| 1 | L1₹19.1 LAccepted-AOC NO 439 AHIV ADAN 11ND FLOOR 2RD STAGE INDIRA NAGAR BANGALORE 560 075 | BENGALURU URBAN | KARNATAKA | 560075 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹23.2 L+₹3.4 L (17.0%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L2 | Rejected-Finance Rejected Quoted rates are higher than L1 | |
| 3 | L3₹23.2 L+₹3.4 L (17.3%)Rejected-Finance | L3 | Rejected-Finance Rejected Quoted rates are higher than L1 | |
| 4 | L4₹24.9 L+₹5.0 L (25.5%)Rejected-Finance | L4 | Rejected-Finance Rejected Quoted rates are higher than L1 |
Tender Value
Refer Docs
EMD Value
₹48,000
Closing Date
15 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli BANGALORE 560013
REPAIRS AND MAINTENCE OF LT DISTRIBUTION SYSTEM IN TECHNICAL AREA OF AFS JALAHALLI UNDER AGE E/M WEST OF GE M AF JALAHALLI BANGALORE
2021_MES_413701_1
8539E8
Open Tender
Electrical and Maintenance Works
Item Rate
303 days
Garrison Engineer M AF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Garrison Engineer M AF Jalahalli
₹48,000
7 Jul 2021
18 Jan 2021
17 Feb 2021
18 Jan 2021
15 Feb 2021
2 Feb 2021
19 Jan 2021 - 24 Jan 2021
60 days
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5M in depth for laying cable/pole foundation/stay assembly and getting out in soft/loose soil.
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5M and not exceeding 3 meter in depth for foundation of poles and getting out in soft/loose soil
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm all as specified.
Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983 and as directed.Note :- Excavated approved soil shall be ribbed by using sieve to separate composite particles etc as per IS and refilling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is than gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness only will be considered for paymet.
All as per the Item No- 04 but except sand Note :- (i) For the purpose of payment punned thickness only will be measured.(ii) Sand Obtain from existing excavated trenches shall be reused for cable cushoining.
Removal of excavated soil to a distance not exceeding 50M and depositing at a level not exceeding 1.5 meter above starting point all as specified.
Material and labour for laying bricks 'B' class over a cable (Width wise) complete all as specified and directed.
All as per the Item No- 07 but except Bricks Note :- (i) Old serviceable bricks shall be reused for laying over a cable.
Taking up the LT Cable of size 400 Sqmm 3½ core from trenches / wall / pole, including brick and sand all specified and as directed. Note : (i) Excavation and earth work shall be paid in respective items here in before. (ii) Taking and removal of sand and bricks shall be includes in quoted rates of item and Old good condition sand & Old serviceable bricks shall be stacked properly for reuse for laying of LT UG cable at Same location or up to 200 mtr distance.ii) Old Serviceable LT cables shall be keep in safe custody for re laying under subsequante item here in after.
All as per item No 9 but LT Cable of size 240 Sqmm 3½ core
All as per item No 9 but LT Cable of size 185 Sqmm 3½ core
All as per item No 9 but LT Cable of size 120 Sqmm 3½ core
All as per item No 9 but LT Cable of size 95 Sqmm 3½ core
All as per item No 9 but LT Cable of size 70 Sqmm 3½ core
All as per item No 9 but LT Cable of size 50 Sqmm 3½ core
All as per item No 9 but LT Cable of size 35 sqmm 3½ core
All as per item No 9 but LT Cable of size 16 Sqmm 4 core
All as per item No 9 but LT Cable of size 10 Sqmm 4 core
Laying only serviceable LT Cable of size 400 Sqmm 3½ corein trenches / wall / pole Obtain from items No- 9 to 18 ) here in before of following cross sectional area all as specified and as directed. Note : i) Old good condition sand and Old serviceable bricks shall be reuse for laying of cable obtained from Items here - in - before. (ii) Excavation & earth work, new sand, new bricks for cable protection shall be measured & paid seperatly in respective items here- in- before. (iii) The cost for cleaning, visiual inspection of insulation and testing by connecting the electric countinuity deemed to included in the quated rates of item.
All as per item No 19 but LT Cable of size 240 Sqmm 3½ core
All as per item No 19 but LT Cable of size 185 Sqmm 3½ core
All as per item No 19 but LT Cable of size 120 Sqmm 3½ core
All as per item No 19 but LT Cable of size 95 Sqmm 3½ core
All as per item No 19 but LT Cable of size 70 Sqmm 3½ core
All as per item No 19 but LT Cable of size 50 Sqmm 3½ core
All as per item No 19 but LT Cable of size 35 sqmm 3½ core
All as per item No 19 but LT Cable of size 16 Sqmm 4 core
All as per item No 19 but LT Cable of size 10 Sqmm 4 core
Material and labour for XLPE insulated heavy duty electric cable LT Cable of size 400 Sq mm 3½ core with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheather laying in trenches/cable ducts, fixed to wall/pole complete all as specified and directed Note:- (i) Excavation & earth work, new sand, new bricks for cable protection shall be measured & paid seperatly in respective items here- in- before. Make of LT XLPE Cable:- Havells / Polycab /Asian Cable / Finolex Gloster
All as per item No 29 but LT Cable of size 240 Sq mm 3½ core
All as per item No 29 but LT Cable of size 185 Sq mm 3½ core
All as per item No 29 but LT Cable of size 120 Sq mm 3½ core
All as per item No 29 but LT Cable of size 95 Sq mm 3½ core
All as per item No 29 but LT Cable of size 70 Sq mm 3½ core
All as per item No 29 but LT Cable of size 50 Sq mm 3½ core
All as per item No 29 but LT Cable of size 35 sq mm 3½ core
All as per item No 29 but LT Cable of size 16 Sq mm 4 core
All as per item No 29 but LT Cable of size 10 Sq mm 4 core
Material and labour for cutting of bituminious road/ hard standing/PCC path/wall up to a size not exceeding 20cm width and not exceeding 60cm in depth for laying of protection pipe for cable including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1, 40 mm grade crushed stone aggregate upto existing surface level or removing the any type of tiles carefully and refixing properly as per existing surface complete all as specified and as directed.
Boring of holes under road, pavement, hard standing by adopting horizontal boring including supply and inserting of HDPE pipe of 80 mm dia not less than 6kg/cm working pressure confirming to IS allas specified and directed. Note: Depth will not be less than 1.00 M below the road pavement and hard standing boring shall be carried out without damaging the road and hard standing.
Material and labour for Plain cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate in foundation all as specified and as directed.
Material and labour for PCC 1:3:6 type C1 using 20 mm graded stone aggregate for stay and coping for poles including necessary form work to exposed surfaces finished smooth and even all as specified and as directed.
Supply and lay/fix along wall/pole GI tubing light grade 40 mm dia for cable protection including holding clamp wherever required made out of MS flat of size 40x5 mm complete all as specified and directed including taking down old U/S pipe.
All as per item No 43 above but of size 50 mm dia
All as per item No 43 above but of size 80 mm dia
Material and labour in repair to Pin type porcelain vitreous white brown or green insulator including one galvanized mild steel spindle two galvanized iron washers and one galvanized iron nut 50 mm height 65 mm dia for 550 volts grade complete.
Material and labour in repair to insulators porcelain vitreous white or brown or green insulators including galvanized mild steel straps 31 x 3 mm, 75 mm height and working pressure 1100 volts all as specified
Material and labour in repair to Straight through jointing kit suitable for LT UG cable of size 3½ core 25 to 50 sqmm UG cable including testing complete as specified .
Material and labour for repairs Straight through jointing kit suitable for LT UG cable of size 3½ core upto 70 sqmm to 150 sqmm UG cable including testing complete as specified .
Material and labour for repairs Straight through jointing kit suitable for LT UG cable of size 3½ core upto 185 sqmm to 400 sqmm UG cable including testing complete as specified .
Material and labour for repairs End jointing kit suitable for LT UG cable of size 3½ core 25 to 50 sqmm UG cable including testing complete as specified .
Material and labour for repairs End jointing kit suitable for LT UG cable of size 3½ core upto 70 sqmm to 150 sqmm UG cable including testing complete as specified .
Material and labour for repairs End jointing kit suitable for LT UG cable of size 3½ core upto 185 sqmm to 400 sqmm UG cable including testing complete as specified .
Servicing to LT panels/Feeder pillar boxes comprising MCCBs/change over switches metering eqpt etc. as incoming/outgoing controls including cleaning, greasing the hinges, locking arrangement, checking the serviceability of individual items, identification of the defective parts replacing the worn-out fastners, insulators, rubber door beadings, gaskets etc all as directed by Engineer-in-Charge. Note :- (i) Unserviceable parts replaced if any shall be measured & paid separately under respective items. (ii) Cleaning of LT panel surrounding area by mean surface excavation not exe 30cm deep and average 15cm deep and removing the grass weeds debris and including removal of soil to the distance not exe 50M getting out and leveling neatly the excavated area. (iii) The quoted rates deemed to included for all above
Removing the existing hinges by cutting and supply and fixing of new hinges all as per existing size
Painting of LT panel board/feeder pillar boxes with two coats of synthetic enamel spray paints over a coat of red oxide primer matching existing colour after scrapping the old paint by means of emery paper and cleaning with thinner including necessary markings/sign writing etc all as directed by Engr-in-charge.
Rewiring the LT cubical type panel by means of PVC insulated multi strandard copper wire of existing size including replacing unserviceable connectors, fastners etc,. etc after taking out the old unserviceable wiring all as directed.
Supply only LED indication Lamps for R,Y,B Phase
Supply only MCB SP 6 to 32A with bracking capacity 10KA
Supply only digital Power Factor meter any range 1A/5A and 110/230V with built in transducer Accuracy class ±20
Supply only Indoor resin cast ring type low tension current transformer 50/5A to 75/5A 15VA burden accuracy class 1 confirming to IS 2705 /1992
Supply only Indoor resin cast ring type low tension current transformer 100/5A to 300/5A 15VA burden accuracy class 1 confirming to IS 2705 /1992
Supply and replace in repair - Surge protection 4 pole having surge protection level max 15KA upto 1.2KV type II. in to LT panel boards / feeder pillar boxes/DBs including disconnecting and removing existing defective item from electric circuit including necessary connected fastners, burnt cables, accessories etc all as per site requirement/existing make/model.
All as per Sl item No. 66 here in before but of busbar box of capacity 250 amps and incoming MCCB of capacity 160 amps 04 pole, 415 volts thermal magnatic type with braeking capacity 25 KA.
Earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of plate not less than 1.5 m below ground level connected to and including galvanised earth strip of size 25x4 mm (up or 7.5 mtr length) and GI pipe 40 mm light grade for protection of GI earth strip by means of bolts, nuts, checknuts and washers made out of galvanised iron and connected to earth test point as shown in electrical plate No. 3 of SSR Part-1-2009 and as specified or indicated and testing on completion including excavation and earth work any in type of strata available at site, PCC (1:3:6) type C-1 for earth chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B-1 reinforced with welded steel wire fabric (xpm) weight not less the (4kg/sqm) funnel with GI watering pipe of 20 mm bore medium grade, wire nuts and lugs including taking down old u/s one complete all as specified and as directed.
Earthing complete with copper earth plate electrode of size 600 x 600 x 3.15 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of plate not less than 1.5 m below ground level connected to and including copper earth strip of size 20x3 mm (up or 7.5 mtr length) and GI pipe 40 mm light grade for protection of GI earth strip by means of bolts, nuts, checknuts and washers made out of galvanised iron and connected to earth test point as shown in electrical plate No.3 of SSR Part-1-2009 and as specified or indicated and testing on completion including excavation and earth work any in type of strata available at site, PCC (1:3:6) type C-1 for earth chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B-1 reinforced with welded steel wire fabric (xpm) weight not less the (4kg/sqm) funnel with GI watering pipe of 20mm bore medium grade, wire nuts and lugs including taking down old u/s one complete all as specified and as directed.
Material and labour for Aluminium earth strip of size 25 x 3 mm in ground not exceeding 40 cm deep / fixing to wall / structure including taking down old strip complete all as specified and as directed.
Material and labour for Copper earth strip of size 32 x 6 mm in ground not exceeding 40cm deep / fixing to wall / structure including taking down old strip complete all as specified and as directed.
Material and labour for GI earth strip of size 25 x4 mm in ground not exceeding 40cm deep / fixing to wall / structure including taking down old strip complete all as specified and as directed.
Material and labour for Painting of steel tubular pole any type/size, by applying two coat of aluminium paint after scraping / brushing and cleaning the rust on pole and cross arms. Aluminium painting will be done on pole above 1.5 metre height from ground level and balance 1.5 mtr from ground level will be painted by alternate layer of black and white enameled paint (30 Cms each). Pole Nos will be written on pole by black paint in yellow circle of 150mm dia, complete, all as specified and directed.
Cutting/trimming of tree branches of any size resting/interrupting the LT over head line any number of conductors span length between 45 to 50 M cutting clearing 2 m all around the conductor and removing the tree branches from site all as directed
Cutting and cleaning of fallen down trees and branches of any size from the LT over head lines by providing required machinary/cutting eqpts and disposing to a distance not less than 50 meters and restoring electric supply including jointing the damaged conductors all as directed.
Supply and fix in repair the MCCB of capacity 25 A to 32 A, 415 Volts 4 pole with brecking capacity 16KA - in LT panel boards / feeder pillar boxes including disconnecting and removing existing from electric connection including necessary connected fastners, burnt cables, accessories like spreader ,cages etc all as per site requirement/existing make/model,all as specifed and as directed.
All as per item No 76 above but of capacity 40A - 50A 415 Volts 4 pole with breacking capacity 16 KA
All as per item No 76 above but of size 63A-80A 415 Volts 4 pole with breacking capacity 16 KA
All as per item No 76above but of size 80-100A 415 Volts 4 pole with breacking capacity 16 KA
All as per item No 76 above but of size 100-125A 415 Volts 4 pole with breacking capacity 16 KA
All as per item No 76 above but of size 160-200A 415 Volts 4 pole with breacking capacity 16 KA
All as per item No 76 above but of size 250 A, 415 Volts 4 pole with breacking capacity 36 KA
All as per item No 76 above but of size 400 A 415 Volts 4 pole with breacking capacity 36KA
Supply and fix in repair the MCCB of capacity 25 A to 32 A, 415 Volts 3 pole with breacking capacity 16KA in Exisitng LT panel boards / feeder pillar boxes including disconnecting and removing existing from electric connection including necessary connected fastners, burnt cables, accessories like spreader ,cages etc all as per site requirement/existing make/model,all as specifed and as directed.
All as per item No 84 above but of size 40A - 50A 415 Volts 3 pole with breacking capacity 16 KA
All as per item No 84 above but of size 100-125A 415 Volts 3 pole with breacking capacity 25 KA
All as per item No 84 above but of size 160-200A 415 Volts 3 pole with breacking capacity 25KA
All as per item No 84 above but of size 250A, 415 Volts 3 pole with breacking capacity 36KA
Material and labour for Insulated Busbar Enclosure made of Powder Coated CRCA 2mm thick of size 300x300x25 CM depth with single double door, including provision of opening for cable entry duly painted with two coats of synthetic enamel paint over one coat of red oxide and suitable fixing MS clamps 40x5 mm thick bend to shape drilled with holes suitable for fixing to PCC / Steel tubular pole/wall suitable for mounting of MCCB 3/4 Pole complete all as specified and directed by Engr -in -charge.
Material and labour for cutting out the burnt out existing cable and reconnecting by providing new lugs,tapes etc for cable upto 50 Sqmm 3.5 core complete all as specified and directed by Engr-in-charge.Note - Excavation work for use to loop of existing cable shall be includes in quated rates.
All as per item No 90 above but for cable of size 70 Sqmm to 120 Sqmm.
Taking down old unserviceable PCC/steel tubular pole of any type and size from existing location including excavation, earth work and PCC work for embedding pole complete all as directed.
Supplying, transporting, errecting and fixing steel tubular swaged welded pole of over all height 9.00 m long complete type 410-SP-31 conforming to IS-2713 (Part I to III 1998 with cast iron base plate, finial tapper plug cap, bolt, nut and washer etc., complete all as specified and directed by Engr-in-charge. Note (i) Excavation, earth work and PCC work for embedding pole shall be measured and paid seperately. (ii) Pole upto 1.5 m top of copping shall be painted with 2 coats of block and white strips alternate 30cm each over one coat of red oxide primer (iii) Steel tubular pole above 1.5 m shall be painted with 2 coats of alu paint over a coat of red oxide primer the rate for above items shall be deemed to be inclusive in the quoted rate.
Dismantling steel tubular pole by cutting ,breaking of PCC of existing steel tubular poles any type/any length and taking up carefully for reuse,shifting from one location to other location upto distance a 500M and provide the Base base plate of size 300mmX300mm made of MIld steel of 10 mm thick dully welded to base of steel pole complete all as specified and directed by Engr-in-charge. Note :- Excavation, earth work and PCC work for embedding pole shall be measured and paid seperately in respective items. (iii) Existing pole upto 1.5 m from top of copping shall be painted with 2 coats of black and white strips alternate 30 cm each over one coat of red oxide primer (iv) Steel tubular pole above 1.5 m shall be painted with 2 coats of aluminium paint over a coat of red oxide primer and the rate for above items shall be deemed to be inclusive in the quoted rate. (v) The quoted rate shall be deemed to be included for cutting the rusted/ broken portion of pole.
Material and labour in replacement of cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nut, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or as size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint.
Servicing,/Repair and maintenance to Solar Street light including replacement of circuit wiring cleaning of sloar volatic panel ,dismanting of panel circuit board ,taking down battery any capacity and taking down of LED street light any capacity complete all as specified and directed by Engr-in-charge. Note - The unserviceable parts replaced if any (except circuit wiring) shall be Measured & paid separately under respective items here in-after.
Supply only the battery minimum rating Lead Acid, tubular positive plate flooded electrolyte or Gel or VRLA type of 12V, 75 Ah (at C/10 discharge rate).Tubular solar battery of 12Volts 75 AH in an IP 65 enclosure.will have a
Supply only the LED street light lumnaire with 25 lux out put spread around the pole suitable for Solar panel.
Supply only the solar photovoltaic module Panel. Note - Panel to be fixed firmly on top of the pole with suitable tilt and inclination so as to receive maximum sunlight throughout the day.
Supply only the charge controller protects circuit board as per existing.
Supply only the electrolyte for existing battery and top at site testing complete.
devan enterprises
eurekaenterprises
C R R CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .