Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.1 CrAdmitted-Finance | ₹4.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹4.5 Cr+₹34.8 L (8.46%)Admitted-Finance 9 KRISHNA VIHAR NEAR CHUNGI NAKA NANTA ROAD KUNHADI KOTA 324008 | KOTA | KOTA | RAJASTHAN | 324008 | ₹4.5 Cr+₹34.8 L (8.46%) | L2 | Admitted-Finance |
| 3 | L3₹4.7 Cr+₹55.4 L (13.5%)Admitted-Finance | ₹4.7 Cr+₹55.4 L (13.5%) | L3 | Admitted-Finance |
| 4 | L4₹4.9 Cr+₹77.5 L (18.8%)Admitted-Finance KHASRA NO 265 281 288 VILL PARSAUN DASNA P O JINDAL NAGAR DISTT HAPUR UP 201015 | HAPUR | HAPUR | UTTAR PRADESH | 201015 | ₹4.9 Cr+₹77.5 L (18.8%) | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SALASAR TECHNO ENGINEERING LIMITED L4 | Navdurga ElectroConstruction Pvt. Ltd. L1 | KAY CEE ENERGY & INFRA LIMITED L2 | SJV Infra Projects Private Limited L3 |
|---|---|---|---|---|---|---|---|
| 1.00Main Material/Items | |||||||
| 2.00Tubular Monopoles | |||||||
| 3.00 | 220kV D/C transmission Poles(AP1/AP2 Type) (bottom cross arm 32M) | 2 | Nos. | 1,22,26,067.92 ₹2,44,52,135.84 | 1,07,03,187.64 ₹2,14,06,375.28 Lowest | 1,18,56,097.2 ₹2,37,12,194.4 | 1,17,14,490 ₹2,34,28,980 |
| 4.00Overhead Line Material | |||||||
| 5.00Tower & Stub | |||||||
| 6.00 | High Tensile Steel | 22.8 | MT | 1,40,889.16 ₹32,11,991.07 | 1,12,302.96 ₹25,60,282.88 Lowest | 1,31,139.3 ₹29,89,713.76 | 1,23,509 ₹28,15,758.18 |
| 7.00 | Mild Steel | 9.95 | MT | 1,34,180.16 ₹13,35,495.13 | 1,20,324.6 ₹11,97,590.74 | 1,37,298.9 ₹13,66,535.95 | 1,18,730 ₹11,81,719.69 Lowest |
| 8.00 | Assorted Size G. I. Bolts and Nuts (ISI Marked), STEP BOLT and SPRING WASHER (ELECTRO-GALVANISED) | 1.67 | MT | 1,67,725.2 ₹2,80,101.08 | 1,22,998.48 ₹2,05,407.46 Lowest | 1,48,662.3 ₹2,48,266.04 | 1,69,550 ₹2,83,148.5 |
| 9.00Conductor | |||||||
| 10.00 | ACSR Zebra Conductor (54/3.18 MM AL+7/3.18MM STEEL) | 6 | KM. | 5,95,424.46 ₹35,72,546.76 | 4,96,004.74 ₹29,76,028.44 | 5,14,050.48 ₹30,84,302.88 | 4,36,488.24 ₹26,18,929.44 Lowest |
Tender Value
₹5.5 Cr
EMD Value
₹11.1 L
Closing Date
13 Nov 2024, 4:00 pmClosed
SE (AUTOMATION, N/M, SP)
VIDYUT BHAWAN, JYOTI NAGAR, JAIPUR
Raising /shifting work of 22KV S/C (on D/C Towers) Bharatpur- Agra Tr. Line (Loc. No. 50-51) (Approx. Length-2.0Kms) at crossing across proposed Railway Track in Kitham- Bhandai Under deposit work of Railways (Approx Length-2.0Kms) Under deposit work
2024_RRVPN_415533_1
RVPN/EHV/ASP/TN-122
Open Tender
Electrical Works
Turn-key
270 days
BHARATPUR
Please refer Tender documents.
4 documents required · 4 mandatory
₹11,800
SR AO (EA AND CASH) RVPN
₹11.1 L
JAIPUR
1 Jan 2025
28 Aug 2024
13 Nov 2024
28 Aug 2024
13 Nov 2024
18 Sept 2024
6 Sept 2024
Main Material/Items
Tubular Monopoles
220kV D/C transmission Poles(AP1/AP2 Type) (bottom cross arm 32M)
Overhead Line Material
Tower & Stub
High Tensile Steel
Mild Steel
Assorted Size G. I. Bolts and Nuts (ISI Marked), STEP BOLT and SPRING WASHER (ELECTRO-GALVANISED)
Conductor
ACSR Zebra Conductor (54/3.18 MM AL+7/3.18MM STEEL)
Conductor Hardware for Zebra
P.A. Rod for ACSR Zebra
V/D for ACSR Zebra
M.S. comp. Joint
Repaire sleeve
Earth Wire
Hardware for 7/3.15mmE/W
Susp Ass. for 7/3.15 mm E/W
Strian Ass. for 7/3.15 mm E/W with EB
V/D for 7/3.15 mm E/W
M.S. comp. Joint
Repaire sleeve
Earthing
Pipe type Earthing Set
Counter poise Earthing
Insulators
120 KN Long rod (220kV)
70 KN Long rod (220kV)
Danger Plate , Number Plate , & Phase Plate
Phase Plate
Danger Plate
Number Plate
Description of Work / Item(s)
DETAIL SURVEY AS PER TENTATIVE ROUTE INCLUDES THE FOLLOWING MAJOR ACTIVITIES:
Pegging of line route , providing of survey pillar at an interval of 3-4 Km line route with required jungle clearance for survey, profile preparation of approved route on graph sheet and marking of offset on either side of line , marking of side clearance for hills, sand dunes etc., as per specification and tower scheduling.
CHECK SURVEY AS PER APPROVED ROUTE OF LINE WHICH INCLUDES:
Rechecking of the line route as per approved profile, tower centre marking, pit marking, bisection of angle tower as per required at site.
EXCAVATION:
Excavation, excluding back filling, including shoring, shutering, dewatering etc. upto the required depth as per foundation speciafication / drawings.
(i) Any soil,soft rock other than hard rock
SETTING OF TEMPLATE & STUB / ANCHOR BOLT:-
Setting of template & stub/ anchor bolt & removal after concreting, excluding cost of excavation and concreting but including back filling with excavated/ borrowed earth (with lead & lift) in layers with ramming andwatering as per specification.
(i) Towers including extension upto 9 Meters
CONCRETING:
Providing and laying cement concrete for all types of foundation as per latest ISS:456 including cement, sand, stone aggregate 20mm nominal size, water etc., preparing surfaces, shuttering, mixing, placing, ramming, curing, finishing as per specification and drawings.
(iii) 1:3:6 Mix
Steel Reinforcement:
Cutting ,Bending , Welding of joint if required , fixing and placing of steel reinforcement as per specification and drawing s including material.
EARTHING:
(A) Earthing of towers with pipe type earthing excluding the supply of pipes, wires, flats & connectors, but including coke / charcoal, etc., excavation, augering and backfilling in all types of soil.
Erection of Towers:-
Erection of super structures including D-shakles, ACD, Hangers, U Bolts, Step bolts, danger plates, phase plate, number plate etc. Also including tack welding of bolts & nuts upto bottom cross arm/beam level including application of Zinc Rinch Paint.
i) Erection of towers(with extensions up to 9 Meters)
CONDUCTOR STRINGING:
(a) Stringing of ACSR Zebra including hoisting of insulator string, laying, jointing & tensioning of conductor, clamping with Armour rods and fixing of vibration damper per route KM of the line.
(i) Single conductor
EARTH WIRE STRINGING
(A) Stringing of galvanised steel stranded wire including laying,jointing & tensioning, clamping,clipping and fixing vibration damper and earth bond etc.
(I) One No. 7/3.15mm galvanised wire
DISMANTLING OF TOWER
Dismantling of super structures alongwith extenssion , having tack welded Bolts& Nuts , including removing of D shackles, hangers, U-Bolts, Step bolts, ACD, Danger Plate , Number plate, Phase plate of tower including transportation from site to our store and stacking of all material
(A) 132 KV and 220 KV S/C & D/C Tower (all Type)
DESTRINGING OF CONDUCTOR / EARTH WIRE
(A) Destringing upto ACSR Zebra conductor : Dismantelling of vibration dampers and armour rods, removal of conductor from clamps and fitting in rollers, detensioning, dehoisting of insulator string as required and collecting the material & depositing the same in our store and stacking
(i) Single conductor
(C) Destringing of Earth wire : Dismantelling of Earth bond, vibration dampers, declipping and fitting in rollerss , detensioning and collecting the material & depositing the same in our store and stacking.
(I) One No. 7/4mm galvanised wire
RESTRINGING OF CONDUCTOR / EARTH WIRE
(A) Restringing of ACSR Zebra conductor : Dismantelling of vibration dampers and armour rods, fitting in rollers, detensioning, holding & lowering of conductor , de-hoisting of insulator string as required , adding / removing and jointing of conductor, hoisting of insulator string, lifting of conductinto rollers and re-tensioning , jointing , fitting of armour rods and vibration dampers and clamping per route KM of the line section to be restrung dismantled material not re-used to be deposited in our store & stacked
(i) Single conductor
(C) Restringing of earth wire : Dismantelling of earth bond, vibration dampers ,declipping and fitting in rollers, detensioning, holding & lowering of earth wire , adding / removing and jointing of earth wire, lifting into rollers and re-tensioning , jointing, clipping and fitting of vibration dampers and earth bond per route KM of the line section to be restrung dismantled material not re-used to be deposited in our store & stacked
(I) One No. 7/4 mm galvanised wire
Removal of Stub of Dismantelled tower
Removal of stub of Dismantelled towers including digging of around the stub to a depth of 300MM below ground level , breaking the concrete of the chimney , cutting the stubs at a depth of 300MM below ground level , refilling the excavated earth and compacting the same for 1 set of 4 Nos. of stubs
Erection of 220kV Tubular Monopoles
(i)220KV D/C Transmission Poles(AP1/AP2 Types)
(ii)Earthing of Transmission Tubular Monopoles along with all required material as per the requirement of specification.
TUBULAR MONOPOLE
Civil work
(i)Soil Investigation Transmission Tubular Monopole
Foundation of 220kV Tubular Monopoles as per approved drawing /Design and specification
(i)220KV D/C Transmission Poles(AP1/AP2 Types)
(ii)Transmission Tubular Monopoles footing protection work including of required items as per the specification requirements.
SJV Infra Projects Private Limited (BID ID -2933330)
KAY CEE ENERGY & INFRA LIMITED (BID ID -2971321)
SALASAR TECHNO ENGINEERING LIMITED (BID ID -2985884)
KAY CEE ENERGY & INFRA LIMITED (BID ID -2971321)
SALASAR TECHNO ENGINEERING LIMITED (BID ID -2985884)
SJV Infra Projects Private Limited (BID ID -2933330)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
BOQ_747178.xls
BOQ • 0.37 MB
FinalBidTN_122.pdf
Tender Documents • 7.53 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .