| Sl No | Description | Qty | Unit | SUPERCOOL ENGINEERING SERVICES L4 | Iceberg HVAC Pvt Ltd L3 | BRITE INDUSTRIES L2 | maxcool solutions pvt ltd L1 | TEMPCON ELECTROMECH SYSTEMS L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00Split Air-conditioner: Supply, installation, testing and commisioning (SITC) of wall mounted 5 star rated Invertor hi-wall Split AC units/ ceiling suspended ceiling concealed split AC units of follwing nominal cooling capacities(Minimum) as per technical specifications and instructions of Engineer-in-Charge. Note: 1.The outdoor unit shall be provided with 10 mm thick neoprene pads. 2.The price is inclusive of consumables, leak testing, refrigent gas that may be required to put the air conditioner into service and no extra payment shall be made for the same. 3.The cutout for regrigerant pipe cable and drain shall be included in scope and no extra payment shall be made for the same. 4.The ODU dimension shall be suitably selected for mounting in the space available in the parapet(approaximately 1000 mm width and 800 mm depth) without compromising on the condensor cooling and rated cooling capacity of the indoor unit as well as servicability. 5. On site warranty of Compresser shall be min. 10 years and PCB shall be min. 5 year from date of supply of units. Warranty certificates shall be submitted for each units while supplying the units. 6. Anti corrosive coating shall be done for fins of ODU at works of OEM | ||||||||
| 1.10 | 1.8 TR capacity Hi-Wall Split AC | 48 | Each | 72,000 ₹34,56,000 | 72,800 ₹34,94,400 | 70,800 ₹33,98,400 | 64,826 ₹31,11,648 Lowest | 1,00,400 ₹48,19,200 |
| 1.20 | 1.5 TR capacity Hi-Wall Split AC | 64 | Each | 55,000 ₹35,20,000 | 55,550 ₹35,55,200 | 62,400 ₹39,93,600 | 51,255 ₹32,80,320 Lowest | 76,400 ₹48,89,600 |
| 1.30 | 1.0 TR capacity Hi-Wall Split AC | 5 | Each | 45,000 ₹2,25,000 Lowest | 48,100 ₹2,40,500 | 49,500 ₹2,47,500 | 46,730 ₹2,33,650 | 66,000 ₹3,30,000 |
| 1.40 | 1.5 TR capacity Ducted Split AC (With ductpiece work of approx. 1 sq.m and grills of approax. 0.6 sq.m.) | 6 | Each | 65,500 ₹3,93,000 Lowest | 1,12,700 ₹6,76,200 | 85,800 ₹5,14,800 | 88,340.17 ₹5,30,041.02 | 86,600 ₹5,19,600 |
| 2.00 | Refrigerant Piping with Nitrile Rubber insulation (Combined Suction line & Discharge line): Supply, installation, testing and commissioning of Interconnecting refrigerant copper piping ( suction & discharge line) of suitable sizes for above split AC units duly insulated with closed cell tubular elastomeric nitrile rubber of minimum density not less than 33kg/cum of thickness 13 mm thick for size upto 19.05 mm dia. pipe and 19 mm thick for sizes above 19.05 dia pipes as per technical specifications, manufacturer's recommendations and instructions of Engineer-in-Charge.
Note:
Scope of work also includes the following:
i) coating of the copper ppies with transparent anti corrosive primer before insulation.
ii) The insulation shall be mechanically protected with a coat of polyshield of approved colour (starbond 30-36 or equivalent) of minimum 5 mil thickness. | 620 | RM | 950 ₹5,89,000 | 1,350 ₹8,37,000 | 1,150 ₹7,13,000 | 850 ₹5,27,000 Lowest | 1,100 ₹6,82,000 |
| 3.00 | Drain piping duly insulated: Supply, installation and commissioning of 25mm dia. rigid / flexible HD PVC piping duly insulated with closed cell elastomeric rubber insulation as per technical specifications and instructions of Engineer-in-Charge. | 620 | RM | 220 ₹1,36,400 | 200 ₹1,24,000 | 650 ₹4,03,000 | 149 ₹92,380 | 125 ₹77,500 Lowest |
| 4.00Cabling: Supply & laying of following sizes of flexible copper power/control cabling to connect outdoor units with respective indoor units / power cable to connect power outlet to ODU/ IDU complete with end connections with suitable copper lugs as required all as per technical specification and instructions of Engineer-in-Charge. | ||||||||
| 4.10 | 3C X 4 sq.mm | 620 | RM | 225 ₹1,39,500 | 285 ₹1,76,700 | 200 ₹1,24,000 Lowest | 284 ₹1,76,080 | 415 ₹2,57,300 |
| 4.20 | 4C X 2.5 sq.mm | 750 | RM | 250 ₹1,87,500 | 220 ₹1,65,000 | 150 ₹1,12,500 Lowest | 255 ₹1,91,250 | 365 ₹2,73,750 |
Tender Value
₹1.4 Cr
EMD Value
₹1.7 L
Closing Date
30 Jan 2024, 5:00 pmClosed
Cheif Engineer (ESG)
3rd Floor, V.S. Bhavan, Anushaktinagar, Mumbai - 400094.
Modification of electrical and mechanical installations including air conditioning work at various offices under DCSEM in V.S.Bhavan extension and replacement of old air conditioners at various offices under DCSEM Mumbai.
2024_DCSEM_790235_1
DCSEM/CQD/QSC/ VSB-Extn-AC/NIT/34/23-24 12.01.24
Open Tender
Job Works
Works
180 days
Anushaktinagar, Mumbai
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹1.7 L
6 Feb 2024
15 Jan 2024
1 Feb 2024
15 Jan 2024
30 Jan 2024
15 Jan 2024
15 Jan 2024 - 25 Jan 2024
Amount
1.8 TR capacity Hi-Wall Split AC
1.5 TR capacity Hi-Wall Split AC
1.0 TR capacity Hi-Wall Split AC
1.5 TR capacity Ducted Split AC (With ductpiece work of approx. 1 sq.m and grills of approax. 0.6 sq.m.)
Refrigerant Piping with Nitrile Rubber insulation (Combined Suction line & Discharge line): Supply, installation, testing and commissioning of Interconnecting refrigerant copper piping ( suction & discharge line) of suitable sizes for above split AC units duly insulated with closed cell tubular elastomeric nitrile rubber of minimum density not less than 33kg/cum of thickness 13 mm thick for size upto 19.05 mm dia. pipe and 19 mm thick for sizes above 19.05 dia pipes as per technical specifications, manufacturer's recommendations and instructions of Engineer-in-Charge. Note: Scope of work also includes the following: i) coating of the copper ppies with transparent anti corrosive primer before insulation. ii) The insulation shall be mechanically protected with a coat of polyshield of approved colour (starbond 30-36 or equivalent) of minimum 5 mil thickness.
Drain piping duly insulated: Supply, installation and commissioning of 25mm dia. rigid / flexible HD PVC piping duly insulated with closed cell elastomeric rubber insulation as per technical specifications and instructions of Engineer-in-Charge.
Cabling: Supply & laying of following sizes of flexible copper power/control cabling to connect outdoor units with respective indoor units / power cable to connect power outlet to ODU/ IDU complete with end connections with suitable copper lugs as required all as per technical specification and instructions of Engineer-in-Charge.
3C X 4 sq.mm
4C X 2.5 sq.mm
PVC Truncking: Supply & laying of casing and caping (PVC trunking 100 mm (Width) X 50 mm(Depth)) for enclosing refrigerant tubing with insulation, drain line and electrical cable as per technical specifications and instructions of Engineer-in-Charge.
M.S. supports: Supply, fabrication & installation of M.S. stand for the ODU (outdoor unit) of AC unit as required fabricated out of M.S. flat of size (50 mm x 8 mm) and M.S. angle of size (50 mm x 50 mm x 8 mm) and safety guard of M.S. flat of size (12 mm x 12 mm) with suitablle opening for maintenance purpose of ODU unit, painting with two coats of synthetic enamel paint over one coat of red oxide primer of approved make & shade to all M.S. parts at all levels & elevations as required and as per technical specification and instructions of Engineer-in-Charge.
Dismantling and safe removal of Air conditioners
Dismantalling and safe removing the old existing wall mounted air conditioner including pumpdown of refrigerant in the system,safely removal its copper piping & M.S. stand and packing of existing piping holes etc. depositing old AC at DCSEM stores, complete with all as per requirement and instructed by EIC.
Dismantalling and safe removing the old existing window air conditioner including safely removal and packing of existing piping holes etc. depositing old AC at DCSEM stores, complete with all as per requirement and instructed by EIC.
Supply, installation testing & commissioning of 2 nos 2.5 sq.mm & 1 no. 1.5 sq.mm Cu. Conductor flexible PVC insulated multi stranded wires in existing concealed / surface conduit including end termination with Cu. Lugs ferrule numbers on both sides, etc. all as required & instructed by the E-I-C. Note : PVC sleeves shall be provided for crossing the wall, drilling holes & its refinishing to be also included in the scope.
Supply installation testing & commissioning of 25 x 16 mm casing capping on surface of slab / wall / column fixed with nylon / rawal plug, GI wood screws at the intervals of 300mm includes providing the tags for wires inside casing capping for bunching to avoid hanging of wires at the intervals of 600mm as per the instruction of Engineer-in-charge.
Supply installation testing & commissioning of 25 dia rigid HMS PVC of conduit with all required accessories like junction box , bend, etc. on surface of slab / wall / column fixed with PVC spacer saddles , nylon / rawal plug, GI wood screws at the intervals of 300mm as per the instruction of Engineer-in-charge.
Supply installation testing & commissioning of 25 mm dia FRPP flexible conduit with PVC gland on surface of slab / wall / column fixed with PVC spacer saddles, nylon / rawal plug, GI wood screws as per the instruction of Engineer-in-charge.
Making of grooves by cutting the floor tiles /floor/wall with cutter machine and supply & laying HMS PVC of 25 dia rigid conduit with all required accessories line round junction box , bend, etc. for laying power & control cable/ wires as required, refilling the grooves with cement concrete & finishing the surface to floor level as required. Note: Required painting matching with existing walls colour by applying two coats of premium acrylic emulsion paint is included in the scope of work without extra cost to the department
BRITE INDUSTRIES
Iceberg HVAC Pvt Ltd
SUPERCOOL ENGINEERING SERVICES
TEMPCON ELECTROMECH SYSTEMS
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.88 MB
DetailedNITVSBExtnAC.pdf
Tender Documents • 0.87 MB
TechBidSGF_VSBExtnAC.pdf
Tender Documents • 1.52 MB
Techdatasheet_VSBExtnAC.xls
Tender Documents • 0.09 MB
BOQ_830605.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .