Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹10.3 LAccepted-AOC 656 VINOBA BASTI SRI GANGANAGAR 335001 RAJ | SRI GANGANAGAR | SRI GANGANAGAR | RAJASTHAN | 335001 | 1 | Accepted-AOC Lowest | |
| 2 | 2₹12.5 L+₹2.0 L (19.6%)Rejected-Finance | 2 | Rejected-Finance Not Lowest | |
| 3 | 3₹13.3 L+₹2.8 L (27.3%)Rejected-Finance | 3 | Rejected-Finance Not Lowest | |
| 4 | Rejected-Technical KOHLI NO 17509 GALI KHADDAR BHANDAR WALI BHI WALA ROAD BATHINDA PB 151001 | BATHINDA | BATHINDA | PUNJAB | 151001 | - | Rejected-Technical Not Eligibile as per NIT | |
| 5 | Rejected-Technical BLDG NO XI 74 NEAR VALLARAM KULLANGARA TEMPLE KUNHIMANGALAM KOVVAPPURAM PO KANNUR DIST KERALA 670309 | KANNUR | KERALA | 670309 | - | Rejected-Technical Not Eligibile as per NIT |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
30 Aug 2022, 6:00 pmClosed
CWE Bathinda
HQ CWE Bathinda, Bathinda Military Station
REPAIR, MAINT AND REPLACEMENT AND CLEANING OF MS PIPES GI DUCTS, AIR HANDLING UNITS AND VARIOUS FILTERS OF AC PLANTS AT VARIOUS LOCATIONS UNDER GE (U) BATHINDA AT BATHINDA MIL STN
2022_MES_541207_1
CWE BTD 8112/2022-23/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bathinda
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (U) Bathinda
₹30,000
Yes
30 Sept 2022
27 Jul 2022
1 Sept 2022
27 Jul 2022
30 Aug 2022
18 Aug 2022
27 Jul 2022 - 10 Aug 2022
Amount
M&L for dismantling of existing Air Handling Unit of any capacity , cleaning, servicing, overhauling to all component of AHU, with and including cleaning of heating & cooling coil with caustic soda solution, including welding / brazing wherever required to arrest leakages, cleaning of Pre-Micro Filters, replacing of vertical GI sheet supports, complete replacement of foam insulation of best quality using adhesive substance to avoid cold air leakages, fabrication of bottom GI tray of existing size with drain pane made out of 16 gauge thick GI Sheets duly painted with bituminous paint over interior surface of tray, re-assembling all the dismantled components to its original position using new nuts, bolts, washers and other packing materials etc, with and including testing, commissioning of Air handling Unit at optimum efficiency complete all as directed.
M&L for cleaning inside surface of Air supply return/exhaust ducts all grills, dampers & diffusers of HVAC system by using high power vacuum air compressor, robotic camera air hammer, special nozzle, air sweep with other required accessories complete all as directed by Engr-in-Charge. Note :- (a) For the purpose of payment duct surface area only will be measured. (b) The tenderer is responsible for any damage/breakage caused at the time of cleaning and the tenderer will repair/replace the same without any extra cost to the Govt.
Taking down old unserviceable air filter from AHU and S&F pre air filter of size 610 X 610 X 50mm HDPC of 5 micron complete all as specified and directed.
Taking down old unserviceable Pre air filter from AHU and S&F Hepa air filter of size 605 X 305 X 50mm HDPC of 5 micron 99.97% complete all as specified and directed.
Taking down old unserviceable Pre air filter from AHU and S&F Hepa air filter of size 305 X 305 X 50mm HDPC of 5 micron 99.97% complete all as specified and directed.
Taking down old unserviceable Pre air filter from AHU and S&F Hepa air filter of size 508 X 508 X 25mm HDPC of 5 micron 99.97% complete all as specified and directed.
Taking down old unserviceable Pre air filter from AHU and S&F Hepa air filter of size 610 X 508 X 25mm HDPC of 5 micron 99.97% complete all as specified and directed.
Taking down old unserviceable Pre air filter from AHU and S&F Hepa air filter of size 590 X 590 X 50mm HDPC of 5 micron 99.97% complete all as specified and directed.
Taking down old unserviceable Pre air filter from AHU and S&F Hepa air filter of size 590 X 368 X 50mm HDPC of 5 micron 99.97% complete all as specified and directed.
Taking down old unserviceable Pre air filter from AHU and S&F Hepa air filter of size 630 X 490 X 50mm HDPC of 5 micron 99.97% complete all as specified and directed.
Taking down old unserviceable Pre air filter from AHU and S&F Hepa air filter of size 465 X 400 X 12mm HDPC of 5 micron 99.97% complete all as specified and directed.
Taking down old unserviceable Bag air filter from AHU and S&F Hepa air filter of size 610 X 610 X 305mm HDPC of 5 micron 99.97% complete all as specified and directed.
Taking down old unserviceable Bag air filter from AHU and S&F Hepa air filter of size 610 X 305 X 305mm HDPC of 5 micron 99.97% complete all as specified and directed.
Taking down old unserviceable Bag air filter from AHU and S&F Hepa air filter of size 305 X 305 X 305mm HDPC of 5 micron 99.97% complete all as specified and directed.
Taking down old unserviceable Bag air filter from AHU and S&F Hepa air filter of size 610 X 610 X 300mm HDPC of 5 micron 99.97% complete all as specified and directed. Note for BOQ item Nos 3 to 15:- Make :- STAR PUROTECH or any other equivalent make approved by GE as per appx 'B' attached in tender document.
Disconnecting the water sensor from chiller unit and S&F water sensor as per sample for chiller unit.
Supply only, in replacement, of Single phase heating element capacity 03 KW, ISI marked of existing shape and size suitable for hot water generator and making electric connections and taking down old unserviceable heating elements, complete all as directed. Make : Daspass / Theata
All as per Ser item No. 17 here-in-before but of capacity 02 KW.
S&F in replacement Poly-F Plus PB classical Belts of size B-41. Make Fenner/Dunlop
All as per Ser item No. 19 here-in-before but of size B-42
All as per Ser item No. 19 here-in-before but of size B-56
All as per Ser item No. 19 here-in-before but of size B-62
All as per Ser item No. 19 here-in-before but of size B-66
All as per Ser item No. 19 here-in-before but of size B-69
All as per Ser item No. 19 here-in-before but of size B-70
All as per Ser item No. 19 here-in-before but of size B-77
All as per Ser item No. 19 here-in-before but of size B-83
All as per Ser item No. 19 here-in-before but of size B-102
All as per Ser item No. 19 here-in-before but of size B-107
All as per Ser item No. 19 here-in-before but of size B-117
All as per Ser item No. 19 here-in-before but of size A-26
All as per Ser item No. 19 here-in-before but of size A-28
All as per Ser item No. 19 here-in-before but of size A-31
All as per Ser item No. 19 here-in-before but of size A-38
All as per Ser item No. 19 here-in-before but of size A-51
All as per Ser item No. 19 here-in-before but of size A-53
M&L for dismantling of blower shaft of AHU of capacity up to 10000 CFM by removing the belt and pulley, blower drum, and re-mentling the shaft and filling of metal at decayed portions including all welding, turning, polishing and other machine works required to make the shaft of required shape and size, as original, balancing the shaft and refitting in AHU including re-assembling the blower, pulley etc with and including replacement of new bearing of existing size, testing the AHU for satisfactory operation, complete all as directed.
All as per item No. 37 here-in-before but for AHU of capacity exceeding 10000 CFM but upto and including 20000 CFM capacity.
M&L for applying one coat of synthetic enameled paint of desired colour over a coat of red oxide primer on steel/iron surfaces of pipes after preparing surfaces with help of emery paper etc removing rust, dust and old paints and making surfaces smooth for achieving better grip between surface and primer all as specified.
M&L for applying one coat of aluminium paint on steel/iron cable trays, Aquastic protection surfaces , aluminium pipe insulations etc after preparing surfaces with help of emery paper etc removing rust, dust and old paints and making surfaces smooth for achieving better grip between surface and primer all as specified.
S&F in replacement of temperature gauge bottom connected, direct mounted type, of temperature range of 0 - 100°C or 32 - 212°F, including necessary welding complete all as directed. Make : H Guru/Fiebig/Anergy/Emerald
S&F in replacement of Pressure gauge dial type range between 0 to 12 kg/cm2 with siphon assembly with on/off knob including necessary welding cutting all as per directed. Make : H Guru/Fiebig/Anergy/Emerald
S&F CI butterfly valve, ISI marked, PN - 1.6 pressure grade, having Nitrile/EPDM rubber lining, SS stem,CS/SS disc, lever operated type, of size 50 mm dia bore with hand wheel including all jointing material i.e, nuts, bolts, washers, packing materials etc, duly insulated and taking out of old unserviceable valve complete all as directed.
All as per item No.43 above but bore size of 80 mm.
All as per item No.43 above but bore size of 150 mm.
S&F 150 mm bore dia CI non return valve, ISI marked, PN- 1.6, conforming to IS 5312 Part -I, both ends flanged, heavy duty, including packing materials, nuts, bolts, washer etc and testing complete including taking out of old U/S non return valve all as directed. Body Cover CI IS : 210, Gr. FG260. Body Rings - Bronge : IS 318 Gr. LTB2. Hinge Pin-SS ASTM A276 Type 410. Flange Drilling - IS 1538, Table 4 & 6.
All as per item No.46 above but bore size of 200 mm.
S & F 50 mm bore gate valve cast copper alloy screwed down high pressure with crutch handle, screwed both ends, for Iron pipe including taking out of old unserviceable gate valve complete all as directed.
All as per item No 48 here-in-above but size 40 mm bore.
All as per item No 48 here-in-above but size 32 mm bore.
All as per item No 48 here-in-above but size 25 mm bore.
All as per item No 48 here-in-above but size 20 mm bore.
Dismantling of old compressor, flushing the system, Re-fixing the new compressor suitable for 12.5 TR model No. SZ 1854 RC, pressure testing, vacuum the system, gas charging & finally commission the system complete all as specified.
M&L in replacement, of PVC fins Box suitable for cooling tower from 05 to 40 TR capacity, FRP induced draft type (Model : CM-12), complete all as directed. Make : Mihir/Paharpur
Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender from total amount of Schedule 'A'/BOQ
M/s Kataria Construction Company
MODERN ENTERPRISES
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .