GE E/M RR HOSPITAL
GE E/M RR HOSPITAL DELHI CANTT, RAO TULA RAM MARG DELHI CANTT-10
CA No GE/H-08/2022-23 PROVN OF 2 X 30 KVA POWER BACKUP FOR NEW ADMISSION WARD AT AH RR UNDER GE EM RR HOSPITAL DELHI CANTT 10
2022_MES_536415_1
GE/H-08/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
GE E/M RR HOSPITAL DELHI CANTT
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE E/M RR HOSPITAL
₹37,400
Yes
17 Sept 2022
7 Jul 2022
11 Aug 2022
7 Jul 2022
9 Aug 2022
26 Jul 2022
Amount
Material and labour in replacement of Sub main wiring with 4 run of 16 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in and including cutting and chasing,and also PVC conduit suitable dia as per SSR part-I with medium grade including 16 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB complete all as directed. Note : 1. The 5 run of 16 Sqmm wire and one run of PVC conduit will be measured as one unit.
Supply and fixing of MCB 'C' curve type, 10 kA, 63 Amp, SPN, 10 KA with over load and short circuit protection complete all as specified and directed.
Supply and fix four pole MCCB 100 Amp bracking capacity 25 KA complete all as specified and directed.
S&F in replacement MCCB Incomer distribution board double door vertical type made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating, TPN 6 way, 415 volts with copper bus bar rating 250 Amps for each phase, dust and vermin proof and IP 43, IK-09 protection for provision of MCCB, MCBs as required at site including necessary cutting chasing and making good the disturbed surfaces complete all as specified and directed.
MRITUNJYA ASSOCIATES
Accurate Engineers
LABOTEK
ACR ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .