Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance U 57 OPP AGGARWAL NURSING HOME RAJU GAS AGENCY OFFICE VIJAY NAGAR NARELA DELHI DELHI 110040 | NORTH | DELHI | 110040 | Admitted-Finance |
| 2 | Admitted-Finance 1 3104 KUNJ GALI RAM NAGAR EXTN LONI ROAD SHAHDARA DELHI 32 | SHAHDARA | DELHI | 110032 | Admitted-Finance |
| 3 | Admitted-Finance D 981 ASHOK NAGAR GALI NO 12 SHAHDARA DELHI 32 | SHAHDARA | DELHI | 110031 | Admitted-Finance |
Tender Value
₹4.6 L
Closing Date
25 Mar 2021, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Atul Bhardwaj
SOUTH DELHI MUNICIPAL CORPORATION OFFICE OF THE EX. ENGINEER (ELECT.)-WZ OLD ZONAL BUILDING, Ist FLOOR, VISHAL ENCLAVE RAJOURI GARDEN, NEW DELHI-110027
Provision of Lighting arrangement in park opp. E-350 Madi pur and opp. H.No. B-248 Paschim Vihar Extn. Mahila Park near Police Chowki in Ward no. 01-S Madipur under West zone.
2021_SDMC_73924_2
EE/Elect/WestZone/2020-21/23
Open Tender
Electrical Works
Works
30 days
Rajouri Garden
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Commissioner SDMC
Exempted
26 Mar 2021
20 Mar 2021
26 Mar 2021
20 Mar 2021
25 Mar 2021
20 Mar 2021
150 days
Amount
SITC of 8 to 10 W LED cone type Bollard Light made of pressure die cast powder coated housing with Polycarbonate Diffuser, high efficiency long life, Surge Voltage, Over Voltage protection, Open Circuit, Short Circuit protection and other safety test as per IS 15885 part 2 etc. as required.
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C”curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole and neutral
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt) as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Providing and laying earth connection from earth electrodewith 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing of following size PVC insulated and PVC Sheathed copper conductor 3-core submersible cable confirming to IS 694/1990 etc. As required.(a) 3x2.5 sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Supply of XLPE insulated,PVC sheathed Al.conductor Armoured Cable 1.1 KV grade Conforming to IS 7098 of following Sizes
2 x 6 sq mm
2x10sq.mm
Suppliying and Fixing of Piller box size 900mmx450mmx250mm suitable for mounting incomer of 250 A MCC/Main Switch 4 pole and energy meter 3 phase comkplete with eleythopic grade Al bus bar of size 25mm x10mm mounted on galvanized M.S body powder coated pilferage proof SMC door duly weided with SS with ran com size 40mm x40mmx 5mm, 600mmheight in cutting 300mm height blow and covered with shade proof SMC sheet of 3mm as required
Fabrication, supply & erection of following size flange mounted hot dip galvanized octagonal pole made from HT steel plate, window with flash cover with full verticle window cover at appropriate height from the base plate on existing cement concrete pedestal as required. i/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. GI strips 4 mm thick of suitable length and having suitable size tapped holes as reqd, terminal block suitable for 25 sq mm conductor – 4 nos. & shorting links on DIN channel i/c pdg and fixing DIN channel of suitable length,, 6 Amp. SPMCB ‘C’ characteristics, earth stud, cable support clamp suitable for 4x25 sqmm cable.Logo/name of manufacturer shall beonbosseds on the pole Galvanization as per relavant IS
5.0 mtr height, 3 mm thick, bottom dia of 130mm & top dia of 70mm base plate of size 225 x 225 x 12 mm thick
Providing and laying in position M25 grade reinforced cement concrete foundation of size 450 mm(L) x 450 mm wide and 1000 mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia -960mm long (approx.) - 8 nos. and reinforcement of cold twisted bar of 8 mm dia - 1400 mm (approx.) - 6 nos. (with 150 mm spacing) as required with supplying and positioning of 4 nos foundation bolts size 16 mm dia & 600mm long. J type i/c 2 nos. template anchor plates of size 225mmx225mmx3mm providing DWC HDPE for cable entry and exit as required for 3 mand 5mtr pole.
Fabrication supplyiing and fixing Galvanised single overhang arm bracket made out of 250 mm long galvanized top tube with cap & 1000mm long 32 mm dia galvanized pipe with tightening bolts complete as reqd
Fabrication, supplying, installation, testing and commissioning of 12Mtr High Mast Systam with its accessories Mast shaft shall be in one section, hot dip galvanised 4mm thick (single dip) inside and outside and suitable for wind velocity as per IS 875 Part 3. There shall be only logitudinal seam weld per section and No circumferential weld. it should also include accessories for High Mast i/c head frame,2 point suspension system with steel wire rope 5mm dia (7/19 construction ) single drum wich, galvanized lantern carrige arrangment suitable for 4/6 Nos Flood Light luminaries asymmetrically and its control gear boxes and lighting finial. the Mast shall have integaral type manual tool mounted at the base compartment of its rasing and lowering operation with foundation bolts and anchor plate and control panel housing suitable RCC(1:2:4: ) shallow foundation of size 1m(L)x1m wide and 2m deep i/c excavation of earh , providing cutting, bending and placing in position reinfircement of cold twisted bar of 12mm dia-2100mm long (approx) -16 nos. and reinforcement of cold twisted bar of 8mm dia -3700mm (approx)-13nos. (with 150 mm spacing) as required with positioning of foundation bolts and providing DWC HDPE pipe for cable entry & exit as required foe the high mast conjsidering the safe soil bearing capcity at site as 10T/sqm at 2mts. Depth with all material i/c 4 nos S.P MCB 63 Amp DP Isolator etc as required Logo/Name of manufactirer shall be embossed on the pol, Galvanization as per relevant IS.
DELIGHT TRADING COMPANY
SANGWAN ELECTRICALS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .