Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹15.8 L+₹1,430 (0.09%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹16.6 L+₹74,277.92 (4.69%)Rejected-Finance 306 SHIV BARI MARG PANCHVATI NAGAR BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L3 | Rejected-Finance Other than L1 |
Tender Value
₹22.6 L
EMD Value
₹45,200
Closing Date
13 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Bhisiana
Military Engineer Services, Garrison Engineer (AF), Bhisiana, Bathinda-151201
Provn of certain E/M Minor and Major Revenue Works at AF Stn Ferozepur and Bhisiana under GE (AF) Bhisiana
2021_MES_480441_1
GE/BHI-46/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Bhisiana
Please Refer Tender Documents
8 documents required · 8 mandatory
₹500
GE (AF) Bhisiana
₹45,200
Yes
27 Dec 2021
7 Oct 2021
15 Nov 2021
7 Oct 2021
13 Nov 2021
30 Oct 2021
8 Oct 2021 - 18 Oct 2021
60 days
Amount
Supply and Installation hi wall Split Units Indoor/Outdoor complete with cordless remote control unit and with inbuilt heating and cooling arrangement and digital inverter twin rotary of capacity 2 Ton.
Supply and Installation hi wall Split Units Indoor/Outdoor complete with cordless remote control unit and with inbuilt heating and cooling arrangement and digital inverter twin rotary of capacity 1.5 Ton.
Supply and Installation Inverter type Air Cooled Split Unit Air Conditioners with Cordless remote control unit and within built Air Ioniser and Plasma Filter for better Indoor Air Quality complete (Indoor and Outdoor) minimum 3 Star rated EER 3.2, Electric driven copper condenser Single Phase of Capacity 1.5 TR complete all as specified and directed.
Supply and Installation Hot and Cold Split Units Indoor/Outdoor complete with cordless remote control unit and with inbuilt heating and cooling arrangement and digital inverter twin rotary of capacity 1.5 Ton.
Supply and Fix Single Pole and Neutral Enclosure with a Two Pin and Earth Plug and Socket 240 Volt complete with one Single Pole MCB of cap 20 Amp.
Supply and Fix MCB SP 'C' Curve 6-40 Amps complete all as specified.
M&L for submain wiring with two Single Core of 6 Sqmm and one Single Core of 6 Sqmm as earth Wire with multi stranded copper conductor cable PVC (FR) insulated unsheathed cable 1100 Volts grade drawn through in Non Metalic Rigid (ISI Marked) PVC Conduit of size 25mm dia and the Conduits accessories as in Repairs complete including making good the distrubed surface to match the existing surface.
Supply and Fixing Voltage Stabilizer for Automatic Operation Single Phase Naturally Air Cooled Indoor type and designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ±2.5% and capacity 5 KVA.
Supply and Fixing Voltage Stabilizer for Automatic Operation Single Phase Naturally Air Cooled Indoor type and designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ±2.5% and capacity 4 KVA.
M&L for Autochanger 16 Amp complete 220 V all as specified and directed by Engineer-in-Charge.
M&L for submain wiring with two single core of 4 Sqmm and one single core of 2.5 Sqmm as earth wire with multi stranded copper conductor cable PVC (FR) insulated unsheathed cable 1100 volts grade drawn through in non Metalic rigid (ISI marked) PVC conduit of size 25mm dia and the conduits accessories as in repairs complete including making good the distrubed surface to match the existing surface complete all as specified.
Supply, installation, testing and commissioning of Isolation Transformer Indoor type, 50 KVA, 3 phase 433 Volts at No load in primary and secondary side, 66.67 Amp both in primary and secondary side, 50HZ, Temp rise in Oil 39 degree centigrade.
Supply, installation, testing and commissioning of Isolation Transformer Indoor type, 25 KVA, 3 phase 433 Volts at No load in HV and LV side, 66.67 Amp both in primary and secondary side, 50HZ, Temp rise in Oil 39 degree centigrade.
M&L for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 Meter below normal ground level connected to GI Strip 25x4mm as earthing lead by means of bolts, nuts, check nuts and washers of GI and GI tubing 20 mm bore light grade for earth lead protection up to main earth test point and including concrete pit in PCC (1:3:6) type C1 pre cast RCC (1:2:4) type B1 cover slab 54 x 54 x 5 cm with one handle for lifting made out of 8 mm dia MS bar, wire mesh, 20 mm bore GI tubing (LG) for watering, charcoal or coal and salt in alternate layers including excavation earth work complete all as specified and directed electrical plate No. 3 of SSR part - I. Note : Earthing Pit should be slide down.
Supply & fix 4 pole surge protection device 40 Amp. having In = 20kA & I(max) =40kA to be fixed in existing DB complete with all necessary lugs, nut, bots &washer all as specified & directed by Eng-in charge at site .
Supply and laying, connecting and testing XLPE UG cable 50 sqmm 4 core heavy duty 1100 volts armoured electric cable.
Supply, installing, testing and commissioning factory made LT feeder pillar box Outdoor type platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system all as specified and directed having bus bar installed on DMC/Epoxy insulators. The panel shall be dust and vermin proof, IP-65 class protection and made of 3.15 mm CRCA MS sheet with front opening type with double door shutter and locking arrangement (including provn of lock with 2 keys), powder coated finish (over a coat of red oxide), primer on outside and two coats of red oxide primer on inside surface with TPN aluminium bus bar of rating not less than 200 Amps including suitable foundation.
Excavation in trenches not exc. 1.5 mtr wide and not exc. 1.5 mtr depth for foundation of poles/laying of cables/stay/strut etc not exceeding 10 Sqm on plan and getting out in soft/loose soil.
Returning, filling including spreading, leveling watering and well ramming in layers not exceeding 25 cm as directed.
Removing excavated material (soil) n.exc 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point.
M&L for providing Fazilka River Sand as in sand cushioning to under ground cable including punning down of sand in layers as specified and as directed.
Supply and laying un-reinforced precast concrete cable cover class LV, type 1 flat of size 250mmx150mmx40mm.
Supply , install , testing and commissioning of servo controlled voltage stabilizer capacity 25 KvA three phase , 50 Hz , naturally oil cooled , indoor type copper wound metallic body duly powder coated with lifting hooks and filled with transformer oil upto level with following specification : Input voltage 340-480 V , Output voltage 415± 1% , sensitivity ±1% , Efficiency > 95% with digital display .
Rasvinderpalandco
M/s Luxmi Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .