Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 CrAccepted-AOC NO157 14 13TH B MAIN ROAD 1ST STAGE 1ST PHASE GOKULA BANGALORE 560054 | BENGALURU URBAN | KARNATAKA | 560054 | ₹2.3 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹2.4 Cr+₹3.6 L (1.55%)Rejected-Finance | ₹2.4 Cr+₹3.6 L (1.55%) | L2 | Rejected-Finance Being not L1 |
| 3 | L3₹2.4 Cr+₹6.0 L (2.58%)Rejected-Finance | ₹2.4 Cr+₹6.0 L (2.58%) | L3 | Rejected-Finance Being L1 |
| 4 | L4₹2.4 Cr+₹12.3 L (5.31%)Rejected-Finance | ₹2.4 Cr+₹12.3 L (5.31%) | L4 | Rejected-Finance Being not L1 |
Tender Value
₹2.4 Cr
EMD Value
₹3.2 L
Closing Date
25 Apr 2024, 6:00 pmClosed
Neeraj Mehrotra, IDSE, CWE
Commander Works Engineers AF South Gangamma Circle Opp Guard Room 410 AFS Jalahalli Bangalore 560013
PROVISION OF MULTIPURPOSE HANGER AT ETI, AF STATION JALAHALLI
2024_MES_637951_2
85272/E8
Open Tender
Civil Works
Lump-sum
270 days
GE (M) (AF) Jalahalli
As per tender documents
7 documents required · 7 mandatory
₹2,000
GE (M) (AF) Jalahalli
₹3.2 L
10 May 2024
15 Mar 2024
27 Apr 2024
15 Mar 2024
25 Apr 2024
5 Apr 2024
15 Mar 2024 - 23 Mar 2024
Amount
GENERALSUMMARY Note : Schedule ‘A’ Part I (Ser No.02) to be quoted by contractor under Col 6.Schedule 'A' part II to part IX (Ser No.03 to 11) are prepriced by MES under Ser No. 2 to 5. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only.
Design, fabrication, Supply and erection of Pre Engineering building, steel structure including the followings - (a) Aluminium zinc coated profile colour coated steel sheet 0.50mm thick(Prepainted sheet) roof sheet (b) 3mm thick polycarbonate transulent sheet on gable portion and both side as shown on drawing(air tight on all edges & overlaps) (c) RCC design mix in not less tham M-25 grade (d) PCC block wall & Plastering internally & externally (e) Pre-construction Antitermite treatment (f) Air Turbo Vantilator on roof (g) Anti corrossion painting to all structural member (h) Sanitary fitting, plumbing work
Lumpsum price worked out by the contractor for “Internal Electrification” as listed in Schedule ‘A’ Part–II representing **______________% (_______________________)* above/below the lumpsum price of Rs.4,23,194.72 inserted by MES for Schedule 'A' Part-II
Lumpsum price worked out by the contractor for “Internal Water Supply” as listed in Schedule ‘A’ Part–III representing **______________% (_______________________)* above/below the lumpsum price of Rs.64,092.85 inserted by MES for Schedule 'A' Part-III
Lumpsum price worked out by the contractor for “Roads / path / Culvert ” as listed in Schedule ‘A’ Part–IV representing **______________% (_______________________)* above/below the lumpsum price of Rs.9,81,862.66. inserted by MES for Schedule 'A' Part-IV
Lumpsum price worked out by the contractor for “Area Drainage” as listed in Schedule ‘A’ Part–V representing **______________% (_______________________)* above/below the lumpsum price of Rs 6,73,815.44 inserted by MES for Schedule 'A' Part-V
Lumpsum price worked out by the contractor for “Sewage Disposal” as listed in Schedule ‘A’ Part–VI representing **______________% (_______________________)* above/below the lumpsum price of Rs.3,23,005.90 inserted by MES for Schedule 'A' Part-VI
Lumpsum price worked out by the contractor for “External Electrification” as listed in Schedule ‘A’ Part–VII representing **______________% (_______________________)* above/below the lumpsum price of Rs.2,14,669.70 inserted by MES for Schedule 'A' Part-VII
Lumpsum price worked out by the contractor for “External Water Supply” as listed in Schedule ‘A’ Part–VIII representing **______________% (_______________________)* above/below the lumpsum price of Rs.67,579.49 inserted by MES for Schedule 'A' Part-VIII
Lumpsum price worked out by the contractor for “Lightining Protection” as listed in Schedule ‘A’ Part–IX representing **______________% (_______________________)* above/below the lumpsum price of Rs 36,413.40 inserted by MES for Schedule 'A' Part-IX
Lumpsum price worked out by the contractor for “Site Clearance” as listed in Schedule ‘A’ Part–X representing **______________% (_______________________)* above/below the lumpsum price of Rs.4,21,626.20 inserted by MES for Schedule 'A' Part-X
SCHEDULE `A' PART - XI MISCELLANEOUS ITEMS - Items are not prepriced by MES and prepriced rates indicates 0.00 under column 5 signified this fact only. Bidder shall insert their rates in Green filed under Col-6.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers including connection all as specified
Supply & fix Air Circulator Inustrial type fans 230 volts single phase oscillating 600 mm sweep suitable for wall mounting including connection ,mounting clamps etc all as specified and directed
S&F MCB single pole 240 volts 5 to 32 Amps, 10 KA rupturing capacity.C series all as specified and as directed.
S&F MCB SPN 240 volts 5 to 32 Amps, 10 KA rupturing capacity.C series all as specified and as directed.
S&F MCB TP 240 volts 5 to 32 Amps, 10 KA rupturing capacity.C series all as specified and as directed.
S&F VTPN 4 way MCCB distribution box, Double door IP : 43 protection, door earthing, Isolated neutral bar, Mechanical Impact Strength IK 08, Insulated bus bar assembly Suitable for MCCBs upto 63 Amps TPN, connecting up complete all as specified and directed
S&F MCCB 16kA 63 Amps 4 pole, connecting up complete all as specified and directed
S & F LED High bay light fitting 200 watts made up of pressure diecast housing with toughened glass diffuser, with high power LEDs with option of secondary optic with IP66 protection, 110 LM/ watt and wired with copper wire connection accessories including suitable bracket/down rod & clamps with bolts & nuts complte all as specified
S&F in sheet metal enclosure outdoor type, double door made out of 2mm thick CRCA sheet duly power coated, conforming to IP>66 and fixed on angle iron frame/chanel of suitable size complete for fixing MCCB 63A four pole 16KA incuding MCCB and necessary PCC (1:3:6) foundation extending 300mm above GL and 60cm wide platformwall with all fixing arangements all as directed.
S&F in sheet metal enclosure outdoor type, double door made out of 3mm thick CRCA sheet duly power coated, conforming to IP>66 and fixed on angle iron frame/chanel of suitable size complete for on load change over switch 63 Amps 4 pole including 63 Amps 4 pole 16 KA MCCB and change over switch, necessary PCC (1:3:6) foundation extending 300mm above GL and 60cm wide platformwall with all fixing arangements all as directed.
M& L for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983 and as directed. Note :- (i) Excavated approved soil shall be ribbed by using sieve to separate composite particles etc as per IS and refiiling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is than gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness only will be considered for paymet.
M & L for Cutting, fixing and Brazing of Aluminium rod/copper bonded rod /copper strip /Aluminium strip /GI strip for continuity to each other to all as specified and directed.
Earthing complete with Galvanised iron earth plate electrode 60x60cmx6.00mm buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top dege of the plate not less than 1.5 meters below normal ground level, connected to 4mm GI wire as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in elctrical plate No 3 connected to earthing test point including excavation/ earth work in any type of strata, removal of surplus excavated material, GI pipe for watering and funnel, PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 in cover slab with GI protection pipe including testing on completion, all as specified and directed.
Earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of plate not less than 1.5 m below ground level connected to and including galvanised earth strip of size 25 x 4 mm (up or 7.5 mtr length) and GI pipe 40 mm light grade for protection of GI earth strip by means of bolts, nuts, checknuts and washers made out of galvanised iron and connected to earth test point as shown in electrical plate No. 3 of SSR Part-1-2009 and as specified or indicated and testing on completion including excavation and earth work any in type of strata available at site, PCC (1:3:6) type C-1 for earth chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B-1 reinforced with welded steel wire fabric (xpm) weight not less the (4kg/sqm) funnel with GI watering pipe of 20mm bore medium grade, wire nuts and lugs complete all as speified and directed.
Supply, installation, commis-sioning of Water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity 40/80 liters, including connection,foundation and testing all as specified and directed
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1.0 KVA including connection and testing all as specified and directed
UNITED TECHNO PROJECTS PVT LTD
SREEKRISHNACONSTRUCTIONS
SACKSON ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .