Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.0 LAccepted-AOC | ₹4.0 L | L1 | Accepted-AOC Lowest Tenderer |
| 2 | L2₹4.2 L+₹18,629 (4.63%)Rejected-Finance 0 MANPUR CHITBARAGAON CHITBARAGAON BALLIA UTTAR PRADESH 221713 | BALLIA | UTTAR PRADESH | 221713 | ₹4.2 L+₹18,629 (4.63%) | L2 | Rejected-Finance Other than Lowest Tenderer |
| Sl No | Description | Qty | Unit | M/s Chopra Constructions L1 | NATIONAL TRADING COMPANY L2 |
|---|---|---|---|---|---|
| 1.00 | Taking down carefully ceiling fans at any height of any sweep/ make /model after disconnecting electric connection and dismantling and opening the body of ceiling fan and examine for repairs including servicing,overhauling, greasing etc and cleaning the complete body both internal & external parts with cleaning agent and renewal of minor spare parts such as split pins,cater pins,coupling bolt, capacitor holder,terminal adoptor, screws, nuts, spring washers for blade/body etc and replacement of components/accessories such as ball bearings, gun metal bushes, capacitor, canopy top & bottom, shackle clip assembly and assembling of all parts, remetalling of worn out shaft of fan cutting brazing machining and polishing to make the shaft suitable for fixing of new ball bearing and fixing ball bearing in replacement of bushing system in ceiling fan and assembling the same and testing to the engineer in charge to ensure smooth and noise free operation(bearing shall be measured and paid seperately) including hanging and fixing back in existing location and connecting of electrical connections and testing for its satisfactory performance complete all as specified and directed. (Note:- (i) Spare parts will be measured and paid separately under relevant item of schedule as supply only (ii) Rewinding of fan motor,painting will be measured and paid separetly under relevant item of schedule (iii) Labour element for fixing of spare parts and removing old unserviceable items are deemed to be included in quoted rate. (iv) All repair works will be carried out at ON site/ workshop E/M yard as directed by EIC. (v)Repair works of fans should completed and refixed the same within 12 hours after receipt of complaint slip.If the complaint not attended /not completed on same day recovery will be done from RAR bill as follows: a) For first day Rs 200 b) For second day Rs 300 c) For next every day Rs 500 | 255 | Each job | 1 ₹255 Lowest | 100 ₹25,500 |
| 2.00 | All as per serial item No.01 here-in-before but for exhaust fan of size 300mm/450mm sweep | 95 | Each Job | 1 ₹95 Lowest | 100 ₹9,500 |
| 3.00 | Material and labour for taking out and removing burnt copper winding, cleaning the armature, rewinding the ceiling fan (1200/1400mm sweep) armature/motor with new super enamelled copper wire of existing gauge including supply and fixing necessary E class insulating materials etc and varnishing with approved grade of insulation varnish and heating up and testing all as specified and as directed. | 240 | Each job | 425 ₹1,02,000 | 100 ₹24,000 Lowest |
| 4.00 | M&L for rewinding of heavy duty exhaust fan motor of 300 mm sweep of any make/model/type with new supper enamelled copper winding wire of similar gauge and number of turns and assembling of fan motor and rotor and testing including removing burnt out copper winding wire from fan motor complete all as specified and directed. | 60 | Each job | 400 ₹24,000 | 160 ₹9,600 Lowest |
| 5.00 | All as per Item No.4 above but 450mm. | 10 | Each job | 400 ₹4,000 | 150 ₹1,500 Lowest |
| 6.00 | Supply only gun metal bush suitable for ceiling fan/Exhaust fan/Air circulator fan /wall mounted fan of any sweep/type of any size | 310 | Each | 5 ₹1,550 Lowest | 50 ₹15,500 |
| 7.00 | Supply only Ball bearing No.6201/6202/6203/6204 for ceiling fan | 240 | Each | 5 ₹1,200 Lowest | 30 ₹7,200 |
| 8.00 | Supply only fan condensor 2.5 mfd,230 volt,AC 50Hz confirming to IS 1709 for ceiling fan,exhaust fan,wall mounted fan and pedestal fan | 255 | Each | 20 ₹5,100 Lowest | 20 ₹5,100 Lowest |
| 9.00 | Supply only fan condensor 3.15 mfd | 95 | Each | 35 ₹3,325 | 20 ₹1,900 Lowest |
| 10.00 | Supply & fixing Electronic fan regulator stepped type with five step ,two module, 100Watt 240 volts complete all as directed. | 65 | Each | 100 ₹6,500 Lowest | 150 ₹9,750 |
Tender Value
₹4.4 L
EMD Value
₹8,840
Closing Date
12 Aug 2026, 6:00 pmClosed
AGE(I) CIF(R)
AGE(I) CIF(R) RAJOURI
REPAIR/MAINTENANCE OF SUMMER AND COOLING APPLIANCES WITH CONNECTED WORKS AT HQ 6 SECT RR AND HQ 13 SECT RR UNDER AGE (I) CIF (R) 2nd Call
2026_MES_765978_2
AGE(I)/R-13/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
AGE(I) CIF(R)
Class E and above and category b(i)
8 documents required · 8 mandatory
₹300
Yes
AGE(I) CIF(R)
₹8,840
Yes
17 Sept 2026
10 Jul 2026
19 Aug 2026
10 Jul 2026
12 Aug 2026
24 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down carefully ceiling fans at any height of any sweep/ make /model after disconnecting electric connection and dismantling and opening the body of ceiling fan and examine for repairs including servicing,overhauling, greasing etc and cleaning the complete body both internal & external parts with cleaning agent and renewal of minor spare parts such as split pins,cater pins,coupling bolt, capacitor holder,terminal adoptor, screws, nuts, spring washers for blade/body etc and replacement of components/accessories such as ball bearings, gun metal bushes, capacitor, canopy top & bottom, shackle clip assembly and assembling of all parts, remetalling of worn out shaft of fan cutting brazing machining and polishing to make the shaft suitable for fixing of new ball bearing and fixing ball bearing in replacement of bushing system in ceiling fan and assembling the same and testing to the engineer in charge to ensure smooth and noise free operation(bearing shall be measured and paid seperately) including hanging and fixing back in existing location and connecting of electrical connections and testing for its satisfactory performance complete all as specified and directed. (Note:- (i) Spare parts will be measured and paid separately under relevant item of schedule as supply only (ii) Rewinding of fan motor,painting will be measured and paid separetly under relevant item of schedule (iii) Labour element for fixing of spare parts and removing old unserviceable items are deemed to be included in quoted rate. (iv) All repair works will be carried out at ON site/ workshop E/M yard as directed by EIC. (v)Repair works of fans should completed and refixed the same within 12 hours after receipt of complaint slip.If the complaint not attended /not completed on same day recovery will be done from RAR bill as follows: a) For first day Rs 200 b) For second day Rs 300 c) For next every day Rs 500 | 255 | Each job | - | - |
| - | All as per serial item No.01 here-in-before but for exhaust fan of size 300mm/450mm sweep | 95 | Each Job | - | - |
| - | Material and labour for taking out and removing burnt copper winding, cleaning the armature, rewinding the ceiling fan (1200/1400mm sweep) armature/motor with new super enamelled copper wire of existing gauge including supply and fixing necessary E class insulating materials etc and varnishing with approved grade of insulation varnish and heating up and testing all as specified and as directed. | 240 | Each job | - | - |
| - | M&L for rewinding of heavy duty exhaust fan motor of 300 mm sweep of any make/model/type with new supper enamelled copper winding wire of similar gauge and number of turns and assembling of fan motor and rotor and testing including removing burnt out copper winding wire from fan motor complete all as specified and directed. | 60 | Each job | - | - |
| - | All as per Item No.4 above but 450mm. | 10 | Each job | - | - |
| - | Supply only gun metal bush suitable for ceiling fan/Exhaust fan/Air circulator fan /wall mounted fan of any sweep/type of any size | 310 | Each | - | - |
| - | Supply only Ball bearing No.6201/6202/6203/6204 for ceiling fan | 240 | Each | - | - |
| - | Supply only fan condensor 2.5 mfd,230 volt,AC 50Hz confirming to IS 1709 for ceiling fan,exhaust fan,wall mounted fan and pedestal fan | 255 | Each | - | - |
| - | Supply only fan condensor 3.15 mfd | 95 | Each | - | - |
| - | Supply & fixing Electronic fan regulator stepped type with five step ,two module, 100Watt 240 volts complete all as directed. | 65 | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.34 MB
BOQ_871097.xls
BOQ • 1.49 MB
TenderDocumentFinal.pdf
Tender Documents • 0.98 MB
13c.pdf
PDF • 0.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .