Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.7 LAccepted-AOC | L1 | Accepted-AOC Bidder fulfills the requisite criteria and being lowest | |
| 2 | L2₹13.9 L+₹1.9 L (15.9%)Rejected-AOC | L2 | Rejected-AOC Bidder fulfills the requisite criteria but not being lowest | |
| 3 | L3₹15.1 L+₹3.2 L (26.3%)Rejected-AOC WARD NO 13 NEW SURATGARH | SURATGARH | L3 | Rejected-AOC Bidder fulfills the requisite criteria but not being lowest |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
12 Jan 2024, 6:00 pmClosed
CWE AF BIKANER
HQ CWE AF BIKANER
REPAIR/ MAINT OF SEWAGE TREATMENT PLANT, RO PLANT AND CERTAIN E/M WORKS AT AF STN SURATGARH
2023_MES_632882_1
81541/E8
Open Tender
Civil Works
Item Rate
334 days
GE AF SURATGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF SURATGARH
₹30,000
Yes
1 Mar 2024
15 Dec 2023
19 Jan 2024
15 Dec 2023
12 Jan 2024
29 Dec 2023
15 Dec 2023 - 22 Dec 2023
Amount
Dewatering the left over water from existing old sewage water storage tank of existing storage capacity , having round shape bottom plan size 5 meter and depth 12.5 meter, desalting, sludge, silt, all accumulated material with mud and sewage sludge from the bottom, sides, removing, cleaning, desalting, sludge, silt and all accumulated material with mud and sewage sludge from the bottom and sides from the outer perimeter of tank and depositing/spreading where directed, including preparation of surface by wire brushing and washing the surface with 2% potassium permanganate solution for disinfection and applying one coat of white wash including removal of roots and uprooting of grass etc. all around up to 3 meter from plinth of old sewage tank and removing mud and sludge out from area of sewage treatment plant complete all as specified and directed by Engr-in-charge.
Dewatering the left over water from existing still chamber and per screen chamber of existing storage capacity, having size 3x1.5 meter and depth 2 meter, desalting, sludge, silt, all accumulated material with mud and sewage sludge from the bottom, sides, removing, cleaning, desalting, sludge, silt, all accumulated material with mud and sewage sludge from the bottom and sides from the outer perimeter of tank and depositing/spreading where directed, including preparation of surface by wire brushing and washing the surface with 2% potassium permanganate solution for disinfection and applying one coat of white wash including removal of roots and uprooting of grass etc. all around up to 3 meter from plinth of still chamber, per screen chamber, removing mud and sludge out from area of sewage treatment plant, complete all as specified and as directed by Engr-in-charge.
Dewatering the left over water from existing sludge holding tank of existing storage capacity , having size 6x8 meter and depth 5 meter, desalting, sludge, silt, all accumulated material with mud and sewage sludge from the bottom, sides, removing, cleaning, desalting, sludge, silt, all accumulated material with mud and sewage sludge from the bottom and sides from the outer perimeter of tank and depositing/spreading where directed, including preparation of surface by wire brushing and washing the surface with 2% potassium permanganate solution for disinfection and applying one coat of white wash including removal of roots and uprooting of grass etc. all around up to 3 meter from plinth of sludge holding tank,and removing mud and sludge out from area of sewage treatment plant complete all as specified and directed by Engr-in-charge. Note :- existing sludge holding tank of existing storage capacity has cleaned two times in period paid by contractor .
Dewatering the left over water from existing chlorine contect tank of existing storage capacity, having size 6x8 meter and depth5 meter, desalting, sludge, silt, all accumulated material with mud and sewage sludge from the bottom, sides, removing, cleaning, desalting, sludge, silt, all accumulated material with mud and sewage sludge from the bottom and sides from the outer perimeter of tank and depositing/spreading where directed, including preparation of surface by wire brushing and washing the surface with 2% potassium permanganate solution for disinfection and applying one coat of white wash including removal of roots and uprooting of grass etc. all around up to 3 meter from plinth of chlorine contect tank , and removing mud and sludge out from area of sewage treatment plant complete all as specified and directed by Engr-in-charge. Note :- existing chlorine contect tank of existing storage capacity has cleaned two times in period paid by contractor .
Dewatering the left over water from existing equalize tank of existing storage capacity, having size 3x5 meter and depth 7 metre, desalting, sludge, silt, all accumulated material with mud and sewage sludge from the bottom, sides, removing, cleaning, desalting, sludge, silt, all accumulated material with mud and sewage sludge from the bottom and sides from the outer perimeter of tank and depositing/spreading where directed, including preparation of surface by wire brushing and washing the surface with 2% potassium permanganate solution for disinfection and applying one coat of white wash including removal of roots and uprooting of grass etc. all around upto 3 metre from plinth of equalize tank, and removing mud and sludge out from area of sewage treatment plant complete all as specified and directed by Engr-in-charge. Note :-existing equalize tank of existing storage capacity has cleaned two times in period paid by contractor.
Taking up or down steel tubing and connections of size 100 mm bore with connected valves, including internal cleaning of pipe, connected valves, removing from sludge, mud deposited inside the pipe, cleaning pipe internally with clean water pressure and refixing of pipes with suitable nuts and bolts as existing location complete all as specified and directed.
Taking up or down steel tubing and connections of size 150 mm bore with connected valves, including internal cleaning of pipe, connected valves, removing from sludge, mud deposited inside the pipe, cleaning pipe internally with clean water pressure and refixing of pipes with suitable nuts and bolts as existing location complete all as specified and directed.
Taking up or down steel tubing and connections of size 40/50/75 mm bore with connected valves, including internal cleaning of pipe, connected valves, removing from sludge, mud deposited inside the pipe, cleaning pipe internally with clean water pressure and refixing of pipes with suitable nuts and bolts as existing location complete all as specified and directed.
Painting of steel tubing and connections of size 40/50/75/100/150 mm bore with connected valves including outer cleaning of pipe and connected valves with suitable existing blue/black /yellow colour with arrow mark with approved paint and refixing of pipes with suitable nuts and bolts as existing location complete all as specified and directed.
Painting of motor pump sets including outer cleaning of motor pump sets and connected pipes with suitable existing blue /red colour with suitable marking with approved paint and refixing of motor pump sets with suitable nuts and bolts as existing location complete all as specified and directed.
Supply Dewatering Polyelectrolyte (DWPE ) powder, dewatering of organic sludge from sewage complete all as specified and directed by Engr-in-charge
Supply and fixing Ductile Iron Pipes of 100 mm dia, 'Heavy class', Flanged ends, class-K-7, suitable for and including flanged ends and suitable size of rubber washers etc. complete all as specified and directed. Note :-Earth work and excavation required shall be measured and paid under repctive items
Material and labour for DI specials such as tees, bends of any size and radius, tapers, collers, tail pieces, caps and plugs etc. complete all as specified and directed .
Supply and fixing only indicator lamp assembly LED type with red/green/blue for phases R,Y,B suitable for LT panels complete all as specified and directed.
Supply and fixing only Digital voltmeter 0-500 volt of size 96 Sqmm suitable for LT panels complete all as specified and directed. Make:- AE/MECO/SECURE/SCHNEIDER.
Supply and fixing only Digital ampere metre 0-300 Amps of size 96 Sqmm suitable for LT panels complete all as specified and directed. Make:- AE/MECO/SECURE/SCHNEIDER.
Disconnecting Electric connections from LT Control panel and starter, dismantling the defective Non clogging submersible Sewage pump set 415 Volts of fan motors 50 HZ of any RPM for following capacity and removing pipe line connections from discharge side and taking out submersible pump set along with column pipe from sewage sump of depth 12.5 mtrs with the help of chain pully block re-winding with super enamelled copper wire of best quality of existing size/gauge and weight inciuding raplacement of insulation material, varnish bearing connection plate and all other petty items required to make the motor functional and reassembling the motor including installation commissioning and testing on full load, complete all as specified & directed by Engineer-in-Charge. (Note :Cost of Transportation to workshop and back for repair and lowering of same pump in sewage sump after repair incl replacement of rusted nuts bolts , rubber gasket shall deemed to be included in quoted rate)
Repair /maint of centrifuge machine Make :Haller including removing & fixing of spare parts cleaning and greasing of all spare parts with suitable chemical and tight with bolts, nuts, washer etc. all as specified and directed by Engineer-in-charge. Note :- Spare parts suitable for existing centrifuge machine required to be replaced shall be separately under respective items.
Disconnecting, dismantling the defective three phase induction motor 415 Volts of fan motors 50 HZ of any RPM for following capacities and re-winding with super enamelled copper wire of best quality of existing size/gauge and weight inciuding raplacement of insulation material, varnish bearing connection plate and all other petty items required to make the motor functional and reassembling the motor including installation commissioning and testing on full load, complete all as specified & directed by Engineer-in-Charge
Disconnecting dismantling of cetrifugal monoblock pump set of following capacities of pumps any RPM and dismantiling defective parts such as impeller nut, gland, impeller key, gland packing water deflector bush bearings sleeve, gaskets, volute stud and nuts suction and delivery flange and stud and nuts and all other petty items required to make the pump set functional and reassembling the pump set including installation commissioning and testing, complete all as specified and directed by Engineer-in-Charge.
Supply and pouring Compressor Oil in air blower at STPs complete all as specified and as directed.
Labour for dismantling, disconnecting the Air Blower twin lobe positive displacement type of pressure upto 0.8Kg/cm2 and capacity upto 667 Cum/hr including disconnecting from channel frame and electrical panel for repair of Gear Box, refitting of gear box after oiling, greasing, alingment of pump set including transportation to workshop & back for repair and re-fixing/ assembling testing to make it functional complete inciuding cleaning of all dirt, dust etc. all as specified and directed by Engr-in-charge. NOTE : Spare parts required for repairing will be measured and paid under relevant item as supply only.
Supply only following spare parts in the twin lobe positive displacement type and pressure rating upto 0.8Kg/cm2 of Make-Usha
Replacement of Pully V Belt SPB-1800
Ball Bearing 6213 Make-SKF/ZKL
Ball Bearing 22213 Make-SKF/ZKL
Roller bearing 3213A Make-SKF/ZKL
Piston ring
Set of Gasket
Gear set complete
Oil seal
Oil level glass
Suction air filter
Air compressor shaft welding, turning, grinding
Bearing tapper bush for roller bearing 22213 EK/C3
Outer distance bush
Pressure ring
Asbestos graphite packing (casing cover)
Asbestos graphite packing (stuffing box)
Bearing Set
Pressing Bush
Distance ring
O-Ring
Gear wheel Pair
Air breather
Grob type suction filter
Withdrawl sleeve
Injection ring
Tensioning element
Pressing ring
Intermediate ring 'B'
Dowel pins
Lock nut
Lock washer
Packing casing/main cover
Packing main cover/outer
Supply and fixing in replacement 3 pole power contactor ML-2, 32 Amps, 415 Volts, 50 HZ suitable for fixing in existing panel complete all as specified and as directed. Make :- L&T /Siemens/ ABB/ HAVELL'S.
Supply and fixing in replacement 3 pole power contactor ML-3, 40 Amps, 415 Volts, 50 HZ suitable for fixing in existing panel complete all as specified and as directed. Make :- L&T / Siemens/ ABB/ HAVELL'S .
Supply and fixing in replacement 3 pole power contactor MNX-25, 45 Amps, 415 Volts, 50 HZ suitable for fixing in existing panel complete all as specified and as directed. Make :- L&T/ Siemens/ ABB/ HAVELL'S .
Supply and fixing in replacement 3 pole power contactor MNX-32, 55 Amps, 415 Volts, 50 HZ suitable for fixing in existing panel complete all as specified and as directed. Make :- L&T/ Siemens/ ABB/ HAVELL'S .
Supply and fixing in replacement 3 pole power contactor MNX-40, 55 Amps, 415 Volts, 50 HZ suitable for fixing in existing panel complete all as specified and as directed. Make :- L&T/ Siemens/ ABB/ HAVELL'S.
Supply and fixing in replacement 3 pole power contactor MNX-50, 85 Amps, 415 Volts, 50 HZ suitable for fixing in existing panel complete all as specified and as directed. Make :- L&T / Siemens/ ABB/ HAVELL'S .
Supply and fixing in replacement thermal over load relay type MN2, relay range 6-10 Amp, complete all as specified and as directed. Make L&T/ Havells/ABB/Siemens.
Supply and fixing in replacement thermal over load relay type MN2, relay range 9-15 Amp, complete all as specified and as directed. Make L&T / Havells/ABB/Siemens.
Supply and fixing in replacement thermal over load relay type MN2, relay range 14-23 Amp, complete all as specified and as directed. Make L&T/ Havells/ABB/Siemens.
Supply and filling Bio pac MBBR media cylindrical shape with external fins with 15 mm height and 22 mm diameter, black colour and effective surface area of media 400 m2/m3 complete all as specified and directed by Engineer-in-charge.
Testing and checking to maintain clear treated water from sewage treatment plant with the effluent quality as below :- (a) BOD < 10 mg/ ltr (b) COD <150 mg/ ltr (c) DO - 20 mg/ ltr or more (d) TSS < 10 mg/ ltr (e) PH - 6.5-8.5 (f) Oil and Grease < 10 mg/ ltr (g) Coliform < 100 MPN/ 100 ml (h) Res Chlorine < 1 mg/ ltr (i) Testing from NABL certified laboratories fortnightly to be carried out for item (a) to (g) above and proper record to be maintined. (ii) Residual Chlorine test to be carried out daily as per item No (h) above and proper record will be maintained. The testing record to be shown to JE concerned daily and weekly to Engr-in-Charge. Note : Rate quoted by the tenderer also includes the following (a) Cost of testing and maintaining record. (b) Cost of chlorination to achieve specified residual chlorine contents. (c) Cost of chemical required to obtained effluent quality as above (a) to (g).
Cutting and uprooting grass, vegetation shrubs, bushwood undergrowth, roots and trees not exceeding 30 cm girth (measure one metre above ground level) and removing rubbish to a distance upto 50 metres outside the periphery of the area, and out from area of sewage treatment plant complete all as specified and as directed by Engr-in-Charge.
Supply and fixing of gland packing dori with 10 mm in suitable size motor pump sets complete all as specified and directed by Engineer-in-charge.
Altoch-GP (Calcium based granular disinfectant more stable than chlorine gas & stronger than bleaching powder and sodium hypochlorite) for treatment of drinking water. Packing in 45 Kg plactic drums. Make : Declibac, Brand name : "ALTOCH-GP" or equivalent.
Material and labour for cleaning and scraching the surface of filter bed, walls, floor truffs, drains etc. by wire brushes or other wise to remove the deposited mud scms etc. and washing the filter bed with clean water complete all as directed by Engineer - in charge
Taking out existing exhausted filter media from filter bed of any size /depth including removing material to distance exceeding 50 meter but not exceeding 100 meter complete all as specified and as directed by Engineer - in -charge.
Supply and laying the natural gravel pebbles of size 10 mm to 20 mm grades complete all as specified and as directed by engineer in charge.
Supply and laying the natural gravel pebbles of size 6 mm to 10 mm grades complete all as specified and as directed by engineer in charge.
Supply and laying the natural gravel pebbles of size 2 mm to 6 mm grades complete all as specified and as directed by engineer in charge.
Supply and laying white silica sand filter media of effective size 0.5 mm to 2mm as per sample kept in GE office complete all as specified and directed. Note: Gravel for filter bed shall be obtained from approved source and filter sand shall be as per sample Kept in GE office.
Material and labour for cleaning RO water storage tank of storage capacity 10000Ltrs, material from the bottom, sides and removing to a distance not exceeding 50 metre from the outer perimetre of tank and depositing/spreading where directed. including preparation of surface by wire brushing and washing the surface by clear water including removal of roots and uprooting of grass etc. all around upto 2 metre from plinth of tank, complete all as specified and directed by Engineer-in-Charge.
Material and labour for servicing and repair /maint of RO Plant of capacity 11000 Ltrs/hrs including replacement of all bag filters cartridge filter,backwash of membrane (including chemical ), tightening of all bends and coupling of PVC Pipe, checking of electrical and control wiring etc. including testing of water from authorised lab after every service to check the desired value of drinking water complete all as specified and directed by Engineer-in-charge . Note :- Spare parts suitable for existing plant required to be replaced shall be paid separately under respective items .
Supply only Bag filter of size 7"X32"
Supply only cartridge filter of size 40"X2.5"
Supply, fixing, testing and commissioning of CPVC pipes of size 65 mm including using elbow,union,tee,etc as per site requirement including removing old unserviceable pipes complete all as specified and as directed.
supply, fixing, testing and commissioning of CPVC pipes of size 50 mm including using elbow, union, tee, etc as per site requirement including removing old unserviceable pipes complete all as specified and as directed.
Supply, fixing, testing and commissioning of CPVC pipes of size 20 mm including using elbow, union, tee, etc as per site requirement including removing old unserviceable pipes complete all as specified and as directed.
Supply only RO antiscalant for using Reverse Osmosis membrane effective in controlling deposition of inorganic scales effective in presence of chlorine and hardness up to 1000ppm, Effective calcium carbonate dispersion of high PH(up to 10) and alkalinity (upto 750), Excellent scale controle for high silica waters upto 150 ppm complete all as specified and as directed.
Supply, fixing, testing and commissioning of CPVC Ball valve union type of size 20 mm including using elbow, union, tee, etc. as per site requirement including removing old unserviceable valves complete all as specified and as directed.
Supply, fixing, testing and commissioning of CPVC Ball valve union type of size 50 mm including using elbow, union, tee, etc. as per site requirement including removing old unserviceable valves complete all as specified and as directed.
Supply, fixing, testing and commissioning of flow meter of range 1600-16000 (panel mount) including suitable size of washers etc. and any small item is required for fixing in panel is included in this rate complete all as specified and as directed.
Supply, fixing, testing and commissioning of flow meter of range 250-2500 (panel mount) including suitable size of washers etc. and any small item is required for fixing in panel is included in this rate in panel complete all as specified and as directed.
Supply, fixing, testing and commissioning of TDS meter model no CI -550 (panel mount) complete all as specified and as directed.
Supply, fixing, testing and commissioning including taking out old unserviceable Multiport/ Multifunctional valve of existing size fitted in 50mm dia CPVC/UPVC pipe for RO plant.
Material and labour for removing unserviceable membrane from RO plant of capacity 11000 Lt/Hr and supply and fixing new Membrane of diameter 200mm( model number 8040) having Max feed flow rate of 16 gpm,onsist of Polyamide Thin film composite and offering hard shell exterior for extra strength and testing for smooth functioning of RO plant all as specified and as directed.
Taking out old unserviceable dozing pump and Supply & Fixing Heavy duty Chemical Dosing system plunger type suitable to inject solution upto 25 LPH working pressure 10 kg /cm2 comprising dosing pump coupled with three phase electric motor of capacity 0.5 HP,1440 RPM assembly with agitator in one motor, agitator with SS sweep blade duly FRP coated, FRP tank 150 ltrs capacity, complete unit mounted on heavy duty MS fabricated frame duly anticorrosive paint complete with Chemical grade PVC NRV. along with Control panel for Dosing Pump suitable for Model SSAPS/CDSPT/25 made of powder coated MS fabricated box consisting of LED indicator, digital Volt meter, Amp meter, single phase preventor, High voltage low voltage protection complete all as specified and as directed. Make:- Sathya Sai / Sathya Sai Aqua Pura Services. Model No:- SSAPS/CDSPT/25/ST or equivalent.
Taking down old unserviceable LCM electric dosing pump, material and labour for LCM electric dosing pump, automatic type as installed at station RO plant complete all as specified and directed.
Supply, fixing, testing and commissioning of UPVC pipes of size 90mm outer dia including using elbow, union, tee, etc as per site requirement including removing old unserviceable pipes complete all as specified and as directed.
Supply, fixing, testing and commissioning of UPVC pipes of size 150mm outer dia including using elbow, union, tee, etc as per site requirement including removing old unserviceable pipes complete all as specified and as directed.
Supply, fixing, testing and commissioning of UPVC pipes of size 200mm outer dia including using elbow, union, tee, etc as per site requirement including removing old unserviceable pipes complete all as specified and as directed.
Supply and fixing of CPVC/ UPVC fittings like elbow, union, Tee, Reducer etc of size 200mm/ 150mm/ 100mm etc as per site requirement including removing old unserviceable fitting complete all as specified and directed by Eng in charge. Make : Prince/ Supreme/ Astral/ Kisan.
Supply and fixing of CPVC/ UPVC fittings like elbow, union, Tee, Reducer etc of size less than 100mm etc as per site requirement including removing old unserviceable fitting complete all as specified and directed by Eng in charge. Make : Prince/ Supreme/ Astral/ Kisan.
Taking down old unserviceable butter fly valve and material and labour for butter fly valve with rubber packing of size 200 mm complete all as specified and directed.
Taking down old unserviceable butter fly valve and material and labour for butter fly valve with rubber packing of size 150 mm complete all as specified and directed.
Taking down old unserviceable butter fly valve and material and labour for butter fly valve with rubber packing of size 100 mm complete all as specified and directed.
Taking down old unserviceable butter fly valve and material and labour for butter fly valve of size 80 mm complete all as specified and directed.
Supply and fixing of special type valves similar to sluice valves screwed down high pressure, heavy duty, with iron wheel head or lever type operation, flanged both ends for iron pipe or for unions suitable for 25 mm bore pipe as fixed at site, including taking down old unserviceable complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of special type valves similar to sluice valves screwed down high pressure, heavy duty, with iron wheel head or lever type operation, flanged both ends for iron pipe or for unions suitable for 40 mm bore pipe as fixed at site, including taking down old unserviceable complete all as specified and directed by Engineer-in-Charge.
Galvanised iron Tube 80 mm bore, 'Medium grade', ISI marked as per IS 1239 part-I with all fittings ISI marked including cutting, threading etc as per site requirement and drilling holes/fixing clamp set for taking branch connection from main pipe line in trenches/road/ nallah & fixed along walls/polls including mild steel clamps, screws etc, including taking down of old rusted iron tube, complete all as specified and directed by Engineer-in-Charge. Make: TATA/JINDAL/BST Note: Earthwork shall be measured and paid seperately
Material and labour for activated carbon filter media of same size and quality as per the existing media as approved and directed by Eng in charge.
Material and labour for water softening resin media of same size and quality as per the existing resin as approved and directed by Eng in charge.
Taking down old unserviceable mono block pump set of any size/capacity and supply & fixing commissioning and testing of monoblock pump set of capacity 3HP (65mmx50mm) or equivalent as per site requirement complete all as specified and all as directed. Make Kirloskar model No.KDS 325++ or Crompton
Suppy and fixing in replacement of 200 mm dia housing end cap port for 8040 membrane having material FRP all as specified and as directed.
Material and labour for replacement of panel door/ canopy made of CRCA MS sheet of thickness 3.15 mm and applying one coat of red oxide on out side surface and in side including all fixing accessories i.e. hinge, nuts, bolts, washers, cutting fabrication and welding works etc including taking out the old unserviceable door complete all as specified and as directed. Note : All existing items like Ammeter/ Voltmeter/ Push Buttons/ LED indicators/ Water Flow Meter/ TDS Meter etc shall be fabricated to new panel door or sheet as per the complete satisfaction of Engineer-in-charge.
Supply and fixing in replacement of unserviceable 3 pole power contactor LC1D18 Schneider make with Aux Contact/ Relay with inbuilt reset/ stop option or equivalent as per site requirement.
Supply and fixing in replacement of unserviceable 3 pole power contactor LC1D09 Schneider make with Aux Contact/ Relay with inbuilt reset/ stop option or equivalent as per site requirement.
Supply and fixing in replacement of unserviceable 3 pole power contactor LC1D25 Schneider make with Aux Contact/ Relay with inbuilt reset/ stop option or equivalent as per site requirement.
Removing old unserviceable starter any type and supply and fixing testing and commissioning DOL starter, AC 3 phase, 415 Volt, 50 Hz with sheet metal enclosure with wide band coil heavy duty with single phase preventer suitable for 10 HP/12HP motor including making connection with suitable size of copper cable complete all as specified and as directed.
Removing old unserviceable MCCBS and supply and fixing MCCBs 100 Amp 16 KA 3/4 pole complete all as specified and as directed.
Supply, fixing, testing and commissioning including taking out old unserviceable Multiport/ Multifunctional valve of existing size fitted in 90mm dia CPVC/UPVC pipe for swimming pool.
Supply, fixing, testing and commissioning including taking out old unserviceable filtered water injector floor nozzle of existing size for station swimming pool complete all as specified and as directed.
Supply and fixing PVC insulated & PVC sheathed industrial cable for submersible pump motors, flat three core of nominal area of conductor 6 sqmm, 1100 volts, conforming to IS : 693, complete all as specified and as directed.
Supply and fixing PVC insulated & PVC sheathed industrial cable for submersible pump motors, flat three core of nominal area of conductor 10 sqmm, 1100 volts, conforming to IS : 693, complete all as specified and as directed.
Supply and fixing PVC insulated & PVC sheathed industrial cable for submersible pump motors, flat three core of nominal area of conductor 16 sqmm, 1100 volts, conforming to IS : 693, complete all as specified and as directed.
Material and labour for replacement of earthing complete with galvanized iron or steel plate electrode 600 mm x 600 mm x 6.00 mm thick buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 25 x 4 mm dia as earthing lead by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to machinery/equipment all as shown in electrical plate No. 3 of SSR-2010 Part I and including necessary excavation and earth work in any type of soil, 20mm bore light grade GI pipe for watering, funnel, wire mesh, PCC (1:3:6) type C-1 chamber, PCC (1:2:4) type B-1 reinforced with 6 mm dia MS round bars @ 15 cm c/c both ways for cover 50 mm thick and MS frame of suitable size made of angle iron 50 x 50 x 6 mm, complete all as specified. Note :- (i) The unit rate includes earth lead and protection pipe up to maximum 7.5 metre from earth plate to earth point/test point. (ii) Earth pit shall be constructed minimum 0.5 metre away from existing earth.
Supply and fixing in replacement of old unserviceable earth continuity conductor of size 32x6 mm galvanised iron strip along with all necessary jointing material complete all as directed by Engineer in charge.
Taking down old unserviceable swimming pool centrifugal pump set, supply, fixing, testing and commissioning of swimming pool centrifugal pump set, three phase of capacity 3HP including making connection with suitable size of copper cable complete all as specified and as directed.
M. S. CONTRACTOR
AGGARSAIN BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .