GWALIOR | MADHYA PRADESH | 474001 | ₹3.1 Cr+₹9.5 L (3.18%) | 2 | Rejected-Finance Other than Lowest bidder |
| 3 | 3₹3.2 Cr+₹21.5 L (7.17%)Rejected-Finance | ₹3.2 Cr+₹21.5 L (7.17%) | 3 | Rejected-Finance Other than Lowest bidder |
| 4 | 4₹3.2 Cr+₹24.7 L (8.25%)Rejected-Finance 23 A MORAR ENCLAVE GOLA KA MANDIR MORAR GWALIOR MP 474005 | GWALIOR | GWALIOR | MP | 474005 | ₹3.2 Cr+₹24.7 L (8.25%) | 4 | Rejected-Finance Other than Lowest bidder |
| 5 | 5₹3.3 Cr+₹28.1 L (9.38%)Rejected-Finance | ₹3.3 Cr+₹28.1 L (9.38%) | 5 | Rejected-Finance Other than Lowest bidder |
Tender Value
₹3.1 Cr
EMD Value
₹3.9 L
Closing Date
24 Dec 2021, 6:00 pmClosed
CE AF Allahabad
HQ CE AF Allahabad
ADDN /ALTN TO BLDG NO P-65 AND P-70 AT AF STATION GWALIOR
2021_MES_481821_1
958429/E8
Open Tender
Civil Works
Lump-sum
365 days
GE(AF) ADM Area Gwalior_
As per tender Documents
6 documents required · 6 mandatory
₹2,000
Yes
GE(AF) ADM Area Gwalior
₹3.9 L
Yes
8 Mar 2022
14 Oct 2021
31 Dec 2021
14 Oct 2021
24 Dec 2021
10 Dec 2021
Amount
BUILDING WORKS
Construction of AC PLANT ROOM with permanent specification, complete all as specified and shown on drawings.
Construction of AHU ROOM with permanent specification, complete all as specified and shown on drawings.
Sch A Part II (INTERNAL WATER SUPPLY)
Lump sum price worked out by the contractor for Internal Water Supply as listed in Sch ‘A’ Part II .
Sch A Part III (INTERNAL ELECTRIFICATION)
Lump sum price worked out by the contractor for Internal electrification as listed in Sch ‘A’ Part III .
Sch A Part IV (EXTERNAL WATER SUPPLY)
Lump sum price worked out by the contractor for External water supply as listed in Sch ‘A’ Part IV .
Sch A Part V (EXTERNAL ELECTRIFICATION)
Lump sum price worked out by the contractor for External Electrification as listed in Sch ‘A’ Part V.
Sch A Part VI ( AREA DRAINAGE)
Lump sum price worked out by the contractor for Area drainage as listed in Sch ‘A’ Part VI.
Sch A Part VII (ROAD, PATH AND CULVERT)
Lump sum price worked out by the contractor for Road, Path and culvert as listed in Sch ‘A’ Part VII
Sch A Part VIII (DG SET AND LIGHTENING PROTECTION)
Lump sum price worked out by the contractor for Road,Path & Culvert as listed in Sch ‘A’ Part VIII
Sch A Part IX (ADDN /ALTN WORKS)
Lump sum price worked out by the contractor for compound wall/ fencing as listed in Sch ‘A’ Part IX
Sch A Part X (FIRE POINT)
Lump sum price worked out by the contractor for fire point and cooler stand as listed in Sch ‘A’ Part X
Sch A Part XI (SITE CLEARANCE, EXCAVATION AND EARTH WORK)
Lump sum price worked out by the contractor for Site clearance, Excavation & Earth Work as listed in Sch ‘A’ Part XI
Sch A Part XII (Miscellaneous Items of B/R and E/M)
M & L for roof treatment with APP based polymeric membrane, 3mm thick (minimum), weighting 3.5 Kg/Sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/sqm) shall be applied over and including applying one coat of hot blown bitumen grade 85/25 confirming to IS-702 @ 1.2 Kg per sqm over a coat of bituminous primer @ 0.3 ltre per Sqm surface, applicatioin of APP modified membrane shall be by torch application . The overlaps shall be minimum 100mm on the transverse direction and 75 mm on logitudinal direction. Complete removal of existing bituminous felt treatment over roof surfaces including wire brushing, cleaning surfaces and removing malba out of Def land exc 0.50 KM but n.exc 1.50 KM and complete all as specified and directed.
S&F in repairs cast copper alloy chromium plated health faucet of make Jaguar Cat Part ALDCHR565 or equivalent from plumber, Marc or Prayag including 1m long easy flex tube & hook complete all as specified and as directed
M & L for removing loose and broken concrete by chiseling / picking etc upto a depth of 80 to 100mm from columns, beams and similar structural members, cutting edges, clearing the dismantled portion with wire brushes etc., to remove dust, dirt and other foreign particles etc., and washing with clean water with pressure including necessary scaffolding and removal of debris to a distance n.exc 50m, complete all as specified and as directed by Engineer-in-Charge.
M&L for applying one coat epoxy bonding agent @ 2.6 sqm/lit or as per manufactures instruction to old concrete surfaces of columns, beams and similar structural members complete all as specificed and as per directed by Engineer-in-Charge. Make Nitobond EP of Fosroc or equivalent
M&L for spraying curing compound as per manufactures instruction on freshly cast concrete surfaces all as specified. Make : Concure WB white of Fosroc or equivalent.
M&L for non shrink, cementitous micro concrete mixed with 12.5mm graded stone aggregate using Fosroc Renderoc RG or equivalent by weight (18 Kg Aggregate :25 Kg Renderoc RG) respectively (as per manufatures instruction) laid in average thickness 80 to 100 mm in surface of columns, beams, parapets and similar structural members including use and waste of water tight form work, complete all as specificed and as per directed by Engineer-in-Charge.
M&L for setting in cement mortar 1:3 and flaunching with cement concrete 1:2:4 type B-l cast iron manhole covers and frames, heavy duty, any type and size 600 mm.
Supplying and fixing for aluminium composite panel work using frame work fixed aluminium section of size 50 x 25 box section vertically and 38x 25 mm horizontally as per manufacturer's instructions, L angle cleats to fix the above ALU frame, fabricating and fixing panels of aluminium composite panel cladding in pan shape of approved shades made oout of 4 mm thick alumium composite panel (consisiting of 3 mm thick FR grade mineral core sandwitched between two alumiunm sheets each of 0.5 mm thick). The aluminium composite panel cladding sheet shall be coil coated with kyner 500 based PVDF / lumiflon based fluoropolymer resin coating of approved colour and shade on face one and polymer (service) coating on other, fixed using stainless steel screws, nuts, bolts, washers, cleats, waether silicon sealent, backer rods, ACP cladding cover in front side only the MS frame 50 x 50 x 6 mm "L" angle / triangle portition including painting and finishes complete MAKE : ARMSTRONG / ALUCOBOND.
S&F powder coated aluminium deco grills size cx. 4mmx4mm, 8mm thick and aperture n.exc. 80 mm width and including fixing with aluminium channel, 1 mm thick with steel screw and tint match with existing complete all as specified and as directed.
S & F Powder coated anodised aluminium door with door frame of size 100mmX44mmX2.5mm thick and shutter with styles 85mmX44mmX25mm thick rails 110mmX44mmX2.5mm thick incl 6mm glass of make Modi/Atul and partly/fully fixed with 12mm thick prelaminated particle board fixed with aluminium snap beading and rubber gasket. The each shutter fitted with one aluminium sliding bolt of 250mm, 01 nos tower bolt 200mm , 02 nos handle of approved make all as specified and directed by Engr-in-charge.
S & F in repairs Powder coated anodised aluminium partition with main frame of size 101.6x44.5 - 3mm thick for bottom rail and 2.5mm thick for intermidiate and top rail with standard channel at bottom incl 6mm glass of make Modi/Atul and partly/fully fixed with 12mm thick prelaminated particle board fixed with aluminium snap beading including necessary joining cleat, glazing clips, snap beading, rubber beading etc approved make all as specified & directed by Engr-in-charge.
S & F Powder coated anodised aluminium partition with main frame of size 101.6x44.5 - 3mm thick for bottom rail and 2.5mm thick for intermidiate and top rail with standard channel at bottom incl 6mm glass of make Modi/Atul and partly/fully fixed with 12mm thick prelaminated particle board fixed with aluminium snap beading including necessary joining cleat, glazing clips, snap beading, rubber beading etc approved make all as specified & directed.
M&L Frosted Matt acrylic Plexiglass DIY projects 3mm sheet fix on ventilators/window with aluminium frame work complete all as specified and directed.
Supply and fixing mild steel Automatic (Mortrised), rolling shutter of 1.2 mm thick mild steel sheet and 75 mm wide 3.1 mm thick side rails / guides with hood cover 0.8 mm thick of same material operated by single push button switch to open and close the shutter having heavy duty drives of capacity 3000 Kg alongwith hand crank or chain drive for maual operation of shutter ( in case of powerfailure) Shutter drives shall be built with anti drop device and additional safety catch to avoid free fall with one pair of safety lever lock plate. Shutter shall be painted with two coats of approved synthetic colour paint over a red oxide primer. MAKE : LEAPTOR (AVIANS INNOVATIONS TECHNOLGY PVT LTD), Shidharth shutters and Automations, Gandhi Automations Pvt Ltd or equivalent as approved by the GE.
M &b L for Jhonson Endura heavy duty coloured tiles 20 mm thick (Square / rectangular) size 300 x 300 x 20 mm thick fixed in floor et, laid as per maunfacturer instructions, complete and pointed in coloured cement to match with shade of tiles, complete all as specifed and directed.
Material and labour for construction of new valve chamber size 600mm x600mm x600mm including necessary earth work in any type of soil, PCC foundation (1:3:6 ) type C-2 , 40mm graded stone aggregate as in base concrete, brick work in CM 1:6 with 10 mm thick plaster internally and 15 mm thick externally in CM 1:4, 4 mm thick MS cover with hinges and locking arrangement fixed to angle iron frame made out of 40x40x6 mm MS angles complete with 2 coat of synthetic enamel paint over one coat of red oxide primer on all metal works and three coats of white wash on all plastered surface of valve chambers complete all as specified and as directed by Engr in charge.
Supply, erecting, testing and commissioning complete of manufacturere or OEM manufactured, static silent (Sound Proof enclosure) Water cooled Diesel Engine Driven Generating Set capable of delivering 200 KVA (160KW), water cooled, 415 Volts (AC three phase, 4 wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of alternator coupled to a matchingcapacity D G Set engine, through flixible coupling and mounted on common base frame with AVM with and complete with Automatic on Mains Failure (AMF) control panel standardized by manufacturer, fuel tank with mounting arrrangements , draw plug, air vent inlet and outlet connection level indicator exhaust pipe all suitable for conditions at Maharajpur including PCC foundation as per manufacture instructions , anti vibration pads, including all features to comply with latest CPCB guidelines and Comprising of followings:-
(i) ENGINE (Prime Mover) : Diesel Engine 1500 RPM,direct injection, multi cylinders, four stroke confirming to ISO3046/BS 5514, water cooled, naturally turbo charged, capable of giving adequate BHP at outdoor atmospheric conditions at Maharajpur(Gwlior) (Taking all derating factor into consideration to drive Alternator capable of delivering 200KVA(160KW), 12/24 Volt (as per manufacturer recommendations) electric battery start, complete with fly wheel all standard fittings/fixtures as per manufacturer and including suitable panel with tachometer, lub oil temperature, pressure guage and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor (ECPG) and Engine protection system (Shut down at High water temperature, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumables etc.The scope of supply includes: - (a) Electrical starter motor 12V /24V as per manufacturer (b) Battery charging alternator (c) Fuel system with electronic governor with mechanical governor as back up (d) Dual spin-on fuel filter with replaceable cartridge (e) Spin-on full flow lub oil filter and pump (f) Residential type silencer (g) Dry type replaceable paper element air cleaner (h) Recovery bottle (j) Lube oil cooler (k) 2Nos 12V maintenance free 180AH battery with lead and terminals (l) Flywheel and flywheel housing to shut single bearing altornator.
(vi) Foundation/Plinth/Base : Shall be provided as per manufacturers recommendations, however minimum 0.5 m space should be available all around the Standard height for plinth shall not be less than 0.5 M.(vii) Diesel storage tank of adequate capacity for storage of diesel for 12 hours operation of Gen Set. (viii) Fuel strainer and fuel tank with air vent. (ix) copper cable connection from alternator to DG Set AMF panel as direcected . (X) Tools ( As per manufacturers instructions ;- (aa) 'D' spanners - 01 Set. (ab) Ring spanners - 01 Set. (ac) Screw driver 5" to 12" - 01 Set. (ad) Cutting plier 9" - 01 No. (ae) Hammer 2 LBS - 01 No (XI) Two years spare parts suitable for the DG Set (a) Air filter cartridge - 06 Nos (b) Fuel filter cartridge - - 06 Nos (c) Battery testing meter (Hydro) - 01 No. (d) Suitable fan belt set - 01 set. (e) Regulator cut out - 06 Nos. Note :- The following items are deemed to be included in the rate quoted for all DG sets :- (a) Air filter cartridge - 06 Nos. (b) Fuel filter cartridge - - 06 Nos. (c) Battery testing meter (Hydro) - 01 No. (d) Suitable fan belt set - 01 set. (e) Regulator cut out - 06 Nos. Note :- The following items are deemed to be included in the rate quoted for all DG sets :- (i) DHPP for testing purpose shall be supplied by the contractor without any extra cost to Govt. (ii) The contractor shall arrange for artificial load (water load) for testing incldg fuel for final testing of DG set at site and the cost is deemed to be including in above offer. (iii) Testing of sound level should carried out at the site in presence of officer authorised by Accepting officer.
Dismantling and taking down unserviceable alluminium air termination rods/earting test points etc all as directed.
Dismantling and taking down unserviceable alluminium strip of any size for bld lightening protection and makiing good distrubed surfaces all as directed.
Dismantling and taking down unserviceable GI pipe of 40/50mm dia for air termination installatin/ earth continuity strip protection inclding gi sockets etc makiing good distrubed surfaces complete all as directed.
Taking down submain wiring aluminium copper of any size including earth continuity conductor on teak wood or conduit and removing from site and making good the disturbed surface of wall etc complete all as specified and directed.
Supply, Install, testing and commisioning of factory made floor mounted LT cubical panel Conforming to CPRI Specification and manufactured by CPRI approved manufacturer panel board outdoor type (double door) made out of 3.15 mm thick CRCA sheet totally enclosed with necessary ventilators, weather, dust and vermin proof IP 54 minimum wiith front and rear opening and locking arrangement 415 volts, 3 phase, 50 Hz having copper bus bar of capacity 500 Amps and of suitable size to house all LT switch gears and accessories as mentioned below and full neutral duly colour coded and for neutral supported with DMC / SMC insulators colour coded, complete connection from bus bar to MCCB with suitable copper cable. Panel Board shall be grouted in ground with suitable size of foundation in PCC 1:2:4 type B 1 MS channels for base frame 50x50x6 mm and supports, GI nut, bolts, washers etc. The panel board shall be powder coated and red oxide primed. The following items shall be provided in each compartment :- (a) Digital voltmeter - 01 No. (b) Digital Ammeter - 01 No. (c) Three indication LED lamp (d) Power factor - 01 Nos (e) KWH meter - 01 No. (A) INCOMING :- MCCB 4 pole, 320 Amps 36 KA - 01 No, Ics:Ics with adjustable thermal settings. (B) OUT GOING :- (a) MCCB 4 pole, 250 Amps 35 KA - 01 No, Ics:Ics with fixed thermal settings. (b) MCCB 4 pole, 63 Amps 25 KA - 03 Nos, Ics:Ics with fixed thermal settings.
Boring horizontal holes of 150 mm dia in required length across the road, pavement, hard standing by trenchless technology (without disturbing top surface) using ultra sounding technique by deploying required machinery in & including insertion of HDPE pipe of 150 mm bore suitable for 0.4 mpa working pressure in the board hole all as specified and directed.
S & Fixing wall/surface mounted type LED light fitting complete with LED lamp of 1x20 watt /1x24w (4 ft) , extruded aluminium heat sink provided for efficient heat dissipation & integrated electrionic driver complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable .Make:- Cromption Cat part No- LCCLB24-CDL, Havells Cat Part No. ENDURALINERNEOBS20WLED865SPCWH, Wipro Cat Part No. LL20-221-XXX-65AL1
Supply and fixing PVC body exhaust fan 250 mm sweep AC, 240 volts fixed as per manufacturer instruction, connecting with and including 1.5 Sqmm copper conductor, PVC insulated and PVC sheathed three core cable including provn of hole and aluminium frame etc for fixing the fan as required at site complete.
S&F LED street light 45 watt made up of pressure dia cast housing with toughned glass and individual LEDs with secondry optics and IP66 protection accessories including GI light grade tube 40 mm bore bracket of required shape & size, with and connecting the fitting to electric source with using copper conductor 23/0.0076 flexible twisted twin core cable , including all accessories and fixing arrangements for fixing the light fitting to walls / pillars complete all as specified and directed Make :- Bajaj cat part No BRTFG 45W LED WW / WIPRO-LR02-501-XXX-57-G1 / CROMPTON-LSTS-45-CDL-M.
Supply and fixing factory made epoxy powder coated distribution board VTP & N 8 ways (TPN MCCB DB) with metal door (IP-54 protection) and fixed flush to wall and suitable for universal mounting and including 250 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts and suitable for one TP-MCCB 63 Amps as incomer and 12 SP MCBs or 4 TP MCBs (or any combination of SP/TP MCBs ) outgoings including disconnecting and taking down of old unserviceable distribution board with all fitting and fixture complete all as specified and directed.Make :- Legrand cat Nos-6077 71 / Indoasian cat ref.-812047 / Havells cat. N.-DHDMTHDDRW08
Supply & fix flameproof distribution board 8 way single pole & neutral in LM-6 metal enclosures with and including 01 No MCBs single pole and neutral 40 Amps & 06 Nos MCB single pole 16 Amps `C’ series complete all as specified and directed.
Supply & fix CMRI certificate LED flameproof 1x18w or next higher size tube light fitting as per IS : 2148 / 1981 & 2206 (Part-I )1984, Temperature class T-4, & made of cast aluminum alloy LM-6 having inside & outside light grey powder coating shade No 631 as per IS: 5 & one No internal earthing terminal and 02 Nos external earthings of screw of M6- size with 02 Nos plain washers heat resistant glass complete all as specified and directed.
Supply & fixing in replacement flame proof FLP Well glass light 60 W LED or next higher size fittings as per IS : 2148 / 1981 & 2206 (Part-I )1984, Temperature class T-4, & made of cast aluminum alloy LM-6 having inside & outside light grey powder coating shade No 631 as per IS: 5 & one No internal earthing terminal and 02 Nos external earthings of screw of M6- size with 02 Nos plain washers heat resistant glass complete all as specified and directed.
Supply & fixing flame proof air circulator fans 230 volts single phase Speed 1440 RPM and oscillation 1440 CFM 600 mm sweep complete all as specified and directed.
Supply, installation, commissioning & testing of horizontal, water-cooled, floor-mounted compact chiller unit of actual Minimum Cooling Capacity 3Xnot less than 37 TR (2W+1S), at local ambient conditions at Gwalior , with scroll-type multiple compressor(s), star/delta starter, S/T type water cooled condenser, S/T type insulated evaporator , step control as per manufacturer , common base frame, interconnected copper refrigerant piping, vibration isolators, gauge panel, automatic safety controls, Ozone friendly CFC-free refrigerant gas R-407C/134a & oil, polyvinyl nitrile rubber insulation of chiller and suction pipe, etc. The motor shall be suitable for operation on 415 V ± 10%, 3-Phase, 50 Hz AC power supply. The chiller unit shall be complete with its microprocessor based control panel with starter for motors and condensors, under and over voltage protection, single phase preventor, communication card starter with main-switch. The chiller unit should be complete with discharge service valves to isolate refrigeration circuit, vibration isolators, antifreeze thermostat. Necessary civil work viz. PCC foundation , iron structure /PCC for placement of chillers , shall be covered in the scope of work. The chiller shall be as per the approved particular technical specifications and shall meet the following tentative design criteria:- [a] Max Local ambient temperature: 105 °F. [b] Temperaturedrop through chiller : 4.4°C. [c] Evaporator fouling factor: 0.0001° hr.sq m2 / K Cal [d] Refrigerant (Ozone friendly type): R407C/410/134a.
Note : 1. Temperature to be maintained by the plant is 23+2 °C, 60+10 % RH. 2. The contractor will check required TR of the chillers. In case , there is requirement of higher capacity chiller than that mentioned in tender for maintaining temperature and humididty as specified above, he shall provide detailed Heat Load calculation in support of his claim within one month of acceptance of tender . In case of requirement of TR more than specified in tender, financial adjustment will be done through DO. 3. Minimum CoP = 4.7 and Min IPLV = 5.8 4. The noise level at 2 m should not exceed 75 dba. 5. The rate quoted is inclusive of micrprocessor controlled capacitior bank to ensure PF of 0.95 6. All cabling will be with XLPE armoured1100 volt fire retardent cable internal wiring in control panel should be with PVC insulated FRLSH copper cable. 7. Rate quoted is inclusive of required capacity of capacitor bank to ensure PF 0.95.
Supply, installation, testing and commissioning of end-suction & top-discharge, back pullout type , casing centrifugal pumps for chilled water re-circulation-03 Nos (2W+1S), complete with cast iron body, bronze impeller, mechanical seals, TEFC ,fan cooled type, squirrel cage high efficiency, IE3 class induction motor, base plate, mounting channel frame, accessories and fittings i.e. mechanical seal,drains, coupling, coupling guard, vibration isolation arrangement by means of spring/rubber type mounting of the following specifications, suitable for operation on 415 V ±10%, 50Hz, 3-Phase AC supply. The Pumps shall be insulated with expanded polysterene (TF quality) of suitable thickness but not less than 25 mm. The pump shall be suitable for given duty point as mentioned under :- [a] Capacity: 7 LPS approx [b] Head: 20 m [c] Impeller: Bronze [d] Approximate Motor Rating: 3.0 HP Note : 1. Pumpsets will be arranged in 2W+1S configuration. Neccessary plumbing work will be done accordingly. 2. Contractor will provide calculation of Head and Hp of Pump. In case of deviation in Hp more than specified in tender, financial adjustment will be done through DO.
Supply, installation, testing and commissioning of end-suction & top-discharge, back pullout type ,centrifugal pumps for condensor water re-circulation-03 Nos (2W+1S), complete with cast iron body, bronze impeller, mechanical seals, TEFC , fan cooled type, squirrel cage high efficiency, IE3 class induction ,motor, base plate, mounting channel frame, accessories and fittings i.e. mechanical seal, drains, coupling, coupling guard, vibration isolation arrangement by means of spring/rubber type mounting of the following specifications, suitable for operation on 415 V ±10%, 50Hz, 3-Phase AC supply :- [a] Capacity: 9.46 LPS. [b] Head: 20 m. [c] Impeller: Bronze. [d] Approximate Motor Rating: 4.0 HP. Note : 1. Pumpsets will be arranged in 2W+1S configuration. Neccessary plumbing work will be done accordingly. 2. Contractor will provide calculation of Head and Hp of Pump. In case of deviation in hp more than specified in tender, financial adjustment will be done through DO.
Supply, installation, testing and commissioning of FRP bottle-shaped induced draft counter-flow,CTI certified cooling tower of capacity not less than 45 TR and Flow rate matching with condensor water pump complete with FRP basin of capacity adequate for 30 min operation without make up water , PVC fills, SS sprinkler pipe with polypropylenenozzle, FRP body, hot-dip galvanized suction and discharge screen, access ladder, weather-proof TEFC energy efficient electric motor complying to IS 12615,IE 3 class, die-cast aluminium/FRP blade fan, motor guard, inlet, outlet, make up and quick-fill arrangement, drain and over-flow nozzle connections, etc. Note : 1. Cooling Tower should be suitable for refrigeration capacity plus heat of compression which is generally 20 % of refigeration capacity. 2. Cooling Tower should be suitable to meet heat load in monsoon as well as summer for weather conditions of Gwalior. 3. Cooling Towers will be arranged in 2W+1S configuration and plumbing works will be done accordingly. 4. Rate quoted is inclusive of foundation for installation of cooling towers as per manufacturer's / OEM instructions
Supply, installation, testing and commissioning of double-skin type horizontal, floor-mounted, top/side discharge air handling unit of capacity 12000 CFM at 75 mm water gauge static pressure having corrosion resistant extruded aluminum hollow profile with thermal break, heavy gauge galvanized steel channel base frame, 40 mm double skin panel with pressure injected CFC & HCFC free PUF with 'k' value of 0.02 W/°C m & density not less than 38 kg/cum, pre-coated pre-plasticized galvanized outer and inner skin 1.2 mm thick with 120 gm/sq mm thick Zn coating, air-tight casing using gaskets and self-adhesive tapes, AMCA certified energy efficient fans with double inlet double width forward curved impellers for high static pressure mounted on aluminum extruded slide rail base frame, copper coils of 6 rows deep with anti-corrosion Aluminum fins with combination of hot and chilled , PVC Naylon hinges & handles, view port and marine lamp, limit switch, SS-304 drain pan (0.8 mm thick) of sufficient width and difffernetial slope to drain condensate water insulated wth 10 mm PUF/nitril rubber , pre-filters, inspection windows/doors, mixing box and supply/return/fresh air dampers, moisture drop eliminators. NOTE :- Cost of necessary civil work viz. PCC foundation for placement of AHU and electric cum control panel for auto operation of AHU etc. shall be covered in the quoted rate. The AHU shall be as per the approved particular technical specifications and the following design criteria. [a] Suitable DIDW forward fan with AMCA certified blower having outlet velocity not exceeding 9.2 m/s. [b] 4 Pole, TEFC, high efficiency, squirrel cage induction motor drive having BHP rating 20% higher than the peak capacity, suitable for 415 V ±10%, 50 Hz, 3-Phase AC power supply. [c] V-belt drive assembly with pulleys, 2 nos suitably matched oil resistant belts, guard, etc., double canvass connections with zip to discharge duct/plenum, etc. [d] 50 mm thick, washable HDPE, 90% down 10 micron pre-filters, Micro V filter having dust filtration capacity 95% down to 5 micron filters, fixing framework, hinge type access doors, etc.
Supply, installation, testing and commissioning of PAN-type humidifier capacity not less than 23 l /hr evaporation rate , made out of SS-304 sheet welded construction with unitized stainless steel reservoir, divided into two chambers from inside having 25 mm thick fiberglass insulation cladded with aluminum foil, snap-acting humidistat, support legs for free-standing or wall hanging brackets for wall-mounting, factory mounted & wired humidifier control cabinet, steam outlet nozzle, water make-up, drain, over-flow, quick fill connections, immersion heaters made of stainless steel, terminal blocks suitable for field power and control wiring and safety thermostat.
Supply, installation, testing and commissioning of SS 304 shell type vertical electric hot water generator suitable for 37 kW heat output for hot water output with water inlet at 45º C and outlet 50º C, working pressure 100 PSIg ( tested for 350 psig pressure), having 50 mm thick insulation of resin bonded with fiber glasswool with 0.63 mm aluminium cladding, thermostat for individual step, digital thermometer for inlet & outlet pipes, pressure gauge with ball valve for inlet & outlet pipes, SCR based stepless linear controller, float switch, audio/visual alarm for low water level, auto vent audio/visual alarm for high temperature, pressure relief valve, door switch, safety thermostat, etc. complete as specified and directed.
Supply, install, testing and coimmissioning centrifugal monoblockpump for pumping hot water from HWG to heating coil in AHU with energy efficient motor confirming to IS 12615. The pump shall be suitable for given duty point [a] Capacity: 85 US GPM approx [b] Head: 20 m[c] Impeller: Bronze ,Shaft High Tensile steel, Pump Mpotor body : CI [d] Approximate Motor Rating: 2.5 HP. Note : 1. Pumpsets will be arranged in 1W+1S configuration. Neccessary plumbing work will be done accordingly. 2. Contractor will provide calculation of Head and HP of Pump. In case of deviation in Hp more than specified in tender, financial adjustment will be done through DO. 3. Rate quoted is inclusive of foundation as per OEM recommendation
Supply, installation, testing and commissioning of MS ERW Class 'C' HOT water piping with all necessary fittings i.e. bends, tees, reducers, flanges, structural support, wooden blocks, air-purge valves, drain-valves, etc. thermally insulated with Expanded polystyrene (TF quality) 50mm thickness finished with aluminium sheets of 0.5mm thickness as specified in particular specifications.
Supply, installation, testing & commissioning of MS Class 'C' INSIDE PLANT ROOM conforming to IS 1239 chilled water piping, cut to required length and installed with welded joints, including all necessary fittings such as elbows, tees, bends, reducers, flanges, supports, etc.,clamps, vibration isolators duly insulated with expanded polystyrene (TF quality) min density 20 kg per cum, min thickness 50 mm , finished with 24 gauge aluminimum sheet over vapour barrier of 120 gm per sqm olythene sheet with 50 mm overlap, tied down with lacing wire with type 3 grade I roofing feltstrip at joints incl making good to damages to building as per adjoining surface
Supply, installation, testing & commissioning of 100 mm MS Nominal Bore Class 'C' OUTSIDE PLANT ROOM conforming to IS 1239 chilled water piping, cut to required length and installed with welded joints, including all necessary fittings such as elbows, tees, bends, reducers, flanges, supports, etc.,clamps, vibration isolators duly insulated with expanded polystyrene (TF quality) min density 20 kg per cum, min thickness 50 mm , finished with 24 gauge Galvanised steel sheet over vapour barrier of 120 gm per sqm olythene sheet with 50 mm overlap, tied down with lacing wire with type 3 grade I roofing feltstrip at joints incl making good to damages to building as per adjoining surface
Supply, installation, testing & commissioning of MS Class 'C' OUTSIDE PLANT ROOM AND UNDER GROUND conforming to IS 1239 chilled water piping, cut to required length and installed with welded joints, including all necessary fittings such as elbows, tees, bends, reducers, flanges, supports, etc.,clamps, vibration isolators duly insulated with expanded polystyrene (TF quality) min density 20 kg per cum, min thickness 50 mm covered with polythene faced hessian with 50 mm overlap, all joints sealed with bitumen, layer of 0.2mmx50 mm GI wire netting laced with GI wire, finished with 2 layer of plaster in CM 1:4 , each of 10 mm thickness for the following size :-
80 MM NOMINAL BORE. NOTE FOR ITEM NO 12.053 and 12.054 :- All pipes, pipe support, structure shall be painted with two coats of synthetic enamel paint of color as per colour coding over one coat of red oxide primer with lettering and marking of flow in white paint.
Supply, installation, testing and commissioning of MS ERW Class 'C' conforming to IS 1239 condenser water piping with all necessary fittings i.e. bends, tees, reducers, flanges, , pipe resting on half round wooden blocks,structural steel support , etc. as specified in particular specifications for the following sizes :- Note : All pipes, pipe support, structure shall be painted with two coats of synthetic enamel paint of color as per colour coding over one coat of red oxide primer with lettering and marking of flow in white paint
(a) 125 mm NB
(b) 100 mm NB
Supply, installation, testing and commissioning of MS ERW Class 'C' conforming to IS 1239 condenser water piping with all necessary fittings i.e. bends, tees, reducers, flanges, , laid underground with two coats of tarfelt each having thickness of 2mm and stick with hot bitumen outside the building for the following sizes :-
BUTTERFLY VALVE
Supply, installation, testing and commissioning of PN 1.6 rated butterfly valves of integral moulded design, duly insulated with companion flanges, nuts, bolts, gaskets etc. with cast iron body, seat of black nitrile rubber, nylon coated S.G. iron disc, PTFE coated SS (AISI 410) shaft etc. as required, conforming to BS: 5155, MSS SP 67 & API 609, designed to fit without gaskets between mating flanges, suitable for flow in either direction and seal in both directions for the following sizes :-
(a) 50 mm NB insulated with uniformly cut pieces of expanded polystyrene covered with 500 GSM polythene faced hessian clot with 50 mm overlap and 26 mm aluminium cladding
(b) 80 mm NB insulated with uniformly cut pieces of expanded polystyrene covered with 500 GSM polythene faced hessian clot with 50 mm overlap and 26 mm aluminium cladding
© 100 mm NB without insulation
(d) 125 mm NB without insulation
Supply, installation, testing & commissioning of Y-type strainer with CI/MS body, bolted cover, flanged ends, basket of brass/ bronze/ SS wire mesh complete with flanges, nuts-bolts, gaskets duly insulated with 50 mm thick TF quality EPS & covered with 12 mm sand-cement plasterfor the following :-
(a) 80 mm Nominal bore insulated with uniformly cut pieces of expanded polystyrene covered with 500 GSM polythene faced hessian clot with 50 mm overlap and 26 mm aluminium cladding
(b) 125 mm Nominal bore without insulation
© 100 mm Nominal bore without insulation
Supply, installtion,testing and commissionig of Water Swing Check type PN 1.6 rated Non- Return Valve with cast iron body, flanges, gaskets etc. with insulation for the following :-
(a) 100 mm NB without insulation
(b) 80 mm NB insulated with uniformly cut pieces of expanded polystyrene covered with 500 GSM polythene faced hessian clot with 50 mm overlap and 26 mm aluminium cladding
Supply, installation, testing and commissioning of paddle type water flow switch, having operating pressure 1000 kPa, withstand pressure 91750 kPa, insulation resistance over 100 Ω, withstand voltage 1500 V AC for 1 minute, contact point life of 1000 k cycles and bellows life 500 k cycles complete with control wiring and accessories, etc. as specified in particular specifications.suitable to control approximate maximum flow rate of 115 US-gpm and installation in 80 mm chilledwaterline insulated with uniformly cut pieces of expanded polystyrene covered with 500 GSM plythene faced hessian clot with 50 mm overlap nd 26 mm aluminium cladding
All as above item No 12.076 but Water Flow Switch suitable to control approximate maximum flow rate of 160 US-gpm and installation in 100 mm condensor water line without any insulation. Note for item No. 12.076 & 12.077 : In case of requirement of flow switch of flow rate varying more than +20% as specified in the tender, financial adjustment will be done through DO.
Supply, installation, testing and commissioning of 2-way, globe type, PN 1.6 rated, BALANCING VALVE as per following specification for the following sizes :-
Nominal pressure 16 bar Medium Temperature -10~ +110 Maximum Body Material IS:210, FG 220 CI Stem Material ASTM A276,GR SS 410 Disc Material Stainless steel Disc Hand Wheel Cast Iron Leakage Rate No visible leakage Medium Type Water Flange standard ISO7005-1 (GB/T 9113) Shell Test pressure 24bar Seal Test pressure 17bar
100 mm NB without insulation
80 mm NB insulated with uniformly cut pieces of expanded polystyrene covered with 500 GSM polythene faced hessian clot with 50 mm overlap and 26 mm aluminium cladding
Supply, installation, testing and commissioning of CI 3-way mixing /Tempearature control valve, 80 mm NB insulated with uniformly cut pieces of expanded polystyrene covered with 500 GSM plythene faced hessian clot with 50 mm overlap nd 26 mm aluminium claddingsuitable for operation up-to 10 bar, with electronically operated actuator for AHUs. Water flow through the valve shall be regulated by rotation of brass slipper between the main and the bypass ports; it shall be possible to manually rotate the brass slipper through 360° and interchange the main and the common ports, to facilitate installation at site. All internals of the valve shall be rust-proof and the 'O' ring shall be of elastomeric insulation. The valve actuator shall be of electronic type with DC motor, the actuator's angle of rotation shall be 90°, it shall be without any limit switches and shall be overload-proof. It shall have an indicator to indicate the position and push-button to disengage the gear train for manual operation. All complete as specified in particular specification.
S & F of CL 150 # rated 25 mm ball valve, designed & manufactured as per IS: 9890 (1981) and tested as per BS 6755 Part- I, having floating type three piece design, CS body, SS- 304 ball, PTFE seal/packing/gasket, CS fastners and lever and screwed/socket weld end connection, etc. with accessories as specified in particular specifications.
Supply, installation, testing & commissioning of 100 mm dial type bourdan pressure gauge of appropriate range and SS isolation valves & other fitting in chilled water, hot water and condensor water line
Supply, installation, testing & commissioning of set of 150 mm dial type temperature gauge of appropriate range with thermowell and SS valves &other fitting in chilled water, hot water and condensor water line
Supply, installation, testing & commissioning of 25 mm NB auto air-purge valve with all fittings viz bend, elbow, nipple etc and drain valve for chilled water piping
Supply, installation, testing & commissioning of 50 mm NB auto air-vent valve with all fittings viz bend, elbow, nipple etc and drain valve for chilled water piping
Supply, installation, testing & commissioning of 65 mm NB pot-type strainer with C.I / MS body, bolted cover, flanged ends, basket of brass/ bronze/ SS wire mesh with flanges, nuts-bolts, gaskets
Supply & Fixing 32 mm Nominl bore GI medium grade pipe with all fittings insulated for draining water
Supply & Fixing 32 mm Nominal bore GI medium grade pipe with all fittings
Supply & Fixing 32 mm gate valve complete with iron wheel head, screwed both ends
Supplying and fixing pressure gauge plug with all fittings , isolation valves etc
Supplying and fixing screwed plugs for 50 mm-125 mm pipe line
Supply, installation, testing, balancing and commissioning of galvanized steel sheet (G.S.S.) square/rectangular / round ducting, for supply/return air, fabricated from galvanized steel sheet of the following thicknesses having zinc coating of 120 gm/sq m total on both sides complete with neprene rubber gaskets, elbows, splitters, vanes, hangers, structura steel supports etc. as per IS: 655/1963 with required scaffolding work to install the ducts at site
(a) 26 gauge galvanized sheet steel (0.45 mm)
(b) 24 gauge galvanized sheet steel (0.63 mm)
© 22 gauge galvanized sheet steel (0.70 mm)
Supply, installation, testing & commissioning of supply air diffusers/grilles of extruded powder coated aluminum sections with duly powder coated with aluminium volume control; damper , anti smudge ring and removable core
Supply, installation, testing & commissioning of return air diffusers/grilles of extruded powder coated aluminum sections witghout damper
Supply, installation, testing and commissioning of fire and smoke damper of required sizecomplete. The fire dampers shall be motorised and spring return type so as to close damper automtically in event of power failure. Damper should be complete with electronic temperature sensor and electrically operated actuator and interconnecting wiring between AHU and damper
Fire Damper
Actuator with smoke fire sensor
Note for Item No. 12.094 to 12.102 1. GI sheet will conform to IS 277. Rate quoted for ducting is inclusive of all accessories, hanging arrangement required for duct work 2. Before executig duct work, design and drawings as per para 41 will be get approved from Accepting Officer
S & F closed cell Class O, elastomeric nitrile rubber 19 mm thick thermal insulation for SA/RA ductsinsulation with aluminum foil 0.1 mm laminated on one side, having thermal conductivity not exceeding 0.037 W/mK at mean temperature of 20° C as per EN 12667,density (without the foil )between 40 to 55 kg/cum applied using manufacturer recommended rubber based adhesive
Supply & Fixing under deck insulation with resin bonded fobre glass wool conforming to IS 8913, density 24 kg per cub meter, 60 mm thick, wrapped in 200 +/- 20 GSM virgin polythene bags fixed to ceiling with metallic cleat 50x50x3 mm at 60 cm ctentre to centre and wire mesh of 12.5 mmx24 G wire
S & F XLPE insulated stranded, aluminum conductor armored cables of 1100+B125 volt grade, Including cost of all crimping lugs and single compression glands, cable sockets insulating tape, sealing compound for the following sizes ;-
(a) 3.5 Core x 70 sq mm Aluminium conductor cable
(b) 4 Core x 16 sq mm Aluminium conductor cable
© 4 Core x 4 sq mm Copper conductor cable
Supply, installation, testing and commissioning of floor mounted, indoor duty, cubicle & compartmentalized, front access type, medium voltage, CPRI type tested , factory fabricated, IP 42, powder coated, suitable for operation on 450 Volts, 3 phase, 4 wire, 50 Hz, AC supply complete with all interconnections and consisting of all accessories like aluminum Bus Bar ( min 500 A capacity) , Indicating lamps, Push buttons, CTs, Digital Ampere, Voltage, Frequency & KWH meter, Danger Plate, Lifting Hooks, Feeder Name Plates suitable for the following feeders electric panel of dust and vermin proof construction, front openable doors and shutters with locking arrangement, made out of 14 SWG (2.0 mm thick) CRCA sheet steel, front openable, single door system lockable/openable with "U' type gasket to make the inner shell completely vermin proof having chromium plated locks (2 Nos in each compartment). All control wiring shall be with not less than 1.5 Sqmm multistranded copper conductor and shall be properly bunched. tied, ferruled for proper identification and crimped with adequite size of lugs. The cubical shall have a bottom channel of size 75x75x5 mm duly pained with zinc based primer. A detachable predrilled gland plate of thickness 3.15 mm should be used at the bottom, (Note : The Panel shall be of suitable size to accommodate all the accessories mentioned below , installed on Pedestal made out of angle iron of size 50 mm x 50 mm x 6 mm & earth work, PCC foundation, suitable cable glands for cable entry etc.)
[i] Incoming Feeder: 320 A,36 kA FP MCCB,415 V, Fixed thermal and magnetic setting, Ics=Icu with spreader link [ii] Outgoing Feeders: [a] For water-cooled chillers: 100 A,16 kA, FP MCCB,415 V Fixed thermal and magnetic setting, Ics=Icu with spreader link-04 Nos (2W+1S+1 spare) [b] For Hot Water Generator : 100 A,16 kA, FP MCCB,415 V Fixed thermal and magnetic setting, Ics=Icu with spreader link-02 Nos (01Working+1 SB) [c] For AHU 40 A,10 kA ,FP MCCB, 415 V,Fixed thermal and magnetic setting, Ics=Icu with spreader link-02Nos [d] For cooling towers: 16 A, 10 kA,230 V,SPN MCB-04 Nos (2 Working + 1 Standby) [e] For chilled/condenser water/hot water pump: 10 A,10 kA ,FP MCB, 415 V - 08Nos
Supplying, hoisting and fixing PVC expansion tank of capacity 500 lr duly insulated with 50 mm thick expanded polystyrene of density 20 kg/cum and finished with GI chicken wire mesh and two coats of sand cement plaster suitably 2 coats painted wicomplete with inlet, outlet, drain and over flow connections with valves , float valves of liters capacity
Outsourcing services for operation of AC plant 75 TR and DG set 250 KVA round the clock with one operator (SKILLED) in shift of 8 hours (3 shifts in a day) 24x7 including Saturday, Sunday and holiday at EEC bay bldg at AF stn Gorakhpur alongwith comprising of the following eqiupments :- (a) Chiller plant of of capacity 2 x37.5 TR working and 01 x 50 TR standby. (b) Chilled water / condenser water circulating pumps with electric motor - 06 Nos (c) HOT water generator - 37 KW (d) Hot water pump set (One working + one standby) (e) Air Handling unit - 02No (f) Humidifier (g) Cooling Tower ( 2 working and 01 standby) alongwith sprinkelers pumps and tower pump set. (h) LT control pump comprising of starters of all connected equipments - 04No (j) DG set 250 KVA with AMF panel and LT panel - 01 set. NOTE :- (i) The employement of man powers for outsourcing staff shall be placed for not more than eleven months each. (ii) The Contractor shall maintain adequate temperature and relative humidity 23+2 and 60+ 10 % as per design perimeter of each AC plant. (iii) General cleaning of complete AC plant, premetallic filters, cooling towers and surrounding area is the contractors responsibility. (iv) Daily routine checking of electric connections of all components, refrigerent, gas leaking etc, if any. If any major repair / breakdown same shall be brought to the notice og JE (E/M) and Engineer-in-Charge. (iv) All opertator should be ITI holder with 02 years experience in the operation of AC plant. (v) FOL and lubericants shall be issued by the department from the store yard of AGE (E/M) store yard. It will be the contractor's responsibility for filling of oil / lubericant in tghe fuel tank of DG set.
(vi) Empty containers shall be refunded by the contractor to the MES strore at Gorakhpur. (vii) All operator shall wear proper uniform as approved by the GE. (viii) Contractor will deploy additional man power for rest / releave. (ix) For penal recobvery on account of non operation of installation / absent of operators from duty etc the recovery @ double of minimum wages rates as publisehed by the Govt shall be applicable. (x) Proper handing / taking over of operator to be done on shift rotation and operator should not leave the plant till arrival of next operator. (xi) Stationary for maintenance of records and documentation shall be the contractor's responsibility (Daily Log sheet, Attendance register, Wages regsiter, consumption of fuel etc) (xii) Insurance of all operators shall be the contractor's responsibilty. (xiii) Contractor shall submit the nominal roll of persons to be employesd alongwith qualification / experience certificate, police verification, Identification certificate to the Engineer-in-Charge before the commencement of plant operation. (xiv) It will the contractor's responsibility to operate the DG set and plants for proper functioning of AC plant . At the time of power failure and to maintain the system functional as per the users requirements. (xv) The payment to the persons empleyed for manning shall be done only in the Aadhar Link Bank Account. (xvi) Contractor shall also provide portable fire extinguisher of required capacity and qty at installation. (xvii) Contractor shall arrange training of one month for operation and maintenance to MES tradesman as directed by the GE.
Supplying, hoistingh and fixing HDPE with inlet, outlet, drain and over flow connections with valves , float valves of 2x 5000 liters capacity , ISI marked duly connected to each other to be installed on suitable RCC/ brick staging of 4 m height
RAVINDRA SALES
M/s R.V. Constructions
M/S Rajeev Construction
M/s Kohli Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .