| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC 1 A BASEMENT 30 31 RAJA HOUSE NEHRU PALACE NEW DELHI 110 019 | SOUTH EAST | DELHI | 110019 | ₹1.2 Cr | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹1.2 Cr+₹6.0 L (5.05%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD PIN 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | ₹1.2 Cr+₹6.0 L (5.05%) | L2 | Rejected-Finance Not the lowest bidder |
| 3 | L3₹1.3 Cr+₹10.3 L (8.69%)Rejected-Finance 59 49 A BIRHANA ROAD KANPUR KANPUR NAGAR UTTAR PRADESH 208001 | KANPUR NAGAR | UTTAR PRADESH | 208001 | ₹1.3 Cr+₹10.3 L (8.69%) | L3 | Rejected-Finance Not the lowest bidder |
| 4 | L4₹1.3 Cr+₹10.7 L (8.97%)Rejected-Finance 12 BHARTI AARTIST COLONY VIKAS MARG NEW DELHI 110092 | EAST | DELHI | 110092 | ₹1.3 Cr+₹10.7 L (8.97%) | L4 | Rejected-Finance Not the lowest bidder |
| 5 | L5₹1.3 Cr+₹14.6 L (12.3%)Rejected-Finance 53 VAISHAILI ENCLAVE SECTOR 9 INDIRA NAGAR LUCKNOW | LUCKNOW | ₹1.3 Cr+₹14.6 L (12.3%) | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
₹1.5 Cr
EMD Value
₹3.1 L
Closing Date
23 Jan 2020, 6:00 pmClosed
Senior Manager Engg-Elect
Senior Manager Engg-Elect AAI CATC Bamrauli Prayagraj
Providing higher capacity DG Set for Operational requirement at CATC, Allahabad
2020_AAI_39593_1
AAI/CATC/SM(E-E)/NIT-07/19-20
Open Tender
Electrical Works
Item Rate
240 days
AAI CATC Bamrauli Prayagraj
Please refer Tender documents.
13 documents required · 13 mandatory
₹1,120
Airports Authority of India
₹3.1 L
12 Nov 2020
6 Jan 2020
28 Jan 2020
7 Jan 2020
23 Jan 2020
7 Jan 2020
7 Jan 2020 - 17 Jan 2020
Amount
S.I.T.C. of 1 No. minimum 600 kVA , 415V, 3 phase,1500 R.P.M, 0.8 PF water/ coolant cooled, floor mounted Diesel Generator set with electronic governor and brush less alternator self excited and self regulated and acoustic enclosure & all accessories including supply & installation of Engine control panel with meters , CTs & transducers for all metering and protection, Antivibration mountings, residential type silencer, turbo charged after cooled, electric starter, batteries & battery charger, radiator, control wiring, first fill of lubricating oil, & Diesel for testing & commissioning at site & all spares & accessories, including sufficiently rated cooling system so as to obtain the full capacity of genarator as required complete with necessary civil work such as grouting, chipping, finishing etc.as required complete but without foundation. The work should be as per Central Electrical Inspectorate/ Pollution control boards standards.
Supply and Installation of M.S. ERW "C" Class 25 mm dia pipe with 25 mm dia ball valve including painting of pipe with desired shade of synthetic enamel paint
Supply and installation of 990 Ltr day service Fuel Tank capacity with level indicator, level switches,
Design, supply, erection, testing and commissioning of exhaust piping of 250mm dia size MS B Class exhaust pipes, SS belwo, bends, silencer insulation with welding joint including bends, clamps, dash fastener, flanges, nuts, bolts, insulation of exhaust pipe using 50 mm thick loosely bound resin mattress/mineral wool/rock wool density not less than 120 kg/mtr cube, wire chicken mesh over insulation and cladding aluminium sheet of 0.6 mm thick etc. complete as required and as per specifications.
Design, supply & fixing of self supporting MS structure suitable for pipes for exhaust of DG sets complete etc as required
Dismantling of existing 380 KVA diesel generator and accessories by disconnecting electrical, controls , fuel connections, exhaust system and earthing connections of DG set and transporting the upto AAI store (not more than 50 mtrs) by engaging skilled and un skilled manpower with required T & P and machinery (hydra, jcb) etc complete as required.
Supply of following sizes of XLPE insulated PVC sheathed, armoured power cable of 1.1 KV grade conforming to IS-7098, amended upto date.
3.5Cx 300 Sq. mm Aluminium conductor
8 core 1.5 sqmm Copper control cable
Supplying and making end termination with brass compression gland and aluminium lugs for following size of XLPE insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 kV grade as required.
3.5Cx 300 Sq. mm
8 core 1.5 sqmm Copper control cable
Laying of one number PVC insulated PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
upto 35 Sq. mm
Above 185 Sq. mm upto 400 Sq. mm
Laying of one number additional PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size exceeding 120 Sq. mm, but not exceeding 400 Sq. mm direct in ground in the same trench in one tier horizontal formation including excavation, sand, cushioning, protective covering and refilling the trench etc. as required.
Above 185 Sq. mm upto 400 Sq. mm
Laying of one number PVC insulated PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ STONEWARE/ METAL PIPE as required.
upto 35 Sq. mm
Above 185 Sq. mm upto 400 Sq. mm
Laying of one number PVC insulated PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.
upto 35 Sq. mm
Above 185 Sq. mm upto 400 Sq. mm
Providing and fixing following sizes of class `B' GI pipe with ISI mark in surface/ wall etc. as required.
100 mm (internal dia.)
Earthing with Copper earth plate 600mm X 600mm X 3 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr long etc with charcoal or coke and salt complete as required
Providing and fixing 50 mm X 5 mm Copper strip on surface or in recess for connections etc. as required
Providing and fixing 50mm x 5mm copper strip at 0.50 m. below ground level for connections ,termination with nut bolt etc as required
Providing and fixing 50 mm X 5 mm copper. strip in 65 mm dia G.I. pipe from earth electrode including connection with nut, bolt, spring, washer excavation and re-filling etc. as required.
Earthing with GI earth plate 600mm X 600mm X 6 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr long etc with charcoal or coke and salt complete as required
Supplying and laying 25 mm X 5 mm G.l strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
Providing and fixing 25 mm x 5 mm G. I. strip in 40 mm dia. G. I. pipe from earth electrode as required.
Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand :4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
450 mm width X 62.5 mm depth X 2.0 mm thickness
National Engineering
Choubay And Co.(Agencies) Pvt.Ltd.
VIJAYPOWER GENERATORS LIMITED
KRISHNA REFRIGERATION
PRAGYA ELECTRIC AND ELECTRONICS CORPORATION
S.M.Brothers
LUMOS INFRA PVT LTD
JAKSON AND COMPANY
Gainwell Commosales Private Limited
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .